Dual Source CT - Dual Energy video

Dual Source CT - Dual Energy video

This video shows the advantages of Dual Energy spectral imaging to cover large anatomical volumes at high speeds and low doses.
 
Disclaimer:
 
Please note that the learning material is for training purposes only! 
 
For the proper use of the software or hardware, please always use the Operator Manual or Instructions 
for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be
used as training material only and shall by no means substitute the Operator Manual. Any material used 
in this training will not be updated on a regular basis and does not necessarily reflect the latest version of 
the software and hardware available at the time of the training.
 
The Operator Manual shall be used as your main reference, in particular for relevant safety information 
like warnings and cautions.
 
Note: Some functions shown in this material are optional and might not be part of your system. The 
information in this material contains general technical descriptions of specifications and options as well
as standard and optional features that do not always have to be present in individual cases.
 
The reproduction, transmission or distribution of this training or its contents is not permitted without
express written authority. Offenders will be liable for damages.
 
All rights, including rights created by patent grant or registration of a utility model or design, are 
reserved.
 
Copyright © Siemens Healthcare GmbH, 2019

Dual energy powered by dual source CT. You have many options today when it comes to spectral imaging applications, including fast or slow cavey, switching, dual layer detectors, and dual source dual energy CT, single source cavey switching lets you achieve reasonable quality results in most situations, but not without speed compromises, patient size limitations and spectral blurring. Additionally, the quantity of Ms remains constant during cavey switching. Leading to a higher than necessary dose. Dual layer detectors enable faster scan speeds than cavey switching, however they are not precise enough to properly distinguish between high and low energy photons and therefore suffer from poor spectral separation. The dose is also high because dual layer detectors require fixed power settings and Ms quantities throughout the acquisition. Dual source CT scanners offer a dual energy mode that lets you dial in different cavey and Ms settings for each tube so you can cover large volumes at high speeds. When it comes to dose, the raw output of a dual source CT scanner is compara bulto, a standard single source acquisition. But you actually get an even lower dose thanks to the built-in tin filter. That in filter doesn't only lower dose. It also enhances spectral separation and this naturally improves image quality. With dual source ET you can achieve dual energy acquisitions with optimal dose speed and quality. Dual energy powered by dual source CT. Part of our unmatched scan modes. Dual source ET ready beyond tomorrow.

Single Source Single Dual Source Dual Source CT Single Source Dual Source Dual Energy CT Dual Source CTal Dual Source CT Energy CT Options for Dual Energy spectral imaging CT kV-switching Dual Lager Dual layer CT CT Energy CT Dual Energy with Tin Filter The 5 Dual Source CT modes Dose • Speed compromises • Each tube at different kV and mAs Lack of precision Number of quanta Number of quanta (D Low kV Low kV Low kV High kV High kV SIEMENS powered by Dual Source CT Patient size limitations High-speed scanning Poor spectral separation Poor Overlap Fast temporal Turbo Flash Dual Energy Dual Power Adaptive Source CT • Spectral blurring High dose resolution 4D spiral • Constant mAs quantity Ready beyond tomorrow Healthineers High dose Optimal dose, speed, powered by Dual Source CT C). and quality Source CT Single Source CT Single Source Energy Photon energy Standard Dual Energy CT Dual Energy acquisition acquisition High kV Enhanced spectral separation for improved image quality High kV kV-switching Dual layer Dual Lager Dual Source Low dose thanks to Tin Filter Dual Energy CT Low kV Low kV (e.g. 120 or 140 kV)

  • dual
  • source
  • ct
  • layer
  • speed
  • scanning
  • tin
  • filter