
syngo.via MAMMOVISTA B.smart VB80 What's New Online Training
In this MAMMOVISTA B.smart VB80 What's New Online Training, you will learn about the new features and functionalities that came up between software version VB70 and VB80 in syngo.via.
Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue Continue syngo.via MAMMOVISTA B.smart What's New Online Training Master Template HILS2218 | Effective Date: 25 Mar 2022 ? syngo.via MAMMOVISTA B.smart VB80 What's New Online Training In this training, you will discover the new and updated features available in the MAMMOVISTA B.smart VB80 version. Summarize General Workflow Improvements Outline Transpara™ Enhancements Update Double Blind Reading Inform About Export Settings Changes Describe MR Panel Upgrades Explain Skip Incomplete Comparison Layouts Feature 1 6 5 4 3 2 Welcome Welcome to the MAMMOVISTA B.smart VB80 What's New Online Training. During this session,you will discover the new and updated features available in the syngo.via MAMMOVISTA B.smart VB80 version. Summarize General Workflow Improvements syngo .via | MAMMOVISTA B.smart VB80 ? Summarize General Workflow Improvements ? Layout icon generation (Non-factory layouts) In VB70 – No possibility to view icons for newly created layouts. In VB80 – All users can view icons when creating new layouts (non-factory layouts). The icons appear automatically after selection. Please note: The new created layouts can be identified by a pencil icon in the lower right corner of the layout. Previous syngo.via versions New in syngo.via VB80 Layout icon generation Starting from VB80, all users have the ability to view icons for their newly created layouts. These icons will now appear automatically upon selection. Please note: The new created layouts can be identified by a pencil icon in the lower right corner of the layout. ? New US Overview Layout The newly introduced ultrasound layout called C.US Overview has been implemented. This layout is specifically designed to offer a comprehensive view of all current ultrasound images. It is accessible within the Layout Gallery. To quickly access this new layout, users can click on the US Modality option or utilize the search tool by typing US. Please note: If more than eight ultrasound images are available, the remaining images are loaded into the segments by: Shortcut CTRL+H Next ReportFlow Step button or the Next ReportFlow step shortcut CTRL+F New US Overview Layout A newly introduced ultrasound layout called "C.US Overview" has been implemented. This layout is specifically designed to offer a comprehensive view of all current ultrasound images and is accessible within the Layout Gallery. To quickly access this new layout, users can click on the US Modality option or utilize the search tool by typing "US". Please note: If more than eight ultrasound images are available, the remaining images are loaded into the segments via: Shortcut CTRL+H Next ReportFlow Step button or the "Next ReportFlow step" shortcut CTRL+F. ? Reset Remaining Images In VB70 – No capability to reset the Remaining Images Layout. The user needs to reopen the studies. In VB80 - All users can reset the Remaining Images by simply clicking the Reset ReportFlow button. Subsequently, users regain the ability to visualize the Remaining Images. Please note: After a reset, the Remaining Images Layout will no longer display a yellow bar below its icon, indicating its readiness for opening. Video Reset Remaining Images It is now possible to reset the Remaining Images Layout with a simple click on the Reset ReportFlow button. As a result, users can once again view the Remaining Images. Video Layer: Open all layouts in the Report Workflow and access the Remaining Images Layout. Now in VB80, you can click the Reset Report Workflow button to view the Remaining Images layout again, as many times as needed. Consequently, like the other layouts, the Remaining Images layout will be available and ready to open. Reset Remaining Images Video ? Synced Movie In VB70 – The movie feature in Tomo studies start synchronized at the same start point. After a few rounds, it is no longer synchronized if the Tomo studies contain a different number of slices. In VB80 – Improved movie synchronization from the first Tomo slice to the last. This enhancement is facilitated by the system. This ensures better synchronization by waiting for the last Tomo image with the highest number of slices. Movie Move Now, activate easily the global Movie Move function by pressing SHIFT SPACE. Please click on the marker to learn about the new Global Movie Shortcut. Synced Movie VB80 offers improved movie synchronization from the first Tomo slice to the last. This enhancement is facilitated by the system, which ensures better synchronization by waiting for the last Tomo with the highest number of slices. Please click on the marker to learn about the new Global Movie Shortcut: SHIFT SPACE. Marker: Movie Move Now, activate easily the global Movie Move function by pressing SHIFT SPACE. ? Image Text Upgrades General improvements have been implemented in the Image Text, which include: Enhancing the presentation of the Acquisition Date: More prominent and displayed in bold. Eliminating the indicator message. Previously, when a segment was very small, all image text would either be hidden, or a pop-up indicator would appear. Now, instead of the indicator, three dots are present, allowing you to view the text. Enabling to fully edit and customize the image text without any limitations. Video Image Text Upgrades General improvements have been implemented in the Image Text, which include: Enhancing the presentation of the Acquisition Date, now more prominent and displayed in bold. Eliminating the indicator message. Previously, when a segment was very small, all image text would either be hidden, or a pop-up indicator would appear. Now, instead of the indicator, three dots are present, allowing you to view the text. Enabling customers to fully edit and customize the image text without any limitations. Video Layer: As mentioned previously, the indicator message is no longer present when the segment is very small. Instead, three dots appear. Simply by clicking on these dots, you can view the text that was hidden. Furthermore, in the Viewing Configuration Panel, all text that appears in the images can be edited without any limitations. This means that you have the freedom to customize the text according to your preferences. To finalize and view the changes, please click on "OK". Image Text Upgrades Video Explain New Skip Incomplete Comparison Layouts Feature syngo .via | MAMMOVISTA B.smart VB80 ? Explain New Skip Incomplete Comparison Layouts Feature ? All users can access the feature named Layout Skipping. Navigate to the Configuration Panel. Then select Image Navigation, and Workflow Settings. Please note: Changes will be available after signing out and signing into syngo.via. New Skip Incomplete Comparison Layouts Video New Skip Incomplete Comparison Layouts Video All users can access the feature named Layout Skipping by navigating to the Configuration Panel, then selecting Image Navigation, and finally, Workflow Settings Please note: Changes will take effect after signing out and signing into syngo.via. Furthermore, in VB80, you can generate layouts with the feature of skipping incomplete comparison layout activation. However, this functionality is not present in VB60 and VB70. As a result, layouts from VB60 and VB70 lack comparison group information. If these layouts are included in a ReportFlow and need to be skipped, updating the comparison group configuration is necessary. ? New Skip Incomplete Comparison Layouts The Skip Incomplete Comparison Layouts Feature is situated in the Image Navigation Configuration Tab and is unchecked by default. Please select the tab arrows on the right to explore examples of how the feature functions with comparing and non-comparing groups. Two Comparison groups: 2(Tomo), 2(MG) Two Comparison groups: 1(Mag/Spot), 2(MG) Two Comparison groups: 2(Tomo), 1(MG) & 1 segment without group One Comparison group: US & 2 segments without group No comparison group Skip incomplete comparison layouts A comparison layout is skipped if at least one comparison group (e.g. Current or Prior) is empty. This happens due to missing images and if a meaningful comparison is not possible. New Skip Incomplete Comparison Layouts The new Skip Incomplete Comparison Layouts Feature, which is situated in the Image Navigation Configuration Tab and is unchecked by default. Remember: A comparison layout will be skipped if at least one comparison group (e.g. Current or Prior) is empty due to missing images and a meaningful comparison is not possible. Please select the tab arrows to explore examples of how the Layout Skipping feature functions with comparing and non-comparing groups. Marker: Skip incomplete comparison layouts A comparison layout is skipped if at least one comparison group (e.g. Current or Prior) is empty. This happens due to missing images and if a meaningful comparison is not possible. Tab 1: The layout will be skipped if Tomo volumes or Standard Mammograms are missing. Tab 2: The layout will be skipped if Mag/Spot or Standard Mammograms are missing. Tab 3: The layout will be skipped if Tomo volumes and/or Standard Mammogram are missing. Tab 4: The layout will be skipped if the US image is missing. Tab 5: The layout will be skipped if all images are missing. No Comparison Group The layout will be skipped if all images are missing. One Comparison group: US & two segments without a group The layout will be skipped if the US image is missing. Two Comparison groups: 2(Tomo), 1 (MG) & one segment without a group The layout will be skipped if Tomo volumes and/or Standard Mammogram Right cc are missing. Two Comparison groups: 2(Tomo), 2(MG) The layout will be skipped if Mag/Spot or Standard Mammograms are missing. Two Comparison groups: 2(Tomo), 2(MG) The layout will be skipped if Tomo volumes or Standard Mammograms are missing. Describe MR Panel Upgrades syngo .via | MAMMOVISTA B.smart VB80 ? Describe MR Panel Upgrades ? MR Panel Updates Select any MR Layout from the Gallery as the default MR layout. Simply right-click on any of the MR Layouts and choose Set as MR default layout. When opening the next MR studies, they will appear with the selected default layout and will be marked with a star icon. Click on the tabs on the left to find more information. MR Measurement Propagation MR Measurement Propagation MR Prior Toggling MR Prior Toggling MR Default Layout MR Default Layout MR Default Layout MR Panel Updates Select any MR Layout from the Gallery as the default MR layout. Simply right-click on any of the MR Layouts and choose "Set as MR default layout". When opening the next MR studies, they will appear with the selected default layout and and will be marked with a star icon. Tab 2: Propagate measurements generated in dynamic or subtraction images to other MR images, provided that these images share the same frame of reference across all images. Tab 3: Access previous studies by utilizing the Prior button situated in the top image text section of the MR Panel. Simply click the arrow button to view the prior MR studies. Access prior studies by using the Prior button situated in the top image text section of the MR Panel. Click the arrow button to view the prior MR studies. MR Prior Toggling Propagate measurements created in dynamic or subtraction images to other MR images with the same frame of reference across all images. MR Measurement Propagation Outline Transpara™ Enhancements syngo .via | MAMMOVISTA B.smart VB80 ? Outline Transpara™ enhancements ? Transpara™ Enhancements In the Custom Image Text configuration, there is a new addition: The Transpara Highest Region Score. This score ranges from 0 to 100. Please note: Only available for Transpara™ Version 1.7.2 or higher. Click on the tab on the left to find more information. Transpara Breast Density Transpara Breast Density Transpara Highest Region Score Transpara Highest Region Score Transpara Highest Region Score Transpara Highest Region Score Configurations Located in Viewing Panel → Configuration Panel → Custom Image Text Transpara™ Enhancements In the Custom Image Text configuration, there is a new addition: the Transpara Highest Region Score. This score ranges from 0 to 100. Please note: Only for Transpara™ Version 1.7.2 or higher. Marker 1: Transpara Highest Region Score Configurations Located in Viewing Panel → Configuration Panel → Custom Image Text Tab 2: When a report from Siemens Healthineers, Volpara, iReveal Density, or Transpara (version 1.8 or newer) is available, or when there is breast density information within the image (such as Siemens Healthineers Insight BD), the breast density values are shown on both digital mammography and tomosynthesis images. Marker 2: Breast Density Configuration Located in Viewing Panel → Configuration Panel → Custom Image Text When a report from Siemens Healthineers, Volpara, iReveal Density, or Transpara (version 1.8 or newer) is available, or when there is breast density information within the image (such as Siemens Healthineers Insight BD), the breast density values are shown on both digital mammography and tomosynthesis images. Transpara Breast Density Breast Density Configuration Located in Viewing Panel → Configuration Panel → Custom Image Text Update Double Blind Reading syngo .via | MAMMOVISTA B.smart VB80 ? Update Double Blind Reading ? Screening Case Detection Improvement This new feature for quotations allows users to be specific when linking the study description and assigning the Double Blind mode. New supported formatting: Group words into quotes to require word order, spaces, and commas within the quotes to match specific studies. For example: "Tomo S" Study Description Located in Viewing Panel → Configuration Panel → General Tab Screening Case Detection Improvement There is a new feature for quotations that allows users to be specific when linking the study description and assigning the Double Blind mode. New Supported formatting: Group words into quotes to require word order, spaces, and commas within the quotes to match specific studies. For example: "Tomo S". Marker: Study Description Located in Viewing Panel->Configuration Panel-> General Tab ? Automatic ReportFlow Assignment Improvement It is now possible to set the same quotation in the Automatic ReportFlow Assignment. New supported formatting: Group words into quotes to require word order, spaces, and commas within the quotes to match: For example: “Tomo BTO" Automatic ReportFlow Assignment Located in Viewing Panel → Configuration Panel → Image Navigation Automatic ReportFlow Assignment Improvement Now it is possible to set the same quotation in the Automatic ReportFlow Assignment. New Supported formatting: Group words into quotes to require word order, spaces and commas within the quotes to match: For example: "Tomo BTO". Marker 1: Automatic ReportFlow Assignment Located in Viewing Panel ->Configuration Panel -> Image Navigation ? Display of Measurement Owner The Consensus Reader is equipped to evaluate the findings from all Double Blind Readers without facing any restrictions. For example, regarding the visibility of measurements or the creation of findings. Moreover, the Consensus Reader can identify the owner of the measurements available through the measurement information box. Display of Measurement Owner The Consensus Reader is equipped to evaluate the findings from all Double Blind Readers without facing any restrictions regarding the visibility of measurements or the creation of findings. Moreover, the Consensus Reader has the ability to identify the owner of the measurements available through the measurement information box. Inform About Export Settings Changes syngo .via | MAMMOVISTA B.smart VB80 ? Inform About Export Settings Changes ? Export Data to File System/Optical Disc When exporting data to the file system or optical disc, there have been some changes in the visualization. In VB80, the option previously labeled as Anonymize As, is now renamed in Data Minimization. It offers the options of the Profile and Pseudonym. Nevertheless, their functionality remain the same. Previous syngo.via versions New in syngo.via VB80 Export Data to File System/Optical Disc When exporting data to the file system or optical disc, there have been some changes in the visualization. In VB80, the option previously labeled as Anonymize As is now renamed in Data Minimization, offering the options of the Profile and Pseudonym. Nevertheless, their functionality remain the same. ? Media Burning Profiles (Configuration Panel) Previous syngo.via versions New in syngo.via VB80 Video Media Burning Profiles (Configuration Panel) A new visualization has been introduced in the Configuration Panel for Media Burning Profiles. For more detailed information on how to configure it, please click on the Video button. Video: To get started, access the Configuration Panel by navigating to the top right corner of syngo.via and clicking on it. Then, select "Export." This action will prompt the appearance of the Media Burning Profile Configuration. From there, either create a new profile or select an existing one. For editing purposes, click on "Edit.“ Check the box labeled "Data Minimization" to activate this feature. Once checked, you will be able to customize the Profile according to your preferences. To finalize, click on "Apply" and then "OK" to ensure that the changes are applied. Media Burning Profiles (Configuration Panel) video ? Data Minimization Profiles High Privacy (formerly Full): Most of the original patient information is removed. The Patient Name is changed to Pseudonym but can be modified by the user. Reduced Privacy (formerly Reduced): Most of the original patient information is removed, except the following: Temporal information, e.g., examination date Certain patient characteristics, e.g., age, size, weight, pregnancy status. Low Privacy (formerly Service): Designed only for service use cases. Data Minimization Profiles Currently, updates have been made to the Data Minimization Profiles. Under the High Privacy category (previously referred to as "Full"), most of the original patient information is eliminated. The Patient Name is replaced with "Pseudonym," although users have the option to modify it. In the Reduced Privacy category (formerly labeled as "Reduced"), the majority of the original patient information is removed, with the exception of specific details such as temporal information (e.g., examination date) and certain patient characteristics (e.g., age, size, weight, pregnancy status). Lastly, the Low Privacy category (previously known as "Service") is tailored exclusively for service-related use cases. ? Course Review Congratulations. You have completed the syngo .via MAMMOVISTA B.smart VB80 What's New Online Training. Select the numbered buttons below to review the material before proceeding to the final assessment. Update Double Blind Reading Outline Transpara™ Enhancements Explain New Skip Incomplete Comparison Layouts Feature Summarize General Workflow Improvements 1 1 2 2 2 4 4 Describe MR Panel Upgrades 3 3 3 5 5 Inform About Export Settings Changes 6 6 Course Review Inform About Export Settings Changes In the chapter Export Settings Changes you learned about the following: Data export to the file system or optical disc, previously labeled as Anonymize As has been renamed Data Minimization. Media Burning Profiles, accessible through the Configuration Panel, now include the Data Minimization Profiles. High Privacy Profile: Most of the original patient information is removed. The Patient Name is changed to Pseudonym but can be modified by the user. Reduced Privacy Profile: Patient information is removed except temporal information, e.g., examination date and certain patient characteristics, e.g., age, size, weight, pregnancy status. Low Privacy Profile: Designed only for service use cases. Update Double Blind Reading In the chapter Update Double Blind Reading you learned about the following: Screening Case Detection with quotes in study description. Automatic ReportFlow Assignment with quotes in study description. Displaying Measurement Owner to identify the owner of the measurements. Outline Transpara™ Enhancements In the chapter Outline Transpara™ Enhancements you learned about the following: Transpara Highest Region Score: This score ranges from 0 to 100. Transpara Breast Density: Breast density values are displayed on both digital mammography and tomosynthesis images when a report from Siemens Healthineers, Volpara, iReveal Density, or Transpara (version 1.8 or newer) is available. Activating the New Transpara Features. Describe MR Panel Upgrades In the chapter MR Panel Upgrades you learned about the following: Setting MR Default Layout: Simply right-click on any MR Layout, then choose Set as MR default layout. MR Measurement Propagation: Easily transfer measurements made in dynamic or subtraction images to other MR images. MR Prior Toggling: Access prior studies by using the Prior button in the top image text section of the MR Panel. Explain New Skip Incomplete Comparison Layouts Feature In the chapter Skip Incomplete Comparison Layouts Feature you learned about the following: Accessing the Skip Incomplete Comparison Layouts Feature. Activating the Skip Incomplete Comparison Layouts Feature. Understanding how a comparison layout will be skipped if at least one comparison group is empty due to missing images. Recognizing multiple examples when the comparison layout will be skipped. Summarize General Workflow Improvements In the chapter General Workflow Improvements you learned about the following new improvement in MAMMOVISTA B.smart VB80: Layout Icon Generation: Users can now view icons when creating new layouts (excluding factory layouts). Newly Implemented Ultrasound Layout: Introducing C.US Overview layout. Reset Remaining Images Layout: Easily reset the layout with a simple click on the Reset ReportFlow button. Improved Movie Synchronization: Enhancements in movie synchronization from the first Tomo slice to the last. Prominent Acquisition Date: The acquisition date is now displayed more prominently and in bold. Expanded Image Text Functionality: Users can now access hidden text by clicking on three dots within the image, allowing for customizable image text without limitations. Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com ? Disclaimer Assessment Start ? This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate . Assessment questions must be answered completely to receive full credit. Partial credit will not be given for assessment questions that require multiple answers. You may repeat the assessment as many times as needed. Assessment Select the best answer. ? MR Default Layout MR Display Color Overlay Question 1 of 6 Which new feature in the MR Panel enables users to view their prior MR studies in a highly intuitive manner? MR Prior Toggling MR Measurement Propagation Multiple Choice This is not the correct answer. This is not the correct answer. This is not the correct answer. ? Select the best answers (3 answers are correct). Question 2 of 6 What are the latest upgrades to the image text? Making the Acquisition Date more prominent. Presenting an indicator message when the segment is very small. Providing full accessibility to edit and customize the image text. Introducing three dots to reveal hidden text. Multiple Answer One or more answers are incorrect. Select the applicable image. ? Which option corresponds to the new ultrasound layout? Question 3 of 6 Pick One You haven’t selected the correct image. You haven’t selected the correct image. Select the best answer. ? Low Privacy Medium Privacy Question 4 of 6 If your customer likes to export data with most of the original patient information removed, which Data Minimization Profile should they choose? Reduced Privacy High Privacy Multiple Choice This is not the correct answer. This is not the correct answer. This is not the correct answer. Select the best answer. ? A comparison layout will be skipped if all the comparison groups are full of images. A comparison layout will be skipped if all the comparison groups contain images. Question 5 of 6 Which sentence describes how the new layout skipping feature works? A comparison layout will be skipped if at least one comparison group contain images. A comparison layout will be skipped if at least one comparison group is empty due to missing images. Multiple Choice This is not the correct answer. This is not the correct answer. This is not the correct answer. Select the best answer. ? Screening Case Detection Improvement (quotes). Display of Measurement Owner. Question 6 of 6 What is not included in the latest updates in Double Blind Reading? Automatic ReportFlow Assignment Improvement (quotes). Consensus Reading. Multiple Choice This is not the correct answer. This is not the correct answer. This is not the correct answer. Assessment Results YOUR SCORE: PASSING SCORE: Review Retry Retry Continue Continue Continue %Results.ScorePercent%% %Results.PassPercent%% ? Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course.. Exit To access your Certificate of Completion, select the Certificates tab from the learning activity overview page. You can also access the certificate from your PEPconnect transcript. ? You have completed the syngo .via MAMMOVISTA B.smart VB80 What's New Online Training. Completion details, certificates tab Navigation Help Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Tmeline Select the buttons to learn more about a topic. Be sure to review all topics before navigating to the next slide. Click Next to continue. Next Tab Arrow Slide Select the X to close the pop-up. Click Next to continue. Next Layer Slide Some images may have a magnifier icon. Select the image to see an enlarged view. Select it again to return to the normal view. Click Next to continue. Next Zoom Slide Some images have a magnifier icon in the bottom-left corner. Select these image to see an enlarged view of the image. Select the image again to return to the normal view. Videos should default to the optimal resolution. However, to change the video resolution select the gear icon. Click Next to continue. Next Video Slide Some images have a magnifier icon in the bottom-left corner. Select these image to see an enlarged view of the image. Select the image again to return to the normal view. Select Submit to record your response. Click the X in the upper right corner to exit the navigation help. Assessment Slide Question Bank 1 QR700006943 | Effective Date: 02 Apr 2024 1.1 Welcome 1.2 Summarize General Workflow Improvements 1.3 Layout icon generation 1.4 New US Overview Layout 1.5 Reset Remaining Images 1.6 Synced Movie 1.7 Image Text Upgrades 1.8 Explain New Skip Incomplete Comparison Layouts Feature 1.9 New Skip Incomplete Comparison Layouts Video 1.10 New Skip Incomplete Comparison Layouts 1.11 Describe MR Panel Upgrades 1.12 MR Panel Updates 1.13 Outline Transpara™ enhancements 1.14 Transpara™ Enhancements 1.15 Update Double Blind Reading 1.16 Screening Case Detection Improvement 1.17 Automatic ReportFlow Assignment Improvement 1.18 Display of Measurement Owner 1.19 Inform About Export Settings Changes 1.20 Export Data to File System/Optical Disc 1.21 Media Burning Profiles (Configuration Panel) 1.22 Data Minimization Profiles 1.23 Course Review 1.24 Disclaimer 1.25 Assessment
- syngovia
- syngo via
- mammo
- mammovista bsmart
- mammovista b smart