
CN-3000 and CN-6000 Systems Review QC Results Job Aid
This job aid describes how to review and manage QC results on the CN-3000 and CN-6000 Systems.
CN-3000 and CN-6000 Systems SIEMENS Healthineers Review QC Results Job Aid Details display Most recent QC button 1 result Review QC Results M 1, Menu Reagert Calib. curve QC char Order calib. Order QC Order STAT Joblist Maintenance Shutdown Reg new lot Tar/Limit Change Confirm dala Customize Read Output Export Dele 2 Assay group PT APTT Fibrinogen D-Dimer VIII IX XI XII APIX EDOX 1. Press QC chart on the Menu Current 2. Display QC charts by Assay group or QC file PT | sec Citrol 1 Lot 548099 17/03/2022 Review the QC results 10.8 sec N 3. 11.8 20 Mean 10.9 10.5 QC result within the defined limit range 19/06/2020 SD 0.07 • 9.2 16:41 CV 0.7 – x QC result outside the upper/lower limit PT I sec Citrol 2 lot 548285 04/09/2021 • – 31.1 27.2 sec N 20 but within the stop limits; warning Mean 27.7 27.0 19/06/2020 SD 0.55 QC result outside the upper/lower stop 22.9 16:41 CV 2.0 • – PT | INR Citrol 1 lot 548099 17/03/2022 limits; interrupted analysis error N 20 1.12 1.05 Mean 1.06 • Data information: 1.00 19/06/2020 SD 0.007 0.88 16:41 CV 0 .7 PT | INR 04/09/2021 Analysis result 2.75 - N 20 Analysis result count Citrol 2 lot 548285 Mean 2.80 2.98 2.75 - N 20 Mean 2.80 Analysis date/time 19/06/2020 SD 0.057 2.66 19/06/2020 SD 0.057 2.34 16:41 CV 2.0 16:41 2.0 40 plot 2 rrent 4. In the event of a QC failure, an audible and visual alarm will be generated CN-6000 II Read x Stop • If a QC result falls outside the upper/lower stop limits, sample analysis is interrupted and the Status display LED turns red Target/ Error search QC material Data limits button information information Note: Out of range QC should be repeated 1 before proceeding with sample analysis. Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021 CN-3000 and CN-6000 Systems SIEMENS Healthineers Review QC Results Job Aid Confirm data Control: Api Ctr1 Exclude data from Lot no.: 6805 automatic calculation Manage QC Results Assay parameter: Api-ng_mL Date/time: 2021/01/21 10:59:05 Search for QC errors: Result: 84 ng/ml 1. Press QC chart on the Menu Comment: 2. Press the Error search button • The QC chart with an error will be highlighted. Press the Error search button again to move to the next chart with a QC error Clear comment Add a comment and/or exclude QC results: 1. Press QC chart on the Menu OK Cancel 2. Select the QC point to be reviewed and press Confirm data 3. Add a comment and/or exclude the data from automatic calculation, if necessary QC file QC01/QC11 QC02/QC12 4. Press OK Comment: Reran to verify. HC • Comments appear in the top left corner of API-dOD the screen when the associated QC data point is selected 2 Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. Not available for sale in the U.S. Future product availability cannot be guaranteed. © Siemens Healthineers, 2021. All rights reserved. Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 3 Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021
- cn-3000
- cn-6000
- sysmex
- cn