Atellica® CH Analyzer Supply and Reagent Management Assessment Version 1.26 and Above

Atellica® CH Analyzer Supply and Reagent Management Assessment Version 1.26 and Above

This assessment includes the objectives covered in the Atellica® CH Analyzer Supply and Reagent Management topic.

Continue Continue Continue Assessment Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 Atellica® CH Analyzer Supply and Reagent Management Assessment This assessment covers the content in the Atellica® CH Analyzer Supply and Reagent Management topic. Welcome Objectives It is recommended that the learning artifacts in the Supply and Reagent Management topic for the Atellica® CH Analyzer are completed prior to taking this assessment. The objectives covered in these learning artifacts are: Monitor the status of the supply and reagent inventories Load and unload supplies, consumables, and reagent Load and unload reagent packs Replace supplies Text with Image Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com Disclaimer Assessment This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate. You may repeat the assessment as many times as needed. Start Assessment Six Six Four Two How many reagent packs can be loaded onto the Atellica® CH Analyzer at one time? Question 1 of 10 Select the best answer. Multiple Choice Question Incorrect The Atellica® CH Analyzer can load more than two reagent packs at a time. Incorrect The Atellica® CH Analyzer can load more than four reagent packs at a time. Correct QC Needs Supply Needs Reagent Needs Which tile in the Atellica® CH Analyzer software will alert the operator that the system fluids need to be changed? Question 2 of 10 Select the best answer. Multiple Choice Question Incorrect The Reagent Needs tile will not alert the operator that the system fluids need to be changed. Correct The QC Needs tile will not alert the operator that the system fluids need to be changed. Incorrect The system will not allow the operator to open the reagent tray lid while the reagent loader is loading a reagent pack The reagent loader continues to load the reagents into their designated compartments The reagent loader will stop and the reagent tray will move back into the loading area What happens if the reagent tray lid is opened while the reagent loader is loading a reagent pack onto the system? Question 3 of 10 Select the best answer. Multiple Choice Question Incorrect The reagent loader does not continue to load the reagents into their designated compartments. Correct The reagent tray lid can be opened while the reagent loader is loading a reagent pack. Incorrect 2-8ºC 2-8ºC 0-2ºC 8-10ºC At which temperature should the 1-L pretreatment bottle be stored once it is opened? Question 4 of 10 Select the best answer. Multiple Choice Question Incorrect The 1-L pretreatment bottle should not be stored at 8-10ºC. Incorrect The 1-L pretreatment bottle should not be stored at 0-2ºC. Correct The pretreatment pack is located behind the IMT fluids The pretreatment pack is located behind the IMT fluids The pretreatment pack is located near the wash probes The pretreatment pack is located near the reagent compartment lids Where is the Pretreatment Pack located on the Atellica® CH Analyzer? Question 5 of 10 Select the best answer. Multiple Choice Question Incorrect The pretreatment pack is not located near the reagent compartment lids Incorrect The pretreatment pack is not located near the wash probes. Correct The system is configured to automatically send reagent packs to the reagent tray when the packs are empty or expired The system is configured to automatically send reagent packs to the reagent tray when the packs are empty or expired Reagent packs cannot be removed manually by the operator The operator must check the reagent tray before each run to view if there are reagents waiting to be removed from the system Which of the following is TRUE regarding unloading reagent packs from the Atellica® CH Analyzer? Question 6 of 10 Select the best answer. Multiple Choice Question Incorrect To view the reagents that are waiting to be removed, the operator can navigate to Reagent Loading screen. Incorrect Reagent packs can be removed manually by the operator. Correct With special reagent water With special reagent water With 10% bleach With water only Which solution is used to rinse empty 180-mL pretreatment bottles and caps? Question 7 of 10 Select the best answer. Multiple Choice Question Incorrect Water is not used to rinse empty 180-mL pretreatment bottles and caps. Incorrect 10% bleach solution is not used to rinse empty 180-mL pretreatment bottles and caps. Correct The new IMT fluid container can be scanned using the module display or the handheld barcode scanner The new IMT fluid container can be scanned using the module display or the handheld barcode scanner The new IMT fluid container can be scanned using the module display or the handheld barcode scanner An IMT fluid container can be refilled The same IMT fluid container can be loaded multiple times Which of the following is TRUE regarding replacing the IMT fluids on the Atellica® CH Analyzer? Question 8 of 10 Select the best answer. Multiple Choice Question Incorrect Do not load the same IMT fluids container multiple times. Removing and reloading an IMT fluid container can cause the punctured membrane to leak. Incorrect Do not refill an IMT fluid container. Refilling a container can cause contamination. Correct Reagent Overview Reagent Overview Supply Needs System Status On which screen in the software can the operator check the status of the reagent packs that are onboard the CH Analyzer? Question 9 of 10 Select the best answer. Multiple Choice Question Incorrect The System Status screen displays the status of each module. Incorrect The Supply Needs screen displays the status of the system fluids. Correct The cap on the system fluid containers should be tightened when removing the containers from the system The cap on the system fluid containers should be tightened when removing the containers from the system The fluid containers can be loaded into any position in the system fluid drawer The system fluids cannot be replaced during system processing Which of the following is TRUE regarding replacing system fluids on the Atellica® CH Analyzer? Question 10 of 10 Select the best answer. Multiple Choice Question Incorrect The system fluids can be replaced during system processing because the system will use fluid from the reservoir. Incorrect The fluid containers are keyed to fit only in the designated drawer position. Correct Review Review Retry Assessment Results %Results.ScorePercent%% %Results.PassPercent%% Continue YOUR SCORE: PASSING SCORE: Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course. Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. You have completed the Atellica® CH Analyzer Supply and Reagent Management Assessment. Completion HOOD05162003277176 | Effective Date: 10-JUN-2022 1.1 Welcome 1.2 Text with Image 1.3 Disclaimer 1.4 Assessment 1.10 Multiple Choice Question 1.11 Multiple Choice Question 1.12 Multiple Choice Question 1.13 Multiple Choice Question 1.14 Multiple Choice Question 1.16 Completion

  • attelica
  • attellica
  • atelica