Siemens Healthineers Academy
Atellica® UAS 60 Quality Control Job Aid

Atellica® UAS 60 Quality Control Job Aid

This job aid will show how to order QC, load QC samples, review QC results, and manage new lots of QC. 

Atellica® UAS 60 SIEMENS Healthineers Quality Control Job Aid Ordering QC in the Software Settings Low Diagrams High Diagrams - Low level Lots Low level Lot settings (p/pl) 1. Select Quality Control in the software. 2 Use Expiration date Lot number Liquid type Lot number: 47441 DATABASE 11/30/2016 47441 Quantimetrix Dip and Spin Liquid type: Quantimetrix Dip and Spin 1 2. Select the low and high level QC liquid lot you Expiration date: 11/30/2016 QUALITY CONTROL would like to run. RBC min: 0 RBC max: 15 • QC liquid lot selection does not need to be WBC min: 0 INFO performed before every QC measurement. The WBC max: 15 software remembers the previous selection. 3 NEW MODIFY DELETE SELECT CANCEL SAVE QC liquid lot selection needs to be performed only if you change the QC liquid lot. High level Lots High level Lot settings (p/p1) 2 Use Expiration date Lot number Liquid type Lot number: 47442 * 11/30/2016 17442 Quantimetrix Dip and Spin 3. Enable the QC liquid lot by selecting the Select Liquid type: Quantimetrix Dip and Spin button. A star icon will appear next to the level Expiration date: 11/30/2016 of QC that has been selected. RBC min: 10 4 4. Select Start QC. START QC PRINT EXPORT EXIT Not ready Operator Particle classes: 17 10:37:15 AM NOTE: Generally, there are two types of control solution used: normal which is the low level, and abnormal which is the high level. Template Effective Date: 2 Jan 2025| HILS 2223 1 Effective Date: 31 Jan 2023| HOOD05162003328177 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Atellica® UAS 60 SIEMENS Healthineers Quality Control Job Aid 1 Loading QC Samples 1. On the analyzer, press the Start button. 2. Pipette 175 uL of the low level control solution Irvice into the cuvette. COMMENT : Test passed! rvice DILUTION : 1.0 rvice 3. Press the Start button on the analyzer again. rvice Particle Category D. erator erator RBC Passed In the software, the system displays a message rvice WBC Passed 11 4. whether the test passed or failed. rvice MESSAGE 4 rvice rvice Quality control test (Low level) Spin passed. (50) 5. Select OK. rvice rvice Service 6. The software will prompt you to repeat the steps again to load the high level of control 5 Modified Vi material. OK No 02 No No No 03 No No No 04 No No No 05 No No No Template Effective Date: 2 Jan 2025| HILS 2223 2 Effective Date: 31 Jan 2023| HOOD05162003328177 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Atellica® UAS 60 SIEMENS Healthineers Quality Control Job Aid Reviewing QC Results 2 SAMPLE LIST: 15 samples SELECTED SAMPLE : Date&Time 4 ID Name Sed Chem Eval LIS Sediment m DATE : 6/9/2016 9:46:57 AM 6/6/2016 2:09:43 PM 00102 QC_HIGH N/A 15/15 No Operator ID : 00101 Quality control results can be viewed in the Database. 6/6/2016 2:24:31 PM U0001-1 Comer, Luz N/A 15/15 No Service NAME : QC LOW 3 6/6/2016 2:25:45 PM U0001-2 Lite, Jennifer N/A 15/15 No Service COMMENT : Test passed! DATABASE 6/6/2016 3:04:03 PM U0005-1 Sussete, Bob N/A 15/15 No Service 6/6/2016 3:32:05 PM U0015-1 Brown, Joyce N/A 15/15 No Service DILUTION : 1.0 1. The two levels of QC are labeled as QC Low and QC 1 6/6/2016 3:32:55 PM 4 U0016-1 Wyle, Jer N/A 15/15 No Service Particle Category p/d Limit (p/pl) PAD Category Result Unit 6/9/2016 9:46:57 AM 00101 QC_LOW N/A 15/15 No Operator 6/9/2016 9:47:16 AM 00102 QC_HIGH N/A 15/15 No Operator RBC Passed 3.5 0 .. 15 6/9/2016 9:51:33 AM U0081-1 Bob, Piper + N/A 15/15 No Service WBC Passed 11.2 0 .. 15 QUALITY CONTROL High. 6/9/2016 2:44:28 PM U0096-1 Modtland, Mich N/A 15/15 No Service 6/9/2016 2:49:01 PM U0100-2 Swam, Jennifer N/A 15/15 No Service Lot number : 47441 6/9/2016 2:54:58 PM U0106-2 Love, John N/A 15/15 No Service Liquid type : Quantimetrix Dip and Spin 6/9/2016 3:19:09 PM U0110-1 Kiger, Jenna N/A 15/15 No Service Expiration date: 11/30/2016 + + + + 2. In the Sediment column, a green checkmark indicates 6/9/2016 3:28:02 PM U0114-1 Gonzalez, Evert N/A 15/15 No Service INFO 6/9/2016 3:29:32 PM U0115-2 Squier, Emma N/A 15/15 No Service + the QC has passed. IMAGE LIST: 15 images Image For review Checked Modified Valid 01 No No No 02 No No No 3. The Comment field also displays the failure or 03 No No No 04 No No No success of each test. 05 No No No 06 No No No 07 No No No 08 No No No V 4. Select Quality Control to view the low and high 09 No No No 10 No No No V 11 No No No diagrams. 12 No No No 15 SELECT ALL DELETE MODIFY FILTER OFF GALLERY COMMENT WORKLIST OUTPUTS LIST VALIDATE EXIT Not ready Operator Particle classes: 17 9:12:45 AM *Procedure is continued on next slide Template Effective Date: 2 Jan 2025| HILS 2223 3 Effective Date: 31 Jan 2023| HOOD05162003328177 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Atellica® UAS 60 SIEMENS Healthineers Quality Control Job Aid Reviewing QC Results, continued 5 Settings Low Diagrams High Diagrams 6 LABELS ON Last weeks o . Between 2/ 8/2022 12:00:00 AM 3/ 8/2022 - 11:59:59 PM- SHOW Lot number 135922 55252 Show Average and 80 lines The evolution of the results over time are visualized on Levey- Liquid type Quantimetrix Dip and Spin Quantinetrix Dip and Spin Quantimetrix Dip and Spin DATABASE Expiration date 1/31/2023 8/31/2022 3/8/2022 Find - last meas. date 3/8/2022 - 3/8/2022 3/8/2022 - 3/8/2022 3/8/2022 - 3/8/2022 Jennings charts in the Low and High diagrams tabs. Measure count 7 RBC limits (p/p4) 5 160 0 150 RBC average (p/pl) 99.7 33.7 RBC 50 (p/w4) 11.5 43 QUALITY CONTROL 24.0 RBC CV (%) 11.6 71.1 18.9 WBC limits (p/34) 15 100 20 .50 5. Select the radio buttons and text boxes at the top of the WBC average (p/l) 12.7 125 WBC SD (p/pl) 3.0 9.0 INFO WBC CV (%) 70.7 screen to view specific time periods. High - RBC High - WBC 160 152 144 6. Select the Labels On button to toggle the display of the 136 128 120 exact result value captions. 112 104 96 00 PH 7. Check or uncheck the boxes in the tabular summary to 72 56 show or hide any given control solution lot. 16 10:50:00 1:06:00 0:45:00 10.50.00 1:10:00 33 START QC PRINT EXPORT EXIT Online Service Particle classes: 13 Recognition threads: waiting 0 Waste bin: 38 12:58:17 PM Template Effective Date: 2 Jan 2025| HILS 2223 4 Effective Date: 31 Jan 2023| HOOD05162003328177 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Atellica® UAS 60 SIEMENS Healthineers Quality Control Job Aid Managing New Lots of QC Settings Low Diagrams High Diagrams Low level Lots Low level Lot settings (p/p1) 2 Use Expiration date Lot number iquid type Lot number: 1. In the Quality Control settings menu, select Liquid type: 3 New below the Low or High level solution list. Expiration date: 12/12/2022 4 RBC min: 2. Enter the lot number in the Lot number text RBC max: 5 field. WBC min: WBC max: 1 6 3. Chose the type of control from the Liquid type NEW MODIFY DELETE SELECT CANCEL SAVE drop-down list. High level Lots High level Lot settings (p/p1) Use Expiration date Lot number Liquid type Lot number: 4. From the package insert, enter the Expiration Liquid type: date. Expiration date: 12/12/2022 RBC min: 5. From the package insert, enter the RBC and RBC max: WBC minimum and maximum expected limits. WBC min: WBC max: 6. Select Save. NEW MODIFY DELETE SELECT CANCEL SAVE Template Effective Date: 2 Jan 2025| HILS 2223 5 Effective Date: 31 Jan 2023| HOOD05162003328177 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com Template Effective Date: 2 Jan 2025| HILS 2223 6 Effective Date: 31 Jan 2023| HOOD05162003328177 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025

  • point of care
  • poc
  • urinalysis
  • atellica