Siemens Healthineers Academy
乳腺X线摄影-导出图像

乳腺X线摄影-导出图像

本文档将指导您如何导出想要的图像

SIEMENS Quality ID : HOOD05162003033294 Healthineers Effective date: 2019-10-28 乳腺X线摄影-导出图像 https://www.siemens.com/pepconnect 西门子医疗系统有限公司 云端医学教育平台 1 Unrestricted © Siemens Healthcare GmbH, 2019 乳腺X线摄影-导出图像---U盘 SIEMENS Healthineers Patient Transfer Examination Edit View Image Tools Scroll Options Help Examination [ Patient Browser FOX Patient Transfer Edit View Worklist Filter Sort Private Applications Options Help Import Ctrl+ Open patient Archive to DVDRW Archive to ... Send to ... Operator: Viewing Export to. Eject from DVDRW Eject from .. FD Bilateral Mar [2] MAMMOGRAM, Diagnosis Procedure: 选择要导出的图像,点击 Finalize Medium and Eject from DVDRW loom/ // // / OPEN /com/ / / /S/ / INP/LOC/s [1] MAMMOGRAM raw, Diagn( Patient Browser对话框上方的 Local Job Status ... Ctrl+L PV sequence: /com///// / INP/LOC/s D Filming Network Job Status ... Ctrl+N Import from Off-line ... Transfer—Export to Off-line.... Export to Off-line. Record Off-line Files O Auto Filming wang hong O Auto Expose ///// / OPEN Acquisition GUO XIAO MIN Post processing 11/11/ / OPEN Close patient WANG LING YAN //p//// / OPEN Procedure: Patient name chen xiao zt Date of birth 4/24/1975 Patient ID MG 190424004 Study description FD Bilateral Mammogram Study date 4/24/2019 Modality MG Images 1 2 3 4 Current Filter: Off -+ -+ Decomp Adv PNP Device Mounted - Drive(G:): Total Space(7475 MB) 2 Unrestricted © Siemens Healthcare GmbH, 2019 乳腺X线摄影-导出图像---U盘 SIEMENS Healthineers Patient Transfer Examination Edit View Image Tools Scroll Options Help Examination Patient Browser -O X Patient Transfer Edit View Worklist Filter Sort Private Applications Options Help do XI Open patient Export to Off-line X Operator: Viewing Objects should be exported to Logical Name G:\ Local D [2] MAMMOGRAM, Diagnosis Procedure: 系统自动弹出的Export to Off- Path G:\ /com/ / / /S/ / INP/LOC/s Schedu [1] MAMMOGRAM_raw, Diagn( line....对话框,在Logical Name hPACSWLN /com///// / INP/LOC/s PV sequence: Filming DVDRV Select format DICOM ......................... DICOM 中选择U盘,并在Select format Quality factor Bitmap JPEG AVI Frame Rate 8 Auto Filming 中选择要导出的图像类型,点 O Auto Expose Acquisition 击OK开始导出图像。 Export Post processing Il without image text Close patient without graphics Procedure: Patient name anonymously 4/1975 Patient ID MG 190424004 注意:U盘一定要确保没有病毒, Study descri Dummy Name 2019 Modality MG Images Default Configuration 要求插入电脑前,格式化U盘, Service Configuration 1 或给U盘杀毒。 Resize to . None 2X € 4X JOff OK Cancel Connect As .. Help + - + Decomp Adv. PNP Device Mounted - Drive(G:): Total Space(7475 MB) 3 Unrestricted © Siemens Healthcare GmbH, 2019 乳腺X线摄影-导出图像---光盘 SIEMENS Healthineers Patient Transfer Examination Edit View Image Tools Scroll Options Help Examination Patient Browser FOX Patient Transfer Edit View Worklist Filter Sort Private Applications Options Help Import Ctrl+ Open patient Archive to DVDRW Archive to IV ?ª Send to .. Operator: Viewing Export to .. Eject from DVDRW Eject from .. FD Bilateral Mar [2] MAMMOGRAM, Diagnosis Finalize Medium and Eject from DVDRW Procedure: 选择要导出的图像,点击 /com/p/ / /s/ / OPEN /com/P/ / /S/ / INP/HIS/s [1] MAMMOGRAM_raw, Diagn( Local Job Status. Ctrl+L /com///// / INP/HIS/s PV sequence: Patient Browser对话框上方的 Network Job Status .. Ctrl+N Filming Import from Off-line .. Transfer—Export to Export to Off-line. Record Off-line Files TITTTTT DONE D Auto Filming Test 11/11/ 1 DONE O Auto Expose Acquisition 注意:若未装光盘或光盘系统 chen xiao yan /p/ / /s/ / OPEN Post processing chen xiao zhi Close patient 未识别,Export to为灰色。光盘 / // / /s/ / OPEN Patient name lin zhen mei Date of birth 2/25/1995 Patient ID MG 19070301 Procedure: Study description FD Bilateral Mammogram Study date 7/3/2019 Modality MG 格式要求为DVD-R Images 1 2 3 4 Current Filter: Off -+ -+ Decomp Adv Error! Archive/Export job for CD/DVD/BD canceled O 4 Unrestricted © Siemens Healthcare GmbH, 2019 乳腺X线摄影-导出图像---光盘 SIEMENS Healthineers Patient Transfer Examination Edit View Image Tools Scroll Options Help Examination Patient Browser LOX Patient Transfer Edit View Worklist Filter Sort Private Applications Options Help XI Open patient B xi Export To X Operator: Viewing Destination Compression | Quali ... Label on medium |Medium Capacity Total Capacity DVDRW None 0 4.06 GB 4.38 GB Local Database Procedure: 在弹出的Export to对话框中点击 Scheduler hPACSWLM PV sequence: Export DVDRW Filming Export Cancel Help test 11/11/ / DONE 1 Auto Filming test O Auto Expose 111/// / DONE chen xiao yan Acquisition /p/ / /s/ / OPEN Post processing chen xiao zhi Close patient //// / / OPEN Patient name lin zhen mei Date of birth 2/25/1995 Patient ID MG19070301 Procedure: Study description FD Bilateral Mammogram Study date 7/3/2019 Modality MG Images 1 2 3 4 Current Filter: Off + + Decomp Adv. Error! Archive/Export job for CD/DVD/BD canceled 5 Unrestricted © Siemens Healthcare GmbH, 2019 乳腺X线摄影-导出图像---光盘 SIEMENS Healthineers Patient Transfer Examination Edit View Image Tools Scroll Options Help Examination Patient Browser Patient Transfer Edit View Worklist Filter Sort Private Applications Options Help XH Open patient Operator: Viewing Local Database lin zhen mei EE FD Bilateral Mar [2] MAMMOGRAM, Diagnosis //p/ / // / OPEN /com/p// // / OPEN Procedure: 系统自动弹出Enter Label对话框, /com/P/ / /S/ / INP/HIS/s Scheduler Tan [1] MAMMOGRAM raw, Diagn( hPACSWLM 11/11/ / DONE /com///// / INP/HIS/s DVDRW Enter Label PV sequence: 在Label on medium中根据实际 X Filming Device DVDRW 情况输入光盘名称,并勾选 Label on medium Viewing tool O Auto Filming Viewing tool,点击OK开始导出 O Auto Expose Acquisition 图像。 Post processing OK Cancel Help Close patient TITTI / OPEN Patient name lin zhen mei Date of birth 2/25/1995 Patient ID MG 19070301 Procedure: Study description FD Bilateral Mammogram Study date 7/3/2019 Modality MG 注意:光盘命名不可小于三个 Images 字符。若不需要读图工具, 1 2 3 4 Querying database ... Current Filter: Off Viewing tool可不勾选。 -+ -+ Decomp Adv Processing export request. 6 Unrestricted © Siemens Healthcare GmbH, 2019 Disclaimer SIEMENS Healthineers 请注意,该资料仅供学习使用! 为了正确使用软件或硬件,请务必使用由西门子医疗发行的《操作手册》或《使用说明》(以下统称为《操作手册》)。本材料仅学习参考使用,不能代替《操作手册》。 本培训中使用的材料可能未及时更新,并不一定反映软件和硬件最新版本。 操作手册应作为您的主要参考资料,特别是在涉及警告和注意事项之类的安全信息时。 注意:本资料中显示的某些功能为可选项,可能未包含在您的系统中。 某些产品,与产品相关的声明或者功能(以下统称为“功能”),可能尚未在您的国家/地区进行商业销售。 受监管要求所限,我们并不能保证所述功能将来能够向特定国家/ 地区提供。请联系当地的西门子医疗销售代表获取最新信息。 未经书面授权,不得复制、传播、分发该资料及其相关内容,违者将承担相关责任。 所有患者的姓名和数据、参数和配置相关的名称均为虚构,仅作示例使用。 所有权利,包括专利权或产品的注册、设计的权利,均予保留。 版权所有 © 西门子医疗系统有限公司 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 7 Unrestricted © Siemens Healthcare GmbH, 2019

  • Mammomat Inspiration
  • Mammomat Fusion