
What’s New in MR syngo.via VC10
This job aid provides an overview of the latest updates in syngo.via VC10 for MR reading, highlighting key enhancements and new features. It is designed to help users navigate the changes and make the most of the new functionalities.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet and smartphone)
SIEMENS Healthineers What’s New in MR syngo.via VC10 Template Effective Date: 26 Mar 2025 | QR700020784 1 Job Aid Effective Date: 19 May 2025 | QR700023491 This training material is based on the medical devices syngo.basic VB60J and syngo.MR Applications VC10A. Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Disclaimer SIEMENS Healthineers syngo.via Q Scanner AI-Rad Companion V syngo.via Syngo Carbon View&GO Space Please keep in mind that the user interface may differ slightly from what is shown in this Job Aid. The actual usage of the tool may differ slightly on the different host systems, for example on syngo.via, Syngo Carbon Space, syngo.via View&GO, AI-Rad Companion or on the scanner. The tool functionality defined in this Job Aid is applicable to any of the Siemens Healthineers products in which you find this tool. Template Effective Date: 26 Mar 2025 | QR700020784 2 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Table of Contents Introduction 4 Consolidation of MR Workflows 6 MR Cardiac Workflow 9 MR Layout Migration Tool 17 Enhancements in TimeCurve 28 Enhancements in MR Breast layouts 32 Enhancements in MR General Tools 35 Enhancements in MR Spectro 39 Enhancements in MR Tissue4D 41 Template Effective Date: 26 Mar 2025 | QR700020784 3 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Introduction Template Effective Date: 26 Mar 2025 | QR700020784 4 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Introduction Viewing HR Purpose Viewing MR spine The following educational content guides you through the most relevant updates from syngo.via VB80A to VC10A for the MR reading. Some of the updates explained here may already Favorite Tools HL HL be available in certain VB80x software versions MR Cardiac X AHR Function Anal ... + X released after VB80A. ? O U OpenApps Quick Distance ROI Circle Sectorg Guide Line E Normal Mancal Create RFA Export Mode Findings Ranges Image Refine Segmentation Full Text Hide Lines S Reset Layout LV Endo LVEpi ITV Endo 10 20 30 10 50 60 70 50 50 1 O ED 32 184 275 2665 452 551 642 734 826 978 18888868 Fen Circle LVIRV Thickening Control Freshand Point Edit Edit + LV LV NORM AV AV NORM Deless Delete All Adiat 69.97 81.07 ESVml) 02.10 32.0 Favorite Tools X 93.15 CO(U/min) 8 87 3.1 140.32 77 22 MM Avg(a) 152.04 MMM SO(a) 504 2.68 Une 6. 3 RFA RFA RFA E E AII RH Template Effective Date: 26 Mar 2025 | QR700020784 5 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Consolidation of MR Workflows Template Effective Date: 26 Mar 2025 | QR700020784 6 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Consolidation of MR Workflows (I) MM Reading Workflow The following MR workflows, along with all their copies, are now consolidated in the MM Reading Workflow: Viewing . Viewing • MR Basic Workflow • MR Whole Spine Workflow • MR Breast Workflow Viewing Viewing Favorite Tools MR spine Consequently, these workflows and all their O copies are no longer available. Op QUICT Distance BOI Crcte Viewing Ch º X Hoe Lines · Viewing All functionality has been migrated to MM MR breast ME Breast WK Breast Dynamic Morphal .. 212 Reading. You must use this workflow for the MR Favorite Tools reading that you previously performed with Synch 30 %at ? O those discontinued workflows. OpenApps Quick Datance ROI Circle Guide Line Full Text Hide Lines Reset Layout Favorite Tools With the MM Reading Workflow, built on the Foire One Viewer technology, you can experience the O + OpmA Distance 80I Crcte Cuide streamlined efficiency of the consolidation of Fring these MR reading tasks. Hoe Lines Spinerbe Late Template Effective Date: 26 Mar 2025 | QR700020784 7 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Consolidation of MR Workflows (II) Viewing The studies previously mapped to one of the Viewing Viewing TimeCurve discontinued workflows are now automatically MR general 1 2 Viewing mapped to the MM Reading Workflow. In the CR-DR-DX general MR spine XA general MM Reading Workflow, you can use: Min/ Ms< 3 00 11136 00 AzanISO 718 589293:14 MR spine Area: 140cmz MR Sur 97005:00 MR Spine Spine Result 13 Frh MR angio Compos. 2x2 MR breast 1 • Viewing protocols (layout collections), MR general based on the discontinued workflows. MG general US general These protocols contain the user layouts Molte This 230.65 sec Mout 914:28 PT-CT general that you used to have (*). 2 • 4 TimeCurve tool, instead of the 3 MeanCurve layout. Layout Editor Single Click 3 • Single Click tool, available in the Tool . Layout Editor Gallery. + 5 Magnifier 4 • Layout Editor tool, to create and customize layouts in an intuitive and friendly way. Favorite Tools O 5 • And other tools such as Smart Select or IT the Magnifier. Template Effective Date: 26 Mar 2025 | QR700020784 8 Job Aid Effective Date: 19 May 2025 | QR700023491 (*) You must manually migrate those layouts using the Layout Migration Tool. Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers MR Cardiac Workflow Template Effective Date: 26 Mar 2025 | QR700020784 9 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Cardiac Workflow (I) Open with Favorites All functionality of the MR Cardiac Analysis View as Read-Only with · Suggested Batch Open MM Reading Workflow has been migrated to the MR Cardiac Assign Workflow MM RT Image Suite Workflow. Use this new workflow when Group Studies MR Angiography evaluating MR cardiac studies. Batch Assign Workflow MR BreVis Cancel Workflow MR Cardiac With the MR Cardiac Workflow, built on the One MR Cardiac RealTime Segmented AHR AHR Viewing Viewer technology, you can experience the MR Cardiac 1.2 Stack za Funds streamlined efficiency and the versatility given by Dynamic-1 RFA RFA RFA One Viewer. Flow Myomap ... YOUARE MPR 30 You can now use tools such as Smart Select, the Function Analysis Flow Quant AHR AHR AHR Magnifier and the Layout Editor. Perfusion Analysis .2ª RFA RFA. RFA- Favorite Tools X Creat Function Flow Cardi. Analysis Quantific .. Perfusion Analysis tealTime Segmented HLP O Synch JEF Snapthoe Export RHA RHA AL Template Effective Date: 26 Mar 2025 | QR700020784 10 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Cardiac Workflow (II) MR Cardiac Analysis WF MR Cardiac WF Find the previous MR Cardiac Reading step of MR Cardiac Reading MR Cardiac Viewing protocol the MR Cardiac Analysis Workflow now in the Viewing panel. Select the MR Cardiac Viewing MR Cardiac Analysis + MR Cardiac RealTime H Segmented AHR AHR protocol. The different sub-steps are simple MR Cardiac Reading - Viewing MR Cardiac layouts. . 2 E Stack 2x2 Function ... Dynamic-1 Learn Create Segments Findings RFA RFA RFA Flow Myomap. Go to the Viewing panel and select the Overview Myomaps MPR 3D corresponding layout from the MR Cardiac Functional Dynamic Viewing protocol: >Function Analysis Tissue Characterization Flow Quant AHR AHR AHR Combined · Perfusion Analysis • Stack 2x2 Flow Myomaps • Functional-1 RFA RFA RFA Favorite Tools X • Dynamic-1 E Create Function Flow Cardi ... Analysis Quantific ... • DE Perfusion RealTime Segmented AF HLP • Flow Synch Distance ROI Circle Line Snapshot Print Export 2,3 • MyomapsT1 Image Image RHA RHA AL • Myomaps Combined • MPR 3D (new) + Template Effective Date: 26 Mar 2025 | QR700020784 11 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Cardiac Workflow (III) MR Cardiac Analysis WF MR Cardiac WF The MPR 3D layout is new. MR Cardiac Reading MR Cardiac Viewing protocol Example use cases: MR Cardiac Analysis + MR Cardiac HAL HAR MR Cardiac Reading Viewing • 3D whole heart imaging. MR Cardiac E • 3D delayed enhancement imaging. Stack 2x2 Function ... Dynamic-1 Learn Create Segments Findings Flow Myomap Overview This layout is similar to the MPR 3D layout Myomaps RAI Functional OH Combined available in other workflows. Dynamic Function Analysis Tissue Characterization › Flow Quant Combined · Perfusion Analysis The ranges functionality is available, as in other Flow Myomaps MPR 3D layouts. Favorite Tools X AFR E Create Function Flow The Create Cardiac Finding button is available, Cardi ... Analysis Quantific ... Perfusion featuring the AHA model to document the results of visual analysis. Synch Distance ROI Circle Line RHA Snapshot Print Export Image Image Activa + Template Effective Date: 26 Mar 2025 | QR700020784 12 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Cardiac Workflow (III) MR Cardiac Analysis WF MR Cardiac WF The previous MR Cardiac Function step of the MR Cardiac Function Function Analysis MR Cardiac Analysis Workflow is now the Function Analysis panel. MR Cardiac Analysis MR Cardiac Q o X AHR Function Anal ... # X 160 0.00 m 144 0.00 The analysis tools of the left ventricle (LV) and 128 0.00 Hide Lines Sectors Reset Reset Normal Manua Hide Lines Sectors 112 0.00 Mode Mode Create Findings 96 0.00 the right ventricle (RV) are consolidated in the 80 0.00 LV Analysis Normal Manual Create RFA RFA 64 0.00 Mode Mode Findings 48 0.00 Refine Segmentation Refine Segmentation 32 0.00 same area. 16 0.00 O O. LV Endo LV Epi RV Endo 0.00 Endo Pen Circle Nudge 10 20 30 40 50 60 70 80 90 100 % ED 92 184 275 67 459 551 642 734 826 918 ms RV Epi Pen Circle Control Freehand Delete Delete All Adjust Point Edit Edit AF AF LVIRV Thickening Nudge Control Freehand Point Edit Edit Propagate ED/ES Join Guidance Cardiac Function LV LV NORM unitime RV unitime 5. 3 EF(%) 59.97 RV Analysis V II EDV(ml) 155.33 81.97 RHA Favorite Tools RHA ESV(ml) 62.16 32.81 X SV(ml) 93. 1 40.10 Co(l/min 5.87 3.1 Analyze Quantile MM ED(g) 146.32 77.22 MM ANO(O) 152 04 80.72 Perfusion Scroll Rlocate MM SD(g) 5.04 2.00 Analysis O. Function Synch Distance ROI Circle Line 6 3 6. 3 Analysis RFA RFA RFA RFA RFA RFA Starting Function Analysis Snapshot Print Export image Image ED You can start it by clicking the Function Full Text Hide Lines E EAII Analysis icon in the Favorite Tools panel. H. RHA RHA AL jease drog data from Series Navigatorlease drag data from Series Navigatorlease drag data from Series Navigator Template Effective Date: 26 Mar 2025 | QR700020784 13 Job Aid Effective Date: 19 May 2025 | QR700023491 syngo.MR Cardiac 4D Ventricular Function is not available in syngo.via VC10A. Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Cardiac Workflow (IV) MR Cardiac Analysis WF MR Cardiac WF The previous MR Flow Quantification step of the MR Flow Quantification Flow Quant MR Cardiac Analysis Workflow is now the Flow Quant panel. MR Cardiac Analysis MR Cardiac Q o X AF Flow Quant X Vida_Heart ACH Vida_Heart ACH + "1/1/2005, M. *1/1/2005, M. 14Y E emoCongress Ref.: DemoCongress 5/8/2019 GNETOM Vida 5/8/2019 MAGNETOM Vida MR Cardiac Function The option Invert Polarity is now available. Create Findings _flow_150_AA DATE 1, 3 flow_150_AA 1. 3 MR Flow Quantification Vessel Segmentation STUDY ID 3aaaa1193 latest/MAG 3:43:08 PM STUDY ID 3aaaa1193 63 IMA 1 FRM 3/30 3:43:08 PM 62 IMA 1 FRM 3/30 ROM Vessel Segmentation Avg : 56.57 cm/s E ROIT RO12 RFP RFP Pealt : 77.34 cm/s Flow : 296.47 ml/s Create O SL Findings F SL 5.0 Area : 5.24 cm2 F O One Click Circle + 42.13 cmit O Segment. SP H59.1 SP H59.1 TT 66.4 ROIT ROI3 Area - 85 cm2 FOV 260*260 TT 66.4 FoV 260*260 ROI2 Vessel Segmentation TR 39.8 144*192 TR 39.8 144*192 Nudge Adjust TE 2.8 Tra Sag(30)>Cor(1) TE 2.8 Tra>Sag(30)>Cor(1) W C TA 16.96 W 4648 135 O O p2 PHASE/VELOCITY/PIRETRO/DIS2D -212 TA 16.96 p2 MAGN/T1/M/RETRO/DIS2D 49 O + ROI1 RO12 ROI3 ROI4 RR 996 +/-66, ... RR 996 +/- 66; 18 heartbeats RO14 One Click Circle Invert Delete Delete All Contrast agent Contrast agent Polarity Segment. O O R O+ Flow Peak-Vel Vel Net Flow Area ROI3 RO14 AF circle Nudge Adjust One Click Vida_Heart ACH Segment. V II *1/1/2005, M, 14Y Ref.: DemoCongress mi/s 5/8/2019 MAGNETOM Vida Pen Nudge Adjust FO 407 Favorite Tools X flow_150_AA 342 latest/MAG 276 STUDY ID 3aaaa1193 211 3:43:08 PM 146 62 IMA 1 FRM 8/30 ROM Analyse Quantile Avg : 42.71 cm/s Invert Delete Delete All 80 RFP Peak : 88.18 cm/s Flow : 268.4 muis Polarity 15 Perfusion Scroll -50 SL 5.0 Area : 6.28 cm2 Rocate Analysis -116 SP H59.1 O. -181 TT 232.4 FoV 260*260 Synch Distance ROI Circle -246 100 TR 39.8 144 192 Flow Line 10 30 70 TE 2.8 Tra>Sag(30)>Cor(1) W 143 Quantific ... 96 209 385 578 674 720 867 963 TA 16.96 C 52 Snapshot p2 MAGN/T1/M/RETRO/DIS2D RR 996 +/- 66, 18 heartbeats Starting Flow Quant Print Export Start End Image Image Contrast agent Peak-Vel Forw-Volume Rev- Volume Avg-Flow/Min You can start it by clicking the Flow Full Text Hide Lines ROM 108.838 85.007 0.00 5.096 Quantification icon in the Favorite H. -123.633 0.479 54.397 3.235 REP RFP Fi Please drag data from Series Navigate ROI3 Tools panel. SPH591 SP H59.1 + RO14 Template Effective Date: 26 Mar 2025 | QR700020784 14 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Cardiac Workflow (V) MR Cardiac Analysis WF MR Cardiac WF The previous MR Cardiac Perfusion step of the MR Cardiac Perfusion Perfusion Analysis MR Cardiac Analysis Workflow is now the Perfusion Analysis panel. MR Cardiac Analysis MR Cardiac Co x AHR Viewing MR Cardiac Function Function Analysis Flow Quant MR Flow Quantification Perfusion Analysis X . 1.2 OO MR Cardiac Perfusion E Create Findings E Rest-Stress Viewing Create RFA Findings Motion Correction QA Time Course Analysis Rest-Stress Viewing Motion Correction QA Piel Of Show Interest Sectors Time Course Analysis Pixel of Show V II Interest Sectors Favorite Tools X AHR AHR AHR 4, 3, Analyze Quantile RFA RFA RFA 39 Perfusion Scroll Analysis 35 Synch Distance ROI Circle Perfusion Line lease drag data from Series Navigatorease drag data from Series Navigatoriease drag data from Series Navigator 21 Starting Perfusion Analysis Analysis Snapshot Print Export Image Image 17 Upslope TTP AUC Peak 12 You can start it by clicking the Perfusion Full Text Hide Lines 3.43 6.11 42.73 20 Analysis icon in the Favorite Tools panel. H. 4.48 8.39 142.3 37 POI 3 13 17 22 26 31 35 39 44 + POI 4 Template Effective Date: 26 Mar 2025 | QR700020784 15 Job Aid Effective Date: 19 May 2025 | QR700023491 syngo.MR Cardiac Perfusion is not available in syngo.via VC10A Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Cardiac Workflow (VI) MR Cardiac Analysis WF MR Cardiac WF The previous MR Angiography Reading Ad-hoc MR Angiography Reading MR Angio Viewing protocol task, that you could add to the MR Cardiac -----.-.- Analysis Workflow, is now in the Viewing panel. MR Cardiac Analysis MR Cardiac Q.X Simply select the MR Angio Viewing protocol Viewing MR Cardiac Reading MR Angio and choose the desired layout. MR Angio MR Angio MR Angio Overview 2.3 Multi Twist Functional Dynamic Function Analysis Tissue Characterization Flow Quant Combined Flow Please drag data from Series Navigator Myomaps MR Angiography Reading Favorite Tools MR Cardiac Function - 8 Create Function Cardi ... Analysis Q MR Flow Quantification Analysis MR Cardiac Perfusion ROI Card Please drag data from Series Navigator. Full Text Hide Line Please drag data from Series Navigator. Template Effective Date: 26 Mar 2025 | QR700020784 16 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers MR Layout Migration Tool Template Effective Date: 26 Mar 2025 | QR700020784 17 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Layout Migration Tool (I) SIEMENS Healthineers syngovia / adminuser Free (Full Access) ? C The MR Layout Migration tool allows you to Installation Technical Configuration Clinical Configuration migrate the existing layouts of a discontinued MR Administrat ... workflow to the workflow in use. Portal Workflow Assignment MR Layout Migration > Data Preprocessing 1 During the layout migration process, public and user layouts of the discontinued workflows • You can migrate layouts from the MR will be migrated. Basic Workflow, MR Breast Workflow, Patient Browser MR Whole Spine Workflow, or from any Prior Study Search MR Hand of their copies, to the MM Reading Real-time data exchange MR Elbow Workflow. > Reading MR Knee • You can migrate layouts from the MR Study Preloading Prediction MR Liver Cardiac Analysis Workflow to the MR Reporting MR Mammo Cardiac Workflow. > DICOM Data Handling MR Shoulder > Licensing MR Spine Dr Doe The MR Layout Migration tool is available in the MR Workflow Management MRBasic Administration Portal, in the Clinical Layout Management Configuration, and only to the following user MRBreast User and Role Administration roles: MRWholeSpine Expert-i • MRCardiacAnalysis Clinical Administrator MR Layout Migration • IT Administrator Choose Layouts À OXX 10F Template Effective Date: 26 Mar 2025 | QR700020784 18 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Layout Migration Tool (II) 1 SIEMENS .. Healthineers syngovia / adminuser Free (Full Access) ? C To use the MR Layout Migration tool, follow the Installation Technical Configuration Clinical Configuration 2 next steps: Administrat ... Portal Workflow Assignment MR Layout Migration 1 • Log on to the Administration Portal. > Data Preprocessing 1 During the layout migration process, public and user layouts of the discontinued workflows will be migrated. Patient Browser 2 • Select the Clinical Configuration Prior Study Search MR Hand 4 workspace. Real-time data exchange MR Elbow > Reading MR Knee 3 • Choose MR Layout Migration (only Study Preloading Prediction MR Liver available for Clinical Administrator or IT Reporting Administrator users). MR Mammo > DICOM Data Handling MR Shoulder > Licensing 4 • Select the desired discontinued workflow. MR Spine Dr Doe MR Workflow Management MRBasic 5 • Layout Management Click the Choose Layouts button. MRBreast User and Role Administration MRWholeSpine Expert-i MRCardiacAnalysis MR Layout Migration 3 Choose Layouts 5 À OXX 10F Template Effective Date: 26 Mar 2025 | QR700020784 19 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Layout Migration Tool (III) SIEMENS Healthineers syngovia / adminuser Free (Full Access) ? C 6 • If the workflow you selected does not Installation Technical Configuration Clinical Configuration contain any layouts, you are informed. Administrat ... Portal Workflow Assignment MR Layout Migration > Data Preprocessing 1 During the layout migration process, public and user layouts of the discontinued workflows will be migrated. Patient Browser Prior Study Search MR Hand Real-time data exchange MR Elbow > Reading Study Preloading Prediction Information 6 Reporting > DICOM Data Handling 1 Layouts not available to migrate! > Licensing OK MR Workflow Management MRBasic Layout Management MRBreast User and Role Administration MRWholeSpine Expert-i MRCardiacAnalysis MR Layout Migration Choose Layouts À OXX 10F Template Effective Date: 26 Mar 2025 | QR700020784 20 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Layout Migration Tool (IV) SIEMENS Healthineers syngovia / adminuser Free (Full Access) EX ? C 7 • Otherwise, the list of the corresponding Installation Technical Configuration Choose layouts public layouts is displayed. X Administrat ... Portal Workflow Assignment MR Layout Mi • During t 1 The application adds the suffix > Data Preprocessing All user layouts will be migrated automatically. 9 8 L will be n _WorkflowName to all the layouts that Patient Browser Please select public layouts to migrate: 7 you may migrate. Prior Study Search MR Hand Stack 1x1 MR Hand Real-time data exchange Stack 2x2 MR Hand MR Elbow Stack 3x3 MR Hand 9 • The private layouts of that workflow are > Reading Stripe 2x2 MR Hand MR Knee Stripe_3x3 MR Hand not listed. Thus, they automatically Study Preloading Prediction Stripe 4x4 MR Hand 8 migrate as soon as any of the public MR Liver Dynamics 40| MR Hand Reporting Compare_2x2 MR Hand layouts of that workflow migrates. MR Mammo 4D_1x1 MR Hand > DICOM Data Handling MPR 3D MR Hand MR Shoulder Compare_MPR MR Hand > Licensing Meancurve MR Hand 10 • Select the desired layouts that you want MR Spine Dr Meancurve 2x2 MR Hand MR Workflow Management Alignment_MR Hand 10 to migrate. You can use the Ctrl key or the MRBasic Easy_Reading_MR Hand Results 2x2 MR Hand Shift key to select multiple layouts. Layout Management MRBreast MPR Hand MR Hand User and Role Administration MRWholeSpin 11 • If you defined taskflows in the Expert-i MRCardiacAn 11 discontinued workflow, navigate to the MR Layout Migration 12 Migrate next pages to select their layouts. Choose Lay 12 • Click the Migrate button. Template Effective Date: 26 Mar 2025 | QR700020784 21 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Layout Migration Tool (V) SIEMENS Healthineers syngovia / adminuser Free (Full Access) 13 • Before starting the migration, the MR 4 Installation Technical Configuration 28. Clinical Configuration Choose layouts X Layout Migration tool reminds you to Administrat ... close all instances of the destination Portal Workflow Assignment MR Layout Mi workflow. The destination workflow must > Data Preprocessing 1 During t 1 All user layouts will be migrated automatically. will be m be closed in all clients. Patient Browser Please select public layouts to migrate: Prior Study Search MR Hand Stack_1x1_MR Hand 14 • If the destination workflow is closed in all Real-time data Stack 2x2 MR Hand 13 syngo.via clients, confirm the start of the > Reading Confirmation X migration process with OK. Study Preloadir Reporting The selected layouts and all private layouts of the ? Please close all the MM Reading instances to continue with the layout > DICOM Data He migration. Click OK to proceed with the migration. selected workflow are now set to migrate. > Licensing 14 Cancel OK MR Workflow M Layout Management Results 2x2 MR Hand MRBreast MPR_Hand MR Hand User and Role Administration MRWholeSpin Expert-i MRCardiacAn MR Layout Migration Migrate Choose Lay Template Effective Date: 26 Mar 2025 | QR700020784 22 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Layout Migration Tool (VI) Information The MR Layout Migration tool provides you 1 feedback about the migration result. 1 Layout migration successful! 1 • All the selected public layouts and the OK corresponding private layouts migrate successfully. 2 • All selected public layouts and the Information 2 corresponding private layouts migrate successfully. However, the properties not Layout migration partially successful, please check the logs at supported in the destination workflow do 1 C:\Storelog\MRLayoutMigration not migrate. OK 3 • None of the layouts migrate. You must open the destination workflow at least Information once before executing the migration. 3 Migration failed. You must claim the workflow before proceeding H. OK Template Effective Date: 26 Mar 2025 | QR700020784 23 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Layout Migration Tool (VII) • Information None of the layouts migrate. 4 4 • 5 None of the layouts migrate. The i Layout migration failed, please check the logs at configuration file is too large. You cannot c:\store\Log\MRLayoutMigration migrate all those layouts to the destination workflow. OK Information 5 Configuration is not saved since the size (1075 KB) of the configuration item 'Data' exceeds the maximum limit of '1' MB. Layout migration failed, H. please check the logs at c:\store\Log\MRLayoutMigration OK Template Effective Date: 26 Mar 2025 | QR700020784 24 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Layout Migration Tool (VIII) Configuration ? Assign Layouts x In the MM Reading Workflow: Layouts Series Presets i For a study specified by modality and assignment condition, please drag the layouts to the Preferred Layouts section. The first layout in the list will be your initial layout. State Modality Protocol Name Assignment Object | Assignment Condition |Public Protocol Name 1 • The MR Layout Migration tool creates a Viewing CR-DR-DX general Study Description 3 Q Search 1 XA MR Han XA general Study Description Viewing new Viewing Protocol (layout collection) MR MR Hand Study Description *Hand* Modality Public Layouts MR Hand MR MR spine Body Part Examined "SPINE" MR with the former name of the discontinued MR angio MPR_Ha ... Stack 1x1 Stack 2x1 Stack 2x2 Stack 3x2 Stack 3x3 angio* MPR Ha ... MR Study Description Assignment Object Hand Hand MR MR breast Body Part Examined *Breast* Study Description workflow. MR MR general Study Description Stack 4x4 Stack 5x5 Follow Up Follow Up Follow Up MPR Assignment Condition 2TP 3TP 4TP Follow ... 2 *Hand* MG 2x2 PET CT MR CT Stripe 3x3 MPR MPR VRT Compare Standard Preferred Layouts MPR 20 M 2 • The Viewing Protocol contains all Head Hand Results migrated layouts of the corresponding Lung 2 Results MR Angio discontinued workflow. MR Angio MR Angio MR Spine MR MR Breast MR Breast Multi Twist Compos ... Dynamic Morphol ... 3 • The Workflow Assignment Rules of the Favorite Tools H discontinued workflow are migrated to X the corresponding Viewing Protocol. Scroll Rotate Synch ... ? 30 Re OpenApps Quick Guide When you open the MM Reading Workflow, the Distance ROI Circle Parallel Line Ranges corresponding Viewing Protocol with its A R Snapshot Print Export preferred layout automatically selects. Image Image Full Text Hide Lines Spine/Rib Label L L Reset AUTO Layout Views + Template Effective Date: 26 Mar 2025 | QR700020784 25 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Layout Migration Tool (IX) MR Cardiac AH LH If the destination workflow is the MR Cardiac Viewing 4 Workflow: Flow Quant 4 • The MR Layout Migration tool does not Function Analysis create a Viewing Protocol. HAR In this case, the MR Cardiac Workflow is not a destination workflow for different discontinued workflows. It is only for the MR Cardiac Analysis Workflow. Therefore, the MR Layout Migration tool does not create Viewing Protocols. Favorite Tools X HLP HLP E Create Function Flow Cardi ... Analysis Quantific .. Perfusion Scroll Analysis Synch Distance ROI Circle Line Snapshot Print Image PRH PRH Full Text Hide Lines + Template Effective Date: 26 Mar 2025 | QR700020784 26 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers MR Layout Migration Tool (X) The MR Layout Migration tool has some limitations: • Before you migrate any layout, you must open the corresponding destination workflow at least once after installation. • During the migration process, you must close any instance of the destination workflow across all clients. • The maximum size allowed for the layout configuration file of the destination workflow is 1 MB, hence there is a limit on the migration of layouts. • The destination workflow supports only Study Description and Body Part Examined as configuration parameters of the Viewing Protocol. Therefore, only these assignment conditions are supported when converting the Workflow Assignment Rules to the Viewing Protocols. • The layouts defined in the taskflows MR Neurology Reading, MR Oncology, MR Tissue4D Analysis and MR Prostate Reading within the discontinued workflows are not listed in the MR Layout Migration tool. Therefore, they will not migrate. • There are some MR dedicated properties that are not supported in the destination workflow. Therefore, these are not migrated: • Synchronization Reference Line is not supported. • Not supported type of alternative Equality::**BasicMeanCurve_Results*. • Not supported type of alternative RegularExpression::%TP1%.3D. • Image segments associated with MeanCurve properties or Isotropic drag and drop properties are not supported. • Synchronization based on Best Match Provider with Phase Coherence feature is not supported (synchronizations implemented in discontinued MR Breast workflow). Template Effective Date: 26 Mar 2025 | QR700020784 27 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Enhancements in TimeCurve Template Effective Date: 26 Mar 2025 | QR700020784 28 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Enhancements in TimeCurve (I) AF Dynamic AF You can define regions of interest in 2D data groups (non-dynamics) displayed in the image segments of the MR dedicated layouts. The TimeCurve propagates automatically these RHA regions of interests to the Dynamic image RHA TC1 2 TC1 1 segment. Min / Max: 107.00 /835.00 Min / Max: 619.00 /1302.00 Mean/SD: 457.49 /210.78 Mean/SD: 893.92 /213.53 Area: 0.36 cm2 Area: 0.36 cm2 Sum: 46206.00 Sum: 10727:00 101 Pixels 12 Pixels For example: 1 • Draw a region of interest on an ADC map. AF 3 TC1 Normal Time: 29.72 sedvean: 457.49 Ratio: 403.5 % 2 • This region of interest automatically Mean (%) 450 propagates to the dynamic data being 400 evaluated in TimeCurve. 350 300 250 3 • The corresponding curve is then displayed RHA 200 in the result segment. 150 100 50 0 25 50 75 100 125 150 175 Time Offset: 0 sec Normal Time (sec) Template Effective Date: 26 Mar 2025 | QR700020784 29 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Enhancements in TimeCurve (II) HPR 1 Dynamic H You can evaluate Test bolus data sets using the TimeCurve tool. TC1 Min / Max: 81.00 /124.00 Mean/SD: 109.33 /9.81 1 • The Test bolus data group loads in the Area: 3.63 cm2 Sum: 16399.00 150 Pixels 2 Dynamic segment. RA R 2 • Draw a region of interest. 3 • The corresponding curve is available in the result segment. 3 TC1 Normal Time: 18.05 sedvean: 109.33 Ratio: 67.68 % Mean (%) 1 75 50 25 Please drag data from Series Navigator. .25 -50 -75 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 O Time Offset: 0 sec Normal Time (sec) Template Effective Date: 26 Mar 2025 | QR700020784 30 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Enhancements in TimeCurve (III) Dynamic data are not within one series block 16 t1_vibe_fs_tra_p4_bh_delay You can now perform the dynamic evaluation of If the dynamic data are not within the same series block, you 15 t1_vibe_fs_tra_p4_bh_venos data that are not within the same series block: need to Create Dynamic 4D after starting the TimeCurve tool. 14 t1_vibe_fs_tra_p4_bh_arteriel H. 11 t1_vibe_fs_tra_p4_bh_pre 1 • Check the TimeCurve layout. TimeCurve Dynamic Series Check that the automatic selected layout O meets your needs. Otherwise, select TC-Circle TC-Pixel TC- TC 2 Lens Freehand Snapshot Series Name another layout from the available ones. Basic Multi 1 Please drag data from Series Navigate Please drag data from Series Navigator. 7/24/2018 paramet. MR, Tumor_CE BLADE BO18ch SP32ch Brain Insert Before 16 t1_vibe_fs_tra_p4_bh_delay Create Dynamic 4D 15 t1_vibe_fs_tra_p4_bh_venös • Create Dynamic 4D. Breast Create 2D Stack 14 t1_vibe_fs_tra_p4_bh_arteriel 2 Prostate 11 t1_vibe_fs_tra_p4_bh_pre In the Series panel, select all the series you Multi parametric A Dynamic A Series want to use as dynamic data. Drag and drop them to the Dynamic image segment Series Name 7/24/2018 using the right mouse button. Select MR, Tumor_CE_BLADE_BO18ch_SP32ch Please drag data from Series Ne 16 11_vibe fs tra p4_bh delay Create Dynamic 4D. 15 t1_vibe_fs_tra_p4_bh_venos 14 t1_vibe_fs tra_p4_bh arteriel 3 11 t1_vibe_fs_tra_p4_bh_pre 8 t2_blade_fs_tra_p3_trigP MP 320 3 • If you are using a MR dedicated layout, 7 t2 blade_tra_p3 check that the data in the other image segments are the correct ones for a reliable propagation of the TC-ROIs. R Time Curve Graph Segmen Otherwise, drag and drop them. 3 Template Effective Date: 26 Mar 2025 | QR700020784 31 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Enhancements in MR Breast layouts Template Effective Date: 26 Mar 2025 | QR700020784 32 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Enhancements in MR Breast layouts (I) Viewing MR breast Dynamics Phase_02 Dynamics Phase_02 – Dynamics Phase_01 There is a new dedicated MR Breast layout in the MM Reading Workflow, under the Viewing I protocol MR Breast, the MR Breast Multiple MR Breast MR Breast MR Breast Dynamic Morphol ... Multipl .. R Time Points layout. Results 2x2 It displays the original dynamic series on the left column and the corresponding subtracted dynamic series on the right one. Dynamics Phase_03 Dynamics Phase_03 – Dynamics Phase_01 By default, the layout displays: R R • The Phase_02 of the dynamic acquisition with its corresponding subtraction. • The Phase_03 of the dynamic acquisition with its corresponding subtraction. Dynamics last phase Dynamics last phase – Dynamics Phase_01 • The last phase of the dynamic acquisition with its corresponding subtraction. R You can adapt the displayed series using drag & drop or the Data Assignment tool of the Layout Editor. Template Effective Date: 26 Mar 2025 | QR700020784 33 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Enhancements in MR Breast layouts (II) Dynamics Phase_03 Dynamics Phase_03 – Dynamics In the MR Breast layouts of the MM Reading Phase_01 Workflow, the synchronization of the phases between the original dynamic series and the dynamic subtraction series is now adapted. The phase of the original dynamic series (Phase_x) synchronizes with the corresponding phase of the subtracted series (Phase_x- Phase_1). For example, the Phase_03 of the original Dynamics Phase_03 – Dynamics dynamic acquisition now synchronizes with the Phase_01 subtraction Phase_03 - Phase_01. IR R Template Effective Date: 26 Mar 2025 | QR700020784 34 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Enhancements in MR General Tools Template Effective Date: 26 Mar 2025 | QR700020784 35 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Enhancements in MR General Tools (I) PREVIOUS SW VERSIONS VC10 The UI of the MR General Tools in the MR dedicated workflows, such as the MR Prostate Motion Correction ? X Motion Correction ? X Workflow, is now similar to the one in the MM 1 Reading Workflow. ettings MR Motion Correction Sett ... Config . Settings MR Motion Correction Sett ... Config. Input Volumes t1_f13d tra_caipi_dynamic.latest.Phase 01 t1_f13d_tra_caipi_dynamic.latest.Phase_03 Input Volumes t1_f13d_tra_dynaViews_spair_2-5.latest.Phase 01 In the MR dedicated workflows, the Preview t1_f13d_tra_caipi_dynamic.latest.Phase 04 t1_f13d_tra_dynaViews_spair_2-5.latest.Phase_03 t1_f13d_tra_caipi_dynamic.latest.Phase 05 t1_f13d_tra_dynaViews_spair_2-5.latest.Phase_04 t1_f13d_tra_caipi_dynamic.latest.Phase_06 t1_f13d_tra_dynaViews_spair_1.latest button and the Target Segment section have been removed from the MR General Tools: Reference Volume t1_f13d_tra_caipi_dynamic.latest.Phase_02 Remove Result Series Name MoCOHiQ_11_f13d_tra_caip Create Subtraction Datagroup ? Reference Volume t1_f13d_tr Create Subtraction Datagroup ? 1 • From the Correction Tools – Motion Target Segment Result Series Name MoCoHiQ_t1 2 Correction. ettings MR Subtraction Settings Config. Settings MR Subtraction Settings Config . Minuend t1_f3d_tra_caipi_dynamic.latest.Phase 02 Minuend t1_f13d_tra_dynaVIEWS_1+5.latest.Phase_02 t1_f13d_tra_caipi_dynamic.latest.Phase_03 t1_f13d_tra_dynaVIEWS_1+5.latest.Phase_04 t1_f13d_tra_caipi_dynamic.latest.Phase_04 t1_fi3d_tra_dynaVIEWS_1+5.latest.Phase_06 2 • From the Analysis Tools – Subtraction, t1_f13d_tra_caipi_dynamic.latest.Phase_05 OK Preview t1_f13d_tra_caipi_dynamic.latest.Phase_06 OK Addition, Multiplication, Division and Arithmetic Mean. Subtrahend 1_f13d_tra_caipi_dynamic.latest.Phase_01 Subtrahend t1_f13d_tra_dynaVIEWS_1+5. latest. Phase_01 Use Constant Use Constant Result Series Name Sub_P1_11_f1 3d_tra_caipi dynamic Target Segment Result Series Name Sub_P1_11_f1 3d_tra_dynaVIEWS_1+5 OK Preview Cancel OK Cancel Template Effective Date: 26 Mar 2025 | QR700020784 36 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Enhancements in MR General Tools (II) PREVIOUS SW VERSIONS VC10 The UI of the ADC & b-value tool in the MR -.-.-.-.-. .-.-.-.-.-.-.-.-.- dedicated workflows, such as the MR Prostate ADC & b-value X ADC & b-value X Workflow, is now similar to the one in the MM ADC Map Calculation Config. ADC Map Calculation Reading Workflow. Config. Input Series resolve_dwi_spair Input Series ADC & b-value Preprocessing ? X M ep2d ADC & b-value Preprocessing X B-Value_01_50 ¥ B-Val In the MR dedicated workflows: B-Value_02_400 2 ¥ B-Val B-Value 03 800 Enable Preprocessing B-Valu .Enable Preprocessing b-value 1400 b-value 1400 • The Target Segment section has been Scaling Threshold 1 Threshold 10 + Threshold 10 Scaling removed. Threshold Result Series Name ADC_b50_400_800_resolve Number of input b-values Number of input b-values Result Series Name ADC_b50_40 Computed b-value images 2 Computed b-value Cancel OK 2 OK Defaults Cancel • In the ADC & b-value Preprocessing, the Enable Computed b-value Enable Computed b-value b-value 1400 M Auto Preview Restore button has been replaced by b-value 1400 Auto Preview Scaling Defaults button. Result Series Name CALC_b1400_b50_400_800_resolve_dwi_spair_tra_ Scaling 1 Target Segment Result Series Name CALC_b1400_b50_400_800_ep2d_tra_3b_spair_REV 1 b-value ADC 3 • A dedicated ADC & b-value layout has MR Prestote ADC & B-veh been implemented. OK Preview Cancel ADC Map Cacusion 3 OK Details are explained on the next slide. puted b-value images Template Effective Date: 26 Mar 2025 | QR700020784 37 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Enhancements in MR General Tools (III) MR Prostate -.-.-.-.-.-.-.-.-.--.-.-.-.-.-.- Q + ADC & b-value 1 Computed b-value 2 This new layout has three segments: MR Prostate Reading -.-.-.-.-.-.-.-.-.-.-.-.-.-.-.- ADC Map Calculation Config. 1 • Diffusion data segment, which contains the Pingle Learn Segments Support Input Series M DIFF AX_TRACEW diffusion data. B-Value 01 50 Prostate Lesions B-Value 02 1000 B-Value 03 2000 RFP Prostate 2 • Computed b-value preview segment. Viewing It contains the computed b-value images loaded as preview. If Auto Preview is Threshold 10% Findings active, you can check the corresponding Prostate Result Series Name ADC_b50_1000_2000_DIFF AX_TRACEW Computed b-value images preview on the fly, while modifying the b- Enable Computed b-value ADC maps 3 value. b-value 1400 Auto Preview Scaling 1 3 • ADC maps preview segment, which Result Series Name CALC_b1400_b50_1000_2000_DIFF AX_TRACEW - ADC & b-value contains the ADC maps loaded as preview. X RFP Tools L OK Preview Cancel Synch Lock Full Text Hide Hide Lines Reset Navigati. Graphics Timepoi ... Edit Snapshot Print Export Unde Layout Image Image 4:26 PM Template Effective Date: 26 Mar 2025 | QR700020784 38 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Enhancements in MR Spectro Template Effective Date: 26 Mar 2025 | QR700020784 39 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Enhancements in MR Spectro Spectro Browser ? X Six new factory protocols are now available in the MR Spectro Workflow. Show V W Siemens V In vivo V ¿ Customer View Details Phantom Import Export Systems Protocols Metabolite Templates Model Signal Files These protocols are designed for MR 1.5 T spectroscopy acquisitions in 7.0 T systems using 1H Protocol System Nucleus Sequence Purpose TE [ms] 31P as the nucleus: 31P Wy liver csi 7.0 T 31P csi fid In vivo 0-10 ¥ 3.0 T w liver fid 7.0 T 31P fid in vivo 0-10 • liver_csi (in vivo) w muscle csi 7.0 T 31P csi fid In vivo 0-10 1H muscle fid 7.0 T 31P fid In vivo 0-10 • liver_fid (in vivo) 31P lu qa csi 7.0 T 31P csi fid Phantom 0-5 We ga fid 7.0 T 31₽ Tid Phantom 0-5 • muscle_csi (in vivo) 7.0 T 31F • muscle_fid (in vivo) • qa_csi (phantom) • qa_fid (phantom) Edit ... Delete Cancel Template Effective Date: 26 Mar 2025 | QR700020784 40 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Enhancements in MR Tissue4D Template Effective Date: 26 Mar 2025 | QR700020784 41 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MR SIEMENS Healthineers Enhancements in MR Tissue4D MR Tissue4D Properties ? X # Series Name In the Data Def. of the MR Tissue4D Properties, 9/6/2017 you can now define strings that contain: 2:00 PM Data Def. Preprocessing Alignment Processing Parametric Map MR, Prostate_Tumor_BLADE • The space character. ... 11 > DIFF AX_TRACEW • The asterisk character (*) at the end of the Morphology Pre-Contrast Dynamic Series Descriptions Series Descriptions Series Descriptions 12 DIFF AX ADC definition, which is considered as a t2_tra PreContrast t1_vibe wildcard symbol. t2_tse_tra 13 t2_blade_tra flip t1 twist dyn 14 t2_blade_CORO perf vibe 15 PERF vibe MASQUE 16 PERF vibe MASQUE_post + + + Add Remove PERF vibe Remove Restore Add Restore Add Remove Restore Lookup Table Lookup Table Lookup Table Hot Body Hot Body Hot Body Restore Restore Restore Data Streaming Settings waiting time from DICOM waiting time 0 ;econds waiting time OFF Template Effective Date: 26 Mar 2025 | QR700020784 42 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Please note that this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product-related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration-dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim, Germany Phone: +49 9191 180 siemens-healthineers.com Template Effective Date: 26 Mar 2025 | QR700020784 43 Job Aid Effective Date: 19 May 2025 | QR700023491 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025
- syngovia
- mr
- news
- whats new
- delta