
CN-3000 and CN-6000 Systems Maintenance Screen Overview Job Aid
This job aid describes the Maintenance screen of the CN-3000 and CN-6000 Systems.
CN-3000 and CN-6000 Systems SIEMENS Healthineers Maintenance Screen Overview Job Aid Maintenance Screen Overview 123 Eo Menu Reagent Calib. curve QC chart Order calib. Order QC Order STAT Joblist Maintenance Shutdown Rinse probes Execute Manual maint. Comment Cycle count Funct. Test Output Export Customize A. Displays 3 months before and after the current year/month A 2021/02 G This month Routine maintenance Mon Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Sat Sun Mon Tue Wed Thu Fri Sat Sun B. Daily and weekly maintenance B Daily/ (weekly ) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Rinse probes V . . . • Executed Discard used cuvettes Discard waste fluids • To be executed Check and discard the trap chamber fluid . . • Not executed Shutdown Clean the instrument (weekly) C. Monthly maintenance Clean the rinse tank (weekly) C Monthly History D History 2 E jory 1 F Memo • Displays the implementation date and the Clean the filters last 3 occasions monthly maintenance was As needed Replace Start-up report performed As - needed maintenance History 3 History 2 History Memo Pressure adjustment D. As needed Prime Displays the implementation date and the Remove the jammed cuvettes • Wipe off the piercer last 3 occasions as needed maintenance was Replace fuses of the pneumatic unit User-defined maintenance 1 performed User-defined maintenance 2 User-defined maintenance 3 E. Replace • Displays the implementation date along with the cycle counts, maximum cycle counts and comments entered for the last 3 occasions the supplies were replaced F. Start-up report • Displays the dates, times and results of the last 100 self 1 tests Effective Date: 18-Jun-2021 | HOOD05162003199986 G. Displays the current month Unrestricted © Siemens Healthineers, 2021 CN-3000 and CN-6000 Systems SIEMENS Healthineers Maintenance Screen Overview Job Aid Enter a Maintenance Comment 123 Lo C Menu Reagent Calib. curve QC chart Order calib, Order QC Order STAT Joblist Maintenance Shutdown Rinse probes Execute Manual maint Comment Cycle count Func. Test Output Export 2021/02 This month 1. Press Maintenance Routine maintenance Mon Tue Wed Thu Fri Sat Sum Mon Tue Wed Thu Sat Sun Mon Tue Wed The Fri Sat Son Mon Tue Wed Thu Fri Sat 2. Highlight the maintenance item Daily((weekly) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Rinse probes 3. Press Comment Discard used cuvettes V 4. Press OK Discard waste fluids Check and discard the trap chamber fluid Shutdown ..... ..... Clean the instrument (weekly) Clean the rinse tank (weekly) ....... Monthly History Export Maintenance Logs History 2 History Memo Clean the filters As needed Replace Start-up report 1. Press Maintenance As-needed maintenance History 3 History History 1 Memo 2. To print, press Output > Print Pressure adjustment Prime 3. To output in PDF format, press Export > Remove the jammed cuvettes Wipe off the piercer PDF Replace fuses of the pneumatic unit User-defined maintenance 1 User-defined maintenance 2 User-defined maintenance 3 2 Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. Not available for sale in the U.S. Future product availability cannot be guaranteed. © Siemens Healthineers, 2021. All rights reserved. Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 3 Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021
- cn-3000
- cn-6000
- sysmex
- cn