What's New job aid highlighting the new XA60 software found on the MAGNETOM Lumina and Vida systems. This job aid provides a comprehensive overview of the new features and software improvements that are incorporated in syngo MR XA60A.

MAGNETOM Vida, MAGNETOM Lumina Advance your Magnetic Resonance Imaging syngo MR XA60A – What’s New siemens-healthineers.us/mri SIEMENS Healthineers Dear MAGNETOM user, We are pleased to announce the arrival of our latest MRI scanner software, syngo MR XA60A. This new software version includes comprehensive improvements to the existing scanner functionalities and provides access to exciting new features. MAGNETOM MRI scanners that qualify for this software update include: • MAGNETOM Vida • MAGNETOM Lumina Learn more about syngo MR XA60A in this informative packet and discover how it can improve your daily routine. Sincerely yours, Your Siemens Healthineers MR team 2 Contents Contents 1. New sequences, protocols, and applications 4 1.1. Deep Resolve for EPI Diffusion 4 1.2. Deep Resolve for HASTE 5 1.3. BioMatrix Beat Sensor 6 1.4. Open Recon 7 1.5. Physiologging 8 2. Improvements to sequences, protocols, and applications 9 2.1. myExam Angio Advanced Assist 9 2.2. Improved VIBE Phase Encoding Order 10 3 syngo MR XA60A – What’s New 1. New sequences, protocols, and applications 1.1. Deep Resolve for EPI Diffusion Available for: MAGNETOM Vida, MAGNETOM Lumina Category: Optional feature Pre-requisites: High-end MaRS (Reconstruction system) What is Deep Resolve for EPI Diffusion? Deep Resolve Boost and Deep Resolve Sharp are now With Deep Resolve for EPI Diffusion, you can improve available for the EPI diffusion sequence. Deep Resolve image quality and lesion conspicuity, and reduce the Boost takes Deep Learning Reconstruction to the next acquisition time of your body diffusion scans. level with parallel imaging acceleration. The deep neural network behind Deep Resolve Boost enables effective Highlights and benefits: denoising that improves the signal-to-noise ratio of the • images. Deep Resolve Sharp is a novel image Deep Resolve boosts acquisition speed and image reconstruction technology to increase the sharpness in sharpness • the resulting images. The deep neural network at the Three levels of denoising strength • core of Deep Resolve Sharp generates a high-resolution Deep Resolve for EPI Diffusion can be combined image from low resolution input data. with SMS (Simultaneous Multi-Slice) to maximize acceleration • Perform a bi-parametric PI-RADS 2.1 prostate exam in less than 6 minutes with Deep Resolve T2w TSE with Deep Resolve DWI with ZOOMitPRO and Deep Resolve b800 Calc b2000 ADC 1:06 min 0:56 min 0:52 min 2:05 min 2aaaa2615 4 syngo MR XA60A – What’s New 1.2. Deep Resolve for HASTE Available for: MAGNETOM Vida, MAGNETOM Lumina Category: Optional feature Pre-requisites: High-end MaRS (Reconstruction system) What is Deep Resolve for HASTE? Deep Resolve Boost and Deep Resolve Sharp are now With Deep Resolve for HASTE, you can achieve available for the HASTE sequence. Deep Resolve Boost excellent image quality and diagnostic confidence and takes Deep Learning Reconstruction to the next level improve lesion detection for your HASTE body scan. with parallel imaging acceleration. The deep neural network behind Deep Resolve Boost enables effective Highlights and benefits: denoising that improves the signal-to-noise ratio of • the images. Deep Resolve Sharp is a novel image Enabling higher parallel imaging factors, resulting in reconstruction technology to increase the sharpness in substantially decreased scan times • the resulting images. The deep neural network at the Enabling shorter echo train durations and reduced core of Deep Resolve Sharp generates a high-resolution T2 blurring • image from low resolution input data. Reduce the acquisition time of your body T2-weighted scan by up to 90%, in a single breath-hold 90% faster O Original: Deep Resolve: MAGNETOM Vida MAGNETOM Vida Triggered BLADE Single breath-hold HASTE PAT 3, TA 1:56 min PAT 3, TA 0:23 min 0.9 x 0.9 x 6.0 mm3 1 x 1 x 6.0 mm3 7 Learn more Click here to learn more about Deep Resolve 5 syngo MR XA60A – What’s New 1.3. BioMatrix Beat Sensor Available for: MAGNETOM Vida, MAGNETOM Lumina Category: Standard for MAGNETOM Vida; Purchasable option for MAGNETOM Lumina Pre-requisites: BioMatrix Body 12 coil or BioMatrix Body 18 coil What is the BioMatrix Beat Sensor? Beat Sensor is a Siemens Healthineers unique break- BioMatrix Beat Sensor through technology which enables a complete cardiac for CMR exams without ECG MRI exam without ECG! BioMatrix Beat Sensor uses the heart’s own pulsatile motion as the triggering source, unlike ECG which only indirectly measures the onset of cardiac motion by detecting the electrical activity of the heart. Highlights and benefits: • The big benefit of BioMatrix Beat Sensor is that it eliminates the need to place electrodes on the patient and hence can speed up the workflow for CMR exams. • Technologists are happy because they don’t have to spend time shaving chest hair, using cleaning gel, and placing electrodes on patients. Beat Sensor Cardiac 63 min RR-1 94 945 ms • BioMatrix Beat Sensor triggering can also improve the patient experience especially for patients who have sensitive skin (e.g., allergic to cleaning gel) Beat Sensor triggering for ALL cardiac sequences: and/or feel uncomfortable when technologists place BEAT, BEAT_epi, BEAT_FQ, BEAT_FQ_nav, BEAT_map, the electrodes on their chests. CV_nav, fl3d_ce, HASTE, space_nav, trufi-freqScout, TSE. 1aaaa4056 • With BioMatrix Beat Sensor hospitals can save on supplies and reduce plastic waste. Courtesy: Dr. Johan Dehem, Jan Yperman Hospital, Ieper, Belgium 7 Learn more Click here to learn more about BioMatrix Beat Sensor 6 syngo MR XA60A – What’s New 1.4. Open Recon Available for: MAGNETOM Vida, MAGNETOM Lumina Category: Standard feature Pre-requisites: None Open Recon is a developer-friendly interface that With syngo MR XA60A, customized reconstructions facilitates the creation and deployment of innovative are possible both in image-to-image as well as in MR reconstruction algorithms. Open Recon opens raw data-to-image domain. the MR system for such FDA cleared algorithms to be deployed by scientists, 3rd party companies and Highlights and benefits: Siemens Healthineers. Different FDA cleared • reconstruction algorithms can be executed in a Simplified reconstruction environment for scientists. • container on the reconstruction system, exchanging Convenient access to reconstruction parameters via data via a dedicated interface. With Open Recon, custom dedicated “inline” card. • reconstruction algorithms can easily be run and adjusted, Facilitated scientific collaboration via the ISMRM enabling seamless workflow. Open Recon also facilitates raw-data format. • the sharing of FDA cleared algorithms across institutions Possibility of MR reconstruction algorithms deployment relying on the ISMRM raw data format. for third parties and SHS. USER > head >> Brain Assist > program >> t1_qtse_dark-fluid_sag_p2 General 3 4:38 min Auto @ 2 @ 0.7x0.7x4.0 mm3 1.00 Protocol Parameters Inline Use Routine Contrast Resolution Geometr System Physio Inline Sequence Voice Commands Execution Subtraction Run custom prototype image MIP Composing Open Recon reconstruction on the scanner Image Management Algorithm myRecon 1 Auto Load 3rd party or custom Copy References algorithm Preview Preset denoise Parameter 1 |Setting A Select 3rd party or custom Free Text denoise reconstruction algorithm to denoise-enhanced-level1 Parameter 2 Setting B mg be run denoise-enhanced-level2 denoise-enhanced-level3 Option 1 ............................... User-friendly interface super-resolution smooth-super-resolution Option 2 Adapt parameters provided by edge-super-resolution the algorithm like on any other super-resolution-gre-mpr tab card super-resolution-dwi The Open Recon tab can be found under “Inline”. 7 syngo MR XA60A – What’s New 1.5. Physiologging Available for: MAGNETOM Vida, MAGNETOM Lumina Category: Optional feature, included with Inline BOLD and/or 3D PACE Pre-requisites: Physiological sensors Physiologging enables the extraction of physio data via Highlights and benefits: a checkbox on the Physio > Signal tab of the UI. As a • new feature, time stamps are added to allow easier Timestamped physiological data for easier synchronization of physio data to corresponding fMRI synchronization with fMRI data • data acquired with either EPI BOLD or EPI PACE. This will Recording can be started via a checkbox on the UI help researchers to correct fMRI data for physiological (Physio > Signal tab) • motion and noise. All parameters recorded by internal Physio data are stored as a separate DICOM file physiological sensors (such as BioMatrix Respiratory which can also be archived Sensor, respiratory belt, ECG, pulse sensor, BioMatrix Beat Sensor) are then available in a convenient data format for further offline processing. The physio curves will be stored in a separate DICOM file including timestamps. 00:32 Access time-synced sensor data for fMRI scans as part of the DICOM study Sample code available for extraction Planned Available for EPI BOLD & PACE Physiologging Physiologging: Code samples for DICOM extraction The tools available at https://www.magnetomworld. In addition, a batch file using the siemens-healthineers.com/clinical-corner/ executable generated either from the application-tips/physiologging can be used to extract C# or the python code is provided the embedded xml structure from the DICOM file and (physioExtractor.bat) for generating restore the original text files containing the physio data. different types of text files, along with xsl style sheets defining the processing Provided are demonstration source codes in of the xml file. a) C# (physioExtractor.cs) and b) python (physioExtractor.py). 8 syngo MR XA60A – What’s New 2. Improvements to sequences, protocols, and applications 2.1. myExam Angio Advanced Assist Available for: MAGNETOM Vida, MAGNETOM Lumina Category: Included in purchasable option, myExam Angio Assist Pre-requisites: myExam Angio Assist What is myExam Angio Advanced Assist? all stations (abdomen, legs, feet) together in the GSP. myExam Angio Advanced Assist is a semi-automated After planning is complete, the angio pre-contrast workflow for peripheral MR angiography examinations data-acquisition is executed for all planned stations. with step-by-step guidance throughout the exam. With the care bolus step the arrival of the contrast agent This workflow support feature offers clear planning for is manually or automatically detected. Once the contrast all multi-station angiography exams by enabling the agent is detected the angio post-contrast measurement planning in the Graphical Slice Positioning (GSP) user is performed in accordance with the pre-contrast interface for all stations in one common planning step. measurement. Alternatively, the test bolus workflow can This new Assist workflow uses test bolus and care be used. Finally, an optional dynamic CE MRA (TWIST) bolus-functionality to optionally track the bolus arrival measurement can be performed in the vessels. Highlights and benefits: myExam Angio Advanced Assist provides workflow • support for peripheral MR angiography exams. After Automation and guidance for robust peripheral performing an overview scan, the relevant peripheral MRA exams • vessels and the aorta are localized. Then planning of the Easy planning with coverage boxes, overlap clearly actual angiography measurement is performed by using visible • the Angio Advanced Planning Add-in, which helps plan Individual parametrization Angio Assist Advanced Angio Advanced Patien ... Care Bolus Feet first - Position 20cm / 7in above feet FastView 00:35 + Whole Body FastView Vessel Scout yes vessel_scout 02:19 Generic Views localizer_aorta 00:31 Generic Views angio_f13d_cor_pre 00:39 1 Angio Advanced Planning Check pre images, prepare injector Care Bolus 01:21 Care Bolus angio_f13d_cor_post 00:39 1 TWIST feet yes Basic Decision TWIST feet yes angio_twist_cor_iso_feet 02:03 Generic Views 9 syngo MR XA60A – What’s New 2.2. Improved VIBE Phase Encoding Order Available for: MAGNETOM Vida, MAGNETOM Lumina Category: Standard feature Pre-requisites: None In rare cases, when applying the VIBE protocol without motion artifacts. When you have more motion in the fat saturation or without regional fat saturation, motion slice direction the Phase Encoding Order “Slices in Lines” artifacts might occur in the slice direction, resulting is beneficial, whereas the order “Lines in Slices” is better in cloud-like artifacts in the subtraction images. With when the dominant motion is in the phase encoding syngo MR XA60A, in addition to the “Automatic” Phase direction. Encoding Order, there is the flexibility to choose the Phase Encoding Order as “Lines in Slices” or “Slices in New benefits: Lines”, depending on the needs of the body region being imaged. The choice of the appropriate Phase Encoding Motion artifacts in the VIBE sequence can be reduced Order enables to reduce or change the appearance of by choosing the appropriate Phase Encoding Order for the body region being imaged. ¿ 1:07 min Auto @ None @ 2.3x2.3x2.0 mm3 1.00 Routine Contrast Resolution Geometry system Physio Inline Sequence Part 1 Part 2 Assistant Introduction RF Spoiling Incr. Gradient Spoiling Breast Application Phase Enc. Order Automatic Automatic Lines in Slices Slices in Lines The Phase Encoding Order can be chosen in Part 2 of the Sequence tab. A B Non-fat saturated VIBE breast subtraction image with A: “Lines in Slices” Phase Encoding Order, which results in cloud-like artifacts as indicated by the arrow, and B: the new “Slices in Lines” Phase Encoding Order, where the artifacts could be reduced. 10 Siemens Healthineers AG (listed in Frankfurt, The outcomes and statements provided by customers Germany: SHL) pioneers breakthroughs in healthcare. of Siemens Healthineers are unique to each customer’s For everyone. Everywhere. Sustainably. As a leading setting. Since there is no “typical” hospital and many medical technology company headquartered in Erlangen, variables exist (e.g., hospital size, case mix, and level of Germany, Siemens Healthineers and its regional service/technology adoption), there can be no guarantee companies are continuously developing their product that others will achieve the same results. and service portfolio, with AI-supported applications and digital offerings that play an increasingly important role On account of certain regional limitations of sales rights in the next generation of medical technology. These new and service availability, we cannot guarantee that all applications will enhance the company’s foundation in products included in this brochure are available through in-vitro diagnostics, image-guided therapy, in-vivo the Siemens Healthineers sales organization worldwide. diagnostics, and innovative cancer care. Availability and packaging may vary by country and is subject to change without prior notice. Some/All of the Siemens Healthineers also provides a range of services features and products described herein may not be and solutions to enhance healthcare providers’ ability to available in the United States. provide high-quality, efficient care. In fiscal 2022, which ended on September 30, 2022, Siemens Healthineers, The information in this document contains general which has approximately 69,500 employees worldwide, technical descriptions of specifications and options as generated revenue of around €21.7 billion and adjusted well as standard and optional features, which do not EBIT of almost €3.7 billion. always have to be present in individual cases. Further information is available at Siemens Healthineers reserves the right to modify the www.siemens-healthineers.com. design, packaging, specifications, and options described herein without prior notice. For the most current information, please contact your local sales representative from Siemens Healthineers. Note: Any technical data contained in this document may vary within defined tolerances. Original images always lose a certain amount of detail when reproduced. Siemens Healthineers Headquarters USA Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Healthcare 91052 Erlangen, Germany 40 Liberty Boulevard siemens-healthineers.com Malvern, PA 19355-9998, USA siemens-healthineers.us Published by Siemens Medical Solutions USA, Inc. · Order No. MR-23-NAM-5183 · QR700002278 · 11.2023 · ©Siemens Medical Solutions USA, Inc., 2023

  • deep resolve
  • haste
  • biomatrix
  • beat
  • sensor
  • open recon
  • physiologging
  • myexam
  • agio
  • vibe phase