YSIO X.pree Image Impression Job Aid
This job aid provides you with an overview of the functionalities and optimization of image impression on YSIO X.pree.
Target group: Basic user, all users.
Recommended to be viewed on the following devices: All (incl. tablet, smartphone).
SIEMENS Healthineers YSIO X.pree Image Impression Job Aid Template Effective Date: 10 Aug 2021 | HILS 2223 Job Aid Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Image impression on YSIO X.pree SIEMENS Healthineers Table of contents Clinical Imaging Processing Task 3 Flavor 4 Sliders 6 How to select the right image impression 7 What data is required if you contact your local Siemens Healthineers organization 8 Export images for YSIO X.pree (syngo XR) 9 Enable the Backup mode on YSIO X.pree 10 Processed and Raw (Backup mode) 11 Export image from a Siemens Healthineers FLC-based system 12 2 Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Clinical Image Processing Task SIEMENS Healthineers The imaging pipeline of the YSIO X.pree requires different Clinical Image Processing Task parameters for every body part examined. For example, a Abdomen knee has a different appearance than a chest. C-Spine LAT EXI Test The Clinical Image Processing Task (CIPT) consists of a set Extremities of flavors that fit a certain clinical task (e.g. Foot Rheumatism) or body part (e.g. Femur). Femur Finger We recommend using a CIPT that fits the body part examined and the clinical task selected. Finger LAT Foot DP Foot LAT Foot Rheumatism 3 Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Flavor SIEMENS Healthineers A Flavor is a variation of parameters which create a specific image impression. Higher contrast Flavor 1.0 Increased edge Flavor 1.1 enhancement with Flavor 1.2 higher number Flavor 1.3 Moderate contrast Flavor 2.0 Increased edge Flavor 2.1 enhancement with Flavor 2.2 higher number Flavor 2.3 Focus on bone contrast Flavor 3.0 Increased edge Flavor 3.1 enhancement with Flavor 3.2 higher number Flavor 3.3 Special bone and high Flavor 4.0 Edge enhancement edge flavors Flavor 4.1 conversation does not (Not available for all CIPTs) Flavor 4.2 apply for Flavor 4.x Flavor 4.3 4 Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Flavor – example of a wrist image SIEMENS Healthineers 5 Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Sliders SIEMENS Healthineers The sliders allow the user to fine-tune the image Flavor impression based on a Flavor template, e.g. Flavor 2.2. Clinical Image Processing Task Abdomen • Brightness Flavor Flavor 2.2 makes image brighter or darker. Brightness 0,5 - + • Contrast changes the appearance of black and white. Contrast 0,5 Small Structures - + • enhances the smallest objects of interest. Small Structures O - + • Medium Structures Medium Structures enhances bigger objects based on the CIPT. 0 - + • Dynamic Dynamic changes the dynamic range compression. 0,5 - + • Noise Reduction Noise Reduction is moderately linked to the noise reduction. 0,5 - + 6 Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 How to select the right image impression SIEMENS Healthineers 1 Select the best fitting Flavor. Viewing Tools Clinical Image Processing Task Hand DV • Try different flavor groups (1.x, 2.x or 3.x) with T < Flavor Image Measurement Image 1 Tools Manipulation and Annotation Visualization the focus on global contrast. Flavor 1.1 Brightness 0,5 • Select the best flavor within the group + Flavor X (y.0, y.1, y.2 or y.3) with focus on detail Clinical Task Hand DV Contrast 2 0,5 visibility. Flavor + Flavor 1.1 Brightness 2 Use the sliders on the user interface to adjust the Small Structures 0,5 O image impression. Contrast + 0,5 + Medium Structures Monitor the settings across different patients. Small Structures O 3 + 0 Medium Structures Dynamic 4 Store the slider positions in the corresponding 0 0,5 + Clinical Protocol Steps with the values visible in Dynamic 0,5 Noise Reduction the user interface. 0,5 Noise Reduction + 0.5 + Please note: If the steps above do not improve the desired image impression, please contact your local Siemens Healthineers service organization. 7 Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 What data is required if you contact your local Siemens SIEMENS Healthineers Healthineers organization When contacting your local Siemens Healthineers service organization, please provide the following data: • YSIO X.pree (syngo XR VA10 or VA20): For more information, Please provide at least five different patients for each body part to be Q see pages 9 – 11. optimized. → Exported in Processed and Raw (Backup mode). • If you compare the images to a Siemens Healthineers FLC system: For more information, Please provide at least five different patients for each body part to be Q see page 12. optimized. → Exported in Private and DICOM format. • If you compare the images to a non Siemens Healthineers system: Please provide at least five different patients for each body part to be optimized. → Exported in DICOM format. 8 Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Export images for YSIO X.pree (syngo XR) SIEMENS Healthineers Make sure that the following preconditions are fulfilled: 1. You are logged in as an administrator. Meduser admin2 Check the upper right corner of the screen. If the active user is Meduser, you have no administrator rights. 2. Make sure that the Backup mode option is activated in the Administration Portal. Q For more information, see page 10. 9 Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Enable the Backup mode on YSIO X.pree SIEMENS Healthineers SIEMENS Healthineers .. SIEMENS Healthineers 1 XP-TC-73 / admin2 Free (Restricted Remote Access) Repair Installation 8.ª Technical Configuration Clinical Configuration 1 Make sure that you are logged in as an Site Information Global DICOM Settings Remote Service administrator. Store graphical objects and annotations Licensing User and Role Administration Save as overlay Burn into pixel data DICOM Nodes 2 Enter Administration Portal. Bit depth for RAD images DICOM Data Handling . 16 bit Archiving and Deletion 12 bit Go to Technical Configuration > DICOM Data to be Archived Format for RAD images 3 Autorouting Digital X-Ray Image Storage - For Presentation Computed Radiography Image Data Handling > Global DICOM Settings. Job Settings Backup mode Media Compression 4 Enable Backup mode option Image Rejection Enable the Backup mode option. 3 Contrast/Bolus Agent 4 Global DICOM Settings Auditing to Syslog Server 1. Ionic iodinated contrast agent 2. Barium Sulfate NTP Server 3. Carbon dioxide 5 Click on Save and exit the Administration USB 4. Air Portal by selecting the Logout button. C Gadolinium Tube History 6. Brain Configuration Export-Import + 5 Save 10 Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Processed and Raw (Backup mode) SIEMENS Healthineers admin2 1 Select the patients to be exported. X 2 Click on Export. 2 7 Export 3 Set the target device (e.g. your USB drive). Date of Birth Target Selection USB - JMV 3DTF 3 4 Select the data type Processed and Raw (Backup mode). 1/1/1900 i Target capacity sufficient. 1/1/1900 Format 5 Select Anonymized. DICOM 1/1/1900 Data Processed and Raw (Backup mode) 4 6 Optionally you can enter an anonymization name, 1/1/1900 Compression e.g. CustomerName_Pelvis. 1/1/1900 Add Viewer Click Export. 1/1/1900 7 5 Anonymized as ... Type Service 4/14/2021 New Name CustomerName_Pelvis 6 1/1/1967 After the export you will find a folder called DICOM and a file called 1/1/1967 DICOMDIR on your USB device. 1/1/1967 • Create a new folder on your USB drive. Name this folder clearly and 1/1/1967 move the DICOM folder and DICOMDIR file into the new folder. Clear list • Zip the folder. Please note: Do not make any changes to the folder’s content. 11 Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Export image from a Siemens Healthineers FLC-based system SIEMENS Healthineers 1 Select the Patient tab card. Export × Export X 2 Click on the Export button in the lower right corner. Target Type USB device 4 Target Type USB device Target Target 9 3 Select the patients you would like to export. Format Private 5 Format DICOM 4 Select the target type USB device. Processed Processed Anonymized 6 10 Anonymized M 5 Make sure that you select the format Private. Downsized Downsized Export Dose Report as: Export Dose Report as: 6 Check the Anonymized box. DICOM Dose SR DICOM Dose SR DICOM SC DICOM SC 7 Click on Export. Number of Copies Number of Copies 8 Select the patients again and click on the Export button. Transfer All Transfer All Space: Space: 9 This time, keep the target type USB device, but select the format DICOM. Used: 40% Used: 40% Required: 1% 41% 570374 MB left (excl. 20 MB) 10 Check both checkboxes Processed and Anonymized. Set as Default Set as Default 11 Click on Export. 7 Export Status Close 11 Export Status Close After the export you will find a folder called StudiesPrivate and STUDIES on your USB device. • You can rename this folder to e.g. CustomerName_StudiesPrivate and CustomerName_STUDIES. • Zip the folder. 12 Please note: Do not make any changes to the folder’s content. Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com 13 Effective Date: 05 Jul 2024 | QR700009891 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024
- ysio
- esprit
- xpree
- expree
- how
- stand
- position
- exam
- table
- bucky
- wall
- aim
- plus