CLEARstent &CLEARstent Live 应用简介

CLEARstent &CLEARstent Live 应用简介

本文档介绍支架精显的原理,临床应用。

SIEMENS Healthineers CLEARstent & CLEARstent Live应用简介 功能介绍 一 1)ClearStent 图像功能,可以增强纤细结构显示,如膨胀的支架。通过平均化一个序列 的若干帧图像以及兼顾到支架标记的对齐,可以创建合成图像。 2) ClearStent Live 序列,将提供支架的实时稳定显示。 0:57:28 AM 16 - 1/36 ClearStent造影剂充盈显示效果 ClearStent支架解构显示效果 0/23/2019 HFS 04:16 PM /com///E/S/ - 36/48 21 sec ClearStent Live在支架对位时实时稳定显示 learStent live ClearStent Live在支架对位时稳定显示 EE 20% ODO 60% n 22 101 AO 16º / CRAN 29º 2.应用选择 1)CLEARstent 2)CLEARstent Live •可进行后处理操作 •实时采集序列 •尽可能提高图像质量观察单个支架 •查看支架与心脏解剖位置的关系, •评估支架使用情况,例如支架展开的区域 •优化支架定位 •提供临床参考 •在消除心脏运动的同时,优化图像质量 Job Aid | CLEARstent & CLEARstent Live应用简介 Unrestricted | Effective Date: 2020-05-15 | HOOD05162003087449 https://www.siemens.com/pepconnect SIEMENS Healthineers CLEARstent and CLEARstent Live 原理 它利用动态校正的X线透视显影技术,自动根据动态补偿采集的连续帧图像叠加转换成 数字电影来显影支架,以增强植入冠脉支架的可视性,有助于检测支架的扩张和血管贴壁 情况。 Register& Average Frames O A B Original I ranslation Rotation Scaling Job Aid | CLEARstent & CLEARstent Live应用简介 Unrestricted | Effective Date: 2020-05-15 | HOOD05162003087449 https://www.siemens.com/pepconnect SIEMENS Healthineers CLEARstent and CLEARstent Live临床应用 IMAGES IN INTERVENTION Stent Deformation in Bifurcation Stenting With Final Kissing Balloon Inflation In Vivo Demonstration With Enhanced Cine Fluoroscopic Imaging Stephan Achenbach, MD, Christian Schlundt, MD Erlangen, Germany Various techniques for stent deployment in bifurcation lesions have been developed. In gen- given the poor x-ray absorption of modern thin- cral, a single-stent approach is preferable, but strut stents. Software tools have become available balloon dilation of the side branch can lead to that permit improved visualization of coronary deformation of the main branch stent, which is stents in cine fluoroscopy. They improve contrast- incompletely resolved by "final kissing balloon to-noise ratio (and, hence, resolution) by aver- dilation" (1,2). In vivo imaging of stent expansion aging consecutive cine fluoroscopic frames. Balloon markers are used as reference points in and deformation by fluoroscopy is challenging, order to eliminate motion. We present cine fluo- roscopic images obtained using a commercially available stent enhancement tool (ClearStent, LAO 10 CRAN 44 Siemens Healthcare, Forchheim, Germany) on a single-plane x-ray angiographic flat panel system (Artis Zee, Siemens Healthcare). The patient was a 78-year-old woman with typical chest pain and Figure 1. Coronary Angiogram Showing Bifurcation Stenosis Bifurcation stenosis (arrow) of the left anterior descending cor- onary artery 1st disgonal banch (Medina 0/1/0) Fractional flow reserve in the left anterior descending coronary artery was measured to be 0.76. Figim 2. Stont Placed in Main Branch From the Department of Cardiology, University of Erlangen, Edangen, Enhanced cine fluoroscopic image (ClearStent, Siemens Germany. Dr. Achenbach is a cunaaltant to Siemens Healthcare and Healthcare) of a drug-eluting stent (Xience Prime 3.0/15 mm, Abbott, has received speaker honorarla from Siemens Healthcare and Abbott Vascular) placed in the left anterior descending coro- Abbott, and his institution has received research grants from Siemens nary artery. The side-branch wire is jailed. Note the 2 markers Healthcare and Abbon. Dr. Schlandt has received apeaker honoraria of the bioresorbable scaffold (Absorb 2 5/18 mm, Abbott from Abbott Vascular) placed immediately distal to the drug-eluting stent Mamascript received October 10, 2013; accepted October 24, 2013. (arrow). Job Aid | CLEARstent & CLEARstent Live应用简介 Unrestricted | Effective Date: 2020-05-15 | HOOD05162003087449 https://www.siemens.com/pepconnect SIEMENS Healthineers CLEARstent and CLEARstent Live临床应用 支架展开前,确认支架的位置和大小 Job Aid | CLEARstent & CLEARstent Live应用简介 Unrestricted | Effective Date: 2020-05-15 | HOOD05162003087449 https://www.siemens.com/pepconnect SIEMENS Healthineers CLEARstent and CLEARstent Live临床应用 支架展开后,确认支架的位置、展开和贴壁情况 Job Aid | CLEARstent & CLEARstent Live应用简介 Unrestricted | Effective Date: 2020-05-15 | HOOD05162003087449 https://www.siemens.com/pepconnect SIEMENS Healthineers Disclaimer 请注意,该资料仅供学习使用! 为了正确使用软件或硬件,请务必使用由西门子医疗发行的《操作手册》或《使用说明》(以下统称为《操 作手册》)。本材料仅学习参考使用,不能代替《操作手册》。本培训中使用的材料可能未及时更新,并不 一定反映软件和硬件最新版本。 操作手册应作为您的主要参考资料,特别是在涉及警告和注意事项之类的安全信息时。 注意:本资料中显示的某些功能为可选项,可能未包含在您的系统中。 某些产品,与产品相关的声明或者功能(以下统称为“功能”),可能尚未在您的国家/地区进行商业销售。 受 监管要求所限,我们并不能保证所述功能将来能够向特定国家/地区提供。请联系当地的西门子医疗销售代表 获取最新信息。 未经书面授权,不得复制、传播、分发该资料及其相关内容,违者将承担相关责任。 所有患者的姓名和数据、参数和配置相关的名称均为虚构,仅作示例使用。 所有权利,包括专利权或产品的注册、设计的权利,均予保留。 版权所有 © 西门子医疗系统有限公司 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers

  • Artis
  • ClearStent
  • ClearStent Live