BioMatrix Spine 32

BioMatrix Spine 32

This video is an introduction to the BioMatrix Spine32, including practical application tips.

This video introduces you to the handling of the biomatrix fine coil 32. In addition, you'll learn some handy application hints. The handling of the spine coil is applicable to all available biomatrix fine coils. An can be perfectly combined with other coils. Biomatrix fine coils can be equipped with two respiratory sensors. The sensors are indicated by labels on the cushion support. The sensors can be used for both feet first and head first positioning hint before using the coil. Attached the cushion support to the spine coil or use the optional easy exchange cushion on the spine coil. Please note that you should only use the coil with a cushion on it. Position the coil on the patient table. Hold the spine coil using both the handles on the two sides to keep it horizontal that is parallel to the tabletop and not at an angle. When the spine coil is flat on the table top, slide the spine coil tored the foot end of the table so that the lever is positioned in the guides and the coil plugs lock into the coil socket 7 and eight. Turn the lever to lock the coil in. Place a message stating that the coil is correctly plugged in will be shown in the PD. When you position the patient in head first orientation, the patient's head can be positioned either in the head neck coil or in line with the back of the head cushion. Then position the table cushion at the foot end of the patient table. When using the head cushion, place it on top of the head, he'll insert. Position the patient in the supine position and as straight as possible in the center of the coil. Align the patient's head with the picture on the head heel insert. Used positioning AIDS to ensure patient comfort. For most patients in this position, the respiratory sensors are in the correct physiological position in terms of sternum coverage to supply a correct respiratory signal. Kent for children and small patients with a shorter upper body. The position of the sensor will probably not be correct. Examine these patients in the feet first. Orientation to ensure that you were able to obtain a correct respiratory signal. When positioning the patient feet first, for instance in the lumbar spine examination, the Feetfirst positioning pillow has to be used in the heels must be placed exactly in the cavities provided by the cushion. This will ensure the spine is located inside the spine field of view of the coil. Hint this is not applicable for patients taller than 205 centimeters. The respiratory signal will be displayed on the selecting go displays in the physio menu as soon as the patient is positioned correctly. As long as the patient is not registered, only the mean value of both sensors will be shown. When patient registration is complete, only the signal of the corresponding sensor head first or feet first will be recognized. the spine coil, put the table in the home position, pull the release lever of the coil and shifted into the horizontal position. Then press the release at the Patient table an lift the coil with both handles. Take care to ensure that the coil is completely pulled out before lifting it so as to prevent damage when the spine coil is not in use, store it horizontally, for example on a shelf. If the spine coil has to be stored in a vertical position, position it with the coil plugs at the top.

SIEMENS SIEMENS . Healthineers Healthineers Healthineers SIEMENS SIEMENS . Healthineers Healthineers SIEMENS . Healthineers SIEMENS No patient registered Healthineers @ Siemens Healthcare GmbH, 2018 SIEMENS Healthineers SIEMENS . SIEMENS Tablo Position Healthineers Table Position Healthineers Please note that the learning material is for training purposes only! patient Resp For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use Coils SIEMENS . (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as BM spine 32 Healthineers Spine 32 T-Spine" training material only and shall by no means substitute the Operator Manual. Any material used in this training Healthineers will not be updated on a regular basis and does not necessarily reflect the Latest version of the software and Spine 32 hardware available at the time of the training. SIEMENS . SIEMENS . A coil A "Bio Matrix Coil Healthineers Spine 32 MAGNETOM SIEMENS . MAGNETOM The Operator Manual shall be used as your main reference, in particular for relevant safety information like COIL PLUGGED A coil Healthineers warnings and cautions. MAGNETOM Note: Some functions shown in this material are optional and might not be part of your system. The information Spine" MAGNETOM Spine 32 in this material contains general technical descriptions of specifications and options as well as standard and The reproduction, transmission or distribution of this training or its contents is not permitted without express BM spine 32 A coil optional features that do not always have to be present in individual cases. written authority. Offenders will be liable for damages. Spine" Spine 32 A coil A "Bio Matrix Coil A BioMatrix System Certain products, product related claims of functionalities described in the material (hereinafter collectively ALL names and data of patients, parameters and configuration dependent designations are fictional and ALI names and data of patients, parameters and configuration dependent designations are fictional and A coil A coil "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the examples only. future availability of said Functionalities in any specific country is not guaranteed. Plaese contact your local Siemens Healthineers sales representative for the most current information. AIL rights, including rights created by patent grant or registration of a utility model or design, are reserved.

  • spine 32
  • spine coil
  • spine 72
  • spine 24
  • respiratory sensors
  • spine 48
  • sensors
  • respiratory
  • patient positoning
  • plug in
  • plugin
  • leverage
  • xchange-cushion
  • spine
  • trigger
  • triggering
  • breath
  • breathing
  • free-breathing
  • free breathing