Substituindo as Sondas do Bocal do Secador no Analisador Atellica® CH - Versão 1.26 e Superiores

Substituindo as Sondas do Bocal do Secador no Analisador Atellica® CH - Versão 1.26 e Superiores

Este vídeo fornece instruções sobre como realizar a tarefa de manutenção conforme necessário para substituir as sondas dos bocais do secador no Analisador Atellica® CH.

This video will show you the steps on how to replace the nozzle probes of the CH Up Chemistry Analyzer dryer. To replace the dryer nozzle probes, the system must enter a diagnostic state. To get started, select trouble shooting. Then select opperater diignostics. Select the appropriate CH analyzer module. From the menu at the top of the screen, select enterdide nostex. Then select Yes. Wait for the module to enter the diagnostic state. In the Subsystems topic, select probes. Select to replace the dilution drying probe or to replace the reaction drying probe. Select perform. Then select Yes. Wait for the analyzer to prepare for maintenance. The covers are automatically unlocked when unlocked. The cover locks automatically unless the operator opens or removes the cover within 30 seconds. Open the back cover of the CH analyzer. If the cover is locked before you can open it, select the button in the system status area to unlock the back cover. There is a dryer nozzle probe for the reaction ring and another dryer nozzle probe for the dilution ring. The 2 nozzle probes of the dryers are interchangeable. Before you begin removing one of the probes from the dryer nozzle, cover the covetes with a paper towel to protect them from debris. Unscrew the probe housing assembly counterclockwise to access the dryer probe. Lift the probe housing and turn it up. Locate the appropriate probe from the dryer nozzle and disconnect the tubing. Pull the lever back to release the probe from the probe housing. Discard the probe, spring, and nozzle. Per lab protocol, locate the new dryer nozzles, probe, and spring. Insert the nozzle into the probe until it clicks into place. Insert the spring into the probe. Insert the probe into the probe housing until it clicks. Turn the probe housing over and reinsert it. On the analyzer, tighten the clamping screw clockwise, connect the 5-6 mm tubing to the probe, peel off the paper towel, and close the back cover. To exit diagnostics, select and continue in the software. Then select close. Select x trignostx. Then select Yes. To mark the procedure as complete, select menters. On the browser screen, select or activate is. Set the module filter to the appropriate CH analyzer. Select the correct probe from the cerrado nozzle. Select complitted marks. Finally, select Yes. To complete the procedure, perform the CH autocheck in the operator's diagnosis.

27 28 11 13 18 21 22 25 26 29 30 31 10 14 16 17 20 23 24 12 7/22/2021 7/17/2021 15 6/30/2021 19 8/25/2021 6/39/2021 8/13/2021 Substituindo as Sondas do Bocal do Secador no analisador Atellica® CH Este vídeo mostrará as etapas de como substituir as sondas dos bocais do secador do analisador químico Atellica CH. Para substituir Healthineers Atellica Solution Troubleshooting System SH-01 IM-01 Current Status Day Needs Tools Samples STATs Sample Interventions Supply Needs Worklist 1 STATs Intervention Needed 1 Routine Patients Reagent Needs Calibration Results 1 STATs Inprocess 0 Calibration 0 QC Maintenance QC Statistics Calibration Due Assay Status 5 Kg Inprocess: CH-02 Errors QC Needs Guided Workflows Activity Failed Warnings 8 Activities Due < 1 2 3 as sondas dos bocais do secador, o sistema deve entrar em estado de diagnóstico. Para comecar, selecione Troubleshooting. Em seguida, selecione Operator Diagnostics Ticketing Operator Event LIS Log Select Troubleshooting options from the left Operator Diagnostics. Selecione o módulo do analisador Select a Module ... CH1 Subsystems Diagnostic Name Activity Description Perform Unlocks the CH cover and positions the probes in the up position. Manually replace the source lamp. Replacing the Source Lamp Cancel Lamp Unlocks the CH cover. Manually check the lamp coolant. Checking the Lamp Coolant Autocheck CH Autocheck Cuvette Emptying the Cuvettes Aspirates the fluid from the cuvettes. Mixer Unlocks the CH cover and releases the dilution ring. Manually Replacing the Dilution Ring Cuvette Segments IMT Unlocks the CH cover, releases the reaction ring, and lowers the reaction ring bath. Manually replace the reaction ring Replacing the CH Reaction Ring Cuvette Segments Inspect and Clean cuvette segments. Probes Unlocks the CH cover and positions the dilution mixer impeller in the up position. Manually replace the dilution mixer Replacing the Dilution Mixer Impeller Fluid Unlocks the CH cover and positions the mixer impeller in the up position. Manually replace the sample mixer impeller. Upon Replacing Sample Mixer Impeller completion, the system aligns the probe. Replacing the Reagent Mixer Impeller Replacing Reagent Mixer Impeller IMT Dilution Check Performs IMT Dilution Check Primes All Enter Diagnostics? up position. Manually replace the sample mixer impeller. Upon Replacing Sample Mixer Impeller CH apropriado no menu na parte superior da tela. Log Selecione Enter Diagnostics. Depois, selecione Yes. Unlocks the CH cover and positions the probes in the up position. Manually replace the source lamp Checking the Lamp Coolant ally check the lamo coolant Autocheck Check Confirmation Yes No Message Log Online Help Description Service support Request Prime IMT Diluent Prime Salt Bridge Prime Standard A Replacing the IMT Peristaltic Pump Tubing Unlocks the CH cover and pauses the IMT. Manually replace the IMT peristatic pump tubing Cleaning the Reagent Loader Unlocks the CH cover and initializes reagent loader. Manually clean the reagent loader Cleaning the System Fluids Drawer The automatic system fluids cycling stops. Manually clean the system fluids drawer Cleaning the Washer Probes Unlocks the CH cover and positions washer probes in up position. Manually inspect the washer probes Inspecting the Washer Probes Aguarde até que o módulo entre no estado de diagnóstico. Replacing the Sample Probe Unlocks the CH cover and positions the sample probe in the up position. Manually replace the sample probe. Upon completion, the system primes and aligns the probe Replacing the Dilution Probe Unlocks the CH cover and positions the dilution probe in the up position. Manually replace the dilution probe. Upon completion, the system Replacing the Reagent Probe 1 Unlocks the CH cover and positions the reagent probe in the up position. Manually replace Reagent Probe 1. Upon completion, the system Replacing the Reaction Wash Probe 1 Unlocks the CH cover. Manually replace Reaction Wash Probe 1 Replacing the Reaction Wash Probe 5 bing Unlocks the CH cover. Manually replace Reaction Wash Probe 6 ean the reagent loader Replacing the Dilution Wash Probe 1 Unlocks the CH cover. Manually replace Dilution Wash Probe 1 Unlocks the CH cover. Manually replace Dilution Wash Probe 3 on, Manually inspect the washer probes Assay No tópico subsistemas, selecione Probes. Selecione Substituir LabManager View Status Replacing the Reaction Wash Probe Dryer Unlocks the CH cover. Manually replace the reaction wash probe dryer Replacing the Dilution Wash Probe Dryer 1 Replacing the Reaction Wash Dryer Nozzle Unlocks the CH cover. Manually replace the reaction wash dryer nozzle a Sonda de Secagem de Diluição, ou Substituir a Sonda de Secagem de Reação. Lampct and Clean Probes eck Selecione Perform. Depois, selecione Yes. Probe 5 Perform: Replacing the Reaction Wash Probe Dryer? Probe 6 Probe 1 Probe 2 ? Q Aguarde que o analisador se prepare para a manutenção. Replacing the Reaction Wash Pr ... Preparing system for Replacing the Reaction Wash Probe Dryer Close As tampas são destravadas automaticamente. Quando destravada, a tampa trava automaticamente, a menos que o operador abra ou remova a tampa dentro de 30 segundos. Abra a tampa traseira do analisador CH. Se a tampa for travada antes de você poder abri-la, selecione o botão na área status do sistema para destravar a tampa traseira. Há uma sonda do bocal do secador para o anel de reação, e outra sonda do bocal do secador para o anel de diluição. As 2 sondas dos bocais dos secadores são intercambiáveis. Antes de começar a remover uma das sondas do bocal do secador, cubra as cuvetes com um papel toalha para protegê-las de detritos. Desatarraxe o conjunto da carcaça da sonda no sentido anti-horário. Para acessar a sonda do secador, levante a carcaça da sonda e vire-a para cima. Localize a sonda apropriada do bocal do secador e desconecte a tubulação. Puxe a alavanca para trás para liberar a sonda da carcaça da sonda. Descarte a sonda, a mola e o bocal por protocolo de laboratório. Localize os novos bocais do secador, a sonda e a mola. Insira o bocal na sonda até que ela se encaixe. Insira a mola na sonda. Insira a sonda na carcaça da sonda até que ela faça um clique. Vire a carcaça da sonda e volte a inseri-la no analisador. Aperte o parafuso de aperto no sentido horário. Conecte a tubulação de 5-6 mm na sonda. Retire o papel toalha. E feche a tampa traseira. Para sair do diagnóstico, selecione Support Replace the Reaction Wash Probe Dryer: 1. Refer to the online help for the procedure: Replacing Reaction Wash Probe Dryer. 2. After completing the procedure, select Continue Unlock Covers Continue Unlocks the CH cover, Manually replace the dilution wash probe dryer Unlocks the CH cover. Manually replace the dilution wash dryer nozzle Exit Diagnostics? Continue no software. Em seguida, selecione Close. Selecione Exit Diagnostics. Em seguida, selecione Yes. SH-02 Para marcar o procedimento como completo, selecione Status Calibration 0 Activity Failed Maintenance na tela do navegador. Selecione All Activities. Filters: View By CH1-SCI1 By Count Due Now July 2021 Related All Activities Tx Clear Frequency : Daily X Activity Frequency Day Week Module IMT Daily Cleaning CH Daily Maintenance IM Autocheck VMM Atellica Magline Transport Autocheck SH Autocheck Daily All Activity Type Activity Status Maintenance Log Module : CH1-SCI1 X Clear Last Performed View Detalls Mark as Completed CH Maintenance Procedure Details CH Weekly Maintenance Search Cleaning the CH Cuvettes Cleaning the CH Fan Filter Draining and Filling the Reaction Ring Bath Inspecting and Cleaning the CH Probes and Mixer Impellers Inspecting and Cleaning the Probe Wash Stations Defina o filtro do módulo para o analisador CH apropriado. Sunday Monday Selecione a sonda correta do bocal do secador. Replacing the Reaction Wash Probe 2 Replacing the Reaction Wash Probe 4 Replacing the Reaction Wash Probe 5 Replacing the Reagent Probe 2 Selecione Mark as Completed. Por fim, selecione Yes. Complete the maintenance activity 1'Replacing the Reaction Replacing the Reacti Exit Diagnostics Para completar o procedimento, realize o autocheck CH no diagnóstico do operador. Por favor, observe que este material é destinado apenas para fins de treinamento! Para o uso adequado do software ou hardware, use sempre o Manual do Operador ou as Instruções de Uso emitidos pela Siemens Healthieers. Este material deve ser utilizado apenas como material de treinamento e não substituirá de forma alguma o Manual do Operador. Qualquer material usado neste treinamento não será atualizado regularmente e não reflete necessariamente a versão mais recente do software e do hardware disponíveis no momento do treinamento. O Manual do Operador deve ser usado como referência principal, em particular para informações relevantes de segurança, como avisos e precauções. Nota: Algumas funções mostradas neste material são opcionais e podem não fazer parte do seu sistema. Certos produtos, reclamações ou funcionalidades relacionadas aos produtos podem ainda não estar disponíveis comercialmente em seu país. Devido a requisitos regulamentares, a disponibilidade futura das referidas Funcionalidades em qualquer país em específico não é garantida. Por favor, entre em contato com seu representante de vendas local da Siemens Healthineers para obter as informações atuais sobre o assunto. A reprodução, transmissão ou distribuição deste treinamento ou de seu conteúdo não é permitida sem autorização expressa por escrito. Infratores serão responsabilizados por danos. Todos os nomes e dados de pacientes, parâmetros e designações são fictícios e apenas exemplos. Todos os direitos, incluindo direitos criados por concessão de patente ou registro de um modelo de utilidade ou desenho, são reservados. C Siemens Healthcare GmbH 2024 SIEMENS

  • atelica
  • attellica
  • attelica
  • manutenção
  • manutenção conforme a necessidade
  • conforme a necessidade
  • substituição
  • sondas
  • bocal
  • secador
  • ch
  • quimico