CN-3000 and CN-6000 Systems Monitor Supply and Reagent Inventories Job Aid
This job aid describes how to monitor supply and reagent inventories on the Reagent/consumables screen of the CN-3000 and CN-6000 Systems.
CN-3000 and CN-6000 Systems SIEMENS Healthineers Monitor Supply and Reagent Inventories Job Aid Reagent/consumables Screen Overview CN-COAGWASHER status Multiple selection mode Toolbar AM 51 Menu Reagent Calib. curve QC chart Order calib. Order QC Order STAT Joblist Maintenance Shutdown Replace Edit Reset Volume Re-estimate Aggregation CC/QC Settings Holder : A1-1 Reagent name No. of tests Remain. vol. Buffers APTT FSL Sequence CN-Wash A1-1 APTT FSL Item No. of Tests Usable volume 49.9 ml 13-10 TIHS PT-THS Reagent holder (150) Indicates CA Reagent holder No. of remaining test A1-2 number remaining 999 test FDP 594 JA1-2 Mixing A1-4 SHP (15) information area reagent volume Mixing not present Col Lot no APTT-FSL 999 ( 2 ) Reagent PT THS 527300 13-6 D4-2 hal type A1-7 Remaining SIRC3 ADP Fbe name DO Exp. date: 2019/12/20 D1-2 A34 AT3Sub A1-8 594 ( 2 ) QC 499 CAL number of tests Setting date/time Sal.PP 2018/12/20 13:56:17 Indicates QC No validated A1-9 Remaining stability time DJ-2 AT3 ( 50 ) 665 failure calibration Elapsed time LiaFDP2 595 A1-10 CAL XIII ch 498 curve D3-1 D2-2 Waste tank LiaFDP1 A2-10 595 VIII-FSL 999 Indicates order CAL A2-2 ADP2 A2-1 of use Rinse water Consumable 42-4 APTT nix 998 A2-6 ADP3 900 rash box Col3 information 0/ 1500 A2-9 A2-3 ADP1.0 Cuvette (C2345) LOT T THS B-1 Clean Il CA area OVB B-3 8-6 OVB SB cuvette OVB LiaDIL (B987) 0/40 Reagent table status area Reagent CA CLEAN II status information area 1 Effective Date: 18-Jun-2021| HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021 CN-3000 and CN-6000 Systems SIEMENS Healthineers Monitor Supply and Reagent Inventories Job Aid Reagent Holder Errors Symbol Error Possible Cause Action A reagent requiring mixing is installed Reagent table A – move the reagent to holder 2 in a reagent holder without mixing Reagent table B – move the reagent to position 1 function A buffer that requires refrigeration is Move the buffer to reagent table A installed on the buffer table A reagent other than buffer is installed Move the reagent to reagent table A or B Use prohibited on the buffer table A container other than SIRC1*, SIRC3*, Move the container to an inner holder of reagent rack C or GW5 or HBM1* is installed in an outer another reagent rack holder of reagent rack C A reagent other than factor-deficient Extract the reagent, move it to a container other than the SLD plasma, quality control materials or mini/micro Cup, and reset it calibrators is set in the SLD mini/micro Cup 2 * Sysmex reagent container Effective Date: 18-Jun-2021| HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021 CN-3000 and CN-6000 Systems SIEMENS Healthineers Monitor Supply and Reagent Inventories Job Aid Reagent Holder Errors (continued) Symbol Error Possible Cause Action Check for dirt or improper orientation of the barcode label, then Barcode read error Failed to read the reagent barcode reinstall the reagent container. If the error persists, enter the reagent information manually. If the error occurs with a reagent that has not been replaced, restore the reagent information Expired Reagent is past its expiration date Replace the reagent If the reagent name is not displayed, register the reagent name and LOT+ Unregistered reagent/ Reagent’s barcode ID or lot has not unregistered reagent lot been registered expiration date. If the reagent name is displayed, register the expiration date 3 Effective Date: 18-Jun-2021| HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021 CN-3000 and CN-6000 Systems SIEMENS Healthineers Monitor Supply and Reagent Inventories Job Aid Consumable Information Area Overview Black: Not full Red: Full Press to replace the waste fluid tank Waste tank X Black: Sufficient Black: Not full Red: Empty Rinse water Yellow: Warning Red: Full Trash box Press to reset the Black: Sufficient 0/ 1500 discard count Yellow: Low Red: Empty Cuvette (C2345) Indicates the amount of Menu Reagent Calib. curve QC chart Order calib. Order QC Order STAT SB cuvette (B987) Holder : A1-1 Reagent name No. of tests Remain. vol. Buffers SB cuvettes remaining APTT PS Sequence CN-Wash A1-1 APTT FS 0/40 Usable volume 49.9 ml A3-10 FT-THE No of remaining test 999 test FOR Mixing (is) Mixing not present Lot no APTT-FSL 527300 04-2 Vial type SIRC3 Exp. date: D4-1 2019/12/20 Setting date/time TO wide 2018/12/20 13:56:17 A3-3 Remaining stability time A3-2 Elapsed time LiaFDP2 CA Ea Waste tank Rinse water APIT vix 4 Trash box 0/ 1500 Cuvette (C2345) Effective Date: 18-Jun-2021| HOOD05162003199986 Clean& SB cuvette Unrestricted © Siemens Healthineers, 2021 0/40 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. Innovin and all related marks are trademarks of Siemens Healthineers. Any other trademarks are the property of their respective owners. Not available for sale in the U.S. Future product availability cannot be guaranteed. © Siemens Healthineers, 2021. All rights reserved. Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 5 Effective Date: 18-Jun-2021| HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021
- cn-3000
- cn-6000
- sysmex
- cn