Siemens Healthineers Academy

Text Customization in MI View&GO

Text Customization in MI View&GO

Text Customization in MI View&GO Symbia Pro.specta™ systems VA10 and above Configuring Header Text 1. Launch MI View&GO and select a layout that has header text. Some layouts, such as Basic Display or Stack Layouts may not have headers. 2. Right-click on the header on top of the layout and select Configure Text. MI View&GO ¢ × Patient Name : Pro.specta^xSPECT Bone_T-Spine Patient ID : Tc99m MDP 25 mCi (918 ME Study Time : 1:07:00 PM Energy Window 1 : Tc-99m General Configure Text Basic Dynamic Static - Display Time Pro.specta, xSPECT Bone_T-Spine Tc99m MDP 25 mCi (918 MBq) NB - Dua tensity Plantar Volume Gated Stripe 3. In the new Configuration window, select and arrow in or out any attributes to be included in the text header. NOTE: If an attribute is selected, but no value appears, that field was left empty during registration or scanning. Configure Text ? x All Attributes Selected Attributes Acquisition Date Patient Name Acquisition Time Patient ID Contrast Agent Patient Birthdate, Sex and Age Dose in MBq Study Description Dose in mCi Study Date Exposure Study Time Exposure in uAs Accession Number Exposure Time Energy Window 1 Institution Name Energy Window 2 KVP Radiopharmaceutical Manufacturer Model Operators' Name Patient Birthdate Patient Sex and Age Referring Physician Series Description Study ID Display Identifying String OK Cancel Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Customizing Image Text 1. In MI View&GO, select Custom Text within Favorite Tools if Full Text is selected. To Full Text Text Distance Configur ... Line E Full Text Custom Text, Show/Hide Customized Image Text Hide T] 2. Select the Text Configuration tool in Favorite Tools. Ta Text Distance Configur Line Modify Reduced Image Text auto 3. In the new Configuration window that opens, the Image Type will default to the type of the opened or selected series, but may be changed in order to customize text based on image type. Configure Per Image Type NM WHOLE BODY NM STATIC Show All NM DYNAMIC NM GATED Patient Name NM WHOLE BODY Patient ID NM TOMO Birth Date, Patient's Sex and Age NM GATED TOMO NM RECON TOMO Time Point NM RECON GATED TOMO Study ID MI VOLUME STRIPE Study Date PET, CT, MR 4. Check all desired options for text attributes to appear on the layout. 5. Click OK. NOTE: If an attribute is selected, but no text appears, then that attribute field was not filled in during registration or scanning. Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Page 2 of 3 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthineers AG 2024 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemens Medical Solutions USA, Inc. Siemensstraße 3 40 Liberty Blvd. Molecular Imaging 91301 Forcheim, Germany Malvern, PA 19355-9998 USA 2501 N. Barrington Road Phone: +49 9191 18-0 Telephone: +1-888-826-9702 Hoffman Estates, IL 60192 USA siemens-healthineers.com Customer Care Telephone: Telephone: +1 847 304-7700 +1-800-888-7436 siemens-healthineers.com/molecular-imaging Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Page 3 of 3

  • customization
  • mi view&go