Siemens Healthineers Academy

Using the SPP slider bar with dual energy spectral postprocessed monoenergetic reconstructions

With VB10 software on Siemens Healthineers CT scanners, the dual energy SPP slider bar, previously only available in View&GO, is now available in the MM RT Image Suite workflow using the following steps in this job aid.

Using the SPP slider bar with Dual Energy Spectral postprocessed monoenergetic reconstructions CT scanners with VB10; MM RT Image Suite With VB10 software on Siemens Healthineers CT scanners, the dual energy SPP slider bar, previ- ously only available in View&GO, is now available in the MM RT Image Suite workflow using the following steps: 1. Navigate to the local database and select a scanned dual energy study with a spectral postprocessed reconstruction. 2. Select the Open With icon near the top right of the screen and select MM RT Image Suite. Patient Browser Q More Filters C Lapor Results (31 results, 3:49:15 PM) Series · Favontes CT View&GO Patient Modality Study Date and Ti ... . Study Descripti ... Exported Study Archived Series Number A Series Description Modality I Instances in ... Sei Series Date an ... DE SPP RECON Topogram 0.60 Tr20 cor MM RT Image Suite CT 3/25/2025 3: *5/11/2001. Non-Contrast Head and Neck 1.50 Or40 A3 SPP ME70 CT 312 · Suggested 3/25/2025 3: SUDER BAR RT IMAGE SUITE Patient Protocol CT CT CaScoring 3/25/2025 3: CI. SR 3/25/2025 3:22:02 ... RTP Head and ... Dose Report Sa CT Dental 3/25/2025 3: 501 Examination Report CT Dual Energy 3/25/2025 3: 3. Once the study opens in MM RT Image Suite, select the SPP series (on the right side of the screen in the series navigator) with a left mouse click and drag it into the image layout area. Blue interactive text showing the current series type and keV energy will appear on the left side of each segment. MM RT Image Suite MM RT Image Suite Series 103 IMAn.a. FRMn.a. SP R8.7 103 IMA ~329 Non-Contrast Head and Neck 0.80 Qr40 A3 SPP_M 03/23/2025 SP F914.5 8:29:06 PM Non-Contrast Head and Neck 0.80 Qr40 A3 SPP_ME70 03/23/2025 3/23/2025 8:29:06 PM Structure Set_1 Favorite Tools UNAPPROVED Anatomy & Targets Structures POI Series Name R Mono+ keV 70 103 IMAn.a. FRMn.a. SP A135.0 Findings Non-Contrast Head and Neck 0.80 Qr40 A3 SPP. 03/23/2025 10cm 8:29:06 PM Favorite Tools F WAW W 250 LL + Note: A left mouse click on Mono+ will change the image type to Mixed, but to get the slider bar to appear, keep it selected on Mono+. Unrestricted | Published by Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 04/25/2025 | QR700021741 Healthineers Accessing the SPP Slider Bar 1. To access the SPP sider bar to view the images at various keV levels, navigate to the left of any image segment to the blue interactive text and right-mouse-click on the blue keV. The value (here 70) will be whatever Energy in keV the series was reconstructed in. X POI ... R Mono+ keV 70 2. The SPP slider bar will open next to the displayed image. Moving the slider to the left or right will change the keV, and the image contrast will change along with the different en- ergies. MM RT Image Suite X Dual Energy Mono+ Properties ? X 40 A3 SPP_ME70 70keV Anatomy & Targe Structures OK Cancel + o Name R Mono+ keV 70 Unrestricted | Published by Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 04/25/2025 | QR700021741 Healthineers Page 2 of 6 3. Clicking and dragging the slider to the left will increase the image contrast. Dual Energy Mono+ Properties ? X 47keV OK Cancel 4. Clicking and dragging the slider to the right reduces beam hardening and metal artifacts, which will also reduce image contrast. Dual Energy Mono+ Properties ? x 164keV OK Cancel Unrestricted | Published by Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 04/25/2025 | QR700021741 Healthineers Page 3 of 6 5. Once the desired keV energy is visualized, go back to the exam interface to make a new reconstruction at that energy. Navigate to the Recon Ranges on the left side of the screen, mouse-click on the first reconstruction, and select Repeat. Note: If the patient exam is closed, go to the patient browser, select the study, right-click the mouse, and select Recon at the bottom of the drop-down menu to re-open the exam. Select Reconstruction on the right side of the screen. .Open Pro CT VB10A Recon Ranges HFS Topogram Non-Contrast Head and Neck Show Parameters Delete Repeat Copy All Recon Parameters Copy Recon Volume Parameters Paste All Recon Parameters Paste Recon Volume Parameters 10cm Create Image with Reference Lines Send to CT View&GO Edit Result in CT View&GO 6. Right-mouse click on the newly created reconstruction, then select Show Parameters. SOMATOM go.Open Pro syngo CT VB10A Recon Ranges HFS Topogram Non-Contrast Head and Neck Show Parameters Delete Repeat Copy All Recon Parameters Copy Recon Volume Parameters Paste All Recon Parameters Paste Recon Volume Parameters Create Image with Reference Lines Send to CT View&GO Edit Result in CT View&GO Unrestricted | Published by Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 04/25/2025 | QR700021741 Healthineers Page 4 of 6 7. Navigate to the Inline Options tab and the Energy (keV) column (in this example, these pa- rameters are saved in Recon Favorites). Change to the desired keV, and select the Recon button on the left. SIEMENS DE SPP RECON X Healthineers 3/11/2001 (23) SLIDER BAR RT IMAGES MIM RT Image Suite ? RTP Head and Neck ... Recon Ranges Topogram Topogram Non-Contrast Head and Neck Reconstruction Patient Marking Non-Contrast Head and Neck Close Tools -- The Planning Base con-Contrast Head and Neck ancel Start reconstructions witch to Patient Marking tecon Favori ... General Recon Recon&GO Image Impression| Recon Box Physio Recon Auto Tasking |Inline Options ScanfRecon Slice Thickness Increme Next Cancel (men] window@ 120kv| Kernel FAST Planning FAST Planning Inline Results Multi Recons Energy [kev] Application Class [ Non-Contrast Head and Neck 1.50 0x40 A3 .50 11.00 Larynx Qr40 Neck - Neck Full SPP noenergetic Plus 8. Select the newly created SPP reconstruction and Export to the desired location (TPS). View&GO Print Open Open with DICOM Import Correct Delete Manage Recon OUR Raw Data Series Export (Ctrl+E) Series Number Series Description Modality #Instances in ... Series Archived Exported Series Date a ... 601 CT Raw data CT 3/23/2025 5: ... 1 Topogram 0.60 Tr20 cor CT To 3/23/2025 5: 2 Non-Contrast Head and Neck 1.50 Qr40 A3 SPP_ME70 CT 329 TO 3/23/2025 5: ... 3 Non-Contrast Head and Neck 1.50 Qr40 A3 SPP ME164 CT 329 To 3/23/2025 5: ... Unrestricted | Published by Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 04/25/2025 | QR700021741 Healthineers Page 5 of 6 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2025 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemens Shanghai Siemensstraße 3 40 Liberty Blvd. Medical Equipment Ltd. 91301 Forcheim, Germany Malvern, PA 19355-9998 USA 278 Zhou Shu Road Phone: +49 9191 18-0 Telephone: +1-888-826-9702 Shanghai 201318 siemens-healthineers.com Customer Care Telephone: P.R. China +1-800-888-7436 Telephone: +1 847 304 7700 Unrestricted | Published by Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 04/25/2025 | QR700021741 Healthineers Page 6 of 6

  • spectral
  • de post processed. ro