Atellica® UAS 800 Analyzer System Preparation Practical Exercise

Atellica® UAS 800 Analyzer System Preparation Practical Exercise

Log into the software. Load and register cuvettes.

To receive a certificate of completion, take the Atellica™ UAS 800 Analyzer Routine Operations Assessment.

AtellicaTM UAS 800 Analyzer SIEMENS System Preparation Practical Exercise Healthineers Objectives: • Log into the software • Load cuvettes • Register cuvettes Supplies Needed: • Cuvettes • Personal Protective Equipment Helpful Hints: This exercise involves loading and registering new cuvettes, therefore, it is recommended to select a time that is convenient with your laboratory workflow. *Not available for sale in the U.S. Product availability varies by country. 1 IM HOOD05162002602819 © Siemens AG 2013. All rights reserved. Page 1 Hardware Overview Effective Date: 06/22/2017 SIEMENS System Preparation Healthineers Logging on 1. Press the power button on the analyzer. 2. Turn on the personal computer (PC). 3. When the dialog box appears, type in login name and SIEMENS Healthineers password. Atellica UAS 800 4. Select OK. Automated Urine Sediment Analyzer Username Password Logging off Select Logout in the Menu bar. Ok 1. Version 4.0.72 | @ 2015 Siemens AG 2 © Siemens AG 2013. All rights reserved. Page 2 SIEMENS System Preparation Healthineers Loading cuvettes CE IVD 1. Open the front cover. CE [IVD ] CE [IVD] CE LIVD LOT 2. Rotate wing screw to the left on top of cuvette carousel. 2019-04-23 2 2019-04-23 LOT 160429516 160429512 Z 2019-04-23 LOT] 160429616 LOT 2019-04-23 160429516 Atellica UAS 800 3. Lift and remove top of cuvette carousel. e3 Atellica URS 800 50 Quvettes Eso Quettes Atellica UAS 800 Atellica uns Co 4. Open cuvettes carton and remove registration card. EYS Ouettes 5. Load a single cuvette cartridge into the carousel. A Image of cuvettes carton 6. Turn the carousel clockwise to the next empty slot. 7. Load cuvette cartridges until the carousel is full. 8. Replace top on carousel and tighten wing screw. 9. Remove tape at the bottom of each cuvette cartridge. 10. Close the front cover. OO Note: Cuvettes must be registered with the system before processing samples. 3 © Siemens AG 2013. All rights reserved. Page 3 SIEMENS System Preparation Healthineers Cuvette Registration (44) Registering cuvettes You must register cuvettes before using them on the analyzer. 1. Select the Measure icon. Remove the registration card from the front of the cuvette box and 2. Select the Cuvette Reg button. then click the green check button. Insert the cuvette registration card into the barcode scanner slot 3. Press the check. when prompted. Insert the registration card in the sampling area with barcode . To cancel registration click the red X button. 4. facing the reader. 3 X 5. Select the check to return to the Measure screen. Barcode scan successful. (69) Cuvette registration complete. 5 Cuvette Reg 4 © Siemens AG 2013. All rights reserved. Page 4 Hardware Overview System Preparation Review Questions Review Questions 1. Which screen do you need to access to register cuvettes? 5 © Siemens AG 2013. All rights reserved. Page 5 Software Overview System Preparation Review Questions Review Questions Answer Key 1. Measure screen 6 © Siemens AG 2013. All rights reserved. Page 6