Siemens Healthineers Academy
AI-Rad Companion - Chest X-ray on <i>syngo</i>.via OpenApps User Guide

AI-Rad Companion - Chest X-ray on syngo.via OpenApps User Guide

This user guide provides information on installing and configuring the AI-Rad Companion Chest X-ray on syngo.via OpenApps, including steps for getting PACS-ready AI results and optional expert settings.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet, smartphone)

AI-Rad Companion Chest X-ray on syngo.via OpenApps Guide AI-Rad Companion Chest X-ray* Please follow these steps below to get PACS-ready AI results for AI-Rad Companion Chest X-ray: 1. Install AI-Rad Companion Chest X-ray from the Digital Marketplace. SIEMENS - A Loan / Register OpenApps Heolthineers Digital Marketplace SIEMENS Healthineers Digital Marketplace Catalog Install Welcome to the Digital Marketplace achod.comPAS Automated and integrated in the clinical workflow Healthineer SIENCMS our result(s): 64 AF Rad Companion Chest C Al-And Companion Chest X-ray PROMISE Hermia Orgon Dosimetry What is it? The Al flad Companion Chest X ray works lhe a second or ford reader to support radiologie is daghosn int dinical deason esting it is cipatie to characterize and highlight poeunnothocrx, pulmonery levigne (nodules, mmers, and pardomat, striestatis consolidation and pleural offunins: The algorithun haind on deep learning links the findings to the riche enstory and mark them on The result image. ------ 2. You get automatic preprocessed results on syngo.via for the incoming Chest X-ray study. Steps for further expert settings (Optional) • Learn how to set automatic transfer of results to PACS • Decide the type of the Report format • Possibility to disable a particular Radiographic finding or Tubes and Catheters 1. Click on Configuration at the top right corner of syngo.via and select Configuration Panel. ? JA Configuration Panel Administration Portal Flight Recorder Client-Server Connection Test *: AI-Rad Companion Chest X-ray is not commercially available in all countries. Its future availability cannot be ensured. SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date: 21 Apr 2023 | HILS 2224 Healthineers Job Aid Effective Date: 19 Dec 2024 | QR700017230 Job Aid | Chest X-ray on syngo.via OpenApps Guide Effective Date: 19 Dec 2024 | QR700017230 2. Select the OpenApps tab. AI-Rad Companion Chest X-ray processes only frontal views with preconfigured rules for in- coming Chest X-ray images. Optional Step: Add new rules in addition to the existing rule by clicking on Add New Rule. Then add the criterias by clicking on Add Condition. SIEMENS ..... Healthineers .. Configuration Panel Client Settings Advanced Visualization Display And Behavior Export OpenApps Reporting OpenApps PACS Ready Technology Activate automatic processing on incoming studies Limit processing to studies that arrive on the same day of the aquisition Available Processing Apps Rule #1 Modality (0008,0060) contains CT Study Description (0008,1030) contains Thorax Al-Rad Companion Chest CT Add Condition Version: 2024.11.15.1 Supports: CT Automatic processing on request of sending modality Automatic Archiving Rule Name Rule #2 Add New Rule Chest CR Modality (0008,0060) contains CR Body Part Examined (0018,0015) contains Chest Al-Rad Companion Chest X-ray + Add Condition Version: 2024.11.15.1 Chest DX Supports: CR, DX Modality (0008,0060) contains DX Body Part Examined (0018,0015) contains Chest + Add Condition Automatic processing on request of sending modality Automatic Archiving Rule Name Rule #3 Add New Rule OK Apply Cancel SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 2 of 6 Job Aid | Chest X-ray on syngo.via OpenApps Guide Effective Date: 19 Dec 2024 | QR700017230 3. Automatic Archiving to PACS is switched OFF by default. Enable the tool by clicking inside the box to send the AI results automatically to PACS. Chest CR Modality (0008,0060) contains CR Body Part Examined (0018,0015) contains Chest X Al-Rad Companion Chest X-ray Add Condition Version: 2024.11.15.1 Chest DX Supports: CR, DX Modality (0008,0060) contains DX Body Part Examined (0018,0015) contains Chest contains X X X + Add Condition Rule #3 contains + Add Condition enlest of sending modality Automatic Archiving Rule Name Rule #4 Add New Rule 4. Click on the icon to open the Chest X-ray settings dialog box. Chest CR Modality (0008,0060) contains CR Body Part Examined (0018,0015) contains Chest Al-Rad Companion Chest X-ray + Add Condition Version: 2024.11.15.1 Chest DX Supports: CR, DX Modality (0008,0060) contains DX Body Part Examined (0018,0015) contains Chest contains + Add Condition - Rule #3 contains + Add Condition Automatic processing on request of sending modality Automatic Archiving Rule Name Rule #4 Add New Rule 5. Data Transfer: Select the report format by enabling the toggle button in front of the report for- mat. By default, Secondary Capture Report format is enabled. Enable Structured Report based on PACS capability to read DICOM SR objects. The DICOM SR results can be consumed by the PACS system to filter and/or sort the worklist according to these findings identified by AI-Rad Companion Chest X-ray. Enable Overlay results to toggle between the finding graphics and the original image. SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 3 of 6 Job Aid | Chest X-ray on syngo.via OpenApps Guide Effective Date: 19 Dec 2024 | QR700017230 Click on Save to save the changes. Al-Rad Companion Chest X-ray Settings ? X Data Transfer Data Transfer Radiographic Findings Create Report Formats Selection Tubes & Catheters Secondary Capture Report O Portrait Orientation O Landscape Orientation Structured Report @ Overlay Results(Grayscale Softcopy Presentation State) 1 Other Report type Selection Failure Report 1 Report Language English Changes made apply to all users and will come into effect for the maxi nuncascad casas Save 6. Click on Radiographic findings. All findings are enabled by default. Deactivating a specific finding will remove it from the DICOM SR and DICOM GSPS results. Deactivating a finding affects all users of AI-Rad Companion Chest X-ray. Click on Save to save the changes. Al-Rad Companion Chest X-ray Settings ? Data Transfer Radiographic Findings Radiographic Findings indings Turn On/Off Tubes & Catheters Consolidation Atelectasis Pulmonary Lesions Pleural Effusion Pneumothorax Changes made apply to all users and will come into effect for the next processed cases. Save SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 4 of 6 Job Aid | Chest X-ray on syngo.via OpenApps Guide Effective Date: 19 Dec 2024 | QR700017230 7. Click on Tubes and Catheters to enable detection of endotracheal tubes. AI-Rad Companion Chest X-ray will mark the tip of the endotracheal tube if detected. Detection of endotracheal tubes shall be enabled by default. If endotracheal tube detection is disabled, this section will not be displayed in results. Click on Save to save the changes. Al-Rad Companion Chest X-ray Settings ? X Data Transfer Tubes & Catheters Radiographic Findings Endotracheal Tube Tubes & Catheters Changes made apply to all users and will come into effect for the next nroc Save 8. After making the changes, click Apply and OK. Chest CR Modality (0008,0060) contains CR Body Part Examined (0018,0015) contains Chest X X Al-Rad Companion Chest X-ray Add Condition Version: 2024.11.15.1 Chest DX Supports: CR, DX Modality (0008,0060) contains DX Body Part Examined (0018,0015) contains Chest contains X X X + Add Condition Automatic processing on request of sending modality Automatic Archiving Rule Name Rule #4 Add New Rule OK Apply Cancel SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 5 of 6 Job Aid | Chest X-ray on syngo.via OpenApps Guide Effective Date: 19 Dec 2024 | QR700017230 Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or In- structions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Opera- tor Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety infor- mation like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functional- ity”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fic- tional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 6 of 6

  • ai-rad-companion
  • ai
  • companion
  • artificial
  • intelligence
  • confirmation
  • workflow
  • software
  • overview
  • chest- x-ray
  • QR700017230