Atellica® 1500 Automated Urinalysis System Introduction
An introductory overview of the Atellica 1500 Automated Urinalysis System focusing on key features and benefits of the system and consumables. Showcases routine operations and results management, and gives insight into maintenance procedures and quality control.
\\vmware-host\Shared Folders\von PS\Siemens Healthineers\sh_logo_RGB.wmf Unrestricted © Siemens Healthineers 2022 Atellica 1500 Automated Urinalysis System (Not available for sale in the U.S. Product availability varies by country.) HOOD05162003225091 Unrestricted © Siemens Healthineers 2021 Atellica 1500 Automated Urinalysis System (Not available for sale in the U.S. Product availability varies by country.) Atellica® 1500 Automated Urinalysis System Atellica 1500 Automated Urinalysis System combines urine chemistry and urine sediment analyzers Atellica® UAS 800 Urine Sediment Analyzer* CLINITEK Novus® Automated Urine Chemistry Analyzer Atellica® 1500 Automated Urinalysis System* Atellica® 1500 Automated Urinalysis System Welcome Atellica® 1500 Automated Urinalysis System Introduction System Overview Clinical Excellence System Overview Exterior Interior Reagent Consumables Routine Operations Power on the System Prepare the System Prepare Patient Samples Run Patient Samples View Patient Results Results Management Filter Patient Results View Patient Results Validate Patient Results Edit Particle Tags Maintenance Daily Tasks Weekly, Monthly & Periodic Tasks Quality Control Calibrating the CLINITEK Novus Quality Control Testing – CLINITEK Novus Quality Control Testing – Atellica UAS 800 Final Assessment Agenda Agenda Agenda Introduction Basic Information System Overview Clinical Excellence System Overview Exterior Interior Reagent Consumables Routine Operations Power on the System Prepare the System Prepare Patient Samples Run Patient Samples View Patient Results Results Management Filter Patient Results View Patient Results Validate Patient Results Edit Particle Tags Maintenance Daily Tasks Weekly, Monthly & Periodic Tasks Quality Control Calibrating the CLINITEK Novus Quality Control Testing – CLINITEK Novus Quality Control Testing – Atellica UAS 800 Final Assessment Introduction System Overview Clinical Excellence Introduction Introduction Basic Information System Overview Clinical Excellence Atellica 1500 UA Optimizes Operational Efficiency Introduction Loading Capacity: One time loading capacity = 100 samples Throughput: 106 – 238 samples/hr Minimum Sample Volume: 2.6 mL “Small footprint” Lab space saving: 125 cm * 70 cm “Intelligence built in” Automatically detects tube caps Automatically detects sample volume & level Flexible reflexing rules Enable customers to manage testing and results in customizable settings Loading Capacity: One time loading capacity = 100 samples Throughput: 106 – 238 samples/hr Minimum Sample Volume: 2.6 mL “Small footprint” Lab space saving: 125 cm * 70 cm “Intelligence built in” Automatically detects tube caps Automatically detects sample volume & level Flexible reflexing rules Enable customers to manage testing and results in customizable settings System Overview Overview Introduction System Overview Atellica 1500 UA Optimizes Operational Efficiency Loading Capacity: One time loading capacity = 100 samples Throughput: 106 – 238 samples/hr Minimum Sample Volume: 2.6 mL “Small footprint” Lab space saving: 125 cm * 70 cm “Intelligence built in” Automatically detects tube caps Automatically detects sample volume & level Flexible reflexing rules Enable customers to manage testing and results in customizable settings Broad menu for both chemistry and sedimentation RBC WBC WBC clumps Squamous EC Nonsquamous EC Bacteria Bacteria cocci Bacteria rods Crystals Hyaline cast Pathological cast Yeast Sperm Mucus SG Clarity Bilirubin Glucose Color Protein Albumin Ketone Creatinine pH Occult blood Nitrite Urobilinogen Leukocyte ACR, PCR Clinical Excellence Investment Confidence Operational Efficiency Designed to resemble manual microscopy The Atellica UAS 800 system counts bacteria subcategories (rod and cocci) providing valuable information for practitioners The CLINITEK Novus analyzer provides ACR testing* that helps in the detection of early kidney disease. High blood pressure Diabetes The Atellica UAS 800 system counts bacteria subcategories (rod and cocci) providing valuable information for practitioners Designed to resemble manual microscopy 60+ Clinical Excellence Introduction *With CLINITEK Novus PRO 12 cassettes. Not available for sale in the U.S. Clinical Excellence Introduction Clinical Excellence Broad menu for both chemistry and sedimentation Operational Efficiency Investment Confidence Clinical Excellence RBC WBC WBC clumps Squamous EC Nonsquamous EC Bacteria Bacteria cocci Bacteria rods Crystals Hyaline cast Pathological cast Yeast Sperm Mucus SG Clarity Bilirubin Glucose Color Protein Albumin Ketone Creatinine pH Occult blood Nitrite Urobilinogen Leukocyte ACR, PCR Designed to resemble manual microscopy The Atellica UAS 800 system counts bacteria subcategories (rods and cocci) to reduce the need for urine culture. The CLINITEK Novus analyzer provides ACR testing* that helps in the detection of early kidney disease. *With CLINITEK Novus PRO 12 cassettes. Not available for sale in the U.S. Exterior Interior Reagent Consumables System Overview System Overview System Overview Exterior Interior Reagent Consumables Click the Atellica 1500 UA System to toggle back and forth between exterior and interior views. Exterior View Atellica 1500 Exterior & Interior System Overview Atellica 1500 Exterior & Interior System Overview Atellica 1500 Exterior & Interior Interior View CLINITEK Novus Exterior System Overview Touchscreen Display Waste Drawer Rinse Drawer Rack Handler 100 sample capacity Card Waste Drawer Cover Handle Move your pointer over an icon to identify key exterior components of the CLINITEK Novus analyzer. CLINITEK Novus Exterior System Overview CLINITEK Novus Exterior Select the icons to review the exterior components of the CLINITEK Novus. Card Waste Drawer Cover Handle Touchscreen Display Waste Drawer Rinse Drawer Rack Handler - 100 sample capacity Atellica UAS 800 Exterior System Overview Computer Cover Handle Cuvette Waste Drawer Rack Handler Sampling Area Move your pointer over an icon to identify key exterior components of the Atellica UAS 800 analyzer. Atellica UAS 800 Exterior System Overview Atellica UAS 800 Exterior Select the icons to review the exterior components of the Atellica UAS 800. Computer Cuvette Waste Drawer Cover Handle Sampling Area Sampling Area CLINITEK Novus Interior Details System Overview Click each tab to learn about the interior components of the CLINITEK Novus analyzer. 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 6 6 6 6 7 7 7 CLINITEK Novus Interior Details System Overview CLINITEK Novus Interior Details Click each tab to review the interior details of the CLINITEK Novus. 1 Easy load CLINITEK Novus 10 or Pro 12 Cassette RFID tagged 14 day onboard stability 450 dry pad capacity 2 Cassette compartment door with moisture gate 3 Pipette with level-sensing technology collects patient sample 4 Pipette dispenses sample onto Reagent Card No strip alignment concerns No strip jam 5 LED Light illuminates test pad and CCD camera captures images 6 Refractometry method calculates clarity and specific gravity 7 Digital images transferred for results processing Digital images transferred for results processing Refractometry method calculates clarity and specific gravity LED Light illuminates test pad and CCD camera captures images Pipette dispenses sample onto Reagent Card No strip alignment concerns No strip jam Pipette with level-sensing technology collects patient sample Cassette compartment door with moisture gate Easy load CLINITEK Novus 10 or Pro 12 Cassette RFID tagged 14 day onboard stability 450 dry pad capacity Atellica UAS 800 Interior Details System Overview Click each tab to review the interior details of the Atellica UAS 800. 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 6 6 6 6 7 7 7 7 7 Atellica UAS 800 Interior Details System Overview Atellica UAS 800 Interior Details Click each tab to review the interior details of the Atellica UAS 800. 1 Cuvette holder carousel 2 Pipette aspirates sample and mixes 4 times to resuspend particles without introducing air 3 Front cuvette guide where patient sample is dispensed; cuvette then moved to centrifuge 4 Cuvette centrifuged to create sediment monolayer 5 Rear cuvette guide transfers cuvette from centrifuge to microscope location: Microscope with 400x magnification (not shown) Digital camera uses 2-step focusing to capture 15 sediment images (not shown) 6 Neural network based real-time image processing 7 Digital images captured with automatic particle identification. Optional manual view mode available. Digital images captured with automatic particle identification. Optional manual view mode available. Neural network based real-time image processing Rear cuvette guide transfers cuvette from centrifuge to microscope location: Microscope with 400x magnification (not shown) Digital camera uses 2-step focusing to capture 15 sediment images (not shown) Cuvette centrifuged to create sediment monolayer Front cuvette guide where patient sample is dispensed; cuvette then moved to centrifuge Pipette aspirates sample and mixes 4 times to resuspend particles without introducing air Cuvette holder carousel CLINITEK Novus Pro 12 cassette with albumin-to-creatinine ratio helps detect early kidney disease. Table with 5 columns and 2 rows CLINITEK Novus PRO 12 Cassette Albumin Albumin-to-creatinine ratio Bilirubin Clarity Color Creatinine Glucose Ketone Leukocyte esterase Nitrite Occult blood pH Protein Protein-to-creatinine ratio Specific gravity Urobilinogen Table with 3 columns and 2 rows CLINITEK Novus 10 Cassette Bilirubin Clarity Color Glucose Ketone Leukocyte esterase Nitrite Occult blood pH Protein Specific gravity Urobilinogen 450 Tests per Cassette RFID tag under the label Measurement Technology Digital camera determines test pad color changes in entire RGB color spectrum Color correction applied for improved accuracy Three-Way Humidity Protection Reagent cards stored in closed cassette with desiccant pack Cassette sits inside a well-sealed compartment Leukocyte pad checked by software System Overview CLINITEK Novus Reagent CLINITEK Novus Reagent System Overview CLINITEK Novus Reagent CLINITEK Novus Analyzer with CLINITEK Novus Cassettes Measurement Technology Digital camera that measures the color changes in the entire RGB color spectrum and applies color correction for improved accuracy Comprehensive Humidity Protection Cards inside closed cassette with desiccant pack Cassette sits inside well-sealed compartment in system Leukocyte pad checked by software before each test Menu CLINITEK Novus 10 Cassette Bilirubin Clarity Color Glucose Ketone Leukocyte esterase Nitrite Occult blood pH Protein Specific gravity Urobilinogen 450 Tests per Cassette RFID tag under the label Table with 4 columns and 3 rows Auto-reported Categories 11 Major Categories: Sub-categories: Bacteria Crystals Hyaline cast Mucus Nonsquamous EC Pathological cast RBC Sperm Squamous EC WBC Yeast Bacteria cocci Bacteria rods WBC clumps Measurement Technology Digital microscopy Dual-focus, high-resolution digital camera generates clear images Real-time image capture Atellica UAS 800 Consumables System Overview 50 cuvettes per cartridge for a total onboard capacity of 600 cuvettes Atellica UAS 800 Consumables System Overview Atellica UAS 800 Consumables Atellica UAS 800 Analyzer Measurement Technology Digital microscopy imaging Dual-focusing mechanism to generate clear images Real-time image capture function Menu Auto-reported Categories 11 Major Categories: Bacteria Crystals Hyaline cast Mucus Nonsquamous EC Pathological cast RBC Sperm Squamous EC WBC Yeast Sub-categories: Bacteria cocci Bacteria rods WBC clumps 50 cuvettes per cartridge for a total onboard capacity of 600 cuvettes Power on the System Prepare the System Prepare Patient Samples Run Patient Samples View Patient Results Routine Operations Routine Operations Routine Operations Power on the System Prepare the System Prepare Patient Samples Run Patient Samples View Patient Results Power on the System Routine Operations Press the power button on Atellica UAS 800 side of the system* Turn on the computer Login using your credentials Verify status bar displays “Online” * CLINITEK Novus system must always remain on in order to hydrate SG well Power On the System Routine Operations Power on the System Press the power button on Atellica UAS 800 side of the system* Turn on the computer Login using your credentials Verify status bar displays “Online” * CLINITEK Novus system must always remain on in order to hydrate SG well Check remaining test pads available and replace cassette if necessary To load new CLINITEK Novus 10 or Pro 12 Cassette Open front cover of analyzer Select System button Select Load & Unload Select Yes Unlock cassette compartment door Load new cassette Lock cassette compartment door Check remaining cuvettes available, and add cuvette cartridge if necessary If needed, follow these steps to load additional cuvettes: Open front cover of analyzer Rotate wing screw Lift up to remove top of carousel Open cuvette carton and remove registration card Load cuvette cartridge(s) onto carousel Replace the carousel top Rotate the wing screw to lock Close the analyzer front cover If new cuvettes are loaded, follow these steps to register: Click “Measure” on the menu bar Click “Cuvette Reg” Click the check mark A “Scan Barcode” message will appear Insert the registration card into sampling area with barcode facing the barcode reader A “Registration Complete” message will appear Click the green check mark Check the status of the Rinse Bottle and Waste Bottle If necessary, empty and refill the Rinse bottle: Remove rinse drawer from front of system, empty if needed Refill with 1000 mL DI water and add 2 mL of CLINITEK Novus rinse additive If necessary, empty and clean Waste Bottle: Remove waste drawer from front of system and empty liquid waste according to laboratory and biohazard guidelines Prepare the System Routine Operations Prepare the System Routine Operations Prepare the System Check remaining test pads available and replace cassette if necessary To load new CLINITEK Novus 10 or Pro 12 Cassette Open front cover of analyzer Select System button Select Load & Unload Select Yes Unlock cassette compartment door Load new cassette Lock cassette compartment door Routine Operations Apply bar codes to test tubes Place test tubes in rack Confirm a minimum of 2.6 mL patient urine sample in each Load up to 100 samples onto rack handler Prepare Patient Samples Prepare Patient Samples Routine Operations Prepare Patient Samples Apply bar codes to test tubes Place test tubes in rack Confirm a minimum of 2.6 mL patient urine sample in each Load up to 100 samples onto rack handler Routine Operations Confirm Atellica UAS status bar displays Online and Confirm CLINITEK Novus displays Ready On CLINITEK Novus screen, select Start Chemistry analysis will first be performed on CLINITEK Novus system Reflex guidelines can be customized for sediment testing on Atellica UAS 800 Analyzer Measure all samples Measure chemically positive samples Measure based on custom rules Run Patient Samples Run Patient Samples Routine Operations Run Patient Samples Confirm Atellica UAS status bar displays Online and Confirm CLINITEK Novus displays Ready On CLINITEK Novus screen, select Start Chemistry analysis will first be performed on CLINITEK Novus system Reflex guidelines can be customized for sediment testing on Atellica UAS 800 Analyzer Measure all samples Measure chemically positive samples Measure based on custom rules Routine Operations Patient results display on Database screen Chemistry and sediment results are matched based on sample barcode Database screen allows for in-depth results management in either data view, gallery view, or through the image viewing editor: Filter results based on your criteria Review chemistry and sediment results Validate sediment results Edit particle tags Refer to results management section for more detail View Patient Results View Patient Results Routine Operations View Patient Results Patient results display on Database screen Chemistry and sediment results are matched based on sample barcode Database screen allows for in-depth results management in either data view, gallery view, or through the image viewing editor: Filter results based on your criteria Review chemistry and sediment results Validate sediment results Edit particle tags Refer to results management section for more detail Filter Patient Results View Patient Results Validate Patient Results Edit Particle Tags Results Management Results Management Results Management Filter Patient Results View Patient Results Validate Patient Results Edit Particle Tags You can select criteria to filter the sediment and chemistry results Click Database in the Menu bar In the Sample List, click Filter A Filter dialog box appears Select your filter criteria For example, in the Chemical or Sediment Result section, select one or more result attributes Click Apply The matching results display on the Sample List Filter Patient Results Results Management Filter Patient Results Results Management Filter Patient Results You can select criteria to filter the sediment and chemistry results Click Database in the Menu bar In the Sample List, click Filter A Filter dialog box appears Select your filter criteria For example, in the Chemical or Sediment Result section, select one or more result attributes Click Apply The matching results display on the Sample List Patient results display on Database screen Patient chemistry and sediment results are matched based on the sample barcode Select a patient sample from the sample list view Patient results can be viewed in either Data View or Gallery View In Data View, on the Selected Sample List, both chemistry and sediment results are shown In Gallery view, both sediment and chemistry results can be viewed Detailed sediment results of particles per high power field (HPF) Detailed chemistry results of analytes tested Gallery view also allows for use of the Image Viewing Editor (IVE) by double-clicking an image View Patient Results Results Management View Patient Results Results Management View Patient Results Patient results display on Database screen Patient chemistry and sediment results are matched based on the sample barcode Select a patient sample from the sample list view Patient results can be viewed in either Data View or Gallery View In Data view, on the Selected Sample List, both chemistry and sediment results are shown Validate Patient Results Results Management For samples that require manual validation, patient results can be validated in the Database menu In Data view, select a sample from the Sample List Click Validate to validate the sample results When complete, the Validated By column will display the name of the user who validated the sample From the Gallery view: Patient samples can be validated by clicking Validate Patient samples can also be validated from the IVE, by double clicking on an image From the IVE, click Validate to validate the patient sample When complete, the Validated By column will display the name of the user who validated the sample Validate Patient Results Results Management Validate Patient Results For samples that require manual validation, patient results can be validated in the Database menu In Data view, select a sample from the Sample List Click Validate to validate the sample results When complete, the Validated By column will display the name of the user who validated the sample Edit Particle Tags Results Management For any unvalidated patient sample, the particle tags can be changed in the IVE The Quick Particle option is an easy way to work with particle tags, and can be enabled on the IVE screen To add a particle tag: Click the particle type in the list Click the mouse button where you’d like to add the tag To delete a particle tag: Right-click on the tag to remove it Edit Particle Tags Results Management Edit Particle Tags For any unvalidated patient sample, the particle tags can be changed in the IVE The Quick Particle option is an easy way to work with particle tags, and can be enabled on the IVE screen To add a particle tag: Click the particle type in the list Click the mouse button where you’d like to add the tag To delete a particle tag: Right click on the tag to remove it Daily Tasks Weekly, Monthly & Periodic Tasks Maintenance Maintenance Maintenance Daily Tasks Weekly, Monthly & Periodic Tasks Daily Tasks – CLINITEK Novus Maintenance Clean the rack handler Clean the SG Well: Status Log will indicate SG Well cleaning is required System will display Not Ready Select System Select Clean SG Well Place 5.25% bleach in rack position 1, place the rack on the rack handler Select Start Once complete, the system returns the software to the System menu Daily Tasks – CLINITEK Novus Maintenance Daily Tasks – CLINITEK Novus Clean the rack handler Clean the SG Well: Status Log will indicate SG Well cleaning is required System will display Not Ready Select System Select Clean SG Well Place 5.25% bleach in rack position 1, place the rack on the rack handler and select Start Once complete, the system returns the software to the System menu Clean the rack handler Clean the front and rear cuvette guides Empty and clean the cuvette waste bin Disinfecting rinse can be performed through a system shut down: Pour 6 mL of 2% bleach into test tube, place in rack position 1 On the software screen click Shut Down Click the check mark to confirm you want to run a disinfecting rinse Open front cover of the analyzer and carefully remove the front cuvette guide and then close the front cover Click the check mark to confirm you want to run a disinfecting rinse and to start the rinse which will take 3-5 minutes; at the end of the process, the PC and analyzer will shut down Once finished, open the front cover, replace the front cuvette guide, and then close the front cover Maintenance Daily Tasks – Atellica UAS 800 Daily Tasks – Atellica UAS 800 Maintenance Daily Tasks – Atellica UAS 800 Clean the rack handler Clean the front and rear cuvette guides Empty and clean the cuvette waste bin Maintenance Weekly, Monthly & Periodic Table with 3 columns and 4 rows CLINITEK Novus Atellica UAS 800 Weekly Maintenance Clean moisture gate Clean racks and rack pushers Clean racks and rack pushers Monthly Maintenance Clean microscope objective Clean centrifuge door and arm Periodic Maintenance Clean system exterior Clean card platform Clean card grippers Clean rack sensors Clean pad sensor Prime the pump Clean system exterior Clean drip tray Clean barcode reader optic window Clean rack sensors Weekly, Monthly & Periodic Maintenance Weekly, Monthly & Periodic CLINITEK Novus Weekly Maintenance Clean moisture gate Clean racks and rack pushers Periodic Maintenance Clean system exterior Clean card platform Clean card grippers Clean rack sensors Clean pad sensor Prime the pump Atellica UAS 800 Weekly Maintenance Clean racks and rack pushers Monthly Maintenance Clean microscope objective Clean centrifuge door and arm Periodic Maintenance Clean system exterior Clean drip tray Clean barcode reader optic window Clean rack sensors Calibrating the CLINITEK Novus Quality Control Testing – CLINITEK Novus Quality Control Testing – Atellica UAS 800 Calibration & Quality Control Calibration & Quality Control Calibration & Quality Control Calibrating the CLINITEK Novus Quality Control Testing – CLINITEK Novus Quality Control Testing – Atellica UAS 800 Status log will indicate Calibration is required System status will display as Not Ready Waste container must not be full and rinse container must be at least 20% full Select the System button Then select Calibration Verify and/or enter the calibrator lot information Then Select Next The screen will show the correct order to place the calibrators in the rack – the tubes must be placed in this order or the calibration will fail After placing the rack on the rack handler, select Start The SG Well is cleaned as the first step in the calibration process As the calibration proceeds, the boxes will populate with information about the status of the calibration When complete, system will display outcome of the calibration To print the report, select the Print button To send to the LIS, select the Send button Select Exit to return to the System Menu Calibration & Quality Control Calibrating CLINITEK Novus System Calibrating CLINITEK Novus System Calibration & Quality Control Calibrating CLINITEK Novus System Status log will indicate Calibration is required System status will display as Not Ready Waste container must not be full and rinse container must be at least 20% full Select the System button Then select Calibration Verify and/or enter the calibrator lot information Then Select Next The screen will show the correct order to place the calibrators in the rack – the tubes must be placed in this order or the calibration will fail After placing the rack on the rack handler, select Start The SG Well is cleaned as the first step in the calibration process Quality Control Test – CLINITEK Novus System Calibration & Quality Control Quality Control tests should always be performed in accordance with local, state, and federal guidelines or national regulations There will be 2 controls run – 1 positive and 1 negative To begin, select the System button Select Control Follow the instructions on screen Select and enable each control lot to be used To change or add a lot number, select the Change buttons Once complete, select Next Follow the instructions on screen regarding test tube position and rack placement When ready, select Start The system will show which control test is in process, control number 1 in this case When the control tests are completed, their status will update to Completed Quality Control Test – CLINITEK Novus System Calibration & Quality Control Quality Control Test – CLINITEK Novus System Quality Control tests should always be performed in accordance with local, state, and federal guidelines or national regulations There will be 2 controls run – 1 positive and 1 negative To begin, select the System button Select Control Quality Control Test – Atellica UAS 800 Calibration & Quality Control Quality Control tests should always be performed in accordance with local, state, and federal guidelines or national regulations Select Quality Control on the menu bar Select the QC Settings tab If control lots are displayed, select the check boxes to indicate the controls you want to run If control lots are not displayed, select the +Add buttons Enter the following information for both the low and high control solutions: Expiration Lot number Liquid type RBC (min and max) WBC (min and max) Select the check boxes to indicate the controls you want to run Add 2 mL of low-level control solution to one test tube and 2 mL of high-level control to another Place test tubes into a rack with low level solution in position 1, high level solution in position 2 Select the Start QC button and rack handler moves rack into sampling area Click the check mark to process the QC samples When QC testing is complete, a message box indicates QC Passed or QC Failed for low- and high-level samples and results can be reviewed QC Test results can be viewed on: The Database screen The Quality Control screen QC history data can also be saved to a USB device On the QC Settings tab, click Output Select the USB drive location to save QC data QC lot data can also be deleted or modified by selecting the Delete or Modify buttons on the QC Settings tab Quality Control Test – Atellica UAS 800 Calibration & Quality Control Quality Control Test – Atellica UAS 800 Quality Control tests should always be performed in accordance with local, state, and federal guidelines or national regulations Click Quality Control on the menu bar Select the QC Settings tab If control lots are displayed, select them and click Start QC If the control lots are not displayed, select the +Add button and enter the following information for both the low and high control solutions: Liquid type Lot number Expiration RBC (min and max) WBC (min and max) Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com Disclaimer Final Assessment Test your knowledge by taking this quiz. You must score 80% to complete this course. Click the "Next" button to start the quiz. Final Assessment Final Assessment Test your knowledge by taking this quiz. You must score 80% to complete this course. Click the "Next" button to start the quiz. Quiz Your Score: %Results.ScorePercent%% (%Results.ScorePoints% points) Passing Score: %Results.PassPercent%% (%Results.PassPoints% points) Retake Quiz Retake Quiz Results Quiz Results Results Your Score: Passing Score: Review Quiz Retake Quiz Congratulations, you passed. You did not pass. You did not pass. Congratulations, you passed. Thank You! You have completed the Atellica 1500 Automated Urinalysis System course. Thank You! Thank You! You have completed the Atellica 1500 Automated Urinalysis System course. Question Bank 1 Which of the following is true about reagent humidity protection on the Atellica 1500 system? There is 3-way humidity protection: cards in closed cassette with desiccant pack, cassette sits in well-sealed compartment, leukocyte dry pad checked There is 2-way humidity protection: cassette sits in well-sealed compartment and leukocyte dry pad is checked There is 1-way humidity protection: leukocyte dry pad is checked There is no humidity protection Which of the following is true about reagent humidity protection on the Atellica 1500 system? Which of the following is true about reagent humidity protection on the Atellica 1500 system? There is 3-way humidity protection: cards in closed cassette with desiccant pack, cassette sits in well-sealed compartment, leukocyte dry pad checked There is 2-way humidity protection: cassette sits in well-sealed compartment and leukocyte dry pad is checked There is 1-way humidity protection: leukocyte dry pad is checked There is no humidity protection Incorrect You did not select the correct response. Correct You selected the correct response. What is the onboard stability of the chemistry analysis test pads? 1 day 5 days 10 days 14 days What is the onboard stability of the chemistry analysis test pads? What is the onboard stability of the chemistry analysis test pads? 1 day 5 days 10 days 14 days Incorrect You did not select the correct response. Correct You selected the correct response. During sediment analysis, how many images are taken with the digital camera? 1 image 5 images 15 images 50 images During sediment analysis, how many images are taken with the digital camera? During sediment analysis, how many images are taken with the digital camera? 1 image 5 images 15 images 50 images Incorrect You did not select the correct response. Correct You selected the correct response. What is the purpose of centrifugation during sediment analysis? Centrifugation is unnecessary and does not occur during sediment analysis Centrifugation ensures that cuvettes are correctly loaded with patient sample Centrifugation creates a sediment monolayer for high-quality and accurate digital image taking None of the above are correct What is the purpose of centrifugation during sediment analysis? What is the purpose of centrifugation during sediment analysis? Centrifugation ensures that cuvettes are correctly loaded with patient sample Centrifugation creates a sediment monolayer for high-quality and accurate digital image taking Centrifugation is unnecessary and does not occur during sediment analysis None of the above are correct Incorrect You did not select the correct response. Correct You selected the correct response. What is the magnification level of the microscope used during sediment analysis? 10x magnification 100x magnification 200x magnification 400x magnification What is the magnification level of the microscope used during sediment analysis? What is the magnification level of the microscope used during sediment analysis? 10x magnification 100x magnification 200x magnification 400x magnification Incorrect You did not select the correct response. Correct You selected the correct response. What is the maximum onboard capacity for sediment analysis cuvettes? 100 cuvettes 250 cuvettes 450 cuvettes 600 cuvettes What is the maximum onboard capacity for sediment analysis cuvettes? What is the maximum onboard capacity for sediment analysis cuvettes? 100 cuvettes 250 cuvettes 450 cuvettes 600 cuvettes Incorrect You did not select the correct response. Correct You selected the correct response. Which of the following is true about the reflex guidelines on the Atellica 1500 system? The system is not customizable, it will perform sediment analysis on all samples The system can be set to process all samples or process only chemically positive samples The system can be set to process all samples, chemically positive samples, or process based on customized rules None of the above are true Which of the following is true about the reflex guidelines on the Atellica 1500 system? Which of the following is true about the reflex guidelines on the Atellica 1500 system? The system can be set to process all samples or process only chemically positive samples The system can be set to process all samples, chemically positive samples, or process based on customized rules The system is not customizable, it will perform sediment analysis on all samples None of the above are true Incorrect You did not select the correct response. Correct You selected the correct response. Atellica 1500 Automated Urinalysis System 1.1 Welcome 1.2 Agenda 1.3 Introduction 1.4 Overview 1.5 Clinical Excellence 1.6 System Overview 1.7 Atellica 1500 Exterior & Interior 1.8 CLINITEK Novus Exterior 1.9 Atellica UAS 800 Exterior 1.10 CLINITEK Novus Interior Details 1.11 Atellica UAS 800 Interior Details 1.12 CLINITEK Novus Reagent 1.13 Atellica UAS 800 Consumables 1.14 Routine Operations 1.15 Power On the System 1.16 Prepare the System 1.17 Prepare Patient Samples 1.18 Run Patient Samples 1.19 View Patient Results 1.20 Results Management 1.21 Filter Patient Results 1.22 View Patient Results 1.23 Validate Patient Results 1.24 Edit Particle Tags 1.25 Maintenance 1.26 Daily Tasks – CLINITEK Novus 1.27 Daily Tasks – Atellica UAS 800 1.28 Weekly, Monthly & Periodic 1.29 Calibration & Quality Control 1.30 Calibrating CLINITEK Novus System 1.31 Quality Control Test – CLINITEK Novus System 1.32 Quality Control Test – Atellica UAS 800 1.33 Disclaimer 1.34 Final Assessment 1.37 Thank You!
- atellica
- uas
- 1500
- urine
- analysis
- introduction
- maintenance
- poc
- system overview