Siemens Healthineers Academy
MR - Exporting Protocols Workflow E-line Software (AU)

MR - Exporting Protocols Workflow E-line Software (AU)

A step-by-step guide on how for exporting protocols workflow using E-line software

Exporting Protocols Workflow E-line Software Job Aid MRI Systems E-line Software Note It is recommended to start protocol export only when no scans or other applications are running. When protocols are exporting the system will be blocked and no imaging can take place. 1. Export Protocols · Insert a Flash Drive into the system. 2. Open the Dot Cockpit 3D L Dot Cockpit 53 % Q e(G:): Total Space(7376 MB) 3/12/2015 5:29:55 PM Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: (AU) 26/10/2020 | HOOD05162003139466 Healthineers Job Aid | Exporting Protocols Workflow E-line Software Effective Date: (AU) 26/10/2020 | HOOD05162003139466 3. Select Export in the Dot Cockpit Explorer Dot Cockpit - Explorer ? X EXPLORER PROGRAM EDITOR Browse Import Export X Local Database ... lesion Edit USER 11_se_r_tra_320 11_se_r_cor clinical libraries general 11_se_r_sag_320 =Open existing file ... lesion D. Create new file ... trauma neurodegeneration 11_space_sag_p2_isc epilepsy ms 11_mprage_sag_p2_i: pituitary 4. In the Tree View or Content area select the object to be exported. a. Start the Export > Select the Arrow icon or select Create new file Dot Cockpit - Explorer ? X EXPLORER PROGRAM EDITOR Browse Import Export X Local Database ... Te lesion Edit USER 11_se_r_tra_320 Q 11_se_r_cor clinical libraries general 11_se_r_sag_320 =Open existing file ... lesion Create new file ... trauma neurodegeneration t1_space_sag_p2_isc epilepsy ms t1_mprage_sag_p2_i: pituitary Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: (AU) 26/10/2020 | HOOD05162003139466 Healthineers Page 2 of 5 Job Aid | Exporting Protocols Workflow E-line Software Effective Date: (AU) 26/10/2020 | HOOD05162003139466 5. Save As Dialogue window open a. Select the Export location b. File Name – Enter a file name for the export file (file extension * .exar-1) c. Select Save Save As X Libraries > Documents Search Documents Organize New folder BEE ? Downloads %] Recent Places Documents library Includes: 2 locations Arrange by: Folder - B Libraries Name Date modified Type Size Documents No items match your search. Music Pictures Videos a Computer # 2. Med_System (C:) med_data (D:) med_pixel (E:) B) - Removable Disk (F:) med_ipt (I:) Med_System (T:) Med_System (U:) File name: Orbits.exar1 Save as type: ( *. exar1) Hide Folders Save Cancel Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: (AU) 26/10/2020 | HOOD05162003139466 Healthineers Page 3 of 5 Job Aid | Exporting Protocols Workflow E-line Software Effective Date: (AU) 26/10/2020 | HOOD05162003139466 6. Select any Additional Objects to be exported. a. Click the Arrow (Shuttle button) or Drag and Drop into the File Area Dot Cockpit - Explorer EXPLORER PROGRAM EDITOR Browse Import Export x Local Database program F:\Export\Orbits.exar1 training Skyra-XQ New Tree Q Q head Orbits Brain Dot Engine › Routine clinical libraries head advanced applications libraries Brain Dot Engine bold imaging diffusion and perfusion morphometry pre-surgical planning Optimized protocols for EC programs library Orbits Routine Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: (AU) 26/10/2020 | HOOD05162003139466 Healthineers Page 4 of 5 Job Aid | Exporting Protocols Workflow E-line Software Effective Date: (AU) 26/10/2020 | HOOD05162003139466 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: (AU) 26/10/2020 | HOOD05162003139466 Healthineers Page 5 of 5

  • exporting protocols
  • E-line