
What’s New in MM syngo.via VC10
This job aid provides an overview of the latest updates and enhancements in syngo.via VC10 for Multimodality reading. It includes step-by-step instructions for using new tools and features to improve workflow efficiency.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet and smartphone)
SIEMENS Healthineers What’s New in MM syngo.via VC10 Template Effective Date: 26 Mar 2025 | QR700020784 1 This training material is based on the medical devices syngo.basic VB60J and syngo.MR Applications VC10A. Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Disclaimer SIEMENS Healthineers syngo.via Q Scanner AI-Rad Companion V syngo.via Syngo Carbon View&GO Space Please keep in mind that the user interface may differ slightly from what is shown in this Job Aid. The actual usage of the tool may differ slightly on the different host systems, for example on syngo.via, Syngo Carbon Space, syngo.via View&GO, AI-Rad Companion or on the scanner. The tool functionality defined in this Job Aid is applicable to any of the Siemens Healthineers products in which you find this tool. Template Effective Date: 26 Mar 2025 | QR700020784 2 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Table of Contents Introduction 4 Single Click tool 6 Automatic software update 8 Enhancements in Cinematic VRT 15 Enhancements in Spine Ranges 18 Enhancements in usability 20 Enhancements in Tool Gallery 23 . ... Enhancements in Layout Gallery 25 Enhancements in Layout Editor 27 Region specific measurements on US 53 Template Effective Date: 26 Mar 2025 | QR700020784 3 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Introduction Template Effective Date: 26 Mar 2025 | QR700020784 4 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Introduction Purpose The following educational content guides you 1, 2 through the most relevant updates from O C2 syngo.via VB80A to VC10A for the Multimodality C3 reading. A C4 C5 O [2] Distance Line o.p. C6 Some of the updates explained here may already 3.88 cm be available in certain VB80x software versions [1] Distance Line o.p. 6.71 cm Ti released after VB80A. T2 H 3 T4 Total Angles 180 00 Angle Between Images: 10.0. Par. Rad Cur Spil * Vas Preset Select the Preset Angle between Images 10.0 RP Number of Images 19 + Field of View 323.3 = x 323.3 - mm Presets Orientation Image Series Start Accept Close Template Effective Date: 26 Mar 2025 | QR700020784 5 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Single Click tool Template Effective Date: 26 Mar 2025 | QR700020784 6 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Single Click tool 2 Tool Gallery × The Single Click tool is now available in the Tool Gallery of MM Reading. Q Search Basic Interactions This feature allows you to load data into the Zoom/Pan Scroll Rotate Movie Home selected image segment with a single click on Position RA RA one of the series in the Series panel. This Reset Synch Synch Align Visual ayout Config Alignment eliminates the need for drag and drop: EF ? Undo Redo Next Study Previous Quick Study Guide 1 • Activate the Single Click tool. + 1 Magnifier Single Click 2 • Select the image segment in which you 3 want to load the data group(s). H H Series Add 3 • In the Series panel, click once on the data Study Series Name group(s) you want to visualize. The data 6/2/2015 group(s) then loads into the selected 11:59 AM MR, Comparison_SHS16ch ... 05b t1 tse cor 448 p2 image segment. RA RA 17 07b_t2_me3d_we_cor_p .. 04b_pa_tse_is_tra_320 08b_t2_tse_sag_320_p2 Single Click is user specific 03b_pd_tse_fs_cor_p2_384 1 This tool is not activated by default. Once 16 06b_t1_tse_tra_320_p2 12 02b_pd_tse_fs_cor 320 2 .. activated, it remains active for that user. 11 01b_pd_tse_cor_384_2m ... 10 05a_t1_tse_cor_448_p2 Template Effective Date: 26 Mar 2025 | QR700020784 7 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Automatic software update Template Effective Date: 26 Mar 2025 | QR700020784 8 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Activation of a software update There is a new automatic software update that allows the IT administrators to activate new Update News PX syngo.via software versions. syngo.via VB8OF is available for your system Reasons for Update / Upgrade This feature provides: Bug fixes, performance, stability, serviceability, security improvements and OTS updates. For further information, please click help icon (or press F1 key) • Full control and flexibility to keep your system up to date. Contact your IT Administrator IT Admin: Email: • The possibility to benefit from the latest improvements and security fixes. Phone: The system informs you about the availability of new software versions: Show Re syngo.via Update Status • In the syngo.via clients, via the Update News. Dear System Administrator, • Via email notifications to the users, including IT administrators, defined in the Your syngo.via system is ready for an update to the latest software version VB80F. dedicated section of the Administrator Portal. The virtual preparation has been successfully finalized in the background and you can schedule the update procedure. Your action: Please define the most suitable date and time for your update in the Administration Portal. syngo.via information: System Serial No: 999999 System Material No: 10496180 Interested in finding out what's new in syngo.via? Please login into the Administration portal online help and check the addendum Template Effective Date: 26 Mar 2025 | QR700020784 9 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Update News (I) The Update News are available to notify users about the availability of a new Update News ? X upgrade/update. This allows the administrator to schedule the downtime to activate the upgrade/update in the system. syngo.via VB8OF is available for your system Reasons for Update / Upgrade Bug fixes, performance, stability, serviceability, security improvements and OTS When a new version is ready for installation: updates. For further information, please click help icon (or press F1 key) Contact your IT Administrator • A fly in dialog, a notification dialog and a badge are shown after starting IT Admin: Email: syngo.via. These are visible: Phone: • To all users who log in a syngo.via client. Show Reminders When the update package is customer-activable. Update News • x Close • When the system is not part of a Multi-Server cluster. A new syngo.via version is available • When the pop-up notification is enabled in the System Update page. and ready for installation You can also open the Update News notification dialog from the menu ?. Help 5:16 PM • If no upgrade/update is available, the following default message is shown: Online Training Remote Assistance Welcome to Update News What's New syngo News Your server has currently installed the latest syngo.via version. Here you will find information about new version when it is available for installation. Update News About Template Effective Date: 26 Mar 2025 | QR700020784 10 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Update News (II) For further information on the new version that is ready for activation, press F1 Update News ? IX when the Update News fly in dialog is open, or the ? icon on top of the dialog. You will see the badge and the fly in dialog (if an update/upgrade is available) syngo.via VB8OF is available for your system regardless of whether or not you have read the Update News. Reasons for Update / Upgrade Bug fixes, performance, stability, serviceability, security improvements and OTS updates. To hide the badge and the fly in dialog displayed after starting syngo.via, uncheck For further information, please click help icon (or press F1 key) the options available under Show Reminders: Contact your IT Administrator IT Admin: • If Show notifications for this message is unchecked, the fly in dialog will Email: Phone: not be shown. • If Show notification badge for this message is unchecked, the badge will not be shown. Show Reminders Show notifications for this message Show notification badge for this message If the system has not been updated/upgraded during that week, the system will automatically create and send a new message at the end of the week. Therefore, Close after the weekend, the badge and the fly in dialog will pop-up again. The badge and the fly in dialog will no longer appear after you have installed the new version. Template Effective Date: 26 Mar 2025 | QR700020784 11 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Email notifications (I) NEW PACKAGE AVAILABLE ACTIVATION SCHEDULED STARTING THE ACTIVATION When the IT administrator can activate a new After the IT administrator schedules the update When the scheduled date and time is reached, software version, or can schedule its activation, in the Administrator Portal, the following email the activation process starts, and the following the following email notification is sent: notification is sent: email notification is sent: syngo.via Update Status syngo.via Update Status syngo.via Update Status Dear System Administrator, Dear System Administrator, Dear System Administrator, Your syngo.via system is ready for an update to the latest software version VB80F. The virtual preparation has been successfully finalized in the background and you Your syngo.via system is scheduled for an update to the latest version VB80F on Your scheduled syngo.via system update is starting now. can schedule the update procedure. 2025-04-01, 02:00 PM. The system is being updated to version VB80F. You can change the date and time in the Administration Portal. Your action: Please define the most suitable date and time for your update in the Your action: Please check the availability of your syngo.via system after 45 minutes. Administration Portal. Your action: Please inform all syngo.via users about the expected system downtime of 45 minutes on 2025-04-01, 02:00 PM. syngo.via information: syngo.via information: System Serial No: 999999 System Serial No: 999999 syngo.via information: System Material No: 10496180 System Material No: 10496180 System Serial No: 999999 System Material No: 10496180 Interested in finding out what's new in syngo.via? Please login into the Administration portal Interested in finding out what's new in syngo.via? Please login into the Administration portal online help and check the addendum online help and check the addendum Interested in finding out what's new in syngo.via? Please login into the Administration portal online help and check the addendum Template Effective Date: 26 Mar 2025 | QR700020784 12 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Email notifications (II) STARTING THE ACTIVATION ACTIVATION SUCCESSFUL ACTIVATION FAILED (during pre-restore) In case that the IT administrator activates the Once the activation is successfully completed, The IT administrator should raise a ticket. installation via the Install Now option in the the following email notification is sent: If the activation failed during pre-restore steps, Administrator Portal, the following email the system remains in the previous software notification is sent: version. Then the following email notification is sent: syngo.via Update Status syngo.via Update Status syngo.via Update Status Dear System Administrator, Dear System Administrator, Dear System Administrator, Your scheduled syngo.via system update is starting now. Your syngo.via system has been successfully updated to software version VB80F. Your syngo.via system update to version VB80F could not be started. The system is being updated to version VB80F. The updated system is now available for use. The system remains at version VB80E and is available for use. Your action: Please check the availability of your syngo.via system after 45 minutes. Your action: Please check the system status monitor in the Administration Portal for Your action: Please open an incident ticket and reschedule the update. any pending tasks. syngo.via information: syngo.via information: System Serial No: 999999 System Serial No: 999999 syngo.via information: System Material No: 10496180 System Material No: 10496180 System Serial No: 999999 System Material No: 10496180 Interested in finding out what's new in syngo.via? Please login into the Administration portal Interested in finding out what's new in syngo.via? Please login into the Administration portal online help and check the addendum online help and check the addendum Interested in finding out what's new in syngo.via? Please login into the Administration portal online help and check the addendum Template Effective Date: 26 Mar 2025 | QR700020784 13 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Email notifications (III) ACTIVATION FAILED (during restore) The IT administrator should raise a ticket. If the activation failed during the restore steps, the system is not usable. Then the following email notification is sent: syngo.via Update Status Dear System Administrator, Your syngo.via system update to version VB80F was not successful. Your action: Please open an incident ticket. syngo.via information: System Serial No: 999999 System Material No: 10496180 Interested in finding out what's new in syngo.via? Please login into the Administration portal online help and check the addendum Template Effective Date: 26 Mar 2025 | QR700020784 14 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Enhancements in Cinematic VRT Template Effective Date: 26 Mar 2025 | QR700020784 15 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Distance measurements in Cinematic VRT H Distance Line You can now measure distances in a Cinematic VRT view using either the Distance Line tool or Distance Line the Distance Polyline tool. Distance Polyline 1, 2 The measurements are on projection, indicated by o.p. in the measurement text. R [2] Distance Line o.p. 3.88 cm [1] Distance Line o.p. 6.71 cm Template Effective Date: 26 Mar 2025 | QR700020784 16 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Radial Ranges in Cinematic VRT A You can now create Radial Ranges from a Cinematic VRT view. 1, 2 The calculation occurs in the background, ensuring you are not blocked during the result R R A creation. Total Angle: 180 0% Offline Calculation confirmation Angle Between Images: 10.0 * The ranges generation can take several minutes. 1. Series will be generated in the background H. 2. Process will continue also after you close the workflow Par. Rad Cur E Spil * Vas Preview Range Series Name C VRT Range Preset Select the Preset Image Comment 2 Calculate Cancel Angle between Images 10.0 o Number of Images 19 RP The result appears in the Series panel once Field of View 323.3 X 323.3 mm ready. Presets Orientation Image Series # Series Name 1063 & CVRT Range Start Accept Close Template Effective Date: 26 Mar 2025 | QR700020784 17 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Enhancements in Spine Ranges Template Effective Date: 26 Mar 2025 | QR700020784 18 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Spine Ranges – Subset of spine ranges AFL The Spine Ranges tool now supports the generation of a subset of ranges. 1, 2 1, 2 1, 2 C2 O You can select a subset by grabbing and moving C3 O the top and/or bottom line in the planning image C4 C3 R O RF A C5 C4 C6 C5 O segment. C7 C6 O O C7 TI O C4/C5 T2 T3 T4 AFL Paral Radia Curv Spine * Vasci Preview 2 Image Thickness; 0.7 mm Distance between Images: 2.0 mm Number of Images 44 + RF Field of View. 47.0 X 58.7 mm Presets Image Series Curved Curved ParaCor ParaSag Start Accept Close Template Effective Date: 26 Mar 2025 | QR700020784 19 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Enhancements in usability Template Effective Date: 26 Mar 2025 | QR700020784 20 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Viewing panel – Improved usability (I) Viewing 1 Viewing CE 2 The usability of the Viewing panel has been improved with an automatic collapsing function. › Viewing > Viewing Layout Editor • X Layout Editor 1 Inactive complex tools, including the dedicated Viewing section, are now - TimeCurve × collapsed. New Change Resize Merge O layout Geometry Segments 2 • When you click on a collapsed dedicated TC-Circle TC-Pixel TC- Lens Freehand Snapshot tool panel, the tool is activated and the Split Data Visualiza ... Synch tool panel expanded. The other tool Segment .. Assignm ... Editor Config panels, including the dedicated Viewing Basic Breast section, then collapse. Save layout Composer › TimeCurve › Composer Template Effective Date: 26 Mar 2025 | QR700020784 21 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Viewing panel – Improved usability (II) Viewing C The usability of the Viewing panel has been Viewing improved with a separate color area for the Workflow Controls. - Composer × This improved usability helps you avoid misusing v New New Confirm the controls, especially when a complex tool is Compose Combine Result open in the panel above. Results T1_COMP auto Blend/Cut Normalize Manual Mode Adjust Workflow Controls • Save and Send • Save and Pause Template Effective Date: 26 Mar 2025 | QR700020784 22 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Enhancements in Tool Gallery Template Effective Date: 26 Mar 2025 | QR700020784 23 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Tool Gallery – Searching tool Tool Gallery X Tool Gallery 1 The Tool Gallery now includes a new Search field, allowing you to search for the desired tool. Q Search Q vie X When you start typing a substring of the tool Basic Interactions Basic Interactions label in the Search field, the Tool Gallery filters Zoom/Pan Movie and displays only matching results, including Scroll Rotate Movie Home Reset Position Layout tools or categories with the matching substring in 3D Editing Tool Gallery their label. 2 Synch Synch Redo Config Align Visual Undo Alignment Auto + Views rang X For example: Next Study Previous Quick Magnifier Single Study guide Click Print & Export Ranges 1 • Entering the substring vie suggests tools Display Types like Movie, Auto Views, and Export Image Export Radial Curved Spine Radial Edit Result Call Image Parallel Ranges Slice ... Ranges Ranges Ranges because Record Movie belongs to that Export Image * group. Export Stack Vascular Ranges Copy Image 2 • Entering the substring rang suggests all Copy Layout tools under the category Ranges. Record Movie JPG Export non-DICOM Template Effective Date: 26 Mar 2025 | QR700020784 24 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Enhancements in Layout Gallery Template Effective Date: 26 Mar 2025 | QR700020784 25 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Layout Gallery – Searching tool Layout Gallery X Layout Gallery 1 The Layout Gallery now includes a new Search field, allowing you to search for the desired Q Search Q bre X layout. Layout operations Public Layouts When you start typing a substring of the layout label in the search field, the Layout Gallery filters Save Save Layout MR Breast MR Breast MR Breast layout layout as Editor Dynamic Morphol ... Multipl ... and displays only matching results, including layouts or categories with the matching substring Private Layouts Siemens Layouts Layout Gallery 2 in their label. BOLD_1 ... BOLD_2 ... X 4x3 MR Breast MR Breast MR Breast Q 4 Dynamic Morphol ... Multipl ... For example: Public Layouts Private Layouts 1 • Entering the substring bre suggests 4×3 Stack 1x1 Stack 2x1 Stack 2x2 Stack 3x2 Stack 3x3 Stack 4x4 layouts like MR Breast Dynamic, MR Breast Morphology, and MR Breast Public Layouts Multiple Time Points. Stack 4x4 Follow Up 4TP 2 • Entering the substring 4 suggests layouts Siemens Layouts like 4x3, from the Private Layouts collection, Stack 4x4, and Follow Up 4TP. Stack 4x4 Follow Up 4TP Template Effective Date: 26 Mar 2025 | QR700020784 26 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Enhancements in Layout Editor Template Effective Date: 26 Mar 2025 | QR700020784 27 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers New layout tool Viewing This tool creates a new 2x2 empty layout. The › Viewing behavior is almost like using the Change Layout Editor X Geometry tool, selecting a 2x2 layout. New Change Resize Merge Split When you use Change Geometry, you continue layout Geometry Segments Segme Please drag data from Series Navigator. Please drag data from Series Navigator. editing the current layout. Data Visualiza. Synch Save • You can save it using either Save layout or Assignm ... Editor Config layout Save layout as. However, after using New layout: • You can only save the new layout with Save layout as. Once you name the new layout, you can use Save layout too. Please drag data from Series Navigator. Please drag data from Series Navigator. Useful for … This is a better option for creating new layout to avoid unintended overwrite of an existing one. Template Effective Date: 26 Mar 2025 | QR700020784 28 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Selecting all segments using Ctrl + A Viewing ¢ × H HA Within the Layout Editor, you can now select all › Viewing segments of the layout using Ctrl + A. Layout Editor X New Change Resize Merge Spuit layout Geometry Segments Segme .. R R Ex Data Visualiza. Synch Save Assignm .... Editor Config layout ................................................................................................... H H R R Useful for … Configuring the synchronization of the image segments using the Synch Config tool. Template Effective Date: 26 Mar 2025 | QR700020784 29 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Copy & Paste in Data Assignment tool Viewing 1 Definition 1 X Definition 2 ............................... X Es|je ..... 2. Definition 1 X + EE You can now copy the Data Assignment settings Viewing Base Series 1 Base Series 2 from one image segment and paste them into Layout Editor X another one. In the Data Assignment tool: Timepoint Current Timepoint Timepoint New Change Resize Merge Split layout Geometry Segments Segme. Modality MR Modality Modality .............. Series Descri ... contains t1 Series Descri ... contains 1 • Define the desired settings in one of the Data Visualiza. Synch Save Assignm .. Editor Config layout contains mprage + image segments (source segment) and Add Series name Remove Series name Visual Expert click on Copy. + Add Series name Remove Series name Visual Expert Overlay Series • In the target segment, in which you would .... >> Create Overlay Series 2 Overlay Series like to have the same settings, click Timepoint Current Segments Grouping € Create Group on Paste. Modality MR Series Descri ... contains Remarks: + Series Name contains b-value_03 • It copies and pastes all Definitions of an image segment, regardless of whether you Add Series name Remove Series name Visual Expert use the Visual or Expert mode. ..................... Remove Overlay Series • It copies and pastes both the Base Series and the Overlay Series definitions. II Segments Grouping 4 Create Group • It does not copy and paste the Segment Grouping settings. Template Effective Date: 26 Mar 2025 | QR700020784 30 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Copy & Paste in Visualization Editor tool Viewing 2 You can now copy the Visualization Editor > Viewing settings from one image segment and paste Layout Editor X : Filter MIP 1 Filter 2D 2 them into another one. In the Visualization Orientation Original Orientation Original New Change Resize Merge Split Editor tool: layout Geometry Segments Segme .. Use Data Both ( Base ( Overlay Use Data O Both O Base ( Overlay 2D Stripe Enable 2D Stripe O Enable Data Visualiza. Assignm. Save ............ ............ Editor onng layout Reference Line Select Reference Line Select 1 • Define the desired settings in one of the image segments (source segment) and click on Copy. 2 • In the target segment, in which you would like to have the same settings, click on Paste. Remarks: • It copies and pastes the Filter, Orientation and User Data settings. • It copies and pastes the 2D Stripe mode. • It does not copy and paste the Reference Line settings. Template Effective Date: 26 Mar 2025 | QR700020784 31 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Collapsible sections in Data Assignment Viewing C . × Definition 1 X Definition 2 X The Data Assignment tool interface now features Viewing collapse/expand sections. Layout Editor X Base Series Timepoint Current New Change To gain space when configuring an image layout Geometry Resize Segments Modality MR Series Descri ... contains t1 segment, you can collapse or expand the three Data Visualiza. Synch Save Assignm ... Editor Config layou contains mprage main sections: Base Series, Overlay Series, and 1 Definition 1 X Definition 2 X Segments Grouping. Add Series name Remove Series name + Visual Expert Base Series Overlay Series Overlay Series Timepoint Current Segments Grouping 4 Modality MR Series Descri ... contains Series Name contains b-value_03 + Add Series name Remove Series name Visual Expert Remove Overlay Series Useful for … Whenever you need to get more space Segments Grouping 4 for information or edition, collapse the sections you do not currently need. Template Effective Date: 26 Mar 2025 | QR700020784 32 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Data Assignment – contains either of VC10 You can now use more than two strings within ------ one contains either of operator. Viewing Definition 1 X > Viewing Layout Editor X Base Series When you define two consecutive contains Timepoint Current either of operators, they are now combined with New Change Merge Split layout Geometry Resize Segments Segme ... Modality MR Series Description contains either of space an AND operator. Data Visualiza ... Synch Save Assignm ... Editor Config layout spc AND ....... mprage + Please note: After the update/upgrade, layouts ....... contains either of sag created previously with consecutive contains tra + either of operators will automatically use the + Add Series name Remove Series name new representation without any change in the layout’s behavior. PREVIOUS SW VERSIONS Viewing X Definition 1 X + B contains either of in previous software MR general Base Series versions Current Stack 2x2 MPR MIP Results Timepoint In previous software versions you could 2×2 Modality MR define a maximum of 2 strings withing Series Description contains either of space one contains either of. As workaround, H. OR spc ....... you had to use two consecutive contains Layout Editor X contains either of mprage either of operators, which were Resize Merge Split Change Data Segments Segme ... Geometr Assign + combined with and OR. Save Visual Expert Visualiz Synch Editor Config layout Template Effective Date: 26 Mar 2025 | QR700020784 33 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Data Assignment – Series Name (I) Viewing X 1 Definition 1 X You can use the Series Name in the Visual mode > Viewing of the Data Assignment tool as an additional Layout Editor X Base Series Current + Timepoint condition to define the content of an image New Change Merge Split layout Geometry Segments Segme ... Modality MR segment. This new condition is available for Series Description contains Assignm ... Visualiza Editor Config + both, the Base Series and the Overlay Series. 1 Add Series name emove Series name Visual Expert 1 • Click Add Series name. 1 Definition 1 X Definition 1 X Base Series Base Series 2 Timepoint Current • The additional field Series Name becomes Timepoint Current Modality MR Modality MR available for edition. Series Description contains Series Description contains + Series Name contains 2 Series Name contains 3 • Use any of the available operatorsto + + Add Series name Remove Series name starts with 3 Add Series name Remove Series name define the content. Visual Exper Visual Expert contains not contains Definition 1 X + 3 6 Overlay Series contains either of Create Overlay Series 4 • Enter the corresponding string based on: Base Series Segments Groupil ends with Create Group • The Series Name, that you can read Timepoint Current in the Series panel, or the data role. Modality MR # Series Name Series Description contains 1/24/2016 10:52 AM MR, Metal WARP_DRS_SMS HN12ch • The corresponding suggestion given 12 t2_tse_parasag_DRS_left + Series Name contains t1 4 11 t2_tse_parasag_DRS_right by the application when you e.g., t1_tse_sag_s2av_WARP 4 t2_tse_stir_cor_s2_DRS start typing a string. t2_tse tra DRS WARP Visual Expert t1_tse_sag_s2av_WARP.latest 6 t1_tse_sag_s2av_WARP t2_tse_sag_p2_s2av_DRS_WARP Template Effective Date: 26 Mar 2025 | QR700020784 34 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Data Assignment – Series Name (II) Base Series 1 Series Name with a data role The suggestions listed in Series Name can be: Timepoint Current Modality ANY When you use a data role (or part of its 1 • Series names, i.e., the names assigned to Series Description contains string) to define the Series Name, the data groups during the data mapping. Series Name contains t1 X Modality and Timepoint should be set to You can check them in the Series panel. t1_tse_sag_s2av_WARP ANY and Any timepoint respectively. The These suggestions are filtered based on: Visual Expert t1_tse_sag_s2av_WARP.latest application automatically performs this • change when you select the data role The Timepoint you select. Overlay Series Create Overlay Series from the list suggested in Series Name. • The Modality you select. Segments Grouping 4 Create Group • The string you type in Series Name. Base Series i Timepoint Current Base Series • 2 Data roles, i.e., the functional roles Modality Modality 2 Timepoint Current Series Description contains assigned to the data groups during the Modality ANY data mapping. These suggestions are Series Description contains Series Name contains filtered based on the string you type in Series Name Root.Current.SR contains MR X Visual Expert Series Name. Root.MR Root.Current.3D Visual Expert Root.MR.3D Root.CT Overlay Series Root.MR.3D_sag Root.CT.BasicRoutine Overlay Series Root. MR.3D_tra Segments Grouping 4 Root.CT.BasicRoutine.StudyO No series names are suggested Root.MR.3D_cor Root.CT.BasicRoutine.StudyO.Volume0 Segments Grouping 6 If you leave Modality empty, the Root.CT.BasicRoutine.StudyO.Volume1 suggestions are only data roles. H. Root.CT.BasicRoutine.StudyO.Volume2 Root.CT.BasicRoutine.StudyO.Volume3 Template Effective Date: 26 Mar 2025 | QR700020784 35 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Data Assignment – Series Name (III) Definition 1 X 1 • To stop using the Series Name as a Base Series condition, click Remove Series name. Definition 1 X Timepoint Current Base Series Modality MR 2 • Please note: If you use Series Name in Series Description contains Timepoint Current Modality combination with Series Description to MR + Series Name contains t1 Series Description contains 1 define the content of the image segment, + Remove Series name both must be true. Add Series nam Add Series name Remove Series name Visual Expert Visual Expert That is, Series Description and Series Name conditions are combined with an Definition 1 X AND operator. This is consistent with the 2 Base Series AND operator used to combine the other conditions, Timepoint and Modality. AND Timepoint Current Modality MR AND Series Description contains tse contains t1 AND + Series Name not contains _post contains water + Add Series name Remove Series name Visual Expert Template Effective Date: 26 Mar 2025 | QR700020784 36 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Data Assignment – Series Name (IV) Let’s review one example of use case: Precontrast 1 1 • You run a pre- (series #15) and a post- (series #22) contrast scan. 2 • Both scans have the same protocol name, therefore the Series Description is the Patient Browser – Series Description Series panel – Series Name same for both scans. This is what you can 10cm clearly see in the Patient Browser. Series # Series Name 2 3 Series Number Series Description 6/26/2019 5 t2_tse_sag_448_3mm MR, Stroke_Angio_CE_HN20ch 3 • The data mapping identifies that those 6 ep2d_diff_3scan trace tra 4mm TRACEW 103 transversal_mpr 7 ep2d_diff_3scan_trace_tra_4mm_ADC 103 transversal_projection image scans are the same. However, the series Postcontrast 8 t2 tse dark-fluid tra 4mm 102 coronal_mpr 9 t2 fl2d tra hemo #22 was scanned after contrast injection, 15 t1_se_17rb130 tra 102 coronal_projection image 16 angio_fl3d_cor_nativ TTC=1.0s 23 t1_mprage_sag_we creating a Series Name using the Series 17 test bolus tra 101 3 D.Reco Halsgefäße [TTC=1.0] 18 angio_fl3d_cor_p3_KM_TTC=1.0s Description and the suffix _post for #22. 3 D Reco_csa mip [TTC=1.0] 19 angio_f13d_cor_p3_KM TTC=1.0s MOCO-STD 100 100 3 D Reco_csa mpr [TTC=1.0] That is the Series Name you read in the 20 angio_fl3d_cor_p3_KM TTC=1.0s MOCO-STD SUB 21 angio fl3d cor p3 KM MOCO-STD SUB MIP COR 22 t1_se_17rb130_tra_post Series panel. RPF 22 t1_se_17rb130 tra 21 angio_fl3d_cor_p3_KM_MOCO-STD_SUB MIP_COR [TTC=1.0] 100 3 D Reco 20 angio_fl3d_cor_p3_KM_MOCO-STD_SUB [TTC=1.0] 101 3 D.Reco Halsgefäße 23 t1_mprage_sag_we 19 angio_fl3d_cor_p3_KM_MOCO-STD [TTC=1.0] 0cm 102 coronal 18 angio_fl3d_cor_p3_KM [TTC=1.0] 103 transversal 17 test_bolus_tra 16 angio_f13d_cor_nativ [TTC=1.0] F 15 t1_se_17rb130_tra 19 t2_f12d_tra_hemo Template Effective Date: 26 Mar 2025 | QR700020784 37 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Data Assignment – Series Name (V) Definition 1 X + B TE 2 Definition 1 X 4 • While the Series Description cannot distinguish Series #15 and Series #22, you Base Series Base Series can now use the Series Name in the Timepoint Current Timepoint Current Visual mode of the Data Assignment tool Modality MR Modality MR to differentiate these scans and define the Series Descript ... contains Series Descript ... contains content of the image segments. + + Series Name contains 1_se Series Name contains t1_se not cont ... post 4 contains post Add Series name Remove Series name + Add Series name Remove Series name + Visual Expert Visual Expert -----.-.-.- Precontrast Postcontrast Useful for … You can distinguish series that have the same Series Description if the data mapping provided different Series Name. F Template Effective Date: 26 Mar 2025 | QR700020784 38 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Data Assignment – Series Name (VI) 1 Another use case is the definition of one b-value b-value = 0 data group of a MR diffusion scan. 1 • Run a diffusion protocol with two different b-values. 2 • The Patient Browser shows only one series for both b-values, which is series #8. The Series Description for both b- values is the same. 3 • b-value = 1000 The data mapping identifies two different Patient Browser – Series Description Series panel – Series Name b-values, creating two distinct data groups for the series #8. This differentiation is Series 2 Series Name 3 reflected in the Series Name you see in Series Number Series Description 12 Pha_Images the Series panel. 11 Mag_Images 6 t2_tse_dark-fluid_tra t2_2d_cor_#6 10 Diffusion_Resolve_SMS_BT#12_EXP 7 Diffusion Resolve_SMS_BT#12_TRACEW 9 Diffusion Resolve_SMS_BT#12_ADC CO 9 Diffusion_Resolve_SMS_BT#12_ADC 8 Diffusion_Resolve_SMS_BT#12_TRACEW 10 Diffusion_Resolve_SMS_BT#12_EXP B-Value_01 [bo] 11 Mag_Images B-Value_02 [b1000] 12 Pha_Images 7 t2_2d_cor_#6 6 t2_tse_dark-fluid_tra Template Effective Date: 26 Mar 2025 | QR700020784 39 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Data Assignment – Series Name (VII) 1 Definition 1 X 4 • While the Series Description cannot b-value = 1000 distinguish the different two b-values, you Base Series v can now use the Series Name in the Timepoint Current Visual mode of the Data Assignment tool Modality MR to differentiate those and define the Series Description content of the image segments. contains diff + Series Name contains b-value_02 + Add Series name Remove Series name Visual Expert 4 2 Definition 1 X b-value = 0 Base Series A Timepoint Current Modality MR Series Description contains diff Useful for … + You can define a specific b-value of a MR Series Name contains b-value_01 diffusion scan. + Add Series name Remove Series name Visual Expert Template Effective Date: 26 Mar 2025 | QR700020784 40 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Data Assignment – Segments Grouping UI (I) Viewing Definition 1 X + EB TE 2 Definition 1 X The interface for Segments Grouping is now Viewing more intuitive. Layout Editor X Timepoint Current Base Series Modality MR Timepoint Timepoint New Change Resize Merge Split layout Geometry Series Descri ... contains mprage Modality Modality To group multiple image segments, follow these Segments Segme .. + Series Descri ... contains steps: Data Visualiza .... Synch Save Add Series name Remove Series name Assignm ... Editor Config Visual Expert + Add Series name Remove Series name Visual Expert 1 • Click Create Group. Overlay Series Create Overlay Series Overlay Series Create Overlay Series Segments Grouping 4 1 2 • Choose the Group Type. Create Group 3 Definition 1 X 4 Definition 1 X 3 • Click the Select label in the Grouped Definition 1 X + EB Te Base Series Segments section. Base Series Select Segments 4 Overlay Series Select the Segments that will be added to this group. 4 • A floating Select Segments dialog opens. Create Overlay Series Monitor #1 ve Series name + Group Type Segments Grouping 4 2 Shared Data Source corresponds to Group Type 2 Shared Data Source Composite Data Set group as Same Data in previous versions. les V II Grouped Segments 3 Composite Data Set corresponds to Select H. group as Overview/Composite in Remove Group previous versions. Cancel Apply Template Effective Date: 26 Mar 2025 | QR700020784 41 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Data Assignment – Segments Grouping UI (II) Select Segments Definition 1 X 5 • Select the image segments you want to Select the Segments that will be added to this group. group with a single left mouse click. Base Series Monitor #1 Overlay Series Create Overlay Series 6 • Click Apply. 2 5 Segments Grouping 4 7 • The field Grouped Segments updates with 3 Group Type 7 Shared Data Source Composite Data Set your selection. Grouped Segments 2 X 3X elect Canc 6 Apply 9 8 • To remove an image segment from the Remove Group group, click the cross (X) next to the image segment number, or select Remove from Definition 1 X 2 group in that segment. Base Series 9 • To remove the complete group, click Overlay Series Create Overlay Series Remove Group. Segments Grouping 4 This segment is part of a group with Segment 1 8 Remove from group Group Type Shared Data Source Composite Data Set Grouped Segments 3 X Select 8 Remove Group Template Effective Date: 26 Mar 2025 | QR700020784 42 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Drag and dop into grouped segments (I) 1 Definition 1 X 2 3 The usability of the grouped segments has been Base Series improved. Overlay Se ... Create Overlay Series HR HL After grouping some segments as either Shared Segments Grouping @ Data Source or Composite Data Set using the This seg Data Assignment tool of the Layout Editor: Group Type Shared Dat ... Composite ... A A A E Grouped Se ... 2 X 3 X Select • Close the Data Assignment tool. Remove Group Overview Group • With the Layout Editor opened, drag and drop images to one of the segments that belongs to Definition 1 X 2 3 one of the defined groups. Base Series • All the segments of that group are Overlay Se ... Create Overlay Series H highlighted. Segments Grouping 4 This se • A tooltip informs the user about which Group Group Type Shared Dat ... Composite ... Type has been defined for the grouped Grouped Se ... 2 X 3 X Select segments. Remove Group Shared Data Group Template Effective Date: 26 Mar 2025 | QR700020784 43 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Drag and drop into grouped segments (II) 1 Definition 1 X 2 3 Notice that highlighting segments of the same Base Series group and providing the tooltip information about the group type is only available when Overlay Se ... Create Overlay Series HR HL dragging and dropping images to the segments Segments Grouping @ inside the Layout Editor. This seg Group Type Shared Dat ... Composite ... A A A E Also note that after dropping into the Overview Grouped Se ... 2 X 3 X Select group, i.e., Composite Data Set group, the whole Remove Group group content is replaced. Overview Group Definition 1 X 2 3 Base Series Overlay Se ... Create Overlay Series H Segments Grouping 4 This se Group Type Shared Dat ... Composite ... Grouped Se ... 2 X 3 X Select Remove Group Shared Data Group Template Effective Date: 26 Mar 2025 | QR700020784 44 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Visualization Editor – 2D Stripe Viewing 2 3 You can configure image segments to display - Viewing Layout Editor X Filter 2D Filter drag data from Series Navigce drag data from Series Navigse drag data from Series Navig data groups as 2D Stripe. In the Visualization Orientation Original Oriental Editor tool of the Layout Editor: New Change Resize Merge Split layout Geometry Segments Segme ... Use Data Both O Base ( Overlay Use Dat 1 EN 2D Stripe Enable Row Visualiza. 3 X Column Synch Save 3 2 1 Data • Enable 2D Stripe. Assignm Editor Config ayout Je drag data from Series Navigse drag data from Series Navigse drag data from Series Navig Reference Line 2 • Select the number of Rows and Columns, either numerically or graphically. e drag data from Series Navigse drag data from Series Navigse drag data from Series Navig 3 • After deactivating the Visualization Editor tool, the selected image segment displays AH AH AH HR as stripe 2D with its corresponding R R scrollbar. AH Please note: 2D Stripe forces a 2D Display Type. AH AH If any other Filter was previously selected, it R R A changes automatically to 2D. AH AH AH Useful for … R R R The display of single frames. Template Effective Date: 26 Mar 2025 | QR700020784 45 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Visualization Editor – Fusion info message Viewing Definition 1 X When you define an Overlay Series in the Data Viewing Assignment tool of the Layout Editor, a new Layout Editor X Base Series information message is displayed in the Timepoint Current New Change Resize Merge Split layout Geometry Segments Segme. Modality Visualization Editor: MR Series Desc ... cont ... mprage Data Visualiza. Synch Save Assignm. Editor Config layou cont ... km Data assignment configured for fusion filter. Add Series name Remove Series name Visual Expert This message reminds you to set the correct Display Type, defined in Filter, to be able to Overlay Series visualize the configured data as fused data if Timepoint Current Modality MR desired. Series Desc ... contains b-value_02 + × Add Series name Remove Series name Visual Expert Viewing Viewing Layout Editor Filter 2D X Data assignment configured for fusion filter New Change Resize Merge Split Original Useful for … layout Orientation Geometry Segments Segme ... Use Data O Both O Base ( Overlay It reminds you to set the correct settings Data isualiza .. Assignm ... Synch Editor Config ayout 2D Stripe O Enable in the Visualization Editor. Reference Line Select Template Effective Date: 26 Mar 2025 | QR700020784 46 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Visualization Editor – Reference Line (I) Viewing 1 Definition 1 2 Definition 1 X 3 Definition 1 X The new option Reference Line in the Viewing Segments Grouping 0 Layout Editor Base Series X Base Series Visualization Editor tool helps you to create Group Type Shared Data S ... Composite Da ... Timepoint Timepoint Timepoint Timepoint New Change Merge Split layout Geometry Segments Segme ... Modality Modality Modality Modality layouts with reference lines. Grouped Seg ... Select Series De ... con ... Series De ... con ... Data Assignm .. 1 Remove Group Select Segments + Select the Segments that will be added to this group. Add Series name Remove Series name Visual Expert Definition 1 X + BE To create a layout with image segments Monitor #1 Base Series Overlay Series Create Overlay Series containing reference lines, follow the next steps: Overlay Series Create Overlay Series 4 Segments Groupi ... Create Group 5 Segments Groupi ... Create Group • In the Data Assignment tool: Cancel Apply Definition 1 + B Definition 1 2 Definition 1 + G Definition 1 + B & • Create a Shared Data source group with all Base Series segments Grouping @ 1 Base Series Base Series Overlay Series Create Overlay Series Shared Data S ... Timepoint Timepoint Timepoint Timepoint the segments in which you want to V Group Type Composite Da ... Modality Modality Modality Modality visualize the reference lines. Segments Groupi .. Create Group Grouped Seg ... Select Series De ... con ... Series De ... con ... Remove Group Add Series name Remove Series name Add Series name Remove Series name Visual Expert Visual Expert In this example, the Shared Data source group Overlay Series Create Overlay Series Overlay Series Create Overlay Series consists of image segments number 1, 4 and This segment is part of a group with Segment 1 Segments Groupi ... Create Group Segments Groupi ... Create Group 5. These segments will display reference lines. Remove from group 5 Useful for … This segment is part of a group with Segment 1 Creating 3D layouts with reference lines. Remove from group Template Effective Date: 26 Mar 2025 | QR700020784 47 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Visualization Editor – Reference Line (II) Viewing C . X 1 • In the Visualization Editor tool: Viewing Layout Editor 2 Filter MPR Orientation CVRT + LU 2 • Select a Filter MPR, MPR THICK, New Change Resize Merge Split layout Geometry Segments Segme ... Use Data MinIP THIN MPR/MPR, MIP THIN, MinIP THIN or VRT 2D Stripe Data Visualiza. Assignm .. Editor Longa Save MIP THIN to define the Display Type. You must Reference Line MIP THIN define one of those Filter options in all MPR MPR THICK image segments where you want to display Filter MPR/MPR 3 the reference lines. Orientation Use Data VRT Filter MPR Filter 2D Filter 2D 2D Stripe VRT THIN Orientation Original Orientation Origina Orientation Original In this example, the Filter is set as MPR in the Use Data VRT/MIP Both ( Base ( Overlay Use Data Both ( Base ( Overlay Use Data Both ( Base ( Overlay Reference Line 2D Stripe Enable 2D Stripe Enable 2D Stripe Enable image segments number 1, 4 and 5. These Reference Line Select Reference Line Select Reference Line Select segments will display reference lines. Filter MPR Orientation Original Use Data Both O Base O Overlay 2D Stripe Enable Reference Line Select 5 Filter MPR Orientation Original Use Data Both O Base O Overlay 2D Stripe Enable Reference Line Select Template Effective Date: 26 Mar 2025 | QR700020784 48 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Visualization Editor – Reference Line (III) Viewing 2 3 3 • Click the Select label on the right of the Viewing Reference Line field. Layout Editor Filter MPR Filter 2D Filter 2D X Orientation Original Orientation Original Orientation Original + New Change Resize Merge Split layout Geometry Segments Segme ... Use Data Both O Base ( Overlay Use Data O Both O Base O Overlay Use Data O Both O Base O Overlay 4 • Select the segments in which you want to 2D Stripe Enable 2D Stripe O Enable 2D Stripe Enable Data Visualiza. Save visualize the reference lines and click Assignm .. Editor Contia eyou Reference Line 3 Select Reference Line Select Reference Line Select Apply. Select Segments 4 Select the Segments that will be added to this group. Filter MPR Monitor #1 5 • If you have not defined perpendicular Orientation Original orientations in all segments where you Use Data O Both O Base ( Overlay 4 2 want to display the reference lines, an 3 2D Stripe Enable Not in Shared Data Not in Shared Data group group information message informs you: Reference Line 5 If ‘Lock Reference Lines’ option is enabled, 5 images will be rotated so that reference Filter MPR Cancel Apply lines segments are strictly orthogonal. Orientation Original Filter MPR Showing reference lines Orientation Original Use Data Both ( Base ( Overlay To show the reference lines in one 2D Stripe Enable group, you must select two or three H. Reference Line 1 X 4 X 5 X 5 Select image segments of that group. If 'Lock Reference Lines' option is enabled, images will be rotated so that reference lines segments are strictly orthogonal. Template Effective Date: 26 Mar 2025 | QR700020784 49 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Visualization Editor – Reference Line (IV) Windowing • 6 HLA 7 6 If Lock Reference Lines is enabled and you Zoom/Pan have not defined perpendicular Filter MPR Rotate orientations in all segments where you Orientation Original Scroll Use Data AR want to display the reference lines: 30 Reference Point O Both O Base ( Overlay 2D Stripe Enable Lock Reference Lines 6 Reference Line 1 X 4 X 5 X 7 • The orientations of the grouped Select 1 If 'Lock Reference Lines' option is enabled, imaq ... segments are set automatically so that 4 LAF they are all perpendicular to each other. Filter MPR Orientation Original Use Data O Both O Base ( Overlay AR 2D Stripe O Enable Reference Line 1 X 4 X 5 X Select If 'Lock Reference Lines' option is enabled, imag ... Orientation 5 HLA It is recommended to define specific Filter MPR perpendicular orientations in each of the Orientation Original grouped segments even if Lock Use Data O Both O Base ( Overlay LAF H. Reference Lines is enabled. Then you 2D Stripe O Enable can forecast the exact view displayed in Reference Line 1 X 4 X 5 X Select each image segment. If 'Lock Reference Lines' option is enabled, imaq ... Template Effective Date: 26 Mar 2025 | QR700020784 50 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Visualization Editor – Reference Line (V) Windowing HLA 8 • 8 9 If Lock Reference Lines is enabled and you Zoom/Pan have defined the specific perpendicular Filter MPR Rotate Orientation in all segments where you Orientation L(left-right) Scroll A want to display the reference lines: 30 Reference Point Use Data O Both O Base ( Overlay 2D Stripe Enable Lock Reference Lines 8 5 X 9 • The orientations of the grouped Reference Line 1 X 4 X Select segments are according to your 4 selection. Filter MPR Orientation A(anterior-posterior) Use Data O Both Base O Overlay 2D Stripe O Enable Reference Line 1 X 4 X 5 X Select A Orientation 5 It is recommended to define specific Filter MPR perpendicular orientations in each of the Orientation F(feet-head) grouped segments even if Lock Use Data O Both O Base ( Overlay R H. Reference Lines is enabled. Then you 2D Stripe O Enable can forecast the exact view displayed in Reference Line 1 X 4 X 5 X Select each image segment. Template Effective Date: 26 Mar 2025 | QR700020784 51 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Visualization Editor – Reference Line (VI) Windowing 11 11 10 • If Lock Reference Lines is disabled: Zoom/Pan Filter MPR Rotate 11 • Define perpendicular orientations in all Orientation L(left-right) Scroll Use Data O Both O A segments where you want to display the 3D Reference Point Base ( Overlay 2D Stripe Enable reference lines. Lock Reference Lines 10 Reference Line 1 X 4 X 5 X Select 4 Filter MPR Orientation A(anterior-posterior) Use Data O Both Base O Overlay 2D Stripe O Enable Reference Line 1 X 4 X 5 X Select Orientation 5 A It is recommended to define specific Filter MPR perpendicular orientations in each of the Orientation F(feet-head) grouped segments even if Lock Use Data O Both O Base ( Overlay R H. Reference Lines is enabled. Then you 2D Stripe O Enable can forecast the exact view displayed in Reference Line 1 X 4 X 5 X Select each image segment. Template Effective Date: 26 Mar 2025 | QR700020784 52 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Region specific measurements on US Template Effective Date: 26 Mar 2025 | QR700020784 53 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Region specific measurements on US (I) Distance Line The support of region-specific measurements on Distance Line Distance Line Ultrasound images is now available. Distance Polyline ROI Circle .0 Arrow ROI Circle Marker IT ROI Freehand 1 • This feature activates when you use one of 1:0 ROI Auto Contour the following tools: Angle Angle on Stack Angle A Text T Angle on Stack • Text T Distance Line • 1 Distance Polyline • ROI Circle 14cm Z 2 Card TIB:1.0 • ROI Freehand TIC:3.5 TIS.1.0 19fp 959 51bpr Lead Il 2 20 • When you activate one of these tools, the H Hig -6dB/DR5 application displays a green rectangle UA indicating the region where measurements edB/ Genera PRF 4484 are supported. 14cm 616pm Lead Template Effective Date: 26 Mar 2025 | QR700020784 54 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 What’s New in MM SIEMENS Healthineers Region specific measurements on US (II) 3 • When you perform a measurement inside *Card [2] Distance Line TIB:1.04 TIC:3.5 the supported region, the measurement ??? TIS 1.0 4 MI:1.1 ....... 18fp provides you a value. 95% H Hig -BdB/DR5 UA 4 • When you perform a measurement either Mic 2dB/ Genera totally or partially outside of the supported PRF 446 region, the measurement value is ???. ......... 5 5 • The green rectangle disappears when you [2] Distance Line ??? TIS:1.04 deactivate the measurement tool. [1] Distance Line MI:1.1 19fp 0.77 cm 95% 3 20 H High 61bpim Lead -6dB/DR5 UA3 -............... . . . . . . . . . . . . . . . . . . . . . . . . . . . . ........ Mic -2dB/ Genera PRF 4464 :-14cm Z [1] Distance Line 0.77 cm .. 61bpm Lead Il Template Effective Date: 26 Mar 2025 | QR700020784 55 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Please note that this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product-related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration-dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim, Germany Phone: +49 9191 180 siemens-healthineers.com Template Effective Date: 26 Mar 2025 | QR700020784 56 Job Aid Effective Date: 13 May 2025 | QR700023015 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025
- syngovia
- multimodality
- news
- whats new
- delta