<i>syngo</i> RT Therapist 4.3 MR - Automatic Motion Protection Job Aid

syngo RT Therapist 4.3 MR - Automatic Motion Protection Job Aid

This PDF provides an overview of the Automatic Motion Protection on the syngo RT Therapist 4.3 MR.

SIEMENS Healthineers syngo RT Therapist 4.3 MR3 Automatic Motion Protection(AMP) Job Aid Template Effective Date: 01/08/2018 | HOOD05162002751995 Effective Date: 05/13/2019 | HOOD05162002997200 Job Aid Effective Date: 05/13/2019 | HOOD05162002997200 Unrestricted © Siemens Healthcare GmbH, 2019 Table of Contents SIEMENS Healthineers Overview 3 Table Positioning 4 Safety and Security 5 System Messages 6 ... 2 Effective Date: 05/13/2019 | HOOD05162002997200 Unrestricted © Siemens Healthcare GmbH, 2019 Overview SIEMENS Healthineers • Automatic Motion Protection (AMP) is a new Collision Protection software module of the Control Console starting with CC version V13.1.002. • AMP checks for autosequences the current and the final positions of the gantry and the table. It is only active while the Control Console is in a setup state between treatment segments. • If AMP stops automatic movement a message appears and shows the possible collisions and options. F1 QUIT Possible collision: Press RAD ON key to continue, F1 to terminate. 10. GANTRY POSITION • You can move from the Console with F12 and then Alt + Enable or inside the treatment room with the hand control. F1 QUIT Pressing Alt & ENABLE will cause Gantry motion. 10. GANTRY POSITION Overview 3 Effective Date: 05/13/2019 | HOOD05162002997200 Unrestricted © Siemens Healthcare GmbH, 2019 Table Positioning SIEMENS Healthineers • The vertical clearance and the table width can be adjusted by the Vertical Siemens Service. 44 cm • The Control Console increases the entered table dimensions by the following amount: o 5 mm on each side in the lateral and longitudinal direction (-(G-w)|3-2) (0|h) o 20 mm on each side in the vertical direction (-(G-w)|2-4). Patient • Additional dimensions taken into account Tabletop Lateral o Dimension of the MLC and HPD covers W o Dimension of the accessory holder o Dimension of the accessory holder with inserted accessory in slot #3 o Dimension of the MLC/HPD with inserted ModuLeaf Table 4 Positioning Effective Date: 05/13/2019 | HOOD05162002997200 Unrestricted © Siemens Healthcare GmbH, 2019 Safety and Security SIEMENS Healthineers Always be aware of the following points as the AMP does not take these into account: • Consider the area below the treatment tabletop, for example the table base and the table control panel or the bellow. • Consider any additional modifications of the dimensions after they have been parameterized by the Siemens Service, for example immobilization devices. • Consider any individual particularities of the patient as the AMP only takes the predefined vertical clearance into account. • Consider the flat panel positioners. • Consider that the AMP is not active during manual movement of the gantry, the treatment table, or the collimator. • It is the operator’s responsibility to consider any particularities, for example the individual size of a patient, modified covers, individual attached parts. Safety and 5 Security Effective Date: 05/13/2019 | HOOD05162002997200 Unrestricted © Siemens Healthcare GmbH, 2019 System Messages SIEMENS Healthineers • If a potential collision is calculated, one of the following messages is displayed on the Control Console: o Possible Collision: Press RAD ON key to continue, F1 to terminate o Possible Collision: Clear interlocks or press F1 to terminate • In both cases, it is recommended to manually move the accelerator components to the next position using the hand control. Watch out for potential collisions. • The update of the Control Console to version 13.1.xxx activates the Automatic Motion Protection system (AMP) by default. • If the Automatic Motion Protection system (AMP) is deactivated, you are notified by one of the following Control Console messages: o Keyboard in REMOTE MODE (AMP OFF) o Keyboard in REMOTE MODE – CLEAR to cancel (AMP OFF) o Keyboard in REMOTE MODE – CLEAR to terminate (AMP OFF) System 6 Messages Effective Date: 05/13/2019 | HOOD05162002997200 Unrestricted © Siemens Healthcare GmbH, 2019 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 siemens.com/healthineers 7 Effective Date: 05/13/2019 | HOOD05162002997200 Unrestricted © Siemens Healthcare GmbH, 2019

  • syngo
  • AMP
  • RT
  • therapist
  • Automatic
  • Protection
  • motion
  • snygo
  • terapist