TSE MoCo - Turbo Spin Echo Motion Correction - USA

This pdf introduces you to the TSE MoCo -  Turbo Spin Echo Motion Correction technique, that employs a non-rigid elastic registration to consistently align the images before averaging.

SIEMENS Healthineers TSE MoCo - Turbo Spin Echo Motion Correction Job Aid Template Effective Date: 10 Aug 2021| HILS 2223 Effective Date: 09 Aug, 2022| HOOD05162003294634 Unrestricted © Siemens Healthineers, 2022 TSE MoCo SIEMENS Healthineers Table of Contents TSE MoCo 3 TSE MoCo - Activation 4 TSE MoCo - Prostate MRI 5 2 2 Effective Date: 09 Aug, 2022| HOOD05162003294634 Unrestricted © Siemens Healthineers, 2022 TSE MoCo SIEMENS Healthineers Challenge: Average 1 Average 2 Averaging can be used to increase Signal-to-Noise (SNR), but it can cause blur in moving organs. Solution: Turbo Spin Echo (TSE) motion correction is an image- based motion correction technique in the average- dimension for TSE imaging. The motion correction technique employs a non-rigid elastic registration to consistently align the images before averaging. Average 3 Sum of all Averages Note: This feature is already available for the HASTE sequence. With Software Version XA50 or higher it is also available for TSE and FAST_TSE. The HASTE sequence protocols are automatically converted. 3 Effective Date: 09 Aug, 2022| HOOD05162003294634 Unrestricted © Siemens Healthineers, 2022 TSE MoCo Activation You can activate TSE MoCo. This feature is 0 2:57 min Auto @ 3 0.3x0.3x3.0 mm3 ៛ 1.00 Routine Contrast Resolution Geometry System Physio Inline Sequence intended for use in prostate imaging. Part 1 Part 2 Assistant Introduction WARP 1. Click on the Sequence > Part 2 task card in the selected protocol. Phase Correction Automatic Red. EC Sensitivity 2. Click the Motion Correction dropdown Compensate T2 Decay menu and select Registration of Averages. Acoustic noise reduction Off Hyperecho Reduce Motion Sens. 3. Note: You can adjust the Motion Correction Motion Correction None setting in the myExam Cockpit or in the None Registration of Averages protocol loaded into the queue and changed on the fly prior scanning. 4 Effective Date: 09 Aug, 2022| HOOD05162003294634 Unrestricted © Siemens Healthineers, 2022 TSE MoCo – Prostate MRI SIEMENS Healthineers Here is an example showing the TSE MoCo mode compared to the traditional Default mode within Prostate organ examination. Without MoCo With MoCo With TSE MoCo you can reduce image blurring that would result from organ movement between averages. 5 Effective Date: 09 Aug, 2022| HOOD05162003294634 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 6 Effective Date: 09 Aug, 2022| HOOD05162003294634 Unrestricted © Siemens Healthineers, 2022

  • turbo
  • spin
  • echo
  • TSE
  • motion
  • correction
  • XA50