Atellica® 1500 Automated Urinalysis Analyzer System Preparation Practical Exercise

Atellica® 1500 Automated Urinalysis Analyzer System Preparation Practical Exercise

Atellica™ UAS 800 Analyzer: Log into the software. Load and register cuvettes.

CLINITEK Novus® System: Load reagent cassette. Empty and refill the rinse bottle. Empty the card waste drawer.

AtellicaTM 1500 Automated Urinalysis Analyzer SIEMENS System Preparation Practical Exercise Healthineers Objectives: Helpful Hints: • Log into the Atellica™ UAS 800 Analyzer This exercise involves preparing the system for use, therefore, it is • Load cuvettes onto the Atellica™ UAS 800 Analyzer recommended to select a time that is convenient with your laboratory workflow. • Register cuvettes on the Atellica™ UAS 800 Analyzer • Load reagent cassette onto the CLINITEK Novus® Analyzer • Empty and refill the rinse bottle on the CLINITEK Novus® Analyzer • Empty the card waste drawer on the CLINITEK Novus® Analyzer Supplies Needed: • Atellica™ UAS 800 Analyzer cuvettes • CLINITEK Novus® Analyzer reagent cassette • CLINITEK Novus® Rinse Additive • Deionized water • Personal Protective Equipment *Not available for sale in the U.S. Product availability varies by country. 1 IM HOOD05162002594191 © Siemens AG 2013. All rights reserved. Page 1 Hardware Overview Effective Date: 6/16/2017 SIEMENS System Preparation – Atellica™ UAS 800 Analyzer Healthineers Logging on 1. Press the power button on the analyzer. 2. Turn on the personal computer (PC). 3. When the dialog box appears, type in login name and SIEMENS Healthineers password. Atellica UAS 800 4. Select OK. Automated Urine Sediment Analyzer Username Password Logging off Select Logout in the Menu bar. Ok 1. Version 4.0.72 | @ 2015 Siemens AG 2 © Siemens AG 2013. All rights reserved. Page 2 SIEMENS System Preparation – Atellica™ UAS 800 Analyzer Healthineers Loading cuvettes CE IVD 1. Open the front cover. CE [IVD ] CE [IVD] CE LIVD LOT 2. Rotate wing screw to the left on top of cuvette carousel. 2019-04-23 2 2019-04-23 LOT 160429516 160429512 2 2019-04-23 LOT] 160429616 LOT 2019-04-23 160429516 Atellica UAS 800 3. Lift and remove top of cuvette carousel. e3 Atellica URS 800 50 Quvettes Eso Quettes Atellica UAS 800 Atellica uns Co 4. Open cuvettes carton and remove registration card. EYS Ouettes 5. Load a single cuvette cartridge into the carousel. A Image of cuvettes carton 6. Turn the carousel clockwise to the next empty slot. 7. Load cuvette cartridges until the carousel is full. 8. Replace top on carousel and tighten wing screw. 9. Remove tape at the bottom of each cuvette cartridge. 10. Close the front cover. OO Note: Cuvettes must be registered with the system before processing samples. 3 © Siemens AG 2013. All rights reserved. Page 3 SIEMENS System Preparation – Atellica™ UAS 800 Analyzer Healthineers Cuvette Registration (44) Registering cuvettes You must register cuvettes before using them on the analyzer. 1. Select the Measure icon. Remove the registration card from the front of the cuvette box and 2. Select the Cuvette Reg button. then click the green check button. Insert the cuvette registration card into the barcode scanner slot 3. Press the check. when prompted. Insert the registration card in the sampling area with barcode . To cancel registration click the red X button. 4. facing the reader. 3 X 5. Select the check to return to the Measure screen. Barcode scan successful. (69) Cuvette registration complete. 5 Cuvette Reg 4 © Siemens AG 2013. All rights reserved. Page 4 System Preparation – CLINITEK Novus® Analyzer SIEMENS Healthineers Loading reagent cassette 1. Select System. 2. Select Load & Unload. 3. Select Yes. 4. Open the front cover. 5. Unlock and open the cassette door. 6. Remove the cassette. 7. Load the new cassette. 8. Close and lock the cassette door. 9. Close the front cover. Note: The system reads the lot number and expiration date of the reagent cassette when the front cover is closed. 5 © Siemens AG 2013. All rights reserved. Page 5 SIEMENS System Preparation – CLINITEK Novus® Analyzer Healthineers Empty and fill rinse bottle 1. Remove racks from the sample rack handler. 2. Press the latch forward and pull the rinse drawer out of the slot. 3. Turn the bottle cap counter clockwise to remove it. 4. Empty the rinse solution according to your facility’s disposal guidelines. 5. Fill the rinse bottle with 1000 mL of distilled or deionized water. 6. Add 2 mL of CLINITEK Novus Rinse Additive. 7. Gently swirl the bottle six times. 8. Replace the cap and turn it clockwise, finger tight. 9. Slide the rinse drawer into the slot until it is latched. 10. Select System. 11. Select Prime Pump. 6 © Siemens AG 2013. All rights reserved. Page 6 System Preparation – CLINITEK Novus® Analyzer SIEMENS Healthineers Empty card waste drawer 1. Remove racks from the sample rack handler. 2. Press the latch forward and pull the card waste drawer out of the slot. 3. Empty the cards according to your facility’s disposal guidelines. 4. Remove and clean the internal liner with isopropyl alcohol. 5. Replace the internal liner. 6. Slide the card waste drawer into the slot until it is latched. 7 © Siemens AG 2013. All rights reserved. Page 7 Hardware Overview System Preparation Review Questions Review Questions 1. After loading cuvettes onto the Atellica™ UAS 800 analyzer, which screen do you need to access to register cuvettes? 2. On the CLINITEK Novus® analyzer, which screen provides access to the Load & Unload button for loading reagent cassettes? 3. Which task must be performed after filling the rinse bottle on the CLINITEK Novus® analyzer? 8 © Siemens AG 2013. All rights reserved. Page 8 Software Overview System Preparation Review Questions Review Questions Answer Key 1. Measure screen 2. System screen 3. Prime pump 9 © Siemens AG 2013. All rights reserved. Page 9