CN-3000 and CN-6000 Systems Joblist Screen Overview Job Aid
This job aid describes how to view and manage samples on the Joblist screen of the CN-3000 and CN-6000 Systems.
CN-3000 and CN-6000 Systems SIEMENS Healthineers Joblist Screen Overview Job Aid Filter the List display area Toolbar Joblist Screen Overview LL AAA Reagent Calib. curve QC chart Order calib. Order QC Order STAT Joblist Maintenance Shutdown Graph Browse Iveform profile Edit data Validate Font size Customize Output Delete Menu Display Displays/hides Current day's quantity STAT/micro sample Not analyzed Not validated Not output to hc CO (1/2) O the Details conditions display area Assay Num Dilution ratio Analysis Start End Status V S Mode Sample No. Rack No. time time Date Hem Ict Lip Volume R CP Output Seq. Sa parameter status -pos. Complete 1912 B 000014-2 08:05 08:1 2020/05/27 GH 65 T sec 1 1/1 * 11.7 V Error 1913 000014-3 08:0 08:05 2020/05/27 GH 66 < Complete 1914 000014-4 08:05 08:11 2020/05/27 GH 67 PT R 1 1/1 * 1.06 < Complete V 1915 000014-5 08 : 0 08: 1 2020/05/27 GH 68 Complete V 1881 000015-1 08:01 98:12 2020/05/27 GH 69 Error V 1942 000015-2 08:07 08:07 2020/05/27 GH 70 Complete V 1943 000015-3 08:07 08:13 2020/05/27 GH 71 List display Complete V 1944 000015-4 08:07 08:13 2020/05/27 GH 72 A Complete V 1885 000015-5 08:08 08:26 2020/05/27 R GH Details display 73 B area Complete 2000 000016-1 08:09 08:15 2020/05/27 GH 74 area Complete S STAT-3-1 STAI 08:10 8:23 2020/05/27 GH 124 3 < Complete 1999 B 000016-2 8:18 08:24 2020/05/27 GH 75 < Complete 1998 000016-3 08:18 08:24 2020/05/27 GH 76 Complete 1997 000016-4 08:19 08:24 2020/05/27 GH 77 B 4 4000 < Review 1996 B 000016-5 08:19 08:25 2020/05/27 GH 78 3000- < Review 1893 B 000017-1 08 : 2 08:26 2020/05/27 GH 79 Error V 1894 B 000017-2 08: 2 08:30 2020/05/27 GH 80 2000 Complete V M 0001 M REAG00 08:21 08:28 2020/05/27 GH 135 1000 Error 1895 B 000017-3 08:21 08:29 2020/05/27 GH 81 Error 1896 B 000017-4 08:22 08:29 2020/05/27 GH 82 10 20 30 40 50 60 < < Display Sample info Analysis results Filter Sort Analysis start date and time(Ascending) = tabs .. .. 1 ->iii Displays the conditions of the Mark mode button Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021 current List display area CN-3000 and CN-6000 Systems SIEMENS Healthineers Joblist Screen Overview Job Aid Sample Info Tab: Analysis Status Analysis Tab: Analysis Progress/Results Display Meaning Display Meaning Pending Order is registered but analysis has not started V Not analyzed Processing Analyzing Sample aspiration in progress On Hold All analysis parameters have been calculated but the calibration curve has not been validated Incubation in progress Complete Analysis of all assay groups has been completed normally Measurement in progress Review Analysis completed but requires confirmation Waiting for re-analysis Error Analysis completed but an error has occurred R Incubation in progress (re-analysis) RD Measurement in progress (re-analysis) 2 Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021 CN-3000 and CN-6000 Systems SIEMENS Healthineers Joblist Screen Overview Job Aid Manually Validate a Result AAA C Menu Reagent Calib. curve QC chart Order calib. Order QC Order STAT Joblist Maintenance Shutdown Graph Browser Waveform profile Edit data Validate Font size Customize Output Delete SW Prfg All sample Specify date Z-Wert CD (2/2) 1. Press Joblist on the Menu 2. Select the analysis result to be validated Status V S Mode Sample No. Rack No. Start ASsay -pos. time End Analysis time Date Hem Ict Lip Volume R CP Output Seq. Sa parameter Num Dilution ratio status 3. Press Validate on the Toolbar Complete 1882 B 000101-2 14:50 15:00 2020/05/25 - GH 510| APTT sec 1 1/1 40.7 Complete 1943 B 000101-3 14:51 15:01 2020/05/25 - GH 511 < < Complete V 1944 B 000101-4 14:51 15:01 2020/05/25 GH 512 APTT R. 1/1 1.62 Complete 1885 B 000101-5 14:51 15:01 2020/05/25 GH 513 complete 1911 B 000102-1 14:52 15:01 2020/05/25 GH 514 AT dOD 1 1/1 0.809 < < Complet V 1912 B 000102-2 14:53 15:02 2020/05/25 GH 515 Complete 1/1 V 1913 46.2 B 000102-3 14:53 15:01 2020/05/25 GH 516 AT 9 1 Export Results Complete V S STAT-1-4 M STAT 14:54 14 . 59 2020/05/25 GH 553 Complete V 1914 B 000102-4 14:57 15:03 2020/05/25 GH 1 1/1 * 14.0 517 Fbg sec omplete V 1915 B 000102-5 14:57 15:14 2020/05/25 R GH 518 Fbg C. 1/1 122.0 Complet V 1989 B 000103-1 15:00 15:06 2020/05/25 GH 519 1. Press Joblist on the Menu Complete V 1990 B 000103-2 15:00 15:06 2020/05/25 GH 520 PT sec 1 1/1 15.0 Complete V 1991 B 000103-3 15:01 15:06 2020/05/25 GH 521 2. Select the analysis result to be exported Complete V B 000103-4 15.01 2020/05/25 GH 522 4000 1 To select multiple results utilize the V 1993 B 000103-5 15:01 15:07 2020/05/25 GH 523 • Complete 1893 B 000104-1 15:02 15:08 2020/05/25 GH 524 3000 mark mode button Complete 1894 B 000104-2 15:02 15:12 2020/05/25 GH 525 20001 Complete 1895 B 000104-3 15:03 15:09 2020/05/25 GH 526 3. To print, press Output > List print [Final < < < Complete 1896 B 000104-4 15:03 15:09 2020/05/25 GH 527 1000 analysis] OR List print [All analysis] Complete V 1897 B 000104-5 15:04 15:20 2020/05/25 R GH 528 10 20 30 40 50 60 4. To save a PDF, press Output > Save as Sample Filter info Analysis results Sort Analysis start date and time(Ascending) = Coagulation curve error: Sharp drop . .. PDF [Final] OR Save as PDF [All] CN-6000 5. To output to Host, press Output > Host Ready Stop Mark mode button 3 Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. Innovin and all related marks are trademarks of Siemens Healthineers. Any other trademarks are the property of their respective owners. Not available for sale in the U.S. Future product availability cannot be guaranteed. © Siemens Healthineers, 2021. All rights reserved. Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 4 Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021
- cn-3000
- cn-6000
- sysmex
- cn