This job aid describes how to peform the as needed maintenance task, LED calibration on the CN-3000 and CN-6000 Systems.

CN-3000 and CN-6000 Systems SIEMENS Healthineers Perform LED Calibration Job Aid 1 Perform LED Calibration – 00 123 P As Needed Maintenance Menu Reagent Calib. curve QC chart Order calib. Order QC Order STAT Joblist Maintenance Shutdown Rinse probes Execute Manual maint. Comment Cycle count Funct. Test Output Export Customize 2 LED calibration This month Press Maintenance > Execute > LED calibration Routine maintenance 1. LED lighting time: 0 hours Start LED calibration 3 Mon Tue Wed Thu Fri Rinse probes LED emission status 26 27 28 29 30 2. Review the details in the LED calibration dialog . . . Discard used cuvettes 405 nm 575 nm 660 nm 800 nm 340 nm Calibrate the HIL detector . . . . box Discard waste fluids Output 0% 0% 0% 0% 0% Check and discard the trap chamber f • If an error message appears regarding Shutdown Usable/unusable status . Clean the instrument (weekly) CH14 CH15 CH16 CH17 CH18 CH19 CH20 CH21 CH22 CH23 CH24 CH25 CH26 replacement of a part, please contact your Clean the rinse tank (weekly) Status V V V V V V V V V V V Mixing V V V V local Siemens service representative Clean the filters CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 Ref HIL 3. Press Start LED calibration Status V V V V V V V V V V V V V • LED calibration starts and a progress bar Mixing V As-needed mail A Error info: appears Pressure adjustment Prime 4. Once complete, press Close Remove the jammed cuvettes Wipe off the piercer Replace fuses of the pneumatic unit User-defined mainten Note: Document manual maintenance by User-defined maintenance 2 4 User-defined maintenance 3 Close 4 pressing Maintenance > Manual maint. > Register manual maintenance. CN-6000 W Ready Stop 1 Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. Not available for sale in the U.S. Future product availability cannot be guaranteed. © Siemens Healthineers, 2021. All rights reserved. Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 2 Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021

  • cn-3000
  • cn-6000
  • sysmex
  • cn