Create a Dot Engine/myExam Assist and MPR Planning
This job aid demonstrates you how to create a Dot Engine/myExam Assist program and set up MPR Planning using the Program Editor in the myExam Cockpit.
Create a Dot Engine/myExam Assist & MPR Planning Job Aid MR (Numaris X Software) 1. Create New Region a. Select Organize Directories b. Select New Region Directory c. Type Name > select Enter myExam Cockpit - Explorer myExam Cockpit - Explorer Explorer Program Editor Explorer Pro Browse Import Export Edit Sim Browse Import Export X 1 X Facilty New Region Directory Facilty Name outing New Exam Directory Creates a new region New Program Brain >Brain Knee 2. Select New Region Created 3. Create New Exam Directory a. Select Organize Directories i. Select New Exam Directory ii. Type Name > select Enter myExam Cockpit - Explorer myExam Cockpit - Explorer Explorer Prog Explorer Pro Browse Import Export Ed Browse Import Export X X Facilty New Region Directory Facilty Name New Exam Directory Q Create a new exam inside the selected region Brain Brain Knee Knee [ Dot/myExam standard SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date: 10 Aug 2021 | HILS 2224 Healthineers Job Aid Effective Date: 29 Mar 2022 | HOOD05162003263718 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 4. Select New Exam Created 5. Create New Program a. Select Organize Directories i. Select New Program ii. Program Editor > Edit window opens myExam Cockpit - Program Editor (New Program) Explorer Program Editor Browse Import Export Edit Simulate X in "> Standard Browse Search Default myExam Autopilot SIEMENS myExam Cockpit - Explorer Explorer Pro Browse Import Export [ head Brain Assist E program Facilty New Region Directory clinical libraries New Exam Directory E general New Program E lesion Create a new program E trauma Brain E atrophy Knee AAhead_scout 00:14 AutoAlign S. [ Dot/myExam standard t1 tse_r_tra_p2 03:56 t1_tse_dark-fluid_sag_p2 04:38 t2_tse_dark-fluid_tra 03:38 Strategy Decision Interaction Pause SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 2 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 6. Add a New Strategy a. Select Sidebar > Strategy i. Drag and drop Strategy from the sidebar into the Measurement Program myExam Cockpit - Program Editor (New Program) ? O x Explorer Program Editor Browse Import Export Edit Simulate >> Standard Browse Search Default myExam Autopilot SIEMENS Patient View Basic Patient View V Strategy head Brain Assist E program clinical libraries E general E lesion E trauma E atrophy AAhead_scout 00:14 AutoAlign S ... t1_tse_r_tra_p2 03:56 t1_tse_dark-fluid_sag_p2 04:38 t2_tse_dark-fluid_tra 03:38 Strategy Decision Drag to create a strategy. Pause 7. Change Strategy Name a. Select F2 – Rename Strategy > select Enter SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 3 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 8. Add Program Step a. Select Sidebar > Browser i. Select Siemens Tree ii. Exam > Study > Program > select Program Steps 1. Drag and drop Program Steps from the sidebar into the Measurement Program iii. Please Note: Continue to add additional program steps from other trees, studies, exams, or program areas until all non-contrast program steps have been incorporated myExam Cockpit - Program Editor (New Program) ? O x Explorer Program Editor Browse mport Export Edit Simulate >> Standard Browse Search Default myExam Autopilot SIEMENS Knee Assist @ Ortho Patient View V Standard AAKnee_Scout 00:14 Knee Assist AutoAlign Scout pd_tse_fs_tra_448 04:07 El general 2D Generic Views E general 3D pd_tse_cor_544 04:11 E lesion Generic Views >[ library pd_tse_fs_cor_512 04:26 clinical libraries 1 Generic Views pd_tse_sag_512_2.5mm 03:59 › Dankle 2 Generic Views A refont t1_se_sag_448 03:57 2 Generic Views t2_blade_fs_sag_320 04:10 > 2 Generic Views Q,Click to open full view Strategy Decision Interaction Pause SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 4 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 9. Add a 3D Program Step a. Select Sidebar > Browser b. Select Siemens Tree > Exam > Study > Program > select Program Steps c. Drag and drop 3D program steps from the sidebar into the Measurement Program d. Please note: Continue to add additional program steps from other trees, studies, exams, or program areas until all 3D Program steps have been incorporated myExam Cockpit - Program Editor (New Program) Explorer Program Editor x Browse Import Export Edit Simulate X >> Standard Browse Search Default ... » knee >> Knee Assist >> general 3D Q Q myExam Autopilot SIEMENS GOKnee3D Ortho Patient View nee Assist Ortho Patient View V Standard Standard 1% & t2 space V AAKnee Scout 00:14 AutoAlign Scout AAKnee Scout 00:14 1 nip [3] AutoAlign Scout knee [3] pd_space sag iso 05:07 pd_tse_fs_tra_448 04:07 [] Knee Assist [1] MPR Assignment t2_space_fs_sag_iso 04:39 Generic Views E general 2D 1 MPR Assignment pd_tse_cor_544 04:11 Generic Views E general 3D [1] MPR planning ... pd_tse_fs_cor_512 E lesion MPR Planning 04:26 1 Generic Views library [2] pd_tse_sag_512_2.5mm 03:59 [ clinical libraries 2 Generic Views t1_se_sag_448 03:57 GOKnee3D @ Ortho Patient View · 2 Generic Views Standard t2_blade_fs_sag_320 04:10 AAKnee Scout 00:14 2 Generic Views AutoAlign Scout t2_space_fs_sag_iso 04:39 pd_space sag_iso 05:07 1 O MPR Assignment MPR Assignment t2_space_fs_sag_iso 04:39 O MPR Assignment MPR planning ... MPR Planning @ Click to open full view Strategy Decision Interaction Pause SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 5 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 10. Add an Interaction and Insert Default Add-in a. Select Sidebar > Interaction i. Drag and drop Interaction from the sidebar into the Measurement Program b. Insert Default Add-in i. Select Default tab > Default Addins ii. Drag and drop MPR Planning from the sidebar into the Interaction step myExam Cockpit - Program Editor (New Program) . x Explorer Program Editor Browse Import Export Edit Simulate >> Standard Browse Search Default myExam Autopilot Patient View AddIns [13] Knee Assist Ortho Patient View Default AddIns [44) Standard Liver Quantification AAKnee_Scout 00:14 Liver Segmentation AutoAlign Scout @ Morpho pd_tse_fs_tra_448 04:07 MPR Assignment O Generic Views O MPR Planning pd_tse_cor_544 04:11 Generic Views O Nee MPR Planning Configures the planning of MPR ranges pd_tse_fs_cor_512 04:26 O Onc for 3D measurements when attached to 1 Generic Views an Interaction step. The selection of O Phas desired MPR ranges to be processed is pd_tse_sag_512_2.5mm 03:59 done in the corresponding MPR Pros Assignment step. Maximum of one MPR 2 Generic Views QIS Planning per program. t1_se_sag_448 03:57 More · 2 Generic Views RT Planning t2_blade_fs_sag_320 RT Table Move + 2 Generic Views Spectroscopy t2_space_fs_sag_iso 04:39 O MPR Assignment Spine Positioning Interaction Spine Scout MPR Planning Spine Verification Default Sequences [135] Strategy Decision Interaction Pause Drag to create an interaction. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 6 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 11. Set up MPR Planning a. MPR Planning > right mouse click and select Edit Properties… b. Select Addin Configuration… >> Interaction General Preview Name Interaction Description Interaction myExam Addin @ MPR Planning MPR Planning Copy Ctrl+C Confirm before start Paste Ctrl+V Delete View Properties ... Edit Properties ... Addin Configuration ... OK Cancel SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 7 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 12. Siemens Dot Add-in Configuration window a. Select MPR Planning b. Select Guidance (+) > Adds guidance layout i. Define MPR setup > Name, Guidance images and text ii. Select F2 – Rename Strategy > select Enter myExam Add-In Configurator X 7 6 Queue Guidance + - Parameters GSP Layout 2 images BA AA Auto Load MPR Planning Axial "NOTICE: please configure / Tooltip Tooltip Coronal guidance text here" MPR 3 Add MPR range Remove MPR range 1 Remember to select the desired MPR ranges to be processed in the corresponding MPR Assignment steps. Close SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 8 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 13. MPR Planning > Guidance Tab a. Add GSP Images using the Camera or Folder icons i. Camera – capture screenshot of patient images in Exam task card 1. Please Note: Patient must be registered ii. Folder – use images stored on an external device (USB, File Browser, etc.) 1. Please Note: File type supported – jpg, png, gif, bmp myExam Add-In Configurator ? × Queue Guidance + - Parameters GSP Auto Load Layout 2 images MPR Planning Axial "NOTICE: please configure Tooltip / Tooltip Coronal guidance text here" MPR 3 Add MPR range Remove MPR range Remember to select the desired MPR ranges to be processed in the corresponding MPR Assignment steps. Close SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 9 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 14. MPR Planning > select Parameters tab a. Define the following per Orientation (Sag, Cor, Tra, etc.) i. FOV Height x Width ii. Slice Thickness iii. Slice Dist. Factor iv. Slices v. Image Numbering vi. AutoAlign vii. Position viii. Orientation ix. Add MPR range x. Remove MPR range b. Select Close > OK myExam Add-In Configurator ? x Queue Guidance Parameters GSP Auto Load FOV Height x Width 100 - mm x 100 % MPR Planning Axial Coronal Slice Thickness 1.0 mm MPR 3 Slice Dist. Factor 0 % Slices 10 Image Numbering A>> P AutoAlign| --- Position Iso Center Add MPR range Orientation Coronal Remove MPR range 1 Remember to select the desired MPR ranges to be processed in the corresponding MPR Assignment steps. Close SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 10 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 15. Add MPR Assignment a. Select Default tab > Default Addins i. Drag and drop MPR Assignment from the sidebar into the 3D Program step myExam Cockpit - Program Editor (New Program) ? O x Explorer Program Editor Browse Import Export Edit Simulate >> Standard Browse Search Default myExam Autopilot Patient View AddIns [13] Knee Assist Ortho Patient View Default AddIns [44] V Standard Care Bolus AAKnee_Scout 00:14 @ Elastography AutoAlign Scout Generic Views pd_tse_fs_tra_448 04:07 Interactive Real Time Generic Views Liver Quantification pd_tse_cor_544 04:11 1 Generic Views Liver Segmentation pd_tse_fs_cor 512 04:26 Morpho 1 Generic Views MPR Assignment pd_tse_sag_512_2.5mm 03:59 MPR Assignment 2 Generic Views Selects the desired MPR ranges of 3D t1_se_sag_448 03:57 measurement protocols to be 2 automatically created based on the Generic Views configuration in the corresponding MPR t2 blade_fs_sag_320 04:10 Planning step. More 2 Generic Views Prostate t2_space_fs_sag_iso 04:39 MPR Assignment Default Sequences [135] Interaction Strategy Decision MPR Planning Interaction Pause ii. Assign the ranges to be reconstructed for individual protocol steps b. MPR Assignment > right mouse click and select Edit Properties c. Select Addin Configuration SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 11 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 >> t2_space_fs_sag_iso ? x General 8 4:39 min 4 Auto @ 4 @ 0.6x0.6x0.6 mm3 1.00 Protocol Parameters Guidance Parameters Voice Commands Execution Image Management Auto Load Slabs FoV Read 160 - mm Interaction Copy References Slice Thickness 0.63 4 mm FOV Phase 100.0 ¢ % MPR Planning Copy Ctrl+C Preview Paste Ctrl+V Delete View Properties ... TR 1000.0 + ms Edit Properties ... Concatenations Slices per Slab 192 Addin Configuration ... OK Cancel i. Select MPR Assignment ii. Select which of the MPR ranges that you defined in the MPR Planning step will be reconstructed from the data acquired by the current step 1. Please note: Default is none checked iii. Select Close myExam Add-In Configurator X Guidance Parameters Generate the following selected MPRs Queue GSP Axial Series Label Coronal MPR 3 Auto Load AutoCoverage AutoTiming MPR Assignment Close SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 12 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 16. Save Program As a. Select Save Program As icon myExam Cockpit - Program Editor (New Program) Explorer Program Editor Browse Import Export Edit Simulate Save program as i. Save As window > type Name of Program ii. Select Save Save as ? X Facility Name Brain routine Knee Dot/myExam standard Name routine Enter new name or select an existing program Save Cancel Tip: Dot Engines/myExam Assists & MPR Planning • Only 1 MPR Planning step per strategy or Non-Dot Engine / myExam Assist • Only one MPR Planning step per Dot Engine / myExam Assist if the MPR Planning Step is expanded over all Strategies SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 13 of 14 Job Aid | Create a Dot Engine/myExam Assist & MPR Planning Effective Date: 29 Mar 2022 | HOOD05162003263718 Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration-dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 14 of 14
- cockpit
- myExam
- cockpit
- program editor
- editor dot cockpit
- editor dot
- edit cockpit
- edit program
- mpr
- planning