Siemens Healthineers Academy
MOBILETT Mira Max 操作流程

MOBILETT Mira Max 操作流程

本文档将展示 MOBILETT Mira Max 的操作流程

SIEMENS Quality ID : HOOD05162003179292 Effective date: 2021-04-16 Healthineers Mobilett Mira Max 操作流程 https://www.siemens.com/pepconnect 西门子医疗系统有限公司 云端医学教育平台 Unrestricted © Siemens Healthcare GmbH, 2020 系统开机 SIEMENS Healthineers 1 2 3 4 5 6 7 8 19 O 设备开机键 软件开关 点击设备开机键,输入开机密码1111,然后按下软件开关,系统开机 Unrestricted © Siemens Healthcare GmbH, 2020 病人登记 SIEMENS Healthineers DM uGym2 10. r 25031 .. 25-03-2 ... ... - - - - - 25-03-201 ... 6 # 3, Emerg. E_3 06-03-2 ... *. 06-03-201 ... 2 手动登记 # AID A - (黑体必填) RIS刷新 RID 双击病人进入检 查 IA 1 2 3 4 16 7 8 9 0 = q W e t n O P a S d f g h k Del TO Shift Z c V b n m Shift × - Execute config-check, Service Caps Lock Alt Control Execute config-check, Servic Unrestricted © Siemens Healthcare GmbH, 2020 病人检查 SIEMENS Healthineers Emergency, 9 um Manager X UGym2 250319 145817 Patient Emergency. 4 2.58 uGym2 Available Exama / Organ Programs Assigned Exuma / Organ Programma R 0.00 X CHEST BABY BREAST O X CHEST CHILDREN 1_TC_FreeExp_Presettings_Flip RAD FreeExp_70KV. 5x5coll 1_TC_FreeExp_Presettings_Label 1_TC_FreeExp_Presettings_Rotation 1_TC_FreeExp_StandParam_Collimation RAD_FreeExp_40KV_5x5coll [I] 115 cm RAD_FreeExp_70KV_5x5coll RAD FreeExp_115SID 20x20coll Add 55 RAD_FreeExp_300SID 20x20coll RAD_FreeExp_nochangeXnochange Replace + RAD_FreeExp_43×43coll 1_TC_FreeExp_StandParam_SID_TOD mAs 2.8 1_TC_FreeExp_XRayParam_cu-Filter 1_TC_FreeExp_XRayParam_pt + IMPORTIERT TC TESTPROGRAMS Favorites Organ Prog Delete Tools 出图后可根据需 Details Accession Number Dotals Scheduled Procedure Step 要进行图像剪裁 Home Examination Cancel Read 进入检查(Examination),点击器官程序管理器选择投照部位,可根据实际情况修改曝光参数,右下 角显示Ready或就绪后,可以曝光 Unrestricted © Siemens Healthcare GmbH, 2020 摆位曝光 SIEMENS Healthineers 45 60 75 90 75 Mobilent Mira Max 打开支臂,根据需要进行旋转及拉伸,激活支臂上微调按键可进行设备移动,打开LED灯,调整照射野及投照角度 Unrestricted © Siemens Healthcare GmbH, 2020 摆位曝光 SIEMENS Healthineers IR >)) 2 3 DO 4 5 1.状态灯 2.预曝光 3.曝光键 4.照射野 5.遥控器罩壳 遥控器曝光: 手闸曝光: 一、曝光前可先按下照射野指示灯判断是否在遥控范围内 按住预曝光键待旋转阳极启动后按下曝光键 二、曝光时先按住预曝光键1-2秒,松开后接着按住曝光键 三、在听到曝光提示音结束后曝光完成 Unrestricted © Siemens Healthcare GmbH, 2020 添加标号 SIEMENS Healthineers UGym R X CHEST, BABY X CHEST CHILDREN Process. Graphics Rad 在图像后处理(Postprocessing)- 图形(Graphics)中选择添加左右标 号-将标号拖到合适的位置 Label L/R L R Image Tools Click on the image to set the label Post-processing mode Clear Close OK Unrestricted © Siemens Healthcare GmbH, 2020 调节窗值 SIEMENS Healthineers uGym2 2.58 R X CHEST.BABY X CHEST CHILDREN Process. Graphics Rad 在图像后处理(Postprocessing)- RA R 处理(Process)中选择窗值键-在屏 幕上调节窗宽窗位 如果设备连接鼠标,按住鼠标中轴即 可快捷调节窗宽窗位,鼠标右键可选 中或不选该图像,未选中的图像将不 Image Tools 参与打印及手动发送 @ Ready Unrestricted © Siemens Healthcare GmbH, 2020 打印发送 SIEMENS Healthineers 2 2 S S 2 uGy*m2 S uGy"m2 Patient Patient 27.10 27.10 Examination RAD RAD Select RAD V Examination Film Send RAD Select Film Send Printer DV5800 Target Name 14X17IN L2X1 Target Postprocessing Size 14IN×17IN/L Postprocessing Target Layout 2x1 Camera not selectedl, default 覆盖 Send Exam Protocol es: BIN OR4, 1a1, 100% OnY Scale 100% SCimage Auto Override configured settings 配置 DICOM Dose SR Documentation Documentation % 100 设置 Copies Anonymous Override configured settings Hide Text Fools Tools 打印 预览 S/N:2044E5 044E5 11Bit(2/2] @ xx ( 1/2) O 图像文档化(Document)-印片(Print)-选中需要打印的图 图像文档化(Document)-传送(Send)-选 像-点击覆盖配置的设置-选择相机-打印尺寸-打印格式后预览- 中需要发送的图像,点击发送 确认无误后点击打印 Unrestricted © Siemens Healthcare GmbH, 2020 系统关机 SIEMENS Healthineers 1 2 3 4 5 6 7 8 19 设备关机键 软件开关 设备使用完毕后,将支臂及平板收回,按下软件开关,待软件系统关闭后,按下设备关机键关闭系统。 Unrestricted © Siemens Healthcare GmbH, 2020 Disclaimer SIEMENS Healthineers 请注意,该资料仅供学习使用! 为了正确使用软件或硬件,请务必使用由西门子医疗发行的《操作手册》或《使用说明》(以下统称为《操作手册》)。本材料仅学习参考使用,不能代替《操作 手册》。本培训中使用的材料可能未及时更新,并不一定反映软件和硬件最新版本。 操作手册应作为您的主要参考资料,特别是在涉及警告和注意事项之类的安全信息时。 注意:本资料中显示的某些功能为可选项,可能未包含在您的系统中。 某些产品,与产品相关的声明或者功能(以下统称为“功能”),可能尚未在您的国家/地区进行商业销售。 受监管要求所限,我们并不能保证所述功能将来能够向特 定国家/地区提供。请联系当地的西门子医疗销售代表获取最新信息。 未经书面授权,不得复制、传播、分发该资料及其相关内容,违者将承担相关责任。 所有患者的姓名和数据、参数和配置相关的名称均为虚构,仅作示例使用。 所有权利,包括专利权或产品的注册、设计的权利,均予保留。 版权所有 © 西门子医疗系统有限公司 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Unrestricted © Siemens Healthcare GmbH, 2020

  • FLC
  • Mira
  • Mobile