iFlow(彩色血流编码)操作应用
本文档介绍iFlow(彩色血流编码)操作应用。
SIEMENS Healthineers iFlow(彩色血流编码)操作应用 1.Iflow操作流程: 1)保证术前术后C臂参数,SID(源像距),注射方案一致; 2)C臂位置:一般选择正位和侧位; 3)SID:保证术前术后平板高度一致; 4)FOV: 术前术后视野缩放一致; 5)注射部位导管头位置一致、导管型号一致; 6)注射前导管内充满造影剂; 7)造影持续时间:静脉期显影; 8)造影剂设置:速率和总量根据病变位置和性质决定基本原则是选择能最佳显示病变的 DSA帧频;注射延迟:1s;造影剂浓度:100%; Fig1 Fig2 Job Aid | iFlow(彩色血流编码)操作应用 1 Unrestricted | Effective Date: 2020-11-16 | HOOD05162003139979 https://www.siemens.com/pepconnect SIEMENS Healthineers 2.操作界面介绍(Leo Angio选项卡): (彩色编码阈值时间) (测量区域工具) View Image DSA Adjus Calib. Tools Stalling [s] 0.27 R Duration [s] 11.6 Jopac 11.87[s] ......................... ......................................... O iFlow激活键 彩色编码显示血流总时间 血流达峰时间测量:从曝光后开始记时每个像素点造影剂最大充盈时间 DSA 7.5 f/s STOP .27 E View Image DSA 3.17 R R @ jopac 5.07 Adjust | Calib. Tools ₩.60€ Starting [s] 0.27 18.935/18,00€ 60s 7.60s Duration [s] 8.97 11.6 Time Vs Contrast Intensity Graph X contrast concentration 11.87[s] o. SM 时间密度曲线: 达峰曲线形态可以反映像素点的性质:动脉、静脉或实质 Job Aid | iFlow(彩色血流编码)操作应用 2 Unrestricted | Effective Date: 2020-11-16 | HOOD05162003139979 https://www.siemens.com/pepconnect SIEMENS Healthineers 3.iFlow临床意义及优势: 1)以彩色图像显示整个DSA序列,iFlow图像能更好的显现血管的形态; 2)显示肿瘤的早期血管化,清楚的显示手术后的效果; 3)iFlow结合2D-DSA较单独2D-DSA图像显示病变更加全面,且不增加患者的X线辐射剂量 及对比剂用量; 4)其中动脉瘤病变,iFlow除了能显示瘤体的形态还能反映瘤腔内紊乱的血流变化,动静 脉分流病变; 5)对于神经计入造影来说,务必需要采集至静脉期,在比较时可使用“远端时间-近端时 间”的差值标记; 6)iFlow可以在一幅彩色编码血流图上显示动脉期到静脉期的整个循环过程以及更加直观 的显示异常分流; 7)iFlow可以更好的评估狭窄程度、代偿情况以及术后的疗效; 8)iFlow除了提供更加直观易读的彩色编码血流图之外还是一种定量分析的工具。 1/1/1960 Vier2007 4.iFlow病例展示: Fig1 Fig2 1)下肢动脉PTA Fig1:下肢动脉闭塞; Fig2:球囊扩张后支架释放后评估; Tip: iFlow技术在下肢血管疾病的诊 疗过程中,可以一站式数据化评估靶 opac 130 opac 165 opac opac 89 血管术前和术后血液动力学变化,是 Flow HOW 2.2e-005 2.2e-005 flow 3.4e-005low 3.2e-005 辅助医生判断疗效及评价预后的有 opac 129 opac 112 效方法. flow 2.6e-005 flow 3.2e-005 IGLE PLANE SINGLE A NOT FOR DIAGNOSTIC USE Job Aid | iFlow(彩色血流编码)操作应用 3 Unrestricted | Effective Date: 2020-11-16 | HOOD05162003139979 https://www.siemens.com/pepconnect SIEMENS Healthineers 1000215380 AXIOM-Artis 1000215380 VC14J 131115 Fig1 Fig2 VC14J 131115 1/2/1964, M, 50Y HFS *1/2/1964, M, 50Y STUDY 2 STUDY 2 1/7/2014 1/7/2014 4:02:19 PM 3:16:00 PM 25 IMA 2/1 24 IMA 2/1 SING 25 SING 24 6.80 80 2.47 2.73 1.66 After-2 After-1 Pre-2 5.80 Pre-1 60 Ref-A 7.47 8.53 Ref-B Selected ROL Ret-A After-2 After-1 Selected ROI: Ret-B Pre-2 Pre-1 ROI Arca [mm"2); 13.90 13,90 ROI Arca (mm"2); 13.90 13.90 13.90 ROI Peak / Ref Peak: 1.00 0.53 0.59 DE'EL ROI Peak / Ref Peak! 1.00 0.26 0.21 ROI Peak Time (s): AG 25: / Het AUC: 2.67 3,20 3.20 ROI Peak Time [a]: 2.93 4.27 1024*1024 A6 24 / Ret AUC: 6.40 0.82 0.79 0.56 1024*1024 iFlow New Series Secondary Capture Image iFlow New Series Secondary Capture Image 2)颅内动脉狭窄:Fig1:大脑中动脉狭窄;Fig2:支架开通后Fig评估; Fig1 1.95946 Fig2 1.9 3.21959 3.2 4.47973 4.4 5.73986 5.7 7 7.0 3)动静脉畸形、动静脉漏:Fig1:栓塞前;Fig2:生物胶栓塞后; Fig1 10.115 Fig2 8.80 8.80 9.54 9.54 10.29 10.2 11.05 11.0 OPAC EE 7% OPAC E 7% 4)肝动脉栓塞术:Fig1:肝癌造影iFlow评估;Fig2:iFlow与透视叠加引导手术 栓塞;增加手术全提高栓塞精准度; Job Aid | iFlow(彩色血流编码)操作应用 4 Unrestricted | Effective Date: 2020-11-16 | HOOD05162003139979 https://www.siemens.com/pepconnect SIEMENS Healthineers Disclaimer 请注意,该资料仅供学习使用! 为了正确使用软件或硬件,请务必使用由西门子医疗发行的《操作手册》或《使用说明》(以下统称为《操作手 册》)。本材料仅学习参考使用,不能代替《操作手册》。本培训中使用的材料可能未及时更新,并不一定反映 软件和硬件最新版本。 操作手册应作为您的主要参考资料,特别是在涉及警告和注意事项之类的安全信息时。 注意:本资料中显示的某些功能为可选项,可能未包含在您的系统中。 某些产品,与产品相关的声明或者功能(以下统称为“功能”),可能尚未在您的国家/地区进行商业销售。 受 监管要求所限,我们并不能保证所述功能将来能够向特定国家/地区提供。请联系当地的西门子医疗销售代表获 取最新信息。 未经书面授权,不得复制、传播、分发该资料及其相关内容,违者将承担相关责任。 所有患者的姓名和数据、参数和配置相关的名称均为虚构,仅作示例使用。 所有权利,包括专利权或产品的注册、设计的权利,均予保留。 版权所有 © 西门子医疗系统有限公司 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers
- Artis
- 3D,4D任务卡