Cleaning and Disinfection Guide of Siemens MR Systems
Proper cleaning and disinfection guide for Magnetom Systems
Cleaning, Decontamination, & Disinfection MAGNETOM FAMILY All instructions in the operator manual regarding cleaning and, when applicable, regarding disinfecting and sterilization must be always observed. A WARNING Improper cleaning of the MR system! Risk of electric shock . Only clean the MR system with a damp cloth. 1. Use commercially available cleaning and disinfection solutions. Follow the manufacturer's instructions. Follow the lists of approved detergents in the separate subchapters. 2. Do not use hard or sharp objects (e.g. knives or tweezers) to remove residue. 3. Do not pour cleaning fluid on surface areas and do not spray fluids always use a damp cloth for cleaning. - 4. Do not submerge in cleaning or disinfection liquid. Do not rinse with water. For information regarding cleaning of RF coils, see: Operator Manual Coils SIEMENS siemens-healthineers.com/en-ph Healthineers Cleaning the patient table, the straps, the plugs and connectors Approved Not approved Aldehydes 25 vol% Benzine undiluted Quaternary compounds 1 vol% Acetone Guanidine derivatives 2 vol% Alcohol solution (for Peroxide compounds 6 wt% example, 70% iso- propyl alcohol and Pyridine derivatives 2 vol% 30% water) Chloro derivatives 1 wt% Commercially available cleaning agents, detergent substances 10 vol% Alkylamine 0.5 vol% Organic acids 2 vol% 1. Carefully wipe the plugs and connectors with the cloth. Do not touch the contacts. 2. Wash the straps of the patient table at a temperature of 60°C. Cleaning and disinfecting the receptors ◆ Do not use cleaners or disinfectants containing alcohol or ether. Cleaning system components. WARNING Flammable cleaning or disinfection agents may cause fire or explosion! Injury to patient . Disinfect the system components with commercial disinfecting materials. However, do not use solutions with alcohol or acetone. Follow manufacturer's instructions. Published by Siemens Healthcare Inc. · Printed in Country © The following table shows classes of active agents with concentrations that have been tested and are approved. The detergents under “not approved” must not be used. Approved Not approved Aldehydes 25 vol% Benzine undiluted Quaternary compounds 1 vol% Acetone Guanidine derivatives 2 vol% Peroxide compounds 6 wt% Pyridine derivatives 2 vol% Alcohol solution (for example, 70% isopropyl alcohol and 30% water) - Chloro derivatives 1 wt% Commercially available cleaning agents, detergent substances 10 vol% Alkylamine 0.5 vol% Organic acids 2 vol% Cleaning the LCD monitor/video display The LCD monitor of the syngo Acquisition Workplace and the video display are cleaned in the same way. 1 Clean the LCD monitor/video display at least every two months. 2 Prior to cleaning, switch off the LCD monitor/video display and disconnect the main power plug. But if the monitor/display is under hot running conditions, please wait till the monitor/display is chilled (this can take up to one hour). 3 Clean the monitor/video display using a microfiber cloth. 4 If the LCD monitor/video display cannot be effectively cleaned with the microfiber cloth: use window cleaner. Do not use window cleaner on the monitor housing. 5 Immediately remove any water drops from the LCD monitor/videodisplay. 6 Avoid scratching the surface area of the LCD monitor/video display. 7 Avoid impacts to the LCD monitor/video display. Published by Siemens Healthcare Inc. · Printed in Country © The LCD monitor/video display are highly sensitive to mechanical damage. Cleaning the camera lens ◆ Carefully clean the camera lens with a lint-free cloth and lens cleaner. Cleaning the data carrier 1 Clean contaminated data carriers with a clean cloth (cotton or microfiber). 2 Follow the manufacturer's notes when cleaning CD/DVD data carriers. Care and cleaning of floors Do not use the following cleaning or care products: ◾ Sprays ◾ Silicon-based cleaning or care products ◾ Cleaning or care products with substances that release ammonia ◾ Cleaning or care products that destroy the anti-static properties of the floor covering ◆ Use commercially available cleaning or care products for the floor. Follow manufacturer's instructions. Reference: MR System | Operator Manual Print No. MR-02501.621.01.02.02. Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Siemens Healthineers Philippines Siemens Healthcare Inc. 10the Floor, M1 Tower 141 H.V. Dela Costa street, Salcedo Village, Makati City 1227 Philippines Phone: +3 8814 6765 siemens-healthineers.com/en-ph Published by Siemens Healthcare Inc. · Printed in Country ©
- coronavirus
- korona
- koronavirus
- corona
- covid
- kovid
- wuhan
- covid19
- covid-19
- kovid19
- CDC
- crona
- krona
- kovid
- covid
- cvid-19
- kvid-19
- WHO
- aacc
- lab guidelines