
What's New With syngo CT VB20 Overview Job Aid
In this PDF, you will get a quick overview of the improvements and additional functionalities in the syngo CT VB20 software version.
Product relevance: SOMATOM go.Now, SOMATOM go.Up, SOMATOM go.All, SOMATOM go.Top, SOMATOM go.Sim, SOMATOM go.Open Pro, SOMATOM X.cite, SOMATOM X.ceed, SOMATOM Pro.Pulse, NAEOTOM Alpha, NAEOTOM Alpha.Peak, NAEOTOM Alpha.Pro, NAEOTOM Alpha.Prime.
Target group: Basic user, all users.
Recommended to be viewed on the following devices: All (incl. tablet, smartphone).
What’s New With syngo CT VB20 Overview Job Aid NAEOTOM Alpha, NAEOTOM Alpha.Peak, NAEOTOM Alpha.Pro, NAEOTOM Alpha.Prime, SOMATOM X.ceed, SOMATOM X.cite, SOMATOM Pro.Pulse, SOMATOM go.Open Pro, SOMATOM go.Sim, SOMATOM go.Top, SOMATOM go.All, SOMATOM go.Up, SOMATOM go.Now In this PDF, we would like to give you a quick overview of the improvements and additional functionalities in the syngo CT VB20 software version. Some of these additional functionalities listed below may be purchasable options. We have marked them with asterisks (*) and a footnote. For more detailed information, please refer to the respective syngo CT VB20 Improve- ments Job Aids on PEPconnect and / or Instructions for Use. Scanning • myExam Cockpit – Clinical decision trees are now also available for children. • You can now define the Study Description for each protocol using a clinical decision tree. • You can now change the Recon Strategy after scanning, for example to add an iMAR Recon job. • Only for NAEOTOM Alpha, NAEOTOM Alpha.Peak, NAEOTOM Alpha.Pro, NAEOTOM Alpha.Prime, SOMATOM X.ceed and SOMATOM X.cite: Flex 4D Spiral* – You can now manually configure the cycle time parameter and maintain it during scan range selection. This includes additional combinations of scan ranges and cycle times becoming available. Exam Protocols • Only for NAEOTOM Alpha, NAEOTOM Alpha.Peak, NAEOTOM Alpha.Pro and NAEOTOM Alpha.Prime: ‘Liver Perfusion Alt’ is now available with the scan mode Quantumplus. • ‘Liver Intervention’ and ‘Liver Intervention 3D’ are now available with different contrast phases before the interventional procedure. • ‘Brain and Neck Multi Phase CTA’ is now available with different contrast phases as an alternative or additional option for brain perfusion. • CDTI measurement protocols are no longer available because of the new tool CTDI Individual (see General Software Improvements below). Recon • You can now configure two User Texts. Changing of the series description is no longer possible. You can define the User Texts under the General Recon tab. • New FAST planning ranges are: o Both Knees o Carotid Aortic Arch to Skull o Neck and Lung o Neck and Chest ...................................................... * Optional. Please contact your local SIEMENS Healthineers sales representative to get more information on the respective feature(s). Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 21 Apr 2023 | HILS 2224 Job Aid Effective Date: 27 Mar 2025 | QR700017785 Healthineers Job Aid | What’s New With syngo CT VB20 Overview Effective Date: 27 Mar 2025 | QR700017785 • Select All / Deselect All are now available in list boxes. • Only for SOMATOM X.ceed, SOMATOM X.cite, SOMATOM go.Open Pro and SOMATOM go.Top: Improved artifact correction is now available for head imaging. • Only for NAEOTOM Alpha, NAEOTOM Alpha.Peak, NAEOTOM Alpha.Pro and NAEOTOM Alpha.Prime: iMAR is now available with sharper kernels up to 64. General software improvements • CT View&GO Dynamic Angio as part of syngo.CT Dynamic Angio* – The visualization of blood flow is now possible based on time-resolved data. Movies, images and time attenuation curves (TACs) are created to visualize blood flowing from the arterial to the venous phases. This may support the inspection of diseases which affect the vessel system, vascular malformations, control of stent graft extravasation, or the evaluation of tumor vascularization. • CTDI Individual allows you to perform any clinical scan mode as a technical axial scan in order to perform CTDI dose measurements. Medical physicists or trained and qualified personnel with CTDI knowledge can use this function for CTDI dose measurements within their quality assurance program to verify the stated CTDI and its constancy. Sustainability • Not for SOMATOM go.Up and SOMATOM go.Now: Eco Power Mode – New feature to save energy consumption between examinations. FAST 3D Camera** • Collision indication – Before moving the table into the gantry, the software now indicates a potential collision. • Grid overlay – Visual feedback on tablets that shows whether you have positioned the patient straight or rotated by overlaying a grid on the camera image. Quantum Technology • Only for NAEOTOM Alpha, NAEOTOM Alpha.Peak, NAEOTOM Alpha.Pro and NAEOTOM Alpha.Prime: o Spectral Recalibration – Quality assurance workflow for your staff to validate spectral stability. o Additional 120 kV are now available for Quantum scan modes. .......................................................... * Optional. This CT post-processing plug-in is a standalone medical device. Please contact your local SIEMENS Healthineers sales representative to get more information on the respective feature(s). ** Optional. Please contact your local SIEMENS Healthineers sales representative to get more information on the respective featu re(s). SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 2 of 6 Job Aid | What’s New With syngo CT VB20 Overview Effective Date: 27 Mar 2025 | QR700017785 o Not for NAEOTOM Alpha.Prime: QuantumPeak is now available with additional rotation times of 0.5 and 1.0 second. Cardiovascular Imaging* • Cardiac Preview Series – A semi-automatic feature that reconstructs images with different time phases at 2, 5, 10, 20% or 20, 50, 100, or 200 ms intervals on a specific cross- sectional slice from a multi-phase cardiac acquisition. • Only for SOMATOM Pro.Pulse and SOMATOM go.Top: Cardiac Sequence – It is now possible to reconstruct 0.6 mm slices. Neurology Imaging / Stroke Reading • Recon&GO LVO Detection as part of syngo.CT LVO Detection* – Automatic detection of suspected large vessel occlusions (LVO) in the brain, which can assist in ischemic stroke triaging. • Vessel Hyperdensities as part of syngo.CT Vessel Hyperdensities* – Quantification and visualization of intravascular hyperdensities in native non-contrast head CT images. • ASPECTS V2 (in CT View&GO and Recon&GO) as part of syngo.CT ASPECTS* – With the updated ASPECTS version, the software now detects old infarcts and acute infarcts, and in addition to that, now performs orientation correction together with a head-in-the-isocen- ter quality check: The software will notify you in case you have not placed the patient’s head in the scanner’s isocenter. Emergency Imaging / Trauma Reading • CT View&GO Brain Hemorrhage as part of syngo.CT Brain Hemorrhage* – Automatic detection of suspected acute intracerebral hemorrhages is now possible in CT View&GO. • CT View&GO Brain Hemorrhage SAH as part of syngo.CT Brain Hemorrhage* – Automatic detection of suspected acute subarachnoid hemorrhages (SAHs) is now possible in CT View&GO. • CT View&GO Brain Hyperdensity as part of syngo.CT Brain Quantification Brain Hyper- density* – Segmentation and total volume calculation of brain hyperdensities are now possible in CT View&GO. • Midline Shift (in CT View&GO and Recon&GO) as part of syngo.CT Brain Quantification Midline Shift* – This application now enables automatic brain midline shift calculation through automatic identification of landmarks. .............................................. ...................................... * Optional. This CT post-processing application is a standalone medical device. Please contact your local SIEMENS Healthineers sales representative to get more information on the respective feature(s). SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 3 of 6 Job Aid | What’s New With syngo CT VB20 Overview Effective Date: 27 Mar 2025 | QR700017785 Spectral imaging* Only for NAEOTOM Alpha, NAEOTOM Alpha.Peak, NAEOTOM Alpha.Pro and NAEOTOM Alpha.Prime: • New Quantum Spectral application classes are now available (all spectral Quantum func- tionality is part of syngo.CT Dual Energy**) o Quantum VNCa – Visualization of calcium-suppressed images (Virtual Non- Calcium, short VNCa) available for interactive spectral imaging and Recon&GO In- line Results. o Quantum Brain Hemorrhage – DE-based analysis of intracranial hemorrhages based on photon-counting data. o Quantum Direct Angio – DE-based bone removal for head and body based on photon-counting data. o Quantum Hardplaque Display – Visualization of calcified plaques within large vessels even if they have CT values that are comparable to the neighboring contrast agent. o Quantum Rho/Z – Rho/Z analysis based on photon-counting data. o Quantum DirectSPR – Stopping Power Ratio (SPR) analysis for particle therapy based on photon-counting data. • Enhancement of existing Dual Energy (DE) application classes as part of syngo.CT Dual Energy** o Quantum Liver VNC: ▪ Fat Maps – You can now visualize liver fat maps. ▪ Liver ECV – You can now analyze extracellular volume (ECV) in the liver. ▪ You can now perform organ segmentation for Bone Marrow. • Additional SPP (spectral post-processing format) matrix sizes are now available: 768x768 and 1024x1024. Intervention* • CARE Moodlight – The same behavior as for diagnostic ranges is now also available for interventional ranges: A yellow light indicates the emission of radiation. CARE Moodlight visualizes the scan delay by diminishing the white light section. Radiation Therapy Planning* • ZeeFree RT – ZeeFree and TrueStack reconstructions are now available for Respiratory 4D sequence scan modes (Direct i4D). • Oncology Exchange – Connectivity between the Varian Oncology Information System (OIS) ARIA and the Siemens Healthineers syngo CT VB20 software is now established for information exchange. ......... * Optional. Please contact your local SIEMENS Healthineers sales representative to get more information on the respective featu re(s). ** Optional. This CT post-processing application is a standalone medical device. Please contact your local SIEMENS Healthineers sales representative to get more information on the respective feature(s). SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 4 of 6 Job Aid | What’s New With syngo CT VB20 Overview Effective Date: 27 Mar 2025 | QR700017785 • HD FoV 5.0 – AI-supported extended HD Field of View (FoV). • New functionalities are now available within DirectSetup Notes. • DirectLaser – You can now define the isocenter from the tablet. • For NAEOTOM Alpha, NAEOTOM Alpha.Peak, NAEOTOM Alpha.Pro and NAEOTOM Alpha.Prime: o Rho/Z for RT treatment planning o DirectSPR (Stopping Power Ratio) for PT treatment planning o Please note that DirectDensity is not required for spectral imaging. • FAST 3D Camera incl. collision indication and grid overlay are now also available for the RT workflow. Not for NAEOTOM Alpha, NAEOTOM Alpha.Peak, NAEOTOM Alpha.Pro and NAEOTOM • Alpha.Prime: Bolus tracking and injector coupling are now available for TwinSpiral Dual Energy (DE). SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 5 of 6 Job Aid | What’s New With syngo CT VB20 Overview Effective Date: 27 Mar 2025 | QR700017785 Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthi- neers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without ex- press written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. All trademarks are the property of their respective owners. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 6 of 6
- ct
- cth
- vb20
- ro
- overview
- improve
- change