Z Axis Alignment of the Endometrium Job Aid

This document describes the Z axis rotation method of the multiplanar rendering (MPR) used to align linear structures. This technique provides a localization technique for endometrial pathology, intrauterine devices (IUD), or the early gestational sac.

Z Axis Alignment of the Endometrium Job Aid Rotation of the multiplanar rendering (MPR) on the Z axis aligns linear structures providing a localization technique for endometrial pathology, intrauterine devices (IUD), or early gestational sac position. The following explains alignment using an endovaginal, 12 o’clock transducer orientation with the sagittal, anteverted uterus in the A plane. Acquisition (A) Plane Alignment Step 1 A B Select the A plane on the Touch Screen (outlined in orange on the image). C VR Step 2 Rotate the Color (Z) control aligning the endometrium horizonal. Align the endometrium on the long axis before obtaining the 3D data set. Centering the Area of Interest Step 1 Setup Press the Set key, located adjacent to the trackball, to select the Position function. Step 2 Align the endometrium on the horizontal plane on both the A and Position Size Curve B plane. SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Effective Date: 16 August 2021 | HOOD05162003201760 Job Aid | Z axis Alignment of the Endometrium Effective Date: 16 August 2021 | HOOD05162003201760 Slice Thickness and Width Step 1 Press the Set key to choose the Volume of Interest (VOI) Size function. The adjustable slice thickness box now has a dashed boundary. Step 2 Roll the trackball to adjust the height and width of the Position Size Curve VOI slice to include the fundus and lateral uterine borders. Step 3 Activate the A or B plane on the Touch ........ :: : : Screen. A white outline indicates the active plane, in this example, the B plane. Step 4 Press the Set key to activate Position, adjusting the slice thickness and width to include the entire endometrium. To increase structure differences (contrast resolution), increase the slice thickness. Adjusting the Curve - A and B Plane A B Use with a curved endometrium. - Step 1 C VR Select either the A or B plane from the Touch Screen. Step 2 Press the Set key to choose the Curve function. The adjustable plane displays as a dashed line with a triangular anchor point. Step 3 Roll the trackball front to back to adjust the curve and right to left for the volume cut plane. Step 4 Press the Set key to end the Curve function. SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Effective Date: dd mm 2021 | HOOD TBD Job Aid | Z axis Alignment of the Endometrium Effective Date: 16 August 2021 | HOOD05162003201760 C plane alignment Step 1 A B Select B or C plane on the Touch Screen. Step 2 C VR Press the Set key, located adjacent to the trackball, to select the Position function. Step 3 Roll the trackball to move the rotation point to the anatomy or pathology of interest. Step 4 Rotate the Z axis to align the endometrium horizontally. The red arrow on the A and C plane indicate rotation on the Z axis when using the B plane. Volume Rendering (VR) Alignment Step 1 A B Select VR on the Touch Screen. Step 2 C VR Press the Set key, located adjacent to the trackball, to select the Position or Size function. Step 3 Roll the trackball to center the anatomy or pathology of interest. Rotating the VR on the Z axis turns the volume left and right. SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Effective Date: dd mm 2021 | HOOD TBD Job Aid | Z axis Alignment of the Endometrium Effective Date: 16 August 2021 | HOOD05162003201760 References: Abuhamad, A.Z., Singleton, S., Zhao, Y., and Bocca, S. (2006). The Z Technique: An easy approach to the display of the midcoronal plane of the uterus in volume sonography. Journal of Ultrasound in Medicine. 25(5): 607-612. Wong, L., White, N., Ramkrishna, J., Araujo Júnior, E., Meagher, S., and Costa, F. (2015). Three-dimensional imaging of the uterus: The value of the coronal plane. World Journal of Radiology. 7(12): 484-493. Please note that the learning material is for training purposes only! Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available For the proper use of the software or hardware, please always use the in your country. Due to regulatory requirements, the future availabil- Operator Manual or Instructions for Use (hereinafter collectively “Op- ity of said Functionalities in any specific country is not guaranteed. erator Manual”) issued by Siemens Healthineers. This material is to be Please contact your local Siemens Healthineers sales representative used as training material only and shall by no means substitute the for the most current information. Operator Manual. Any material used in this training will not be up- dated on a regular basis and does not necessarily reflect the latest The reproduction, transmission or distribution of this training or its version of the software and hardware available at the time of the contents is not permitted without express written authority. Offenders training. will be liable for damages. The Operator's Manual shall be used as your main reference, in partic- All names and data of patients, parameters and configuration de- ular for relevant safety information like warnings and cautions. pendent designations are fictional and examples only. Note: Some functions shown in this material are optional and might All rights, including rights created by patent grant or registration of a not be part of your system. utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Healthineers Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Effective Date: dd mm 2021 | HOOD TBD

  • ACUSON Sequoia
  • Sequoia
  • 3D
  • 4D
  • gynecology
  • endovaginal
  • MPR
  • multiplanar rendering
  • volume of interest
  • VOI
  • VR
  • volume rendering