Mensagens do Sistema e Histórico de Mensagens
Este vídeo oferece uma visão geral sobre o Histórico de Mensagens e as diferentes Mensagens do Sistema.
System messages are displayed as icons in the status bar in a single-monitor configuration. All system messages are summarized in a message history in a 2-monitor configuration. The system messages on the main monitor refer to problems related to the MRI system, and on the second monitor refer to problems related to AUNR view and go. These messages are usually classified as errors or information. In addition, there is an icon to open the MR scanner and echo exition dialog box on the main monitor. This dialog box includes warnings related to the MRI hardware, for example, the cooling system, coil selection, and resonance frequency. Different icons in the status bar inform you about the number and type of messages. The message history icon is displayed if there are no new or unread messages. If there are multiple messages in the message history, the icon with the highest priority will be displayed in the status bar. Click the status bar icons to open the message history and the dialog box to read the message details. Open the message. Therefore, you should always check the icons in the status bar and open the related dialogs if workflows are interrupted or errors are displayed to continue with the workflow. Read the details of the messages displayed in the message threads. Remember if you open the message history dialog box, all messages will automatically be set to read and the icon will change on the screen. So, make sure to check all the messages in the message history before continuing the scanning.
0000 02:25 03:37 04:50 01:47 02:27 Mensagens do Sistema e Histórico de Mensagens SIEMENS Brain Dot Engine As mensagens do sistema são exibidas como ícones na barra de status. Message History Date and Time Measurement has been stopped by the user. 4/15/2020 4:02:17 PM Continue Show only new messages Close Em uma configuracão de monitor único, todas as mensagens do sistema são resumidas em um histórico de mensagens. Em uma configuração com dois monitores, as mensagens do sistema no monitor principal referem-se a problemas relacionados ao sistema de ressonância magnética e, no segundo monitor, referem-se a problemas relacionados ao MR View&GO. Essas mensagens são geralmente classificadas como erros ou informações. Além disso, há um ícone para abrir a caixa Message Meaurement has been stopped by the user. Favorite Tools SAR de diálogo "MR Scanner and Acquisition" no monitor principal. MR Scanner & Acquisition Message Text Domain Date Frequency adjustment did not converge. 4/15/2020 3:57:57 PM The resonance frequency could not be determined. X You can retry or restart the workplace. If the problem still persists, please use the manual adjustment platform for further analysis. Adjustment did not converge. Received MR signal was too low. Go Cancel Please check patient positioning, coil selection, and adjustment volume. Scanner hardware warning: MRI_FRR [s] 4/15/2020 3:57:57 PM Door of the examination room is open. Close the door. If the problem persists, please contact Siemens Service. Essa caixa de diálogo inclui avisos relacionados ao hardware de RM, por exemplo, o sistema de resfriamento, a seleção da bobina e a frequência de ressonância. AR Stimu Mode Diferentes ícones na barra de status o informam sobre o número e o tipo de mensagens. O ícone do histórico de mensagens é exibido se Unread error Clicking on this icon provides access to recent user messages. More não houver mensagens novas ou não lidas. More DE Se houver várias mensagens no histórico de mensagens, o ícone com a prioridade mais alta será exibido na barra de status. Type Type Message Preparation of measurement system has failed. 4/15/2020 3:53:08 PM AutoAlign: Some AutoAlign landmarks could not be detected reliably. Please check the marked protocols or try to 4/15/2020 3:51:30 PM improve the anatomical coverage of the AutoAlign scout. Clique nos ícones da barra de status para abrir o histórico de mensagens e a caixa de diálogo. Para ler os detalhes da mensagem, abra a mensagem. Sender: DISPLAYDEMON e p2 Portanto, você deve sempre verificar os ícones na barra de status e abrir as caixas de diálogo relacionadas AutoAlign: Some AutoAlign landmarks could not be detected reliably. Please check the marked protocols or try to improve the anatomical coverage of the AutoAlign scout. se os fluxos de trabalho forem interrompidos ou se forem exibidos erros. Para continuar com o fluxo de trabalho, leia os detalhes das mensagens exibidas nos históricos de mensagens. Lembre-se: se você abrir a caixa de diálogo do histórico de mensagens, todas as mensagens serão automaticamente definidas como lidas e o ícone será alterado na tela. Portanto, certifique-se de verificar todas as mensagens no histórico de mensagens antes de continuar o scanning (exame). C Siemens Healthcare GmbH 2024 Por favor, observe que este material é destinado apenas para fins de treinamento! Para o uso adequado do software ou hardware, use sempre o Manual do Operador ou as Instruções de Uso emitidos pela Siemens Healthieers. Este material deve ser utilizado apenas como material de treinamento e não substituirá de forma alguma o Manual do Operador. Qualquer material usado neste treinamento não será atualizado regularmente e não reflete necessariamente a versão mais recente do software e do hardware disponíveis no momento do treinamento. O Manual do Operador deve ser usado como referência principal, em particular para informações relevantes de segurança, como avisos e precauções. Nota: Algumas funções mostradas neste material são opcionais e podem não fazer parte do seu sistema. Certos produtos, reclamações ou funcionalidades relacionadas aos produtos podem ainda não estar disponíveis comercialmente em seu país. Devido a requisitos regulamentares, a disponibilidade futura das referidas Funcionalidades em qualquer país em específico não é garantida. Por favor, entre em contato com seu representante de vendas local da Siemens Healthineers para obter as informações atuais sobre o assunto. A reprodução, transmissão ou distribuição deste treinamento ou de seu conteúdo não é permitida sem autorização expressa por escrito. Infratores serão responsabilizados por danos. Todos os nomes e dados de pacientes, parâmetros e designações são fictícios e apenas exemplos. Todos os direitos, incluindo direitos criados por concessão de patente ou registro de um modelo de utilidade ou desenho, são reservados. Heal Healthineers
- XA30
- mensagens do sistema
- ícone de mensagem
- barra de status
- histórico de mensagens
- histórico
- aquisição do scanner mr
- mensagem de erro
- erro
- erros
- aviso
- informações
- janela de erro
- janela de mensagem
- janela de mensagens
- pop-up de erro
- pop-up de erro
- pop-up de mensagem
- pop-up de mensagem
- ressonância
- ressonancia
- magnética
- magnetica
- rm
- irm
- mr
- mri