CN-3000 and CN-6000 Systems Evaluate Calibration Results Job Aid

CN-3000 and CN-6000 Systems Evaluate Calibration Results Job Aid

This job aid describes how to view and compare calibration curves on the CN-3000 and CN-6000 Systems.

CN-3000 and CN-6000 Systems SIEMENS Healthineers Evaluate Calibration Results Job Aid Calibration curve status View Calibration Curves 1 2 Menu Reagent Calib. curve QC chart Order calib. Order QC Order STAT Joblist Maintenance Shutdown Edt Vaidate Compare Output Export Delete 1. Press Calib. curve on the Menu APTT APTT APTT AT DD Fbg FDP Hep LM Hep UF IX IX C) (1/3) 2. Select the desired analysis parameter Validated Fbg OVB 3. Select the reagent lot group Reagent lot group 565061 /- Fbg C 4 4. Review the calibration curve for each Current ID 0000001 _ sysmex 3 Log - Log Logistic r^2 = 1.000 sec Modify assay parameter, if applicable Exp. date: U LOT ] Calibrator information 100.0 2021/09/11 SHP 503278 2021/09/11 Cursor position Created on: 2020/09/11 10:43 50.0 X Validated on: 2020/09/11 10:54 126.5 Reagent lot group: .20.0 mg/dL Fbg /OVB 565061 Y: 10.0 mg/dl sec 14.2 Parameter 67.8 24.9 135.5 13.3 5.0 sec information 271.0 7.3 display area 406.5 5.2 542.0 4.1 2.0 20.0 50.0 100.0 200.0 500.0 1.0 Fbg C. a = -0.32412 -0.30154 C 14.71913 -2.93056 CN-3000 Processing Stop Dilution point Graph display 1 information Effective Date: 18-Jun-2021 | HOOD05162003199986 area display area Unrestricted © Siemens Healthineers, 2021 CN-3000 and CN-6000 Systems SIEMENS Healthineers Evaluate Calibration Results Job Aid 1 2 4 Compare New Versus Current Calibration Curve Menu Reagent Calb. Curve QC Chart Order calib. Order QC Order STAT Shutdown Ed! Validate Compa Fio Delete PT-THS FDP Fbg DD wide AT3 WWF-RCO XIll ch VIII-FSL PT-INN PT 1. Press Calib. curve on the Menu Not Validated Reagent Lot Group AT3Thro /AT3Subs /OVB 3 520100 /520200 AT3 % 2. Select the desired analysis parameter New Current Compare) 0000008 2. super Real - Real Linear r = - 1.000 (r = - 0.999) dOD Chng Range 3. Select the reagent lot group Exp. Date U CET E Calibrator Information T ET Exp. Date: y EST E Calibrator Information m^2 = 0.999 (+2 = 0.999) 2.000 ---- / -- / -- / ---- Cursor Position 4. Press Compare in the Toolbar Created on: Created on: 2018/10/16 21:55 2018/07/11 09:45 X: 5. Select the calibration curve to compare Validate: Validate: ..... 2018/07/11 12:49 1.500 75.0 6. Press OK À Reagent Lot Group: È Reagent Lot Group: ........... % AT3Thro /AT3Subs /OVB AT3Thro /AT3Subs /OVB • The calibration curve to be compared is 520100 /520200 520100 /520200 Y: 1.000 displayed in green doD doD 0.970 1.551 M 0.0 1.349 11.6 1.251 dOD • To cancel the comparison, press Compare > M 11.9 1.465 M M 23.8 1.359 M 23.3 1.140 Cancel comparison M 47.5 1.167 M 46.5 0.959 -0.500 Y (Compare) M 95.0 0.813 M 93.0 0.596 M 142.5 0.480 M 139.5 0.259 3.749 dOD 0.0 20.0 40.0 60. 80.0 100.0 120.0 140.0 0.000 AT3 % VA -7.55474 X 10^ b - 1.54297 CN-6000 Ready Calibration curve comparison New calibration Current calibration 2 Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. Not available for sale in the U.S. Future product availability cannot be guaranteed. © Siemens Healthineers, 2021. All rights reserved. Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 3 Effective Date: 18-Jun-2021 | HOOD05162003199986 Unrestricted © Siemens Healthineers, 2021

  • cn-3000
  • cn-6000
  • sysmex
  • cn