YSIO X.pree Detector Calibration (<i>syngo</i> XR) Job Aid

YSIO X.pree Detector Calibration (syngo XR) Job Aid

In this PDF, you will learn about how to calibrate the detector of the YSIO X.pree system.

Target group: Basic user, all users.
Reading duration of this PDF: 23 min.
Recommended to be viewed on the following devices: All (incl. tablet, smartphone).

SIEMENS Healthineers YSIO X.pree Detector Calibration (syngo XR) Job Aid Version 2023.xx Template Effective Date: 10 Aug 2021| HILS 2223 Job Aid Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 YSIO X.pree detector calibration (syngo XR) job aid SIEMENS Healthineers Table of contents General detector calibration information 3 Detector calibration: Portable detector 7 Detector calibration: Fix detector BWS 16 IEMIENS Healthingers .... . 2 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 SIEMENS Healthineers General detector calibration information 3 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 General detector calibration information Always follow the instructions on syngo XR Before calibration of a MAX mini Pixium 2430EZ or • • exactly. X.wi-D 24 detector, the Default Type for Free Exposure in the myExam Cockpit - Detector All mobile detectors of the same type Management must be set to MAX mini or • (MAX wi-D, MAX mini or X.wi-D) except the one X.wi-D 24. to be calibrated have to be disconnected. myExam Cockpit Detector Management Result List Attributes Viewing Workflow Editor Local Data Configurations Client Settings Devices Allowed combinations: 1 MAX wi-D or 1 MAX • Default Type for Free Exposure: O MAX mini O MAX wi-D Details: mini or 1 MAX wi-D + 1 MAX mini or 1 X.wi-D X X No objects may be in the beam path. • MAX static MAX wi-D MAX mini After successful calibration of the detector, the All mobile detectors have to be calibrated in free • • complete system including the imaging system positions. has to be rebooted. The detector temperature must be constant (this is • checked by the system) before the calibration is started. 4 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Preconditions for a successfull detector calibration (1) Portable detectors ✓ YSTO Xper The portable detector must be warmed up for at least 1 hour (battery inserted). ✓ The detector must not have been exposed to radiation for at least 7 hours prior to calibration. ✓ The portable detector must be free of any soiling. ✓ The detector must be calibrated on the floor with SIEMENS Healthineers an SID of 150 cm in the landscape or portrait format. ✓ The detector edges must be overexposed 333333 slightly (about 2 cm; check with the light field). 5 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Preconditions for a successfull detector calibration (2) Fix detectors ✓ The fix Rad detector must be warmed up for at least 1 hour (system switched on). ✓ The detector must not have been exposed to radiation for at least 7 hours prior to calibration. This also applies for previous calibration A procedures. ✓ If calibration fails, a time period of at least 2 hours must expire before calibration can be attempted again. ✓ The tabletop must be centered in the transverse direction. 6 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 SIEMENS Healthineers Detector calibration: Portable detector (X.wi-D, MAX wi-D or MAX mini) 7 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of portable detector System setup YSIO X.pree - This image displays the setup for the detector calibration of a MAX wi-D detector. The same setup also applies for any X.wi-D detector. 8 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a portable detector – Step 1 of 7 Enter the administration SIEMENS admin2 Healthineers portal as clinical admin user. SIEMENS .. Healthineers XP-TC-12 / admin2 Free (Restricted Remote Access) Repair Installation Technical Configuration Clinical Configuration Tune-Up Detector Calibration 1. 1 Navigate to Repair  Configuration Export-Import 1 FD-Calibration Tune-Up  Detector Calibration. Select detector for calibration Calibrate FD Location Serial Number Last Calibration 2. 2 Select the particular Free 23061A 12-07-2023 10:23:23 detector and start the Calibration menu by alibrate FD Location Serial Number Message Wallstand 1527N4 Portable detector can be calibrated only in free! selecting Next. 2 Next Exit o Click a button to proceed V 10:43 13.07.2023 9 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a portable detector – Step 2 of 7 1 The calibration switch must be switched on. (Backside of the Exposure box) - 2 All mobile detectors have to be calibrated on the floor. Do not place the detector directly on - the floor! Center the tube unit to the detector and set the SID specified by the UIS. Calibration of the portable detector is performed in landscape or portrait format. It is mandatory to overexpose the detector (circa 2 cm / 0,8 inch). MAX WI-D Healthineers STOR - suawais O 2 1 CAL 10 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a portable detector – Step 3 of 7 1. 1 Follow the instructions on the imaging system exactly. Once a condition is fulfilled, the red X changes to a green checkmark. 2. 2 If all conditions are met, the Next button appears in the status bar. Select Next then. FD-Calibration FD-Calibration Detector: fd4343ezx Detector position: Free Serial number: 23061A Detector: fd4343ezx Detector position: Free Serial number: 23061A Step 1 of 4 - check FD parameters for calibration Step 1 of 4 - check FD parameters for calibration Align tube to detector and Check that light field is at least 2cm larger than the detector size or fully open collimator Align tube to detector and Check that light field is at least 2cm larger than the detector size or fully open collimator Instruction: Insert 0.6mm Copper into the collimator and assure that no additional objects are in the beam path Instruction: Insert 0.6mm Copper into the collimator and assure that no additional objects are in the beam path Wait while the system verifies all parameters and all checkmarks are green Wait while the system verifies all parameters and all checkmarks are green (2) Parameter Ready Current value Nominal value Remarks Parameter Ready Current value Nominal value Remarks SID n.a. 150.00 cm Align tube and detector with required SID SID 149.41 cm 150.00 cm Align tube and detector with required SID Grid 1 n.a. None Assure that no grid is inserted Grid 1 n.a None Assure that no grid is inserted Temperature constant n.a. 01:00 Wait for the displayed time until the detector temperatur is stable Temperature constant 29.4 ºC 00:00 Wait for the displayed time until the detector temperatur is stable Calibration switch n.a. On Activate the required switch(es) Calibration switch On On Activate the required switch(es) X X X X 2 Exit Next Exit 11 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a portable detector – Step 4 of 7 A status dialog appears when Next is selected. FD-Calibration 1. Select the modes to be Detector: fd4343ezx Free Serial number: 23061A 1 Detector position: calibrated. Step 2 of 4 - select the calibration mode(s) Instruction: Select the mode you want to calibrate 2. 2 To start the calibration, select Mode Select Status Progress Reset Defect Map Go. fd4343ezx_31 1 12-07-2023 10:20 3. 3 Follow the instructions on the imaging system. Alert X 2 X-ray will be automatically released during calibration. Go Exit Ensure that nobody is in the examination room. OK 3 12 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a portable detector – Step 5 of 7 11. Follow the instructions on the imaging system. Insert the 0.6 mm Cu-filter and select OK. SIEMENS XP-TC-12 / admin2 Free (Restricted Remote Access) Healthineers Repair 4 Installation 8.ª Technical Configuration Clinical Configuration SIEMENS Tune-Up Detector Calibration Configuration Export-Import FD-Calibration . 21 0000 - - - - Detector: fd4343ezx Detector position: Free Serial number: 23061A Step 3 of 4 - system calibrates selected mode(s) Instruction: Confirm X H I ? Is the following filter inserted: 0.6 mm Cu 1 Mode Progress fd4343ezx_31 OK Cancel Series 0 of 0 Abort 13 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a portable detector – Step 6 of 7 1. Wait until the calibration is SIEMENS 1 XP-TC-12 / admin2 Free (Restricted Remote Access) Healthineers' Repair Installation &# Technical Configuration Clinical Configuration done. Don‘t enter the room Tune-Up Detector Calibration or interrupt the calibration! Configuration Export-Import FD-Calibration At the end of the calibration, an indicator displays Detector: fd4343ezx Detector position: Free Serial number 23061A whether the calibration was Step 4 of 4 - system has calibrated the selected mode(s) Instruction: Calibration finished, if you want to save the results successful or not. Mode Status Progress fd4343ezx_31 Accepted Acceptance check passed 1 Saving results to detector. 2. Select Save to save the 2 calibration results. 2 Save Next Exit O Click a button to proceed 14 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a portable detector – Step 7 of 7 1. 1 Wait until the saving is done. The progress area will FD-Calibration be updated accordingly. Detector: fd4343rec Detector position: Wallstand Serial number 1920F4 Step 4 of 4 - system has calibrated the selected mode(s) 1. 2 Press Exit to leave the Instruction: Calibration finished,if you want to save the results detector calibration. Mode Status Progress 1 fd4343ezx_31 Accepted Results successfully saved Saving results to detector Disengage the calibration switch and reboot the system. Alert X 2 Please disable calibration switch and for the changes to take effect, reboot the system Save Next Exit OK 15 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 SIEMENS Healthineers Detector calibration: Fix detector (MAX static) 16 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a fix detector (here bucky wall stand) System setup Bald X OISA TTTT 17 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a fix detector – Step 1 of 7 Enter the administration SIEMENS ... Healthineers ? # 2 Meduser portal as clinical admin SIEMENS ... Healthineers XP-TC-73 / Service Technician Siemens (Restricted Remote Access) Diagnosis Repair LeInstallation " Technical Configuration Quality Assurance º Clinical Configuration user. SSD/HDD Repair Access Point Configuration 1 Download FD-Calibration Navigate to Repair  System Configuration Check 1 - System Version Check Tune-Up  Detector Delete Detector Data Fixed FD Assignment Select detector for calibration Calibration Tune-Up Stand Adjustments Calibrate FD Location Serial Number Last Calibration Centering Wallstand 1920F4 21-08-2023 14:32:00 2 Select the particular Camera Calibration - Delete Tube Load Data detector and start the Inverter Adjustment Ca prate FD Location Serial Number Message Tube Adjustment Table 23071D Portable detector can be calibrated only in free! Calibration menu by mAs Adjustment selecting Next. Dose lontomat Detector Calibration 2 Detector Sensitivity & EXI Manual Calibration Configuration Export-Import Export Reports Next Exit 0 Click a button to proceed Service Key Expiry Date: 2023. 09. 26. V 100M 8/29/2023 18 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a fix detector – Step 2 of 7 The calibration switch must be switched on. 1 For Ysio X.pree systems, the SIEMENS - Healthineers calibration switch can be - SNawais STOR found on the backside of the 1 RCM – Exposure box. CAL 19 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a fix detector – Step 3 of 7 1 Follow the instructions on the imaging system exactly. Once a condition is fulfilled, the red X changes to a - green checkmark. 2 If all conditions are met, the Next button appears in the status bar. Select Next then. - SIEMENS Meduser ealthineers ? SIEMENS R Service / IQAP ? Meduser eolthineers 8/29/1983 ? eolthings XP-TC-73 / Service Technician Siemens (Restricted Remote Access) Healthingers> XP-TC-73 / Service Technician Siemens (Restricted Remote Access) V. Diagnosis & Repair Installation Technical Configuration Quality Assurance Clinical Configuration Diagnosis Repair Installation Technical Configuration Quality Assurance Clinical Configuration SSD/HDD Repair SSD/HDD Repair Access Point Configuration Access Point Configuration Download FD-Calibration Download FD-Calibration System Configuration Check System Configuration Check System Version Check System Version Check Delete Detector Data Fixed FD Assignment Detector: fd4343rec Detector position: Wallstand Delete Detector Data Serial number: 1920F4 Fixed FD Assignment Detector: fd4343rec Detector position: Wallstand Serial number. 1920F4 Tune-Up Stand Adjustments Step 1 of 4 - check FD parameters for calibration Tune-Up Stand Adjustments Step 1 of 4 - check FD parameters for calibration Align tube to detector and Check that light field is at least 2cm larger than the detector size or fully open collimator Align tube to detector and Check that light field is at least 2cm larger than the detector size or fully open collimator Centering Centering Camera Calibration Instruction Insert 0.6mm Copper into the collimator and assure that no additional objects are in the beam path Instruction: Insert 0.6mm Copper into the collimator and assure that no additional objects are in the beam path Camera Calibration Delete Tube Load Data Wait while the system verifies all parameters and all checkmarks are green Delete Tube Load Data Wait while the system verifies all parameters and all checkmarks are green Inverter Adjustment Inverter Adjustment Tube Adjustment Paramete Ready Current value Nominal value Remarks Tube Adjustment Parameter Ready Current value Nominal value Remarks mAs Adjustment SID 180.00 cm Align tube and detector with required SID mAs Adjustment SID 180.34 cm 180.00 cm Align tube and detector with required SID Dose lontomat Grid 1 n.a. None Assure that no grid is inserted Dose lontomat Grid 1 None None Assure that no grid is inserted Detector Calibration Detector Calibration Detector Sensitivity & EXI Temperature constant n.a. 01:00 Wait for the displayed time until the detector temperatur is stable Detector Sensitivity & EXI Temperature constant 32.8 . 00:00 Wait for the displayed time until the detector temperatur is stable Calibration switch na Manual Calibration On Activate the required switch(es) Manual Calibration Calibration switch On On Activate the required switch(es) Configuration Export-Import Configuration Export-Import Export Reports Export Reports 2 Exit Next Exit D Loading UI Service Key Expiry Date: 2023. 09. 26. XX1 0 Performing preparation checks. Service Key Expiry Date: 2023. 09. 26. 1:02 PM V 1:03 PM 3/29/2023 20 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a fix detector – Step 4 of 7 A status dialog appears when Next is SIEMENS .. Service / IQAP Meduser Healthineers 8/29/1983 ? ? XP-TC-73 / Service Technician selected. leolthineers> Siemens (Restricted Remote Access) - Diagnosis Repai Installation Technical Configuration Quality Assurance Clinical Configuration SSD/HDD Repair Access Point Configuration Download FD-Calibration 1 Select the modes to be calibrated. System Configuration Check - System Version Check Delete Detector Data Fixed FD Assignment Detector: fd4343rec Detector position: Wallstand Serial number 1920F4 Tune-Up Stand Adjustments Step 2 of 4 - select the calibration mode(s) Centering nstruction: Select the mode you want to calibrate 2 To start the calibration, select Go. Camera Calibration - Delete Tube Load Data Mode Select Status Progress Reset Defect Map Inverter Adjustment fd4343rec_31 1 21-08-2023 14:31 Tube Adjustment mAs Adjustment Dose lontomat Detector Calibration 3 Follow the instructions on the Detector Sensitivity & EXI - Manual Calibration imaging system. Configuration Export-Import Export Reports 2 Go Exit 0 Click a button to proceed Service Key Expiry Date: 2023. 09. 26. V 2 1:05 PM Alert X X-ray will be automatically released during calibration. Ensure that nobody is in the examination room. OK 3 21 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a fix detector – Step 5 of 7 1- Follow the instructions on the imaging system. Insert the 0.6 mm Cu-filter and select OK. SIEMENS. Healthineers AR Service / IQAP Meduser 8/29/1983 ? SIEMENS Healthineers. XP-TC-73 / Service Technician Siemens (Restricted Remote Access) Diagnosis Repair Installation º Technical Configuration O Quality Assurance Clinical Configuration SSD/HDD Repair Access Point Configuration Download FD-Calibration System Configuration Check System Version Check Delete Detector Data Fixed FD Assignment Detector: fd4343rec Detector position: Wallstand Serial number 1920F4 Tune-Up Step 3 of 4 - system calibrates selected mode(s) Stand Adjustments Centering Instruction: Confirm X Camera Calibration Delete Tube Load Data ? Is the following filter inserted: 0.6 mm Cu Inverter Adjustment Mode 1 rogres Tube Adjustment OK Cancel fd4343rec_31 eries 0 of 0 mAs Adjustment Dose lontomat Detector Calibration Detector Sensitivity & EXI Manual Calibration Configuration Export-Import Export Reports Abort @ Setting CP step Service Key Expiry Date: 2023. 09. 26. XX1 V 2 1:07 PM 8127 23 22 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a fix detector – Step 6 of 7 1 Wait until the calibration is - done. Don‘t enter the room FD-Calibration or interrupt the calibration! At the end of the Detector: fd4343rec Detector position: Wallstand Serial number: 1920F4 calibration, an indicator Step 4 of 4 - system has calibrated the selected mode(s) displays whether the Instruction: Calibration finished,if you want to save the results calibration was successful Mode Status Progress fd4343rec_31 Accepted Acceptance check passed 1 or not. Saving results to detector: 2 Select Save to save the - calibration results. 2 Save Next Exit 23 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 Calibration of a fix detector – Step 7 of 7 1 Wait until the saving is FD-Calibration - done. The progress area will be updated accordingly. Detector: fd4343rec Detector position: Wallstand Serial number: 1920F4 Step 4 of 4 - system has calibrated the selected mode(s) Instruction: Calibration finished,if you want to save the results 2 Select Exit to leave the Mode Status Progress - detector calibration. fd4343rec_31 Accepted Results successfully saved 1 Saving results to detector: Disengage the calibration switch and reboot the system. 1 Alert X 2 Save Next Exit Please disable calibration switch and for the changes to take effect, reboot the system OK 24 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthineers AG 2023 Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim, Germany Phone: +49 9191 18-0 siemens-healthineers.com 25 Effective Date: 01 Dec 2023 | QR700002115 Unrestricted © Siemens Healthineers AG, 2023

  • ysio
  • esprit
  • xpree
  • expree
  • syngo
  • snygo
  • xr
  • va20
  • how
  • calibrat
  • detector