Siemens Healthineers Academy
SmartSimulator Workbook - Basics: MR View&GO XA70

SmartSimulator Workbook - Basics: MR View&GO XA70

This workbook will guide you through your lab sessions with MAGNETOM systems based on XA70 in the SmartSimulator. The material in this Basics: MR View&GO workbook is based on the Numaris X platform’s general features and includes a description of the scan user interface.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet and smartphone)

SIEMENS Healthineers SmartSimulator workbook Basics: MR View&GO MAGNETOM systems XA70 smartsimulator.siemens-healthineers.com/ SIEMENS Healthineers MAGNETOM Altea Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Effective Date: 12 Nov 2024 | QR700015739 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Table of contents Foreword 3 Disclaimer 4 Online training for MR View&GO 5 MR View&GO Patient Browser (Local Data) 6 Patient Browser (Local Data) 6 Patient Browser (Local Data): Searching studies with filters 10 Loading a patient to advanced post-processing workflows 35 MR View&GO: Viewing and displays 39 MR View&GO: Overview 40 MR View&GO: Viewing 41 Save and archive results 59 Corner menus and context menu 62 MR View&GO: 3D Post-processing (MIP and MPR) 89 Self-assessment for MR View&GO 103 Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 2 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Foreword Dear participant, Welcome to the SmartSimulator workbook. This workbook guides you through your lab sessions with MAGNETOM systems based on XA70 in the SmartSimulator. The content of this workbook might take you approx. 8 hours while practicing with your MAGNETOM SmartSimulator. Make the most of it. Have some fun and explore what it can do. The material in this Basics: MR View&GO workbook is based on the Numaris X platform’s general features and includes a description of the post- processing MR View&GO general operations. Good luck and we hope you enjoy your SmartSimulator experience. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 3 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means be regarded as a substitute for the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product-related claims, or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of these Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the latest information. The reproduction, transmission, or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration- dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthineers AG 2024 Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 4 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Online training for MR View&GO Before you undertake the following exercises, please follow the links below to learn more about MR View&GO: Outside US MR View&GO Basic Online Training MR View&GO Advanced Online Training US MR View&GO Basic Online Training MR View&GO Advanced Online Training Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 5 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 MR View&GO Patient Browser (Local Data) To learn more about the Patient Browser, please follow the link below: Outside US Patient Browser Video US Patient Browser Refresh Video Patient Browser (Local Data) Exercise: Explore the filter and search options 1. Click on the Patient Browser icon. 2. Select More Filters. Then click on Study Date and Time. Select an option from the drop-down or enter filter criteria to view the updated result list. 3. In the Quick Search field, search by name, ID, date, description, or modality. For a direct search, you can enter, for example, name and ID. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 6 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Patient Browser Local Data earch by Name, ID, Date, Description and Modality (Ctrl+F) Q More Filters Results (69 results, 9:38:59 AM) More Filters Patient Name Patient ID Date of Birth Study Date a .... Patient Name Last Name, First Name of Middle Name orrected View&GO Dat ... 123456789 1/28/1991 1/28/2021 9in Aera Abdomen Germany_MAC 8/14/2020 8/14/2020 8: Patient ID Aera_Abdomen Germany_MAC 8/1/1966 8/13/2020 9 Aera Neck Austria MAC 3/1/1955 8/11/2020 2: Aera_Knee Germany_MAC 8/1 1/2020 8/11/2020 12 ... Accession Number Aera Heart Germany MAC 8/5/2020 8/4/2020 9:5.1 Aera_Knee Germany_MAC 7/31/2020 7/31/2020 11 Study Date and Time From To All day Study Description 4 X + Search Save Work Remove Add 2 List Condition 5 6 Patient Browser (Local Data): Work lists Now let’s find studies within the work lists with predefined queries. Up to five work lists are shown in the work list bar. Exercise: Create a work list 1. Clear an entry in the Quick Search field by selecting X. 2. Select More Filters. 3. Enter the search criteria in the Search Condition fields. 4. Add or remove search fields as needed. 5. In the More Filters area, select the Save Work List icon. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 11 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 More Filters 2 More Filters Patient Name Brain 3 Patient ID Accession Number Study Date and Time From To All day Study Description 5 + Save Work Reset Add List Condition 6. The Save Work List dialog box opens. 7. Enter the name of the work list. This creates a work list using the filters entered, and makes the work list available for all users. 8. Make the work list available for all users. Check the box Available for all users. This checkbox is only visible for clinical administrators. 9. Select OK. Save Work List ? X Name Brain 7 8 Available for all users 9 OK Cancel Exercise: Arrange the order of the work lists Drag and drop the work lists to arrange the order of the work lists in the work list bar. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 12 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Exercise: Delete a work list 1. Select a work list. 2. Right-click and select Delete. Patient Browser Local Data Brain * (52) Cardiac * Apply Search by Name, ID, Date, Description and Modality Remove from Work List bar Overwrite Results (O results, 7:45:01 PM) Restore Delete Patient Name Patient ID Properties 3. In the Delete Work List window, select Yes. Delete Work List AF ? X ? Are you sure you want to delete the selected work list? Yes No Patient Browser (Local Data): DICOM Query/Retrieve Exercise: Search for prior studies on external media or DICOM nodes and import them into the system 1. Go to the toolbar and select the DICOM Q/R icon. 2. Source Selection: Select the source to search for studies. 3. Search Filters: Specify the search criteria. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 13 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 4. Select the Search icon. 5. Select a study. 6. Select the Retrieve icon to retrieve a study. Once the retrieve process is finished, the study is shown in the Results list. DICOM Query/Retrieve ? X Source Selection 2 3 Search Filters 4 Q 6 Results Series Patient Name Patient ID Date of Birth Series Number Series Descripti ... Modality Patient Browser (Local Data): Import images Exercise: Import data from external media or Windows file system 1. Go to the toolbar and select the Import button. View&GO Print Open Open with DICOM Import Export Correct Delete Q/R 2. In the file browser, select the data to be imported. 3. Select the Import button. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 14 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Import . MED_SYSTEM DC) Name Size Date CunitamerSeq CintomerSeqParamCantCont DicomExport DICOMTestimages ScreenCapture temp Import Cancel Please note: First, you need to import the files of interest into the SmartSimulator training portal. Then you can retrieve the files from the Patient Browser. Patient Browser (Local Data): Export images To learn more, please follow the link below: Outside US Distribution Video US Distribution Video Exercise: Explore how to export data 1. Go to the toolbar and select the Export icon. View&GO Print Open Open with DICOM Import Export Correct Delete Q/R Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 15 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 2. You can export the following data: • Completed patient data • Selected studies and series • Single images 3. You can export the selected data in DICOM format to the following destinations: • File system • DICOM nodes • CD/DVD Export Data Patient Series des Instances Optical Disc File System · Network SiemensTest, Abdomen Phoenix ... 15 Storage space sufficient Destination C:\ Browse Properties Compressed Create DICOM File System Indude Image Viewer on Disc Image Conversion Enhanced Anonymize As ... Reduced 1.4 MB, 15 Instances Clear List Export Close Exercise: Export data to a file system or to shared network drives 1. Export the DICOM data to a local file system or to shared network drives by using the Export Data dialog box. 2. Select the patient data to be exported. 3. Select the Export icon. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 16 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 4. The Export Data dialog window opens. 5. Select File System. 6. Select the destination. 7. Under Properties, check Create DICOM File System. 8. Select Export. Export Data 5 Patient Series des ... Instances · Optical Disc File System ® Network MR_Neurology T1 MP.R ... 1 Storage space sufficient Destination Ca 6 Browse Properties Compressed Create DICOM File System Include Image Viewer on Disc 7 Image Conversion Enhanced Il Anonymize As ... Reduced 20.9 MB, 1 instance Clear List 8 Export Close Exercise: Export data to other DICOM nodes Export DICOM data to other DICOM nodes by using the Export Data dialog box. 1. Select the patient data to be exported. 2. Select the Export icon. 3. The Export Data dialog window opens. 4. Select Network. 5. Select a destination. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 17 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 6. Select Export. Export Data 4 ? X Patient Series des .. Instances Optical Disc . File System . Network MR_Angiography angio_A. 96 Destination All nodes 5 MR_Angiography angio_n. 08 MR_Angiography angio_n 96 MR_Angiography angio_ 96 MR_Angiography angio_fl 96 MR_Angiography angio_n. 96 MR_Angiography angio_n MR_Angiography angio_Al ... MR_Angiography angio_a. 00 MR_Angiography angio_n 00 MR_Angiography angio MR_Angiography angio_n 96 MR_Angiography angio_Al 96 MR_Angiography angio_nl 96 MR_Angiography angio_n. MR_Angiography angio_f. 140 MR_Angiography angio_n. 054.9 MB, 1264 Instances Clear List 6 Export Close Exercise: Export data to a CD or DVD Export the DICOM data to a CD or DVD by using the Export Data dialog box. 1. Select the patient data to be exported. 2. Select the Export icon. 3. The Export Data dialog window opens. 4. Select Optical Disc. 5. Drive: Select a drive. 6. Action: As an action, select Burn. 7. Media Label: Select a media label. 8. Enter the CD or DVD label. A limit of six characters, numbers, and underscore is allowed. 9. Profile: Select a profile. 10. Select Export. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 18 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Please note: Do not use lossy compression if images are to be used for diagnosis. To store patient data, use only media approved for medical applications. Export Data Patient . Series des ... Instances Optical Disc File System . Network MR_Angiography angio_f 96 @ Target capacity not avail MR_Angiography angio_f1. MR_Angiography Drive No disc recorder angio_fl .. 96 MR_Angiography angio_ 96 Action Burn MR_Angiography angio_fl. 96 Media Label 2105060819 MR_Angiography angio_fl 96 The media label will only contain the two parts of the MR_Angiography angio_f Media Label information displayed above. Make sure that you can identify the patient from the text that you MR_Angiography angio_fl .. 00 enter here. MR_Angiography angio Profile Standard MR_Angiography angio_f. 00 Compressed MR_Angiography angio_f. Create DICOM File System MR_Angiography angio_nl 96 Include Image Viewer on Disc MR_Angiography angio_fl 96 Image Conversion MR_Angiography angio_fl 96 Enhanced MR_Angiography angio_fl .. Anonymize As. Full MR_Angiography angio_fl ... 140 MR_Angiography angio_f 854.9 MB, 1264 Instances Clear List Export Close The system responds with notification messages, for example as seen above: Target capacity not available. Patient Browser (Local Data): Job View The Job View icon activates the Media Job View area. This area provides an overview of pending, running, and executed jobs: • Filtering and sorting jobs • Restarting jobs • Retrying failed jobs Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 19 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 • Deleting jobs Exercise: Explore the Job View area’s general information SIEMENS Healthineers ABR Job View Ox Short Term Storage Maintenance ELatua Total No. Of Obj .. | Progress Wurkfuw Label Data Publisher MR Reconstructions VAWGOD Dala .. Completed 247 Media Network Print Worklows 1. Click on the Job View icon to open the Job View control area. Select a job type. • Status column: Current job status is displayed. • Progress column: Percentage of completion of the job is displayed. 2. Job list: Select a job to view the corresponding information in the Message field. Please note: Even after the message field has displayed a result, the corresponding data may not yet be available for processing. Patient Browser (Local Data): Export and archiving of data (images) Please note: You can archive only on certified archive devices. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 20 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Exercise: Explore the Export to PACS function or the corresponding DICOM node 1. Please ensure that the system is connected to a PACS or a corresponding DICOM node. 2. To select data for archiving, proceed as follows: • In the Results list, select any studies, series, or instances. • Right‐click and select Set Archive state > Mark for Archiving. Patient Browser Local Data Search by Name, ID. Date, Description and Modality (Ctrl-F) Q More Filters Results (52 results, 8:53:47 PM) Patient Name Patient ID Date of Birth Study Date and ... Study Descripti ... Accession Nu ... Wo MR_Cardiac_Analysis 9/6/2017-12: ... Heart Vi Full ... XA10 MR Cardiac Analysis Open Ctrl+O 1/26/2016:3: ... Head Sk CSF ... VE11 MR_Cardiac_Analysis Open with 10/19/2011 4 ... Heart Av Inf ... VB17 MR Cardiac_Flow View as Read-Only with 7/11/2011 8: ... Cardiac^Stan ... MR Neuro3D Batch Open 7/22/2016 2: ... Head Pr_Full VE11 MR Neuro3D 5/3/2016 2:2 ... Head Pr fMRI ... VE11 MR_Neuro3D Assign Workflow 2/3/2016 3:5 ... Cervical Pr_D ... VE11 MR Neurology Cancel Workflow 7/5/2018 3:3 ... Head 5k Hyd ... VE11C MR_Neurology Search Patient with DICOM Q/R 2/19/2016 8: ... Head Pr_Tum ... VE11 MR_Neurology MR_Neurology Add to Demo List 3/9/2015 1:2 ... Head Ae Alz ... VD13 4/22/2014 12 ... Head Sk Hyd ... VD13 MR Neurology Remove from Demo List 7/25/2012 10 ... Head Ae Stro ... MR_Oncology Set Mark state 11/18/2015 7 ... Head Sk Curt ... VE11 MR_Oncology Set Delete Protection state 11/12/2015 4 ... Head Sk Prior VE11 MR_Oncology To Mark for Archiving VD13 MR_Oncology Set Archive state VD11 MR_Oncology_Onco_Tren Remove Correction state Prevent from Archiving VD138 MR Oncology Onco Tren New Examination 5/7/2015 8:0 ... Onco Trend VD138 Please note: Archiving starts as defined in the Administration Portal. 3. To archive data manually, proceed as follows: • In the Results list, select any studies, series, or instances. • Select the Send to Archive icon. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 21 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Patient Browser (Local Data): Information on the archive status of data In the Results list, information on the archive status is shown in the Study Archived, Series Archived, and Archive Status columns. If necessary, you can add these columns to the Results list. The following archive statuses are possible: • Not to be archived: Data will not be archived. • To be archived: Data will be archived during the next archiving interval, as defined in the Administration Portal. • Queued for archiving: Archiving is running, and the data is in the queue to be archived. • Archived: Data was successfully archived. • Archive failed: Data could not be archived. The status is indicated by icons. See the following table for examples. SIEMENS Healthineers O Patient Browser Results 0fimwas wa27 Series Instances Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 22 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Icon Archive status To be archived Not to be archived Queued for archiving Archived Error – Not archived You can review the archive status in the Instances view. Instances Inst ... Archive Status Hidden Instan ... SOP Class UID Acquisition Date an ... Image Type MR enh 28.01.2020 15:11:59 Original; Primary Siemens syngo Volume Set 28.01.2020 15:11:59 Derived; Secondar Patient Browser (Local Data): Edit or correct data Exercise: Explore the Correct data function In the Patient Browser (Local Data), you can correct or edit patient data, studies, series, and instances. You can only correct patient data if you have the necessary user rights. 1. Select a patient or study view in the Results list. Then select a study. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 23 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 2. In the Toolbar, select the Correct icon. -] View&GO Print Open Open with DICOM Import Export Correct Delete QIR 3. After selecting a patient from the Results list, select the Patient tab. Correction of Study ? x Aera_Abdomen (8/1/1966) 3 Patient Study Series (17) Instance (18) Caution: your changes will affect all studies of the patienti Title " Last Name Aera_Abdomen Edit First Name Other Patient Names Add Middle Name Remove Suffix Patient ID Germany_MAC Edit Issuer of Patient ID Other Patient IDS Add Remove Patient's Sex Male * Date of Birth 8/1/1966 È Ethnic Group Patient Comments Patient's Address 5 OK Cancel 4. Correct or add data. 5. Select OK to confirm your corrections. 6. The patient data is corrected, and the corrected flag is set. • Any assigned workflow is canceled. • The results and findings that were already saved may become invalid. Exercise: Correct data for multiple items To correct data for multiple series or instances in the Patient Browser (Local Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 24 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Data) even when certain values are not identical, proceed as follows: 1. Select Multiple Series. Or – – Select an area with the Edit icon. 2. Modify the data entry as needed. 3. Click OK. Correction of Study ? X Aera_Abdomen (8/1/1966) Patient Study Series (17) Instance (18) Body Part Examined Abdomen Protocol Name Edit Series Date and Time 8/13/2020 < Edit Operators' Name Add Remove Institution Name Kreiskliniken Reutlingen Institution Address OK Cancel Patient Browser (Local Data): Rearrange data SIEMENS Healthineers Patient Browser Local Data sich by Name, 10, Date, Description and Mogality (Ct)-1) More Filters Results (70 results, 11:54:15 AM) Patient Name Patient ID Date of Birth Study Date B ... Study Descripti ... Accession Nu ... Workflow Study Archived Corrected Aera Abdomen 2023.01.30-12. 1150/1045 1/30/2023:112. Abdomen Ab ... View&GO Dat ... 123456789 1/28/1991 1/28/2021 9:5 View&GO Dat .. Aera Abdomen Germany MAC 8/14/2020 8/14/2020 0 ..... Pathology Eld .... XABOA Aera_Abdomen Germany MAC 8/1/1966 8/1 3/2020 922 Cirrhosis Asci ... XA30A Aera Neck Austria MAC 3/1/1955 8/11/2020 2:26 CE_Dixon_SM ... XA30A Aera_Knee Germany MAC 0/1 1/2020 8/1 1/2020 12 . Meniscal tear .. XA30A Aura_Hoart Germany MAC 815/2020 8/4/2020 9:52 Pathology_He ... XA30A Aera Knee Germany MAC 7/31/2020 7/31/2020 11- Obese CE S ... XA30A Prisma Head Germany_MAC 7/24/1967 7/24/2020 12 ... Tumor 3D 2 ... XA30A Prisma_Cspine Germany MAC 215/1947 7122/2020 1125 Degenerative ... XASDA Prisma Head Germany MAC 3/2/1952 7172/2020 10 ... Stenosis MRF ... XA30A Aera Anke Germany_MAC 2/1/1940 7/16/2020 1: Sindesmosal XA30A Aera Le spine Austría MAC 71/12020 717/2020 6:2 .. Scoliotis SPS ... XAJOA Prisma_Pelvis Germany MAC 7:13/2001 7/1/2020 1:3. Frostate Seg. XA30A Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 25 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 In the Patient Browser (Local Data), you can move a study from one patient to another. Please note: Results and findings already saved may become invalid. You can rearrange patient data if you have the necessary user rights. Move Series AF ? X Do you really want to move the selected series of patient SiemensTest, GSP-Graphic - to study of patient Siemens Test, Spectroscopy? Yes No Exercise: Move a study to another patient You can move a study to another patient in the Patient view of the Results list. 1. Right‐click on the study and select Cut. 2. In the Results list, select a patient to assign the study to. 3. Select Paste to move the study. 4. The Move Studies dialog box opens. Select Yes to confirm the rearrangement of the series. The study is moved to the selected patient folder once confirmed. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 26 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Exercise: Assign a series to another patient 1. Right‐click on the series and select Cut. 2. In the Results list, select a patient to assign the series to. 3. Select Paste to move the series. 4. The Move Series dialog box opens. Select Yes to confirm the rearrangement of the series. The series is moved to the selected patient folder once confirmed. Patient Browser (Local Data): Merging patient data at studies level You can merge patient data by cutting patient data from one patient and pasting it to another patient. Please note: You need to have the necessary user rights. Exercise: Merging patient data 1. In the Patient view of the Results list, select a patient to merge with another patient. 2. Right‐click on the selected patient. 3. In the Results list, select Source Patient and select Cut. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 27 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 4. Select the target patient and select Paste. 5. The Merge Studies dialog box opens. Select Yes to confirm the merging of patient data. Merge Studies AF ? X Do you really want to merge the selected study of patient Aera_Knee to the study - of patient Aera_Knee? Data indicates that these are two different patients. Yes No 6. All studies for the source patient are moved to the target patient, and the source patient is deleted. The Corrected flag is set. Patient Browser (Local Data): Copy and paste at series level You can copy a series and paste it to a different study. Exercise: Copy and paste at series level 1. Go to the Patient view of the Results list. 2. Right‐click on the series of interest and select Copy. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 28 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Series Series Number Series Description Modality # Instances in ... Series Arch New Series Description MR To New Series Der TO 3 New Series Des Open TO 199 Phoenix ZIPRep View as Read-Only To Open with View as Read-Only with Set Archive state Correct Cut Copy Puste Delete Del Instances 3. Go to the Patient Browser Results list and select the target at the series level (different study). 4. Select Paste. Patient Browser (Local Data): Splitting series Split a series by selecting instances of the series and creating a new series containing the selected instances. Please note: Results and findings already saved may become invalid. You can only use the split function if you have the necessary user rights. Exercise: Splitting series 1. Go to Instances, and select List from the drop-down menu to create a new series. 2. Right‐click on the series of interest and choose Split to New Series from the context menu. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 29 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 View&GO Print Open Open with DICOM Import Export Correct Delete Series Series Number Series Description Modality # Instances + t2_haste cor MR t1_vibe_fs_tra_KM MR t1_vibe_fs_tra_KM MR t1_vibe_fs_tra_KM MR t1_vibe_fs_tra_KM MR 11 t1_vibe fs cor KM MR 12 t2_tseB_fs_tra_mbh MR 13 ep2d_diff_zoomit_b50_800_tra_free MR 14 ep2d_diff_zoomit_b50_800_tra_free_ADC MR 16 ep2d_diff_zoomit_b50_800_tra_free_CALC_BVAL MR 19 t1_vibe_fs_tra_spat KM MR 21 t1_vibe_fs_cor_spät KM MR 22 t1_vibe_fs tra KM MR t1_vibe_fs_cor_KM MR Instances Open View as Read-Only Open with View as Read-Only with 1/15 Set Archive state Correct Split to New Series Delete Del Display DICOM Header Delete Frames from Instance 3. Select Yes in the Split Series dialog box. Split Series AF ? X Do you really want to split the selected instances of patient Aera_Abdomen to a - new series? Yes No 4. The corrected flag is set. Patient Browser (Local Data): Delete data or frames You can delete data manually from the short-term storage (STS) if you have the necessary user rights. The automatic data deletion can be configured in the Administration Portal. Please note: The data is not protected from manual deletion. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 30 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Exercise: Delete data manually 1. Results list, Series list or Instances list: Select data that needs to be deleted. 2. Toolbar: Select the Delete icon. 3. Delete Permanently dialog box: Select Yes. You can use the Delete Frames from Instance to adapt the content of a series before archiving, for example to remove individual phases. Exercise: Deleting frames from Instance items Instances Ins ... A Acquisition Date an ... Image Comments Image Type Numb 1 3/51/2022 3:00:05 ... RR 1 Open View as Read-Only Open with View as Read-Only with Set Archive state Correct Split to New Series Delete Del Display DICOM Header Delete Frames from Instance 1. Click on the frame where you want to start. Then select one of the following icons: • Delete from Start • Delete Frames • Delete till End Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 31 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Delete Frames from Instance 2 X Instances Reference Series cine_segmented_lax_4Ch Instance / Frame 1/1 172 173 114 175 176 117 178 119 Delete Delete from Start Frame(*) End Confirm Cancel Patient Browser (Local Data): Protect data from deletion You can protect data from deletion, which prevents it from being deleted from the short-term storage (STS). Exercise: Enable the Delete Protection function 1. Go to the Results list. The protection state is shown in the Delete Protection column. Add the column if it is not visible. Please note: You need to have the necessary user rights to add the column to become visible. 2. Select a patient from the list to protect the data from deletion. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 32 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 3. Right‐click and select Set Delete Protection state > Protect from Deletion from the context menu. Set Mark state Set Delete Protection state Protect from Deletion Set Archive state Remove Delete Protection Exercise: Remove the delete protection 1. Go to the Results list. Information on the protection state is shown in the Delete Protection column. If the column is not visible, add the column. To be able to add the column, you need to have the necessary user rights. 2. Select the patient from the list that was protected to remove the delete protection. 3. Right‐click on the patient, and select Set Delete Protection state > Remove Delete Protection from the context menu. Set Mark state Set Deletra Delete Protection state Protect from Deletion Set Archive state Remove Delete Protection Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 33 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Patient Browser (Local Data): Display the DICOM header of an instance Exercise: Display the DICOM header 1. Go to Instances, and select List from the drop-down menu. 2. Right-click on an instance and select Display DICOM Header. Instances Ins ... A Acquisition Date an ... Image Comments Image Type Num 3/31/2022 3:00:05 ... RR 1 Open View as Read-Only Open with View as Read-Only with Set Archive state Correct Split to New Series Delete Del Display DICOM Header Delete Frames from Instance 3. The Display DICOM Header window opens and shows the DICOM header for the selected instance. Display DICOM Header Test (3/31/1944) Attributs Name Tag VR VM Nov Values (Length) Group 0002 Length (0002,0000) UL 108 File Meta Information Version (0002,0001) OB 00 01 (2) Media Storage SOP Class UID (0002.0002) UI "1.2 840.10008.5.1.4.1.1.4.1" (27) Media Storage SOP instance UID (0002,0003) UT "1 3.12.2.1107.5 2.19.999999.2022033115001276782800156" (53) Transfer Syntax UID (0002,0010) UI "1.2 840.10008.1 2.1" (19) Implementation Class UID (0002.0012) "1.3. 12.2 1107.52" (17) Implementation Version Name (0002,0013) SH "SYNGO_MR_XA30A" (14) Specific Character Set (0008.0005) CS "ISO_IR 100" (10) Image Type (0008.0008) CS "ORIGINAL" (8) "PRIMARY" (7) "CINE" (4) "NONE" (4) Instance Creation Date (0008,0012) DA "20220331" (8) Instance Creation Time (0008.0013) TM "150005 425000" (13) SOP Class UID (0008.00 16) UI "1.2 840.10008 5 1.4.1.1.4.1" (27) SOP Instance UID (0008,0018) "1 3.122.1107 5 2.19 999999 2022033115001276782800156 (53) Study Date (0008.0020) DA "20220331" (8) Series Date (0008.0021) DA "20220331"() Content Date (0008.0023) DA "20220331" (8) Acquisition Dato Time (0008.002A) DT "20220331150005 425000" (21) Study Time (0008,0030) TM "145943 200000" (13) Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 34 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Load a patient from the Patient Browser to MR View&GO Patient Browser Local Date+ jearch by Name, ID, Date, Description and Modality (Ctrl+F) Q More Filters Results (70 results, 12:11:07 PM) Series Patient Name Patient ID Date of Birth Study Date a ... . Study Descripti ... Accession Nu ... Workflow Study Archived Corrected Series Number Series Description Aera Abdomen 2023.01.30-1 ... 1/30/1945 1/30/2023 11 ... Abdomen Ab ... localizer bh View&GO Dat ... 123456789 1/28/1991 1/28/2021 9: .... View&GO Dat ... 2 12_haste_cor_mbh Aera_Abdomen Germany_MAC 8/14/2020 8/14/2020 8 -.... Pathology_Ela ... XA30A 3 12_haste_fs_tra_mbh Aera Abdomen Germany MAC 8/1/1966 8/1 3/2020 9 -... Cirrhosis Asci ... XA30A 4 11_vibe e-dixon tra bh pre Aera Neck Austria MAC 3/1/1955 8/11/2020 2: CE Dixon SM .... XA30A 11_vibe_e-dixon tra bh pre_in Exercise: Loading patient data to View&GO 1. Select a patient or study from the Patient Browser. 2. Then double‐click on the patient or study. Or – – Select the View&GO icon. Loading a patient to advanced post-processing workflows Please note: Licenses may be required to access advanced post-processing workflows. Exercise: Loading patient data to advanced post-processing workflows Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 35 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 1. Select a patient, study or series from the Patient Browser. 2. Right-click on the patient, study or series. 3. Select Open with, and then select an advanced workflow. Open Ctrl+D VD14 Open with · Favorites View as Read-Only with Suggested Batch Open MM AT Image Suite . Assign Workflow MR Angiography Cancel Worldlow MR Basic Search Patient with DICOM OUR MR Breast Add to Dema List MR Breast Biopsy Remove from Demo List MR BreVis Set Mark state Or – – Select Assign Workflow, and then select an advanced workflow. R Neurology Spain M Head Pr Tum. VET MR_Neuro3D Spain_M. Open Ctrl+O Cervical_P'T_D ... VEI MR_Cardiac_Analysis Romania Open with Head Sk_CSF ... VETI MR_Angiography Romania View as Read-Only with Head_Sk Ane .. VERS MA_Oncology Romania Head Sk Curr ... VE11 MK Oncology Batch Open Romar MR_ Prostate German Assign Workflow · Favorites MR Neurology Switzerta Cancel Worldlow · Suggested mMR_WE Spain_M Search Patient with DICOM QIR MMR_Head MR Basic MR_Cardiac_Analysis Add to Demno Lict Germa MA_BreVis Gem Remove from Demo List MR Breast MA Angiography MR Breast Biopsy German Set Mark state Vida_Hip Austria MR BreVis Set Delete Protection state Vida_Hand AUS! MR Cardiac Analysis " Lumina_Pelvis_miale Siem Set Archive state MR Neuro 30 ida_Elbow Austria Remove Correction state . More • MM RT Image Suite • MR Angiography • MR Basic • MR Breast • MR Breast Biopsy • MR BreVis • MR Cardiac Analysis • MR Neuro 3D • MR Neurology Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 36 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 • MR Oncology • MR Prostate • MR Spectro • MR Tissue 4D • MR Whole Spine Display workflow status Check MR View&GO or the post- processing workflow status from the Patient Browser (Local Data). To learn more, please follow the link below: Outside US MR View&GO I Display Workflow Status Video US MR View&GO I Display Workflow Status Video Exercise: Explore the post-processing workflow status Workflows open in different tabs. To check the status, proceed as follows: 1. Click on the Patient Browser icon. 2. The workflows currently in use are displayed in the Workflow column. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 37 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 3. The data opened in MR View&GO is displayed in the View&GO status column. Results 2025.11.261 1875-1958 012247 Or – – From Job View, select Workflows. The complete list of data opened in workflows is shown. Job View Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 38 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 MR View&GO: Viewing and displays MR View&GO is the viewing and post‐ processing application for all types of basic operations required by the technologists to view, manipulate, and post-process images during or after scanning. Acquired images are automatically loaded into MR View&GO. The following features can be used: • Zoom, Pan, Rotate, Windowing, ColorLUTS • 2D, 3D (MPR, MIP, MinIP, VRT), 4D • Measurements (such as Line, Circle, Angle, ROI), Position Display • Image Calculations (such as Subtraction, ADC/b‐Value, Distortion Correction, ImageFilter) • TimeCurve, Composing, Ranges (parallel, radial, radial sliced, curved) • Send and Archive to DICOM nodes To learn more about ADC value calculation, please follow the link below: Outside US Calculation Video US Calculation Video Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 39 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 To learn more about the printing function, please follow the link below: Outside US Print Video US Print Video MR View&GO: Overview 7 SIEMENS Athingers 1 ? 2 6 Lese 3 5 (1) Access bar (2) Series panel (3) Image area (4) Favorite tools area (5) Controls/icons (6) Case navigator (7) Tabs to open or close Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 40 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 MR View&GO: Viewing The number of open patient tabs is limited to three patients (plus one tab for the current patient). The tab for the current patient is always the left-hand tab identified with the scanner symbol. If a new patient is registered and the examination is started, the far-right patient tab will close automatically, and created results will be stored in the local database. Please note: All data is saved, but not archived. When the maximum number of patient tabs is open and you want to load another patient from the Patient Browser, a warning message prompts you to close at least one patient tab. The Scanner symbol indicates the current patient being scanned. O Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 41 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Select and define layouts A layout determines the number, size, order of segments, and content displayed in segments. Exercise: Explore the Layout Gallery 1. Load patient data to MR View&GO. The number of predefined layouts is shown. 2. Show or hide predefined layouts by selecting the MR View&GO tab. 3. Select the Layout Gallery icon. All available layouts for the current step are displayed. 4. To change a layout, select a layout. Once selected, the segments in the image area change. MR View&GO X Layout Gallery X 2 MR View&GO 4 Public Layouts Seack 3x2 Stack 2x2 Stack 5x4 Stack 1x1 Stack 211 Stack 2x2 Stack 2x2 Stack 3x1 Stack 3<2 Stack 3x3 Stack 4x2 Stack 4x3 Stack 4x3 Stack 4x4 2TF ZTP 21P Stack 5x3 Stack 3a4 40 Expand 4D Expand Stripe 3x2 Stripe bx3 3 Favorite Tools Image display: Synchronize image segments Several segments can be synchronized. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 42 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Exercise: Image synchronization 1. Load patient data into MR View&GO and select an image segment. 2. Depress the Ctrl key and select the segments you want to synchronize. To select all segments, select Ctrl + A. 3. Left-click on any segment to cancel the synchronization. 4. Double-click on an image to enlarge the display of a selected image to a full segment (1x1 layout). 5. Double-click on the enlarged image again to revert the enlarged image to the previous layout. Navigating through 4D datasets 4D datasets consist of, for example, multiple phases, b‐values, or multiple echoes. Exercise: Explore 4D data sets 1. Select a data set which contains 4D phases, such as brain examination – diffusion images. 2. Navigate through the 4D datasets using the mouse or keyboard. • Mouse: Depress the right mouse button and move the mouse left or right. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 43 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 • Keyboard: Use the symbol keys on the numeric keypad or press the left or right arrow key to display the previous or next dataset. 4D 4D. 7 8 For navigating the 4D datasets, 4D Collapsed or 4D Expanded views are available. • 4D Collapsed: You see all phases in one segment. • 4D Expanded: You see individual phases in separate segments. FAR SiemensTest 10/1/1970, 0, 50Y CURRENT 10/1/2020 4D 2 MAI FR N125 ROF CURRENT CURRENT 10/1/2020 10/1/2020 4D 0 4D >>> 5:08:31 PM 2 IMA 1 FRM 1/25 5:08:31 PM 2 IMA 1 FRM 1/25 Collapsed Expanded 4D datasets: Movie tool Navigate through 4D datasets with the Movie tool. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 44 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Exercise: Explore the Movie tool 1. To start a movie, select Movie from the upper left corner menu or press the spacebar. Several datasets are available in one segment. Zoom/Pan Windowing Rotate Scroll Movie 30 Reference Point Save as Series Fit to Segment Flip Horizontal 2. In the Movie control panel, select Time or Space from the list to navigate through the datasets automatically. 22 25 Time no skip 60 FIS Space Plect animation mode Time • Select Time to navigate through phases of one slice. • Select Space to navigate through all slices within one phase. The Movie control panel is used in particular for GRASP‐VIBE visualization and CINE (such as Phases). Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 45 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Test 3/31/2022 latestPhase_10 of 25 SPC 5 fps MR View&GO: Overview of the Series panel Exercise: Explore the Series panel 1 2 3 4 5 Series X ER Add Study Sand and Archive Later 01 MR, 11/18/2015 Head Sk Current Current MR. 11/12/2015 Head_Sk_Prior 11_tirm_sig_dark- 12_blade_tra_p2 fluid_p3 [20] [21] 12_tin_cor_dark nuld_3mm [22] [1_se_tra [29] 6 t2_tirm_tra_dark Buid_p2 [30] resolve_3:can ... 1. Select the Series panel and select the Expand & Collapse icon. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 46 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 2. Select the Change View icon. • Select the Thumbnails view to preview images. • Select the List view to get a text overview of data. Series Il: Thumbnails Add Study Send and Archive List 3. Images are listed according to data attributes. 4. This is the Add Study icon. 5. This is the Send and Archive icon. 6 t2_tirm_tra_dark resolve_3scan ... fluid_p2 [30] B-Value_01 [b0] B-Value_02 [61000] resolve_3scan_trace t1_mprage_tra_p2_i _tra_192_p2_ADC .. so [34] t1_co_tra_por 7 Results MR ew&GO [1015] 6. Here you can expand or collapse the series stack. 7. This is the Results icon. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 47 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Series panel The overview of series loaded for a study shows all currently loaded image data. • Load other series, time points, or results to display in image segments. • Series number: Displayed by series name on list. • You can drag the # column before or after the Series Name column. Series × Add Study Send and Archive # Series Name Current MR, 10/29/2020 Comp_DR-Gain_DR-Sharp_HN20ch 27 AAspine_scout_CPR 27 AAspine_scout_CPR_#1 28 AAspine_scout 20 AAspine_scout_MPR_sag Series X 15 Study Send and Archive Series Name # A Current _ MR, 10/29/2020 Comp_DR-Gain_DR-Sharp_HN20ch AAspine_scout_CPR 27 AAspine_scout_CPR_#1 27 AAspine_scout 28 > AAspine_scout_MPR_sag Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 48 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Series panel: Organization and visualization of data The Series panel provides two views: • List view: Gives an overview of the data sorted into data groups. • Thumbnails view: Gives a preview of the images. Depending on the layout, not all available data might be displayed in the image area. Data that is displayed in the image area is indicated by bold type in the Series panel. You can use the Series panel to select further images to be displayed in the image area. The Series panel also offers you an option to add further studies to the currently loaded one, for example prior studies. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 49 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 List view example Series × Add Study Send and Archive Series Name Later 01 MR, 11/18/2015 Head_Sk_Current Current 1 MR, 11/12/2015 Head_Sk_Prior 20 t1_tirm_sag_dark-fluid_p3 21 t2 blade tra p2 2 22 t2_tirm_cor_dark-fluid_3mm 29 t1_se tra 30 t2_tirm_tra_dark-fluid_p2 3 31 resolve_3scan_trace_tra_192_p ... B-Value_01 [bo] B-Value_02 [b1000] (1) Blue on black: At least one item of the group is currently displayed in a segment. (2) Blue bold type on a black background: An item or a whole group is displayed in segments. (3) Blue type on a gray background: Current selected item Exercise: Explore the Series panel and toggle display elements 1. Select X to close and hide the Series panel. 2. Click the Series tab on the left side of the MR View&GO to show the Series panel. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 50 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 SIEMENS O - 3. Press the F11 key to hide or show the Series panel, Viewing panel and Favorite Tools. 4. If the Series panel is hidden, only the image area is displayed. Series panel: Add Study icon With the Add Study icon, you can load additional studies to the patient already loaded. To do that, search for prior or related studies in a local database or DICOM nodes. Please note: When more studies from a patient are loaded in the Series panel, the current study marks the date in green. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 51 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 AFL Series MR_Onco_Brain_V_02 MR Bremen Mite MR_Onco_Brain_V_02 MIR Bremen Mitte MR_Onco_Brain_V_02 H407 "1/1/1 900, F. 109Y Cerio HO7 "10/1900. F. 109Y verlo HAT MR BIZ VR 817 "1/1/1900. F. 109Y 4/27/2009 4/27/2009 MR 817 HFS 4/27/2009 HFS CLPH 12_Brm_darlefuid_ta_p2 12_tse_tra_p2 .LPH latest latest 6:03:53 PM 14 PM4A 1 6:05:05 PM 15IMAT RAH TR 8.6 TR 5000 0 TE 4.0 TP O TR 9000 0 SP 0.0 TE 94.0 TP O SP HP2.4 TE 96.0 TA 55 38 SP H99 8 TA 03 98*3 W 250-250 TA 54.34"2 FOV 194.230 iFav 195-230 BW 320.0 230-256 BW 287 0 194 2565 BWY 220.0 MINDNORM P2 MINDINORMEN Tra>Corps)- Bap(-2) 02 MONDINORMFM 272º3205 ra>Cor(6)>Sag(-2) AZ Zoom 0. 84 ATARIFS Zoom 0 99 Zoom 0 41 CHEANER W C 424 200 d HEAHEP W d HEAHEP W 1732 1201/ 20 tr2dt_16/150 180241_18/150 911 ............ obablastoma, post surgery Globla stoma, post surpery Gachiantoma: post surgery AFL AFL AFL MR_Onco_Braim_V_02 MR Bremen Mite MR_Onco_Brain_V_02 MR Bremen Mate MR_Onco_Brain_V_02 IR Bremen Mipe H07 "1/1/1 900, F. 109Y Verio verlo MR 017 "10/1900, F. 103Y HOT MR 017 *1/1/1300. F. 109Y 4/27/2009 MR B! HFS 4/27/2009 HFS 4/27/2009 .............. ep2d_diff_3scan_brace_Ya_02 .LPH ep2d_del_3scan_hace_tra_p2_cft .LPH 12_42d_a_hemo latest0-Value_01 Latest latest 6:10:47 PM 16 IMA 10 RAH 429/2008 11:01 AM RAH RAH MR, Head_prior 2D SL 5.0 20 SPC SPC SPC TR 4900.0 TR 4900.0 R TP O TR 600 0 TP O TE 94 0 TP O SP H45.8 TE 94.0 TA OD 05 SP H93.8 TE 19.9 SP 199 8 FOV 230-230 TA. 00 05 BWV 1187.0 FOV 230"230 TA 01 :40 BW 1187.0 EN 199 0 ·FoV 179 220 166-2584 D2 DFFITRACEWINDFM 130p*162 p2 DIFFITRACEWINDIFM 130p*162 Tra-Cercoy-Sac(-2) MIND NORMEN Tra>Cor(b)> Sag(-2) A1/PFPIFS Zoom 2.65 Zoom 2 65 Zoom 1.06 CHEAHEP W 1716 AV/PFPAS W 1716 ep_bor90 756 CHEA HEP ep_60/90 755 CHEAHEP,NE2 12611/ 20 Olhablastoma, Cost surgery Oboblastoma, post surgery Exercise: Adding a study 1. Go to the Series panel. 2. Select the Add Study icon. The Add Study dialog box opens. 3. Click the Search icon. The results are displayed. 4. Select a study or series. 5. Click the Load Data icon to load data into the Series panel. Add Study ? X Source Selection Search Filters 3 Local *Head* Search Load Data Results (4 results, 4:47:06 PM) Series 5 Patient Name Patient ID Date of Birth Series Number Series Descripti ... Modality Vida Head Siemens_MAC 1/1/1962 AAhead_scout MR Vida Head Siemens_MAC 1/1/1969 AAhead scou ... MR Sola Head Siemens_MAC 2/1/1900 AAhead scoU ... MR mMR Head Australia_MAC 1/1/2014 AAhead_scou ... MR AWN 5 t1_qtse_dark -... MR t1_qtse_dark -... MR 7 t1_qtse_dark -... MR 8 t1_qtse_dark -... MR t2_qtse_tra_p3 MR 10 t1_qtse_dark -... MR 11 t1_qtse_dark -... MR 12 t2_qtse_tra_p ... MR 13 t2_qtse_tra_p ... MR 14 t2_qtse_tra_p ... MR 15 t2_qtse_tra_p ... MR 16 t2_qtse_tra_p ... MR 17 t2_qtse_tra_p ... MR 18 12 atse dark- MR Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 52 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Series panel: Add images from a different study You can load additional images from different studies to the patient already loaded. To do that, drag and drop the images from another study into a series. To learn more, please follow the link below: Outside US MR View&GO | Add Data to a Running Application Video US MR View&GO I Add Data to a Running Application Video Exercise: Adding items with drag and drop 1. Go to the Patient Browser. 2. Select a study from the Results list or images from a Series list. 3. Drag the selected data into the preferred MR View&GO tab. 4. In the Add data dialog, click Yes to confirm you want to add the data. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 53 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 SIEMENS Healthineers Patient Browser Q Results (19 859:39 AM Series Duals of Bath 1334114 EE 012345 Instances Distributing results: Send and Archive function To learn more, please follow the link below: Outside US Distribution Video US Distribution Video Overview of all acquired series and results of the current study Exercise: Explore the current study items to get a general overview 1. When viewing a patient in the MR View&GO tab, click on the Send and Archive icon to show the series to be sent in a pop-up window. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 54 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Series X Add Study | Send and Archive 2. Check Archive Settings and Send Status for each acquired series. The Default Node is the archive defined where all series are sent, displayed in the first column, for example syngo.Plaza. Left-click on the Archive checkboxes to select or deselect the Series to be archived or to enable further DICOM nodes to be selected for archiving. Overview of the Send and Archive dialog box Send and Archive 1 5 2 w Preview Num .... Preview Description # Images PACS DUMMY-NO ... Thumbnail = List cine_segmented_lax_3 ... 1/25 cine_segmented_lax_4 ... 1/ 25 4 cine segmented lax 2 ... 1/25 AAhead scout MPR seg 6 . 5 AAhead scout_MPR_tre AAhead_scout_MPR_tra 99 PhoenixZIPReport 7 Send 8 (1) View Selection: Switches between views in the display area. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 55 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 • Preview: Preview all available series by scrolling through each series. • Thumbnail: This is a preview of all available series. The first image of each series is displayed as a thumbnail image. • List: In this view, no preview is available. The series is identified by the series description. (2) Archive location: Check available archives – DICOM node targets. (3) At least one DICOM node must be configured. (4) Each remote DICOM node is visible. (5) Preview column: All the available series are visible. (6) The icons indicate the sent status. (7) Description columns: Displays series description. (8) Check box: Indicates that the series is selected to be sent to a specified DICOM node. • When the box is checked, selected data is archived. • When the box is not checked, data is not archived. Please note: All series in the default archive column are selected automatically. Clear the checkboxes for individual series that should not be sent to the selected archive. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 56 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 X # Images PACS DUMMY-NO ... gmented_lax_3 ... 1/25 [gmented_lax_4 ... 1/ 25 (9) Send button: Sends selected series to a specified DICOM node. (10) Close button: Closes the distribution window. Exercise: Copy a selection to another DICOM node To copy a selection made for one DICOM node to another node, proceed as follows: 1. Right‐click on the DICOM node column header. 2. Select Copy Selection to and select DICOM node. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 57 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Renaming a description before sending it Exercise: Rename a series before sending it You can rename a scanned series and a results series description from the Send and Archive dialog just before sending it. 1. In the Description column, right-click on the series name. 2. Click Rename. 3. Rename the series and press Enter. Please note: The name is modified both in the Send and Archive dialog and in the MR View&GO Series panel. Saving and sending archiving results Clicking on the Send button in the Send and Archive window sends the selected images to the specified DICOM nodes. Send Close Please note: Check whether the data was sent successfully by opening the study again and checking the icon status Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 58 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 in the Send and Archive dialog. The export status is also visible. Series sent successfully Error occurred when series sent Sending in progress Save and archive results Exercise: Explore the save and archive results 1. Exit MR View&GO. The workflow closes, and all unsaved results are saved in the short-term storage (STS). Results are sent to selected DICOM nodes. 2. Click the Save and Send icon. V The workflow is closed. The status of the workflow is set to Complete in the Results list of the Patient Browser. 3. Select the Save and Pause icon. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 59 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 The workflow is closed. In the Results list of the Patient Browser, the workflow is displayed as saved, but the data is not archived. 4. Close the patient folder by selecting X in the upper right corner of the Patient tab. SIEMENS Healthineers O. MR_Oncology X * 1/1/1964 F Romania_MAC Lumina_C-spine MR View&GO The workflow is closed. Please note: If you select the X icon, no post-processed data will be saved. Archiving results The synchronization of the archive status between a distribution step and the Patient Browser is triggered by the following functions: • Send • Save and Send • Save and Pause Please note: If you uncheck a series in a distribution step, and if you then press either Send, Save and Send or Save and Pause, the status is transferred to the Patient Browser as Not to be archived. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 60 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Send and Archive Num. Preview Description # Images E. PACS DUMMY-NO ... cine_segmented_lax_3 ... 1/25 cine_segmented_lax_4 ... 1125 cine_segmented_lax_2 .... 1/25 AAhead_scout_MPR_sag AAhead_scout_MPR_tra AAhead_scout_MPR_tra PhoenixZIPReport Send Close Series Series Number Series Description Modality # Instance Series Archived Cine_segmented lax 3Ch MR cine_segmented lax 4Ch MR cine_segmented lax_2Ch MR 199 PhoenixZIPReport SR AAhead scout MPR_sag MR AAhead_scout_MPR_tra MR 6 AAhead scout MPR tra MR Patient Browser: Archive status icons The following archive statuses can be displayed: • To be archived • Not archived • Queued for archiving • Archived • Archive failed Series Series Number Series Description Series Archived Exported cine_segmented_lax_3Ch To be archive 2 cine_segmented_lax_4Ch Not archived 3 cine_segmented_lax_2Ch Queued for archiving 4 cine_segmented_sax Archived 99 PhoenixZIPReport Archive failed Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 61 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Corner menus and context menu Corner menus Image preparation and optimization tools are available in the corner of each segment. However, each corner menu is different and depends on the loaded image in the segment and the active workflow. HRA MR_Oncology SPITALUL CLINIC SANADOR Romania_MAC Ref.: Congress *1/1/1964, F. 51Y Skyra CURRENT MR E11 11/13/2015 HFS +LPH 11_tirm_sag_dark-fluid_09 latest #VE11 STUDY ID 2aaaa0918 20 IMA 23 AL TI 900.0 TR 2000.0 TE 9.0 TP F13 TA01:02*3 SP L1.0 BW 260.0 FoV 240*240 p3 M/NORM/DIS2D 256.320 Sag>Tra(-3)>Cor(-1) ALAR Zoom 1.53 HC1-7;NC1,2 860 "tir2d1_4/ 150 63 Working with corner menus To learn more, please follow the link below: US MR View&GO – Corner Menus Job Aid Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 62 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Exercise: Explore the corner menus 1. Left-click on a watermark in the corner of the segment. Or – – Hover with the mouse cursor over a menu item to open the available tool options. The available tools depend on the image or series displayed and the current active workflow steps. 2. Click on an individual tool from the list to activate it. Or – – Hover the mouse cursor over a menu item to open the available tool options. Exercise: Adjust the tool settings 1. To change the tool properties, point to a tool and select the Settings icon. Please note: Not all tools have a settings icon to allow adjustments or enable displayed values to be set. Additionally, once you have changed the tool settings, they apply to all future interactions. 2. Press the Esc key to deactivate or close the current tool selected. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 63 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Upper left corner menu: Image preparation tools Zoom Pan HRA -( Windowing SPITALUL CLINIC SANADOR Ref: Congress Rotate Skyra MR E11 Scrol HFS -LPH EM Movie 3D Reference Point Ranges Save as Series Fit to Segment E TP F13 KA Flip Horizontal SPL1.0 BVY 260.0 FoV 240-240 p3 M/NORM/DIS2D 256.320 Bag> Tra(-3)>Cor(-1) ALAR Zoom 1.53 HC1-7;NC1.2 "Wr201_4/150 463 Exercise: Explore the image preparation tools 1. Select Brain examination and load the data into the MR View&GO workflow. 2. Select Zoom/Pan. Now, the left mouse action depends on the position of the mouse pointer in the frame. In the central area of the image frame you can pan. Closer to the edge of the frame, you can zoom the image. The mouse pointer visualization changes accordingly. 3. Perform Windowing: In an image frame, press and hold the middle mouse button and move the mouse to adjust the image brightness and contrast. This will change, for example, the Width/Center values. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 64 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 4. Rotate the image: Use the left mouse button to rotate an image or displayed volume. 5. Scroll: Use the left mouse button or keyboard to scroll through images. 6. 3D Reference Point: Right-click in the image and select 3D Reference Point. Now you can navigate to the same patient coordinates in a different series or series view. 7. Ranges: Reformats volumetric data as a series of images. Use this function to create other anatomical planes or change the visualization. You can create parallel ranges, radial sliced ranges, radial ranges, or curved ranges. 8. Save as Series: After modifying a series, save the images as a new result series. 9. Fit to Segment: Resizes the images in a selected segment to its original size and location (to remove, for example, Zoom/Pan). 10. Fit to Acquisition Size: Displays selected images in their original (acquired) resolution. 11. Flip Images: Flips the displayed images horizontally or vertically. You can do the following: • Flip Horizontal • Flip Vertical • Rotate 90 Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 65 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Lower left corner menu: Visualization functions and display types HRP MR_Neurology Ruber Madrid Spain_MAC *1/1/1 960, M. 56Y Ref: Congress Prisma CURRENT MR E11 2/19/2016 HFS .LPH 11_space_sag_iso Cinematic VRT VRTALIP VRT Mosaic DIR MinIP Thin TP SP R3.0 MIP FoV 240*240 256*256 MPR/MPR Sag>Tra(-4) Zoom 1.91 535 MPR 207 2D Exercise: Explore the image types in the visualization corner menu Cinematic VRT is a volume rendering technique that provides a photorealistic visualization of the human body. 1. Select a 3D angiography dataset and select Volume Rendering Technique (VRT). This function renders and displays different tissue types from CT and MR images in a semi‐transparent 3D view: • VRT • VRT Thin Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 66 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 2. Select a 3D angiography dataset and select MIP. The MIP image is reconstructed, and the entire volume is checked which will result in one projection. The following options are available: • MIP Thin: Slab volume is used to calculate the projection. • MinIP Thin: Creates a minimum intensity projection from a 3D series. • MinIP Thin Properties 3. Select a 3D volume dataset and select MPR to combine loaded images in a volume used for calculating cuts in any orientation. You can select the following here: • MPR Thick: Reconstructs a 3D volume dataset using an individually defined slice thickness which is usually thicker than the original image. • MPR Thick Properties Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 67 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Upper right corner menu: Measurement and marking tools HRP Edit Comment MR_Neurology Distance Line Spain_MAC "1/1/1 960, M, 56Y ROI Circle 2/19/2016 Pixel Lens 11_space_sag_iso latest Arrow # VE11 STUDY ID 2aaaa0916 Marker 8:41:56 PM 6 IMA 94 Angle Text T AH Spine/Rib Label 2D SL Angle on Stack TR 700.0 DIF TP O TE 11.0 SP R3.9 TA 05:30 FoV 240 240 BWV 630.0 250*256 p4 MIND/NORM Sag> Tra(-4) A2 Zoom 2.32 HEA;HEP 612 "spcR_38ns / var C 272 Exercise: Explore the measurement and marking tools 1. Distance: Measures the length in an image. 2. Distance Polyline: Used to measure the length of a vessel. 3. ROI (region of interest): • ROI Circle: Evaluates statistical values for a circular or elliptical region to measure, for example, the diameter of a vessel. • ROI Freehand: Mark a specific irregular region. • ROI Auto Contour: Define contours automatically. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 68 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 • ROI Polygonal: Mark a specific irregular region. • ROI Properties 4. Pixel Lens: Determines the pixel value at a current position of a pixel or a voxel. 5. Arrow: Mark specific areas in an image by drawing annotation arrows. 6. Marker: Mark specific areas in an image and label. 7. Angle: Measure angles between two distance lines. 8. Text: Label specific areas in an image and insert an image text. 9. Edit Comment: Change the image comments in the original images. 10. Spine/Rib Label: Depending on the selected dataset, only Spine Labeling or Spine and Rib Labeling is available. Angle on Stack You can use this tool only on images with the same orientation. The tool cannot be used in curved views. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 69 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 When you use this tool, ensure that the images are displayed in a stack layout. Additionally, make sure that 2D, MPR, MPR Thick, MIP Thin, MinIP Thin, or MPR/MPR images are available. Exercise: Angle on Stack 1. Load patient data into MR View&Go and observe whether the images are displayed in a stack layout. 2. Select an image segment and choose Angle on Stack from the upper right corner menu. Now the mouse pointer changes its shape. AHR Edit Comment Ref. Distance Line ROI Circle O Pixel Lens Arrow Marker Angle Text T Spine/Rib Label Angle on Stack 3. Scroll to the required image slice and press down the left mouse button to draw the first line. 4. Scroll to another slice and draw the second line. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 70 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Now, the angle between the two lines is calculated. The result of the measurement is displayed next to the angle. Angle: 43 deg Lower right corner menu: Windowing settings and modality‐specific presets. HRP MR_Neurology Ruber Madrid Spain_MAC Ref: Congress 1/1/1 960, M, 56Y Prisma 2/19/2016 MR E11 HFS 11_space_sag_iso -LPH latest #VE11 STUDY ID 2aaaa0916 8:41:56 PM 6 IMA 94 AH 2D Position Display Single SL 0.9 Correction Tools % ImageFilter Smooth TR 700,0 TE 11.0 Analysis Tools TA 05:30 BWV 630.0 Auto Windowing p4 MINDINORM A2 MR Presets HEA;HEP "spcR_38ns / var MR Color LUT Reset Windowing Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 71 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Exercise: Explore the Windowing settings and modality-specific presets 1. Select Position Display to display lines where images were acquired. You can select the following here: • Position Display Series • Position Display Selection 2. Click on Correction Tools to correct motion and geometric distortions. You can select the following here: • Motion Correction (Elastic): Corrects soft tissue motions in an imaging volume. At least two phases are required to perform this function. • Distortion Correction: Geometric distortions may occur at the edge of images when using a large field of view (FoV) or off‐center slices. 3. Apply Image Filter Smooth to post- process blurred images or images with strong noise. 4. Click on Analysis Tools to evaluate dynamic processes and images by using arithmetic and statistical functions. You can select the following here: • Subtraction: Perform this function on images, series, or 4D datasets to subtract different time phases. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 72 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 • Addition: Adds grayscale values of images or adds a constant. • Multiplication: Rescales the grayscale value of images by multiplying a set of images or series by a constant value. • Division: Divide images or a set of series by a constant value. You can also divide series by series, or divide a series by one image. • Apparent Diffusion Coefficient (ADC): Determines the mobility of molecules in certain tissue types. • Arithmetic Mean: Calculates the mean value of the grayscale to average large intensity differences in images. 5. Apply Auto Windowing to calculate window width and center values automatically. 6. Select MR Presets to review MR presets with predefined window values. 7. Use the MR Color LUT (look‐up table) to define a sequence of colors. 8. Change windowing and select Reset Windowing. Now the windowing values are restored to when data was initially loaded to View&GO. Use this function when applied window values are not as expected. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 73 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Context menu In the context menu, you can access functions corresponding to the current work situation. HRA MR_Oncology SPITALUL CLINIC SANADOR Romania_MAC *1/1/1964, F. 51Y Ref.: Congress T Text Skyra CURRENT MR E11 11/13/2015 Clip Box HFS t1_tirm_sag_dark-fluit ·LPH latest Fit to Segment #VE11 STUDY ID 2aaaa0918 O ROI Circle 20 IMA 23 AL 30 Reference Point Distance Line TI 900.0 TR 2000.0 -i- Marker TE 9.0 TP F13 TA 01:02*3 BW 260.0 - ADC & b-value SP L1.0 FoV 240*240 p3 M/NORM/DIS2D 256.320 [I] Exclude Time Point Sag>Tra(-3)>Cor(-1) AMAR Zoom 1.53 HC1-7;NC1,2 Insert and Propaga! 1176 "tir2d1_4/ 150 586 3D Show in 3D P Exercise: Configure the context menu You can configure the context menu to quickly access favorite tools in the corner menu. 1. Open the context menu. 2. Select an image segment. Right‐click in the image segment to open the context menu. 3. Add a tool to the context menu. 4. Select a watermark in any corner segment. 5. Select a tool. Right‐click on the tool and select Send to Context Menu. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 74 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 6. To rearrange tools in the context menu, depress the left mouse button on any tool. Then, drag the tool to a new position in the context menu. 7. To remove a tool from the context menu, select a tool in the context menu. Then, depress the left mouse button and drag the tool out of the context menu. Copy and pasting evaluation details of measurements You can copy and paste the evaluation details of measurements to any reporting software, for example to the Notepad. Exercise: Copy and paste evaluation details 1. To create a measurement, select an image segment and right-click in the image segment. Select Distance Line from the context menu. 2. Select the Distance Line created. Right-click on it, and choose Copy Measurement from the context menu. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 75 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 2.04 cm Delete Measurement Copy Measurement Copy Text 3. Navigate to the reporting software. Right-click on it, and choose Paste from the context menu. Or – – Navigate to the reporting software, and choose the required cursor position. Then, press Ctrl + V on your keyboard. To learn more, please follow the link below: Outside US MR View&GO | Add Data to a Running Application Video US MR View&GO | Add Data to a Running Application Video Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 76 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Favorite Tools area Exercise: Explore the Favorite Tools area 1. Load patient data into MR View&GO. 2. In the Favorite Tools area, select + to open the Tool Gallery. 3. All available tools are sorted by categories. Review them and try various categories: • Basic Interactions • Display Types • Measurements • Annotations • Ranges • Image Visualization • Windowing • 3D Editing • Print & Export • MR Tools • MR Calculation • Post-processing Only active tools can be applied to a current selected segment. Please note: Some of these tools can also be found in the corner menus. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 77 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 MR View&GO X MR View&GO Favorite Tools Series Printing Favorite Tools * = + Exercise: Explore the Favorite Tools Gallery 1. Select the + icon to open the Tool Gallery. Favorite Tools X -- + Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 78 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 2. Select the scroll bar to access additional tools. Tool Gallery X Basic Interactions 4 Zoom/Pan Scroll Rotate Movie Visual Magnifier Alignment Display Types 20 MPR MPRIMPR MIP MinIP Thin VRT Cinemat. VRT Gallery Measurements + 0 Distance Angle Angle on Pixel Lens FOI Circle VOI Sphere Line Stack Annotations T D Marker Arrow Text Edit Comment Ranges Parallel Radia Radia Curved Spine Vascular Ranges Ranges Slice ... Ranges Ranges Rangos Image Visualization E E Fit to Fit to Acq. Hide Hide Color Hide Lines | Full Text Lock Ref. 3D Raf. Enlarge Flip Flip Flip Rotate CW Shutters Segment Size Graphics Bars Lines Point Segments Horizontal Horizontal Vertical Onfor Online training for the Favorite Tools area and context menu To learn more on how to configure the Favorite Tools area and the context menu, please follow the link below: Outside US Configuration Video US Configuration Video Magnifier You can magnify a section of an image to obtain a closer view. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 79 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Exercise: Explore the Magnifier function 1. Select patient data and load it into MR View&Go. The images are displayed in the segments. 2. Select an image segment and click the Magnifier icon in the Tool Gallery. Now the the mouse pointer changes its shape. Tool Gallery Basic Interactions Zoom/Pan Hotate Movie Display Types 20 MiNF Thin VRT Measurements O Angle Angle on Pizel Lees ROI Orde VOSpress Stack Annotations T D Marker AHOW Text Comment Ranges Porale Ranges Ranges Curved Ranges Lange Image Visualization Fit to Ab. Hide Hide Color Hde Lines | Full Text | Luckcker 3. Click on the image and drag the mouse to select a section on the image. The selected area on the image is magnified. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 80 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Please note: Image texts, labels, and annotations are not displayed in the magnified image section. 4. Click and drag the magnified image section to reposition it. 5. To close the magnified image, select the Magnifier icon again. Or – – Double-click on the magnified image section to place the layout in a 1x1 format. Double-click on it again to return to the previous layout. 6. If one or more image sections are magnified, press the Esc key to close all magnified image sections. Image Sorting tool The Image Sorting tool helps you to arrange images for reading. Within the Image Sorting tool, you are able to do the following: Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 81 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 • Sort images according to different criteria and order. • Manipulate images at image level (Flip Horizontal, Flip Vertical, Rotate CW90°, Rotate CCW90°). • Remove images. 2-12_arm surk duid_tua 3 -12_Urm_dark fluid are 4-12_Um_dure flud_De 5 -2_in_dark bald_tua 6-12_im_dark luid_tra P2 p2 - 7-12_im_Sark Hura_una 8-12_in_dark fluid_ara p2 9 at2_tem_dark-fiard_tra 11 .12_timm_dark-fluit_ 12 . 12_firm_dark-flirt_ 14 -12_arm state-full_ 15-12_in_core-Ant Ira_p2 74_p2 16 . 12_firm_dark-nuit 17 - 12 1km dark-1uid tra_p2 18 - 12 tirim cork-fluid 19 -12 drm dark-fluid 20 - 12_ dirm_dark-fluid 21 -:2 tirm dark tuid tra_p2 23 - 12 trim cark-fluid 24 - 12 tim derk-fluid 0/24 Image Sorting Senza L'escription 2 1im durk fluid bie p2 PACS Santing Criteria Sorting Order Irnugge Munipulution Inviude / Remove Imove(s) Chrono Numbered logical Triarpen Poransing Descend From Passt All Crcete Exercise: Explore the Image Sorting tool 1. Select a patient and study to be loaded into MR View&GO. 2. Select any of the segments that you want to load into the Image Sorting tool. Please note: • If a segment contains exactly one series, this series is loaded into the Image Sorting tool. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 82 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 • If a segment contains more than one series, all these series will be loaded into Image Sorting. • If a segment contains 4D data, the Image Sorting icon appears dimmed. Expand the data in this segment before loading the dataset into Image Sorting. 3. In the Favorite Tools panel, click the Image Sorting icon. Image Sorting Now, the images of the selected series are shown as thumbnails in the Image Sorting tool. 4. Under Sorting Criteria, select one of the options, such as Anatomical. Sorting Criteria # -.. + Anatom- As Numbered Chrono- ical logical Triggered • Anatomical: Sort by image position and orientation. • As Numbered: Sort by image number. • Chronological: Sort by time of acquisition. • Triggered: Sort by trigger time. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 83 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Please note: Here are the use cases for triggered sorting: o Multi-slice/single-phase measurements or multi- slice/multi-phase measurements when a slice package is anatomically viewed at a defined trigger time o Perfusion and diffusion of multi- slice measurements o Cardio images with physiological triggering (such as ECG or pulse) 5. Under Sorting Order, select Ascending or Descending. Sorting Order Ascending =T Descend- ing Exercise: Manipulate an image via the Image Sorting tool You can use Image Sorting to rotate or flip individual images of a series. This function is helpful for example when correcting the presentation of individual images in series generated with radial hip scanning. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 84 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 1. Select one or several images. Use the Shift key to select one image or use the Ctrl key for multiple selection. Load these into the Image Sorting tool. 2. Select Flip Horizontal to manipulate the image. Image Manipulation R R 90 90 ===== Flip Rotate Horizontal Flip Rotate Vertical CW 90* CCW 90º Exercise: Remove images via the Image Sorting tool In Image Sorting, you can remove images that do not contain relevant clinical information, for example at the beginning or end of the series. Alternatively, you can use a combination of specific sorting criteria, selection of individual images, frame removal, and creation of result series to split up series that were scanned interleaved. 1. Select one or several images you want to remove. Use the Shift key to select one image, or use the Ctrl key for multiple selection. Load these into the Image Sorting tool. 2. Mark the images that you want to remove. Images that are marked for removal are marked with a red dog- ear. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 85 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 37 - t1_mprage_ sag_p2 iso 3. Click Remove Selected. Include / Remove Image(s) Em From Beginning Remove Selected To End 4. To undo a selection, select an image that is marked with a dog-ear and click Include Selected. Include / Remove Image(s) E En From Beginning Include En Selected To End Exercise: Save results via the Image Sorting tool Before you save a result series, you should check the resulting series in the Image Sorting tool. 1. Select one or several series and load them into the Image Sorting tool. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 86 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 2. Make sure that the images are presented in the correct sort order, and that they are flipped or rotated as required. Images which have been removed will not appear in the new series. 3. Click Stack as the viewing layout. 4. Scroll through the image stack. 54 54 . tl_mprage_sag_p2_iso Please note: The red bars to the right of the preview indicate where images have been removed from the series. The arrow and frame number indicate which image is currently shown. 5. Check the Series Description. Series Description t1_mprage_sag_p2_iso_PACS Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 87 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Please note: By default, the system adds _PACS to the original series description. Change this suffix or the entire series description as required. 6. Click Create. Create A new series appears in the MR View&GO Series panel. Select and launch 4D data into 3D Display It is possible to select segments containing 4D data, such as dynamic scans, diffusions (b-values) or DIXON (fat/water/in-phase/out-of-phase) and launch them into the 3D application. Exercise: Explore navigating 4D datasets 1. Load a patient study containing a diffusion dataset into MR View&GO. The images are displayed in the segments. 2. Select a 4D image segment. The 4D image segment is indicated by the 4D blue sign. 3. Click Show in 3D in the Favorite Tools area. The data is launched into 3D Display. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 88 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 4. Toggle between the available b-values data via the 4D +/- keys as well as via the ←→ cursor keys. MR View&GO: 3D Post- processing (MIP and MPR) Online training for 3D post‐ processing and 3D Reference Mode To learn more, please follow the link below: Outside US 3D Reference Point Video US 3D Reference Point Video 3D Reference Mode 3D × MPRIMIP MPR/MIP MPR 2TP MPRIVRT MIP THIN 2TP MIP THICK Reset Layout Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 89 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Some workflows provide predefined layouts for 3D visualization. • 3D Reference Mode is activated in these predefined layouts. • Images are displayed in reference segments and in a volume segment. Standard Reference Mode layout • Reference segments: Display images positioned orthogonally to each other by default. • Predefined MPR/VRT layout: Displays MPR thick images in orthogonally positioned segments, and renders a VRT in a volume segment. • Predefined MPR/MIP layout: Displays MPR Thick images in orthogonally positioned segments and MIP in a volume segment. 3D Post‐processing: Show in 3D icon and reference lines Exercise: Explore the 3D tool 1. Select images for 3D visualization or 3D post‐processing. 2. Go to Favorite Tools and select the Show in 3D icon. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 90 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 Favorite Tools X 3D o Show in meCurve ADC & b- Compose/ 3D value Combine 3D Ref. Distance Position Snapshot Print Stack Point Line Displa ... RA Flip Save as Mosaic Subtracti ... Horizontal Series + MR View&GO switches to a 3D layout and images are loaded into the image segments. Please note: The Show in 3D icon is dimmed when an inappropriate dataset is selected. After loading the images into 3D, you can find the following post‐processing options: • Parallel Ranges • Radial Ranges • Radial Slices • Curved Ranges Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 91 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 3D Post‐processing: Show in 3D icon and reference lines Exercise: Explore the 3D tools area: Reference lines The reference lines displayed in each segment show the position of images in other segments. 1. Select and move the reference lines. The reference lines and the related segment are displayed in the same color. 2. To lock or unlock reference lines, select the upper left corner menu. Click Lock Reference Lines. Zoomifan Windowing DET-1.3 12.2.1107 5.99.3 Rotate HFS Scroll Du Movie SheetDiSeries0.Phase0 30 Reference Point Lock Reference Lines F Lock reference lines Save as Series 5cm Fit to Segment F Region Growing TP H2 BVV 579.0 SP H2.3 MPR THICK : p2 MAGN/MNORM DIS2D 288p*320 A1/PFP Tra BO1-3;SP2-5 1175 *h2d1 rr288 / 105 582 Or – – Select the Loc Ref. Lines icon in the 3D tools area. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 92 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 ¥ 3D X MPRIMIP MPRIMIP MPR 2TP MPRIVRT MIP THIN 2TP MIP THICK Rese Layout Parallel Radial Curved Ranges Ranges Slice ... Ranges Punch Clip Box Lock Ref. Lines Please note: Locked Reference Lines is activated, and the reference lines are positioned at a 90º angle to one another by default. All segments are synchronized. 3D Post‐processing: MIP workflow steps Exercise: Explore the 3D tool – MIP workflow – Punch and remove 1. Select a segment with a 3D angiography dataset. 2. Select the Show in 3D icon. 3. Select the MIP Thick icon. 4. Select the Punch icon in the upper left corner menu. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 93 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 ZoomiFan Zoom and pan image [2] Ref IETOM Sola Rotate HR XA20 10 Reference Paint Ranges Punch Clip Plane clip Box Fit to Segment CP 70.1 Anatomy Visualizer 320 2.41 Or – – Select the Punch icon in the 3D tools area. Now, try out the following punching functions: - 3D × MPIOMI MPRIMIP MPR ZTP MPRIVET MITHIN 2TP MP THICK Layout Parailel Rangel Radial Sice Ranges Punch Chip Bax Lock R • Select Remove Outside. Then depress the left mouse button and draw around the vessels. To close the drawing mode, double-click with the left mouse button. Remove Inside Remove Outside Auts Pinch • Right-click on the blue orientation cube to change the orientation. • Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 94 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 • Depress the left mouse button and draw around the vessels. To close the drawing mode, double-click with the left mouse button. • Select the Esc key on your keyboard to close the Punch tool. • Right-click on the blue orientation cube and select Reset Position in All Segments. 5. Select the Radial Ranges icon. • Define the start and end points, and number of images. • Select the Start button. • Enter the Range Series Name. • Select Accept to keep the MIP created. Or – – Select Reject to delete the MIP created. Please note: Double‐click on the MIP image to load MIP into a 1x1 segment (optional). Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 95 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 MR View&GO: TimeCurve To learn more, please follow the link below: Outside US TimeCurve Video US TimeCurve Video Exercise: Explore the MR View&GO TimeCurve function 1. Select a dynamic dataset (such as Test Bolus). The data is loaded into MR View&GO. 2. Go to Favorite Tools and click on the TimeCurve icon. Within the TimeCurve function, you can do the following: • Evaluate Dynamic Datasets: Shows signal changes over time. • Plot Intensity of Contrast Media: Over a certain time period • TimeCurve Layout: o First Segment: Displays dynamic images. o Second Segment: Displays a result curve. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 96 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 3. Press and hold the right mouse button and move it left or right to page through phases until the vessel is visible. 4. Draw a freehand region of interest (ROI) by selecting the TC-Freehand icon. 5. Set an ROI with a defined number of pixels by selecting the TC-Pixel Lens icon. 6. Draw a circular ROI by selecting the TC-Circle icon. 7. Click on TC Snapshot to create the results of the TimeCurve evaluation in the Series Navigator. 8. Select the TC-Circle icon. Then, press and hold the left mouse button and draw a circular ROI on the vessel. 9. To modify the TimeCurve display and switch the X-axis labeling, proceed as follows: Please note: Time Offset and Normal Time are default display values. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 97 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 • Click Normal Time Text to change the display to Image No. • Click Time Offset Text and enter new Time Offset. Select OK. Time Offset ? X Time Relative to Start of Scan Time Offset 0.0 sec 10 sec - 10 seconds after start of scan +15 sec - 15 seconds prior start of scan OK Cancel Mean 11 Race. 30.22 % Time Offoot @ Doc Time Offset Image No. and Normal Time Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 98 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 MR View&GO: Compose and combine To learn more, please follow the link below: Outside US Compose/Combine Video US Compose/Combine Video Overview: Compose and Combine • Compose: Performs composing to create composite images (sagittal or coronal images). • Combine: Combines images to include all images in one series (axial images). Composing prerequisites • Only MR images • All images of a volume need to meet the following criteria: o Have the same image matrix. o Have the same pixel spacing: 𝑃𝑖𝑥𝑒𝑙 𝑠𝑝𝑎𝑥𝑖𝑛𝑔 = 𝐹𝑜𝑉 𝐼𝑚𝑎𝑔𝑒 𝑚𝑎𝑡𝑟𝑖𝑥 o Form a cuboid. Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 99 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 o Belong to one study. o Belong to the same series. o Have the same slice thickness. o Have the same slice distance. o Have the same slice orientation. o Have the same distortion correction for all images (for example 2D corrected, 3D corrected). o For coronal images, only an incline from coronal to transverse is permitted (max. +45º). o For sagittal images. only an incline from sagittal to transverse is permitted (max. +45º). o Inclines in other directions are not permitted. Exercise: Explore the Compose function 1. Select a Spine/Whole Body exam with multiple table moves. 2. Press Ctrl and the left mouse button. Select segments with different table positions (such as C-spine, T-Spine). 3. Click on the Compose/Combine icon: Favorite Tools X Show in TimeCurve ADC & b- Compose/ 3D value Combine Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 100 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 4. The Create New Composition dialog window opens and Available Series and Series Selected are shown. Please note: The series selected for composing are displayed under Selected Series. Create New Composition ? X Selected Series Available Series 4 4 5 Composing Algorithm Spine algorithm Name Of Composed Series Composed Spine 6 7 OK Cancel 5. Under Composing Algorithm, select one of the following algorithms: • Spine: Based on bone structure, for composing spine • Angio: Based on vessel structure • MIP: Optimized to compose MIP images. • Adaptive: This algorithm is based on elastic matching. It corrects b0 induced inhomogeneities in image areas beyond magnetic homogeneity volume (such as abdomen, long bones). Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 101 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 6. Insert the name of the composed series. 7. Select OK. Compose: Post‐processing workflow steps Exercise: Edit and modify composed images 1. Edit composed images using the composing tools. MR View&GO × Stack 3x2 Stack: 2x2 Stack 5x4 · Composer x New Confirm Compose Combine Result Results Composed Spine_COMP illend/Cut Normalize Manual Mode Adjust 11 2. Select Blend/Cut Mode to switch between soft transitions (smooth image transitions) and hard cuts (shows original image borders). Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 102 of 103 SmartSimulator Workbook | Basics: MR View&GO Effective Date: 12 Nov 2024 | QR700015739 3. Apply Normalize to harmonize different grayscale values for a homogeneous overview. 4. Use Manual Adjust to manually align positions of original images. Self-assessment for MR View&GO Congratulations! You have completed the Basics: MR View&GO SmartSimulator workbook. To test your knowledge about MR View&GO, take the online assessment: Outside US MR View&GO Online Self-Assessment Unrestricted | Published by Siemens Healthineers AG © Siemens Healthineers AG, 2024 Master Template Effective Date: 14 Dec 2023 | HILS 2351 Page 103 of 103

  • smartsimulator
  • smart simulator
  • basics
  • MR
  • viewgo
  • view&GO
  • view&go
  • xa70
  • XA70
  • 70
  • smartsim
  • smartsim 70
  • smartsim xa70