Siemens Healthineers Academy
NAEOTOM Alpha  Modes d'acquisition  Vidéo

NAEOTOM Alpha Modes d'acquisition Vidéo

Cette vidéo vous présente les modes d'acquisition disponibles sur le scanner NAEOTOM Alpha.
Il est préférable de visionner cette vidéo sur une tablette, un ordinateur portable, un ordinateur de bureau ou un moniteur connecté. Le visionnage de ces informations sur un smartphone est déconseillé.

10 SIEMENS . Healthineers NAEOTOM Alpha Scan Modes HOOD05162003331316 Unrestricted @ Siemens Healthineers, 2023 to the Video Coming up in this video: Introduction to the Video NAEOTOM Alpha Scan Modes · Scanner overview · Scan Modes on NAEOTOM Alpha NAEOTOM Alpha: NAEOTOM Alpha Scanner Overview . Dual Source with 2 x 6 cm Quantamax photon counting detectors · 2x Vectron tubes with 120 kW power each · Up to a 0.25 s rotation time · Up to a 66 ms temporal resolution · Flash scan mode up to 737 mm per second · Scan mode Highresultra with a 0.2 mm Collimation and 0.2 mm Slice Thickness · 82 cm bore size Scan Modes Ipha Scanner Overview 1. Select Protocols 2. Modify Protocols Scan Modes on NAEOTOM Alpha: 3. Confirm Changes Protocol Scan Favorites General Scan Dos Recon Favorites General Recon Recon&GO Find/Replace Scan/Recon Decis on ... Topogram ScanplanningTopoAdultSn Brain RoutineSpiralAdultHead RoutineSpiralAdultHeadHighresplus RoutineSequenceAdultHead RoutineSequenceAdultHeadHighres . Scan Mode concept on NAEOTOM Alpha is the same as any other Somaris X scanner. · Scan Mode name reflects basic technical and clinical properties of the scan mode e.g. . The Scan Mode name is composed of key words, like: Routine Spiral Adult Head . The combination of these key words applies the Scan Mode to its clinical use Scan Mode Key Words ScanplanningTopoAdultQuantumSn Spectral image acquisition (QuantumPlus, Quantum) phigh spatial resolution RoutineFlashSpiralAdult Thorax Quantumplus X-CARE RoutineSpiralAdultThorax Highresultra Quantumplus On Somaris X, we have Scan Mode Key Words to support and control the dimensions like: Sn filter Flash RoutineSpiralAdultThoraxQuantumSnHighresultra etc. Ro Scan mode naming structure: Scan Modes Categories Specific scan Modes for NAEOTOM Alpha CardiacDualsourceSpiralAdultAngioBisegmentQuantumplus CardiacDualsourceSequenceAdultAngioFlexQuantumplus · Each scan mode is broken down into specific categories. . The first category names the purpose of the scan range. . The next category of the scan mode depicts the scan type CardiacDualsourceSequence dultAngioFlexQuantumplus scan type. . The following category of the scan mode is the patient type. · Another category is the organ type, which indicates the body region that will be scanned. This category controls the specific dose and dose curves applied to the body region selected. . The spectral category represents the acquisition to be used during the examination and the recon possibilities: · Quantumplus = 120kV / 140kV · Quantum = 70kV / 90kV (e.g. all child protocols) · QuantumSn = Sn100kV / Sn140kV The scan option category provides additional information (ex. Highresultra) . Note in NAEOTOM Alpha routine scans have a 144 x 0.4mm collimation up to 3.2 pitch and Highresultra provides 120 x 0.2mm collimation with pitch up to 1.0 in routine and 3.2 in Flash mode Quantumplus The Spectral Dimension. Quantumplus and Quantum Protocol: Thorax [factory] Modes: -Indications: masses, tumor, metastases, lymphoma, lymph nodes, tuberculosis, empyema, infection, early visualization of pulmonary nodules, Thorax -Scan modes: Quantumplus Scan mode: e.g. RoutineSpiralAdultThoraxQuantumplus · Quantumplus is NAEOTOM Alpha signature mode. · Tube voltages 120 kV and 140 kV to ensure full spectral capability · Full spectral capability: · MonoenergeticPlus keV images · VNC / PURE Lumen Protocol: Lung Low Dose [factory] -Indications: early visualization of pulmonary . Quantum is a spectral mode with limited spectral information Scan modes: RoutineSpiralAdultThoraxQuantum Lung -Decision Tree: Lung Low Dose breathhold and X- CARE [factory] Example: RoutineSpiralAdultThoraxQuantum · Low tube voltages (70 kV / 90 kV) · Basic spectral capabilities: · MonoenergeticPlus keV images up to 130keV . No SPP, VNC, PURE Lumen or lodine Maps . QuantumSn is used for low dose scanning with tin filter (e.g. for Lung) · Tube voltages Sn100 kV or Sn140 kV. · MonoenergeticPlus images from 60keV and higher Exam Designer Scan Recon Back to Exam Designer Scan Protocols Filter by: Patient Type all Contrast Protocol Protocol Type Clinical Search Protocols: Enter protocol name or description. Decision Tree all Technique Show: Factory Protocols (168) Customer Protocols (117) Child Head (13) Neck (2) Brain [factory] Neck [factory] Brain Multi Phase [factory] Neck Alt [factory] + Add folder Brain Hemorrhage Post Interv ... Brain Perfusion [factory] Thorax (8) Brain Perfusion Prolonged [fa ... Brain Death Diagnostic [facto ... Thorax [factory] Trauma Inner Ear [factory] Thorax Alt [factory] Inner Ear Alt [factory] Thorax Dynamic [tactory] Specials Sinus [factory] Thorax and Abdomen [factory] Sinus Alt [factory] Thorax and Abdomen Multi P ... R Research Orbit [factory] Orbit Alt [factory] Lung Screening [factory] Intervention Dental [factory] Lung Low Dose [factory] Reset Selection Unhide Delete Export Import Modify Protocols Scan Adult Routine Protocols use Quantum Plus Baby Adult Alt Protocols use Quantum Modes. Alt Protocols are hidden by default. Unhide protocols to be used. Shoulder [factory] Brain Multi Phase Alt [factory] Thorax (4) Thorax and Abdomen Alt [fac ... Abdomen (6) Abdomen [factory] Abdomen Alt [factory] Abdomen Multi Phase [factory] Abdomen Multi Phase Alt [fac ... Whole Body [factory] Whole Body Alt [factory] 2022.04.27-09:27:00-DST-Trauma 2022.04.27-09:27:00-DST-1.3.12.2.1107 ... Child Routine Protocols use Quantum. Head (9) Shoulder (2) Brain Alt [factory] Shoulder Alt [factory] Child Alt Protocols use Quantum Plus. All are hidden by default. Child Alt Protocols . You can use these Child Alt protocols to scan with full spectral imaging for pediatric cases. . The full range of spectral reconstructions is available. · Multi Energy, DE Parallel, Radial Ranges, and SPP reconstructions available. Image Impression | Recon Box Physio Recon Auto Tasking Inline Options Spectral Recon Inline Results Multi Recons Thorax 5.00 Br40 Q3 cor Thorax 5.00 Br40 Q3 ax None Orientation ... Monoenergetic Plus VNC lodine Pure Calcium Pure Lumen Applications DE Parallel Ranges DE Radial Ranges SPP Highest Spatial Resolution: Protocol: Lung Screening [factory] - High Res · Highresultra shifts the limits of image resolution. Example: RoutineSpiralAdultThoraxQuantumSnHighresultra e.g. RoutineSpiralAdultThoraxQuantumSnHighresultra -Decision Tree: Lung screening [tactory] High Resolution Scan mode: High Resolution · Highest spatial resolution of 0.2 mm . Kernel sharpness up to Br98 . No dose is lost in a UHR-Comb: High resolution achieved by the ultra fine pixels of the photon counting detector. · Spectral capabilities possible in standard resolution: · Spectral results down to 0.4mm slice thickness and kernels up to 76 sharpness All high-resolution reconstructions of 0.2mm or kernel sharpness above 76 will be a T3D image. FlashResolution Protocol: TAVI [factory] High Pitch Scan Modes:on: -Indications: TAVI/TAVR, the evaluation of the access route (peripheral, transapical, subclavian, Routine Flash Modes are highest pitch scans for Routine transaortic), aortic root and aortic annulus Test Bolus dimensions, as well as aortic valve structure and Valve opogram exams. calcification, w CM TAVI Planning TestbolusSequenceAdult2dQuantum, RoutineFlashSpiralAdultAngioBodyFastQuantumpl us -Decision Tree: Patient Instruction TAVI [factory]; Test Run [factory] -Contrast Protocol: CTA [factory] -Indications: pulmonary embolism, visualize the iodine enhancement in pulmonary vessels, visualize and quantify the iodine uptake of the lung parenchyma, w CM s. Premonitoring -Scan modes: PremonitoringSequenceAdult2dQuantum, Monitoring CTA Pulmonary -Contrast Protocol: Pulmonary CTA [factory] Flashac Valve Protocol: Pulmonary CTA [factory] · Scans with very high pitch and scan speeds of 737 mm per second . Can be combined with ECG triggering e.g. aortic dissection · Untriggered Routine mode e.g ., for lung imaging · RoutineFlash modes: pitch between 1.0 and 3.2 · Flash mode can be used with Quantumplus mode, giving full spectral information and Dual Energy results at very fast scan speeds High Pitch Scan Modeston Scan Modes for Cardiac Con Cardiac High Temporal Resolution Scan Modes for Cardiac scanning: CardiacFlashSpiralAdultAngioQuantumplus, Protocol: Coronary CTA Function [factory] -Indications: identification, quantification of calcified lesions in the coronary arteries, wo CM; stenosis of the coronary arteries. w CM Calcium Scoring MonitoringSequenceAdult2dQuantum, CardiacDualsourceSpiralAdultAngioQuantumplus CTA Coronary -Decision Tree: Coronary Calcium Scoring HR variability [factory], Coronary CTA HR variability and HR Function [factory] Cardiac Dualsource Modes: · Example: CardiacDualsourceSequenceAdultQuantumplus · Scans with very high temporal resolution: 66ms · Cardiac with ECG triggering Standard low pitch Cardio Spirals and Cardiac Sequence modes. Cardiac Flash Modes: Cardiac Flash modes with high pitch 3.2 Ftex 4D Spiral Flex 4D Spiral: This acquisition mode allows for true volumetric perfusion imaging beyond the detector width. It can be used for neuro perfusion imaging, e.g. in case of stroke, as well as for body perfusion imaging, e.g. in case of liver tumors, and also for dynamic angiography examinations, e.g. of the lower extremities. Z Extremity Dynamic CTA [facto ... Z Liver Perfusion [factory] Extremity Dynamic CTA Alt [fa ... Kidney Stones [factory] Protoc Colon Low Dose [factory] Vascular Head (8) Brain CTA [factory] Brain CTA Alt [factory] -Scan m Thorax CTA [factory] Z Brain Dynamic CTA [factory] Thorax Dynamic CTA [factory] Brain and Neck CTA [factoryl Brain and Neck Dynamic CTA ... Pulmonary Artery CTA [factory] Pulmonary Artery CTA Alt [fac ... Abdomen (8) Vascular Extremities (4) Extremity CTA [factory] Extremity CTA Alt [factory] Thorax Dynamic [factory] Vascular Thorax (8) Thorax CTA Alt [factory] Brain Dynamic CTA Alt [factory] Thorax Dynamic CTA Alt [fact ... Brain and Neck CTA Alt [factory] Thorax Coronary CTA [factory] Thorax Coronary CTA Alt [fact ...

  • alpha
  • naeotom
  • neotom
  • photon
  • ct
  • routine
  • spiral
  • séquence
  • adulte
  • tête
  • hauterés
  • plus
  • xcare