Atellica® Solution SCI to CI Analyzer with Sample Handler Bridge Self-Guided Practical Exercises

Atellica® Solution SCI to CI Analyzer with Sample Handler Bridge Self-Guided Practical Exercises

Perform this hands-on exercise after completing or in conjunction with the recommended PEPconnect Activities in this Learning Path. We recommend performing the hands-on exercises under the guidance of a trained operator (Key Operator/Technical Application Specialist). The estimated time of completion for this hands-on exercise is approximately 2 hours. 

SIEMENS Healthineers Atellica® Solution SCI to CI Analyzer with Sample Handler Bridge Self-Guided Practical Exercises Perform the hands-on exercises below after completing or in conjunction with the recommended PEPconnect Activities in this Learning Path. We recommend performing the hands-on exercises under the guidance of a trained operator (Key Operator/Technical Application Specialist). When needed, please reference the PEPconnect Online Training Videos and the Online Help (OLH) on your system. The estimated time of completion for this hands-on exercise is approximately 2 hours. To fully benefit from the upcoming exercises, it is recommended to have day needs configured and available on your system. System Overview 1. Locate the System Status Map on the Home Screen. a. What is the serial number for the Sample Handler? __________________________________________________________________ b. What is the status of the Sample Handler? __________________________________________________________________ c. What is the serial number for the CI Analyzer? __________________________________________________________________ d. What is the status of the CI Analyzer? __________________________________________________________________ 2. Click on the CI Analyzer in the System Status Map. a. Which buttons would be used to open the front covers? ________________________________________________________________________ T18002.007 Page 1 of 9 Effec ve Date: 12/16/2024 ti SIEMENS Healthineers b. Which bu on would be used to open the back covers? tt ________________________________________________________________________ c. What status must the instrument be in to open the covers? ________________________________________________________________________ Supply and Reagent Management 1. Which ti le is used to iden fy reagents that are required to be loaded? ti ______________________________________________________________________________ 2. Navigate to the Reagent Overview screen and filter to view Chemistry reagents only. a. Select a Chemistry reagent and unload. While the reagent is unloading, access the Reagent Loading screen. Watch the screen as the reagent is unloading. At what point can you open the reagent drawer? ________________________________________________________________________ b. Open the Chemistry reagent drawer, move the reagent to another posi on and ti close the drawer. Does it ma er what direc on the pack is loaded? tt ti _______________________________________________________________________ 3. Navigate to the Reagent Overview screen and filter to view Immunoassay reagents only. a. Select an Immunoassay primary reagent and unload. Navigate to the Reagent Loading screen. What indicates the reagent is safe to be removed in the so ware? ft ________________________________________________________________________ b. What indicates the reagent is safe to be removed on the system? ________________________________________________________________________ c. What is the maximum amount of me the IM primary reagent door can be ti opened before needing to remix the reagents? ________________________________________________________________________ T18002.007 Page 2 of 9 Effec ve Date: 12/16/2024 ti SIEMENS Healthineers d. Remove the Immunoassay reagent and reload in another posi on. Close the ti reagent drawer. 4. Select the Supply Needs Tile. a. Are there Supplies listed with needs? ________________________________________________________________________ b. Review one supply listed on the screen. Under the Status column, what is the status of this supply? ________________________________________________________________________ 5. Select View All Supplies at the top of the screen. a. Are there separate drop-down boxesfor Chemistry Supplies vs Immunoassay Supplies? ________________________________________________________________________ b. Under the guidance of a trained operator, replace the System Fluid with the lowest volume. c. What should be done to prevent a vacuum from forming inside the system fluid containers? ________________________________________________________________________ d. If the cuve e bin status is empty, what must be selected in the so ware to load tt ft cuve tt es a er filling the bin? ft ________________________________________________________________________ e. Does the system use the front p trays or the back p trays for sample ti ti processing? ________________________________________________________________________ f. If the p drawer LED is lit, should the drawer be opened? ti __________________________________________________________________ T18002.007 Page 3 of 9 Effec ve Date: 12/16/2024 ti SIEMENS Healthineers g. Under the guidance of a trained operator, replace ps. How does the so ware ti ft know the ps have been replaced? ti ________________________________________________________________________ h. Prac ce emptying the waste. ti i. What needs to be placed into the Pretreatment pack? ________________________________________________________________________ j. Select Replace Item within the IMT A-LYTE Mul sensor sec on. What state must ti ti the analyzer need to be in to replace the IMT Mul sensor? (Do not replace the ti Mul sensor). ti ________________________________________________________________________ Quality Control 1. From the Navigator, select QC Orders. a. What is one reason a QC order would need to be ordered manually? ________________________________________________________________________ b. Manually create a QC order for a current calibrated reagent onboard your system. Load the material onto your system. Confirm the QC is running on the Worklist. Calibra on ti 1. From the Home Screen, select the Calibra on Due Tile. ti a. What me is your system scheduled to order calibra ons? When will a warning ti ti be triggered? __________________________________________________________________ b. Select an Assay listed in the sec on “Calibra on Required with Needs”. What is ti ti the current order status and ti me for this assay? __________________________________________________________________ T18002.007 Page 4 of 9 Effec ve Date: 12/16/2024 ti SIEMENS Healthineers c. If the status is listed as “Scheduled” or “Place Order” place the order by selec ng ti Order on the right-hand side. d. Once the Assay is in an Ordered status, fulfill the need based off the “Material Status”. Print the barcode for the material needed and load onto the system. e. Review the Calibra on Result Details once completed. Was this calibra on ti ti automa cally accepted? Why or why not? ti ________________________________________________________________________ Sample Processing 1. Locate samples that are permi ed to use for training in your laboratory. Navigate to tt Pa ent Orders. ti a. Provide an instance when crea ng a pa ent order manually may be necessary? ti ti ________________________________________________________________________ b. Create a pa ent order at the instruc on of a trained operator using ready to use ti ti reagents that are onboard your system. Make edits to the tests ordered including a dilu on, replicate, and a specific reagent lot. ti c. If necessary, print the barcode. Next, place the order and load the sample onto the Sample Handler d. Navigate to the Worklist, filter for pa ent samples only. What is the status of ti your sample? ________________________________________________________________________ e. Select the sample, on the right-hand side of the worklist what sample func ons ti are available to you? ________________________________________________________________________ f. Review the results of the pa ent sample, are there flags associated? If so, what ti is the assay and what is the flag? ________________________________________________________________________ T18002.007 Page 5 of 9 Effec ve Date: 12/16/2024 ti SIEMENS Healthineers Maintenance 1. From the Home Screen, select the Maintenance le. Filter the frequency to view the ti Daily Maintenance ac vi es. ti ti a. Select the ac vity, “Inspec ng and Cleaning the CH Washer Probes”. Review the ti ti procedure details, what are you inspec ng the washer probes for? If needed, ti what supplies are used to clean the washer probes? ________________________________________________________________________ ________________________________________________________________________ b. Does the operator need to navigate to Operator Diagnos cs to perform the daily ti manual maintenance ac vity? ti __________________________________________________________________ c. Under the guidance of a trained operator, perform Inspec ng and Cleaning the . CH Washer Probes. 2. At the bo om of your Maintenance screen, select the All Ac vi es bu on. Filter the tt ti ti tt frequency to view CI Weekly Maintenance Ac vi es. ti ti a. Select the ac vity “Checking the CH Lamp Coolant”. Review the procedure ti details, can the Lamp Coolant be refilled while the system is processing? ________________________________________________________________________ b. Under the guidance of a trained operator, perform Checking the Lamp Coolant. c. Select the ac vity “Cleaning the Exterior of the IM Reagent Probe”. Review the ti procedure details, what should be used to clean the IM Reagent Probe? ________________________________________________________________________ d. Under the guidance of a trained operator, perform Cleaning the Exterior of the IM Reagent Probe. 3. At the bo om of your Maintenance screen, select the All Ac vi es bu on. Filter the tt ti ti tt frequency to view CI Monthly Maintenance Ac vi es. ti ti T18002.007 Page 6 of 9 Effec ve Date: 12/16/2024 ti SIEMENS Healthineers a. Select the ac vity “Cleaning the Exterior of the IM Aspirate Probes”. Review the ti procedure details, what should be used to clean the IM Aspirate Probes? _________________________________________________________________ b. Under the guidance of a trained operator, perform Cleaning the Exterior of the IM Aspirate Probes. c. Select the ac vity “Inspec ng and Cleaning the CH Probes, Wash Sta ons, and ti ti ti Mixer Impellers”. Review the procedure details, what should be used to clean the CH Probes, Wash Sta ons, and Mixer Impellers? ti __________________________________________________________________ d. Under the guidance of a trained operator, perform Inspec ng and Cleaning the ti CH Probes, Wash Sta ons, and Mixer Impellers. ti e. What must be done to the CH Dilu on Probe to access it for cleaning? ti __________________________________________________________________ f. Select the ac vity “Inspec ng and Cleaning the IM Probe Rinse Sta on”. Review ti ti ti the procedure details, what should be used to clean the Inspec ng and Cleaning ti the IM Probe Rinse Sta on? ti __________________________________________________________________ g. Under the guidance of a trained operator, perform Inspec ng and Cleaning the ti IM Probe Rinse Sta on. ti h. Select the ac vity “Cleaning the CI Fan Filters”. Review the procedure details, ti how many fans filters need to be cleaned? __________________________________________________________________ i. Under the guidance of a trained operator, perform Cleaning the CI Fan Filters. j. Select the ac vity “Replacing CH Dilu on Cuve e Segments”. Review the ti ti tt procedure details, how o en should the CH Dilu on Segments be replaced? ft ti __________________________________________________________________ k. What needs to be removed to replace the segments? T18002.007 Page 7 of 9 Effec ve Date: 12/16/2024 ti SIEMENS Healthineers l. Select the ac vity “Replacing the CH Source Lamp”. Review the procedure details, ti how o en should the CH Source Lamp be replaced? ft __________________________________________________________________ Troubleshoo ng ti 1. Navigate to Online Help. Search Shu ng Down the Atellica CI Analyzer. tti a. Does the Sample Handler have its own power switch? ________________________________________________________________________ b. Which systems power switch should be turned off first? __________________________________________________________________ T18002.007 Page 8 of 9 Effec ve Date: 12/16/2024 ti SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com T18002.007 Page 9 of 9 Effec ve Date: 12/16/2024 ti

  • atelica
  • attellica
  • attelica