
How to Create a New CT Recon Job Aid
This job aid will show how to create a new CT recon after the CT scan is completed.
How to Create a New CT Recon Job Aid Nuclear Medicine Technology-SPECT This job aid will demonstrate how to create a new CT recon after the CT scan is completed 1. Open the Examination task card Applications Workflows Utilities Options System Help Study Name: ALL Show All · Local MI Apps Study Date: ALL Network Category All Up Time: 4 Days 8 Hours 19 Mins Database: Local Find tients found on the system. Study dates: (al dates) Image Space Available : 567115 MB Auto Filter ht Neme |Patient ID Most Rece. # Studies # Series Database Locat Template Name Template C Examdi Hemangioma 110099 29-Dec-20 .. 1 2 Local Database ITest-2 Bed Tc99m Acq CT16+ Acquires, c Aerosol ECAM 16-Feb-20. Local Database 1 xSPECT Recon Use to rec Xe VIQ ECAM 23-Feb-20. 2 Local Database 10 Heart Recon BMPP+TICI Proc - THERA_recon Anonymous 10-Feb-20 ... 41 Local Database 2 Amyloid Static Proc Uses Serie 10, Breast Mammo Pallet Breast 01-Aug-20 ... 1 Local Database 2 Bed Matrix Conversion 64x64 Conver Examination no, Sential Node Anonymous 23-Apr-20 2 Local Database 2 Bed Tc99m Acq CT16+ Acquires, c ion Anonymous 06-Dec-20 ... 3 Local Database 3 Bed Matrix Conversion 64x64 converts Score_SymbiaT06 Cardiac US01 27-Apr-20. 3 Local Database 3 Bed Tc99m CT16+ 1, tomo C20088305 16-Apr-20 2 Local Database 3 Phase Bone Display ways fk PEDS. MBG 15-Mar-20 3 Local Database Viewing .3 View ECAM 3 Phase Bone with Wholebody 3 Phase B 01-Apr-20 ... 6 Local Database 3 Phase Bone Acquires d tomo Anonymous 24-Mar-20. 8 Local Database 3. HT Cardiac Proc 2 Day Use to Pro ardial Perf Tc ecam 01-Feb-20. Local Database 3. HT CARDIAC PROCESS PROCESS ascan 100329 05.Feb.20 1 Local Datahase 13PHASE ACO ACQUIRES Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 10 Aug 2021 | HILS 2224 Job Aid Effective Date: 08 SEP 2022 | HOOD05162003297757 Healthineers Job Aid | How to Create a New CT Recon Effective Date: 08 SEP 2022 | HOOD05162003297757 2. Highlight the Patient from the upper left corner and display the pull down list Pabel Applications Edit Insert View Setup Image Options System Help Regis Num 0 Emergency .. MI Apps Browser Num Examination Job Status Close Patient Filming Layout. Film Task Status. Film Preview .. Examination Expose Film Task Ctrl+P 3. Select the Browser Patient Applications Edit Insert View Setup Image Options System Help Register ... Num O Emergency MI Apps Browser Num Examination Job Status Close Patient Filming Layout .. Film Task Status .... Film Preview ... Examination Expose Film Task Ctrl+P SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 2 of 7 Job Aid | How to Create a New CT Recon Effective Date: 08 SEP 2022 | HOOD05162003297757 4. Select the Raw CT series from the patients list Filter Evaluation Sort Options Help do Sto Ca RDIAC TL201, TL201 [1003] Gated Rest TL201 diac, Shunt [1001] AC BH Rest Cardiac 5.0 B08s diac4, SC CTAC. Myocardial Perfusion [4] RAW RDIAQUE, CT F Cardiac DC F Cardiac DD F Cardiac WJ E CARDIAC Date of birth 21-Feb-1883 Patient ID Workflow Study date 21-Feb-2006 Modality CT KV KV mAs Gantry Tilt |Kernel |FoV|Image Comm ... Mark Status | Work Status mAs 130.0 118 0.00 [B08s] 500 1111/ 130.0 118 0.00 [B08s] 500 11/// 130 0 118 0.00 18081 500 5. Highlight Patient in the upper left corner and select CT RECON. The CT patient data will load into the Exmination Task card Patient Browser Patient Applications Transfer Edit View Register .. Num 0 Emergency .. Load to Viewing Load Report Load Last Report CT Examination CT Recon Update Reference Lines Mode Reference Lines Export CT Data mport CT Data .. Filming Layout ... Film Task Status ... Film Preview. Expose Film Task Ctrl+P Copy to Film Sheet Num Enter Show MPPS Complete MPPS Print Preview Print List Print ... Search Search Selected .. Close Browser Alt+F4 SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 3 of 7 Job Aid | How to Create a New CT Recon Effective Date: 08 SEP 2022 | HOOD05162003297757 6. Select the Recon at the bottom of the page OT Lung 123400 OLal ITAS. Topogram Recon job 3 4 5 6 Series description ThorRoutine 5.0 B70s ThorRoutine Slice 5.0 mm ] Recon job type · Axial 3D IRIS Kernel B70s sharp Window Lung Recon begin -1318.5 mm Recon end -1033.5 mm Extended Fov M FOV 288 mm Image order Craniocaudal Center X 17 mm Recon increment 5.0 mm Overview Center Y 0 mm = No. of images 58 Mirroring None Comments Extended CT scale M Load Hold Recon Recon Routine Scan Recon tuto Tasking 7. Select the next available Recon Job that does not have a bullet ThoraxKouunevos (Aquiy) CT Lung 23400 Total MAS. Topogram Recon job Series description ThorRoutine 5.0 B70s ThorRoutine Slice 5.0 mm ] Recon job type · Axial 3D IRIS Kernel B70s sharp M Window Lung Recon begin -1318.5 mm == Recon end -1033.5 mm= Extended Fov r FOV 288 mm 2 Image order Craniocaudal Center X 17 mm == Recon increment 5.0 mm Overview Center Y 0 mm == No. of images 58 Mirroring None Comments Extended CT scale SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 4 of 7 Job Aid | How to Create a New CT Recon Effective Date: 08 SEP 2022 | HOOD05162003297757 8. Select the Kernel drop down list and select the desired kernel Total mAs: 1552 Filming ThoraxRoutine06s (Adult) CT Lung 123456 Topogram Recon job 2 3 4 5 6 7 8 Series description ThorRoutine 5.0 B70s ThorRoutine Slice 5.0 mm Recon job type · Axial 3D IRIS Kernel B70s sharp Window B20s smooth Recon begin -1318.5 mm 3D B30s medium smooth B31s medium smooth + Recon end -1033.5 mm == B35s HeartView medium B40s medium Extended FB41s medium + Image order Craniocaudal B46s HeartView sharp B50s medium sharp Recon increment 5.0 mm 2: Overview B60s medium sharp B70s sharp No. of images 58 Mirro B80s very sharp Comments B90s very sharp Extended CT squgos ultra sharp Load Hold Recon U91s ultra sharp Routine Scan Recon Auto Tasking 9. Select the Recon circle to create the new recon job ThoraxRoutine06s (Adult) CT Lung 123456 Total mAs: 1552 Topogram Recon job 234 5 67 Series description ThorRoutine 5.0 B70s ThorRoutine Slice 5.0 mm ] Recon job type o Axiel 3D IRIS Kemel B70s sharp Window Lung Recon begin -1318.5 mm Recon end -1033.5 mm Extended Fov r FOV 288 mm Image order Craniocaudal Center X 17 mm = Recon increment 5.0 mm 2 Overview Center Y 0 mm il No. of images 58 Milcorra None Comments Extended CT scale m Load Recon Recon I Start reconstruction for the selected recon ingran Recon Auto Tasking SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 5 of 7 Job Aid | How to Create a New CT Recon Effective Date: 08 SEP 2022 | HOOD05162003297757 10. After the recon Job is created, select the close patient icon on the left side of the exam card ThoraxRoutine 06s (Adult) CT Lung 123456 Total mAs: 1552 Topogram Recon job 234 561 7 8 Seres description ThorRoutine 50 870s * ThorRoutine Sice 50mm Kemel [B70s sharp Window Lung Reconbegin -1318 5mm Recon end -1033.5 FOV 288 mm: Image order Craniocaudal 17 mm 21 50 mm: CITY No ofimages Nooe Comments Exceoded CT scale Routine Scan Recon Auto Tasking You can now view the new Recon job in the patient browser. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 6 of 7 Job Aid | How to Create a New CT Recon Effective Date: 08 SEP 2022 | HOOD05162003297757 Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (here- inafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 7 of 7
- CT
- CT Recon
- scan
- CT scan
- ct