Siemens Healthineers Academy

VA20G SP01 MULTIX Impact Family What´s new Job Aid

This job aid provides you with an overview of the feature enhancements with the software VA20G SP01 for the following MULTIX Impact Family system: MULTIX Impact C and MULTIX Impact.
Target group: All users.
Recommended to be viewed on the following devices: All (incl. tablet, smartphone)

SIEMENS Healthineers MULTIX Impact and MULTIX Impact C VA20G SP01 What's New Job Aid Template Effective Date: 10 Aug 2023| HILS 2223 Job Aid Effective Date 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 Table of Contents SIEMENS Healthineers X-Ray Tube Touch User Interface (TUI) Layout 3 X-Ray Tube TUI – Patient Tab 4 X-Ray Tube TUI – Grad Status Information 5 User Interface – Device Information 7 Rejected Images 8 Static Tool in Postprocessing Mode 10 Image Processing Parameter Template 12 Disable Auto RIS Query 13 Rotation about Horizontal Axis (RHA) – Software Stop 14 Tube/detector auto tracking 15 Laterality Label (L/R) – Ortho Function Ortho Composed Image* 16 Auto Collimation for Single Long-Leg Examinations 17 Long Time Exposure 18 2 *This feature is available in all software versions above VA20D. Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 X-Ray Tube – Touch User Interface (TUI) Layout SIEMENS Healthineers With VA20G SP01, the layout of some icons is different on the X-ray TUI. The functions are the same. Doe, John ? Doe, John ? 19.11.1988 M 654789.345.678 19.11.1988 M 654789.345.678 Basic More Hand PA Basic More Position Hand PA 100 40 1 100 Medium Table MAS ms kV mAs ms #. Kay dose Dose - O mm Cu mm Cu O 1# DO 115 RHA: 0 RHA : 0 2| 115cm Current:115cm [IIII Desired: 115cm RHA:0º cm 115cm # 43 cm 3 * ACSS * # 43 cm # # 43 cm # * ACSS * # 43 cm # VA20 VA20G SP01 3 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 X-Ray Tube – Touch User Interface (TUI) Patient Tab SIEMENS Healthineers Once you press the RHA button to rotate the tube in VA20G SP01, the angle of rotation is now displayed in degrees on the Position tab card on the TUI. Henderson, Christopher 19.11.1988 M 654789.345.678 ? Hand PA Basic More Position Tube 90º 2| 115cm Current:115cm Desired: 115cm RHA:90 I --- DO 4 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 X-Ray Tube – Touch User Interface (TUI) Grid Status SIEMENS Healthineers Information Additional grid status information is now provided on the TUI. Doe, John ? Current: XXX Desired:XXX 19.11.1988 M 654789.345.678 Basic More Position Hand PA 40 KV 1 100 mAs ms Current: None Desired: none Kay Dose O mm Cu --- Current: unknown Desired: unknown 1 # DO 2| 115cm Il| Current:115cm [I] Desired: 115cm RHA:0º 1-to # 43 cm # * ACSS * # 43 cm ++ Current: removed 5 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 X-Ray Tube – Touch User Interface (TUI) Grid Status SIEMENS Healthineers Information Please note: The grid status information is highlighted in yellow when the actual grid status does not match the settings in the organ program. 'n' Doe, John 19.11.1988 M 654789.345.678 ? Basic More Position Hand PA 43x43 43×35 35×35 30×25 Kow 25x20 - SID + --- 8 A 1 System not ready[7/8] 2 115cm Current: none [|IlII Desired: 115cm RHA:0º --- DO # 43 cm # * ACSS * # 43 cm ++ 6 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 User Interface – Device Information SIEMENS Healthineers With VA20G SP01, the layout of the device information is different. Patient Information Patient Information Patient Name: ER 202012031230561, , Patient Name: ER 201809271411311 ID: ID: 202012031230561 201809271411311 bex: Sex Other Male Age: Age: 25Y DOB: DOB 1993-09-27 Accession No.: Accession No. 202012031230561 201809271411301 Device Information Device Information Grid Type: No Grid Current Grid: 180cm Grid Status: Grid_OUT Desired Grid: 180cm SID: 105cm SID: 300cm Collimator Size: 43.0cmx43.0cm Collimator Size: 35.0cmx43.0cm Collimator Alignment: Center Collimator Alignment: Center not reached Dose Information Dose Information Current DAP: 0.00uGy-m2 Current DAP: 0.00uGy-m2 Accumulated DAP: 0.00uGy-m2 Accumulated DAP: 0,00pGy-m2 7 VA20 VA20G SP01 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 Rejected Images SIEMENS Healthineers After image acquisition, you can accept or reject the image. 1. Tap the Reject icon to reject the image. 2. A dialog box appears, and you need to select a reject reason. Tap OK to Reject Reason X confirm. Tap Cancel to cancel the rejection of the image. Positioning PatientMotion Overexposed Underexposed AAntalActafort Positioning Cancel OK 8 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 Rejected Images SIEMENS Healthineers After an image has been rejected, the Reject icon appears on the rejected image thumbnail in the Patient List. Show Rejected Image needs to be enabled in the Service mode. The layout of the rejected images has been changed with VA20G SP01. Rejected images are only shown in View and Print mode. OGP List OGP List Chest PA Chest PA T Spine a.p. T Spine a.p. V VA20 VA20G SP01 9 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 Static Tool in Postprocessing Mode (1/2) SIEMENS Healthineers jerry 27.8 cm Institutil The view position and image laterality Process Flenor Setting Red Acquisition date:20 Patient Position and View quisition time are defined in the organ program. Label 154231 11992.01.11 X Operator L R T+ Ti AA Patient Position ho.:20220111113123 If the information is missing or not correct, windowing ? you can select the correct Patient auto T T W IT Position, View Position and Image Cropping not defined Laterality via the Static Tool in the view Position Postprocessing mode if required. adjust O not defined O AP O PA cm .. R .. lateral O oblique Click Save to save the changes. Image Laterality ,90 90 not defined O right O left O unpaired both Tool Static Tool EXI:250.00 Cancel OK :1219.67 Matrix sizen nGy.cm2 Filter Knee L AP Save As Sava ONE 10 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 Static Tool in Postprocessing Mode (2/2) SIEMENS Healthineers The following options are available in the Static Tool: Patient Position View Position Image Laterality You can set the View Position as follows Use the laterality information (Right R or Left L) Patient Position Abbreviation Symbol (depending on the examination): to label paired organs, e.g., hands. Head First - Supine HFS You can set the Image Laterality as • AP: Anterior-Posterior view PA: Posterior-Anterior view follows: Head First - Prone HFP • • Lateral: Lateral view Head First – Decubitus Right/R: For right organ HFDL • Oblique: Oblique view • Left • Not defined: No view is set • Left/L: For left organ Head First – Decubitus • HFDR Both (R+L): Paired organs, both shown Right • Unpaired: Unpaired organ • Feet First - Supine FFS Not defined: No laterality is set Feet First – Prone FFP Feet First – Decubitus FFDL T Left Feet First – Decubitus FFDR T Right 11 Effective Date: 26 Jun 2023HOOD05162003362196 not defined Unrestricted © Siemens Healthineers, 2023 Image Processing Parameter Template SIEMENS Healthineers With VA20G SP01, you can change the 09241, , 09241 ? Siemens Image processing parameter template Stitch View Print in Postprocessing mode under the Rad Name:ER 202212070909241, , 33.9 cm Institution name: Sex:O Acquisition date:2022-12-07 Process Flavor Setting Rad tab. ID:202212070909241 Acquisition time:09:24:56 Date of birth: Operator Siemens Thorax AP Age: Parameter S Request ID: Chest AP Accession no.:202212070909241 Set Propert Calcaneus Axial Click on the dropdown list and select Chest AP LUT Curve Typ Chest LAT one of the different user templates. Adjust Clavicle Contrast C-spine AP C-spine LAT Detail Elbow AP Latitude Elbow LAT Noise Femur Foot AP 41.5 cm WCShift WWShift Reset Params Save Params mAs:0.37 Reference EXI: 125.00 Current EXI: 1440.36 kV:125.1 DI:9.90 Matrix size:2281X2795 DAP:5.66gGy.m2 Filter type:NONE OGP name: Thorax AP WC: 1634 Grid typeinone WW:918 Save As Save 12 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 Disable auto RIS query SIEMENS Healthineers If you activate the Disable auto RIS query option, the DICOM Properties × Pre-registered Patients list will not be automatically General Sending Filming updated when the system switches to Patient mode. Worklist query Waiting time min To activate the Disable auto RIS query option you Specific Character Set English(ISO_IR 100) need to open the DICOM Properties > General Use Unicode (UTF-8/ISO_IR 192) for DICOM character encoding when entering Patient mode. Then select Yes. Select this only if it is supported by all systems in your local DICOM Network Disable auto RIS query when entering patient mode Yes Close study method Auto when entering patient mode Manually with dialog Storage commitment Prepare commitment 15 second Commitment timeout Hour Number of attempts 3 Apply Cancel OK 13 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 Rotation about Horizontal Axis (RHA) – Software Stop SIEMENS Healthineers Follow the instructions below to enhance the performance of the software stop in the VA20G SP01 version: 1TI Doe, John 19.11.1988 M 654789.345.678 ? • Press the software stop icon to activate the software stop. • Press the RHA rotation button to rotate the tube unit to a position Hand PA ±3° from the required detent (0° or ±90°). Basic More Position Remove your finger from the button but hold the tube handles for +3×43 43x35 5x35 30x25 • one second. The tube unit will be rotated automatically to the 25x20 detent. • The software stop is complete when the notification sound is triggered. Please note: - SID 115 cm + • The automatic rotation will be interrupted if any other tube 2| 115cm IlIII] Current: 115cm [I]] Desired: 115cm RHA:90º 1 -DO movement happens in the meantime. # 43 cm # * ACSS * # 43 cm # • Press the RHA button again to reactivate the function. 14 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 Enhanced tube/detector auto tracking SIEMENS Healthineers Doe, John 19.11.1988 M 654789.345.678 With VA20G SP01, you need to activate the auto tracking function for each Basic More Position standing examination on the Bucky Wall .20 Stand (BWS) independent of the 0º previous examination settings.* 15º HO DO 300 450 P 75º 009 06 Before VA20G SP01: If the auto tracking 2| 115cm [llI] Current:115cm # 43 cm # * ACS function was activated for standing Auto tracking button on examinations on the BWS, then the auto the Touch User Interface SIEMENS Healthineers .. tracking function was automatically still activated for all further standing Auto tracking button on the BWS (Recommend to use it together with Auto tracking button examinations. Up/Down button on the same panel) on the wireless remote control (if configured) *This feature is available in software versions VA20G and VA20G SP01. 15 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 Laterality Label (L/R) – Ortho Function Ortho Composed SIEMENS Healthineers Image* Institution name: L R Name: jone, , jone Sex: M quisition date: 2020-11-12 View Composing ID: 202011121355111 Acquisition time: 14:30:29 Date of birth: 1992-06-16 Operator: Mgr Tool Age: 028Y Request ID Accession no.: 2020111213551 This button enables the Drag and drop the Measurement laterality label function. label to the required Other functions in the Tool position in the image. Label and Measurement panels T. L R Ti AA are then disabled. AA E The laterality label is Adjust laterality label removed. size. mAs: 1.01 KV: Reference EXI: 250.00 Current EXI: 269.18 DI: 0.32 Matrix size: 3033x6832 DAP Filter type: NONE OGP name: Ortho_Finished WC: 1872 Grid type: NONE Save manual adj ments performed WW: 3136 *This feature is available in all software versions above VA20D. 16 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 Auto Collimation for Single Long-Leg Examinations SIEMENS Healthineers • The width of the single long-leg will be calculated and provided by an Search enhanced auto collimation algorithm. This basically enhances the workflow Body part All efficiency for those specific ortho examinations. Attribute * ID LongLeg single_w300_t130 (6-10yrs) • It is only available for systems with auto long-leg and full-spine collimation. Name LongLeg single_w300_t130 (6-10yrs) * Description LongLeg single_w300_t130 (6-10yrs) • To use auto collimation for single long-leg examinations, select SingleLeg in Acq mode DR RAD Ortho the drop-down menu Body part in the Single LongLeg organ program. Body part SingleLeg Anatomic ... Leg Image lat .. Not defined Image flip ... Image rot ... 90 180 . 270 Image label L R View posit ... Not defined 17 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 Long Time Exposure SIEMENS Healthineers The long time exposure function is available in software version VA20D and higher. Condition attribute Small Medium Large Exp mode 3pt KV 66 ms 2500 In the organ program editor, you need to select the 3-point technique (3pt) in the exposure mAs 80 AEC field 00 mode to set up a long exposure organ program. Dose Not defined Density Not defined The maximum exposure time is 3200 msec. Tube load 80% TOD 20 New Save Delete Apply Cancel 18 Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023 SIEMENS Healthineers Please note that this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information such as warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product-related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the latest information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com Effective Date: 26 Jun 2023HOOD05162003362196 Unrestricted © Siemens Healthineers, 2023

  • MULTIX Impact
  • Multix
  • Impact
  • Multix
  • Multx
  • Impac
  • MULTIC Impact
  • images
  • multix
  • impact
  • VA20G