syngo XR VA20 Select clinical protocol and adjust acquisition parameters simulation - USA
Quickly select a clinical protocol for a chest examination, add further exam information, and adjust the acquisition parameters in the syngo XR imaging software of the YSIO X.pree.
Continue Continue Continue Continue Continue Welcome and Introduction ? Select clinical protocol (4 min) Adjust acquisition parameters (4 min) syngo XR VA20 Select clinical protocol and adjust acquisition parameters Simulation You have entered patient data for a new patient or an already examined patient in the imaging software of YSIO X.pree. Now it is time to select a clinical protocol and add further exam information. You adjust the acquisition parameters in a second step. Or you have opened a patient from the worklist or registered an emergency patient. In that case, you can directly start adjusting the acquisition parameters. Use the arrows to navigate to a simulation of your choice. You can perform both simulations or choose a specific one. If you need help for navigating through the simulation, click this button. Welcome and Introduction ysio_xpree_va20_step3_Sel_cp_01.wav] You have entered patient data for a new patient or an already examined patient in the imaging software of YSIO X.pree. Now it is time to select a Clinical Protocol and add further exam information. You adjust the acquisition parameters in a second step. Or you have opened a patient from the worklist or registered an emergency patient. In that case, you can directly start adjusting the acquisition parameters. Use the arrows to navigate to a simulation of your choice. You can perform both simulations or choose a specific one. If you need help navigating through the simulation, click this button. Select clinical protocol You have entered the patient data for a new patient or you have modified the patient data of an already examined patient in the Patient Registration tab of the Scheduler. You will now learn how to proceed with the further tabs Clinical Protocols, Exam Information, and Institution in this simulation (4 min). Practice ? To start the simulation, select Practice. Select Clinical Protocol ysio_xpree_va20_step3_a_Sel_cp_01.wav] You have entered the patient data for a new patient, or you have modified the patient data of an already examined patient in the Patient Registration tab of the Scheduler. You will now learn how to proceed with the further tabs Clinical Protocols, Exam Information, and Institution in this simulation. To start the simulation, select Practice. Adjust acquisition parameters You have chosen a clinical protocol for your registered patient and selected the Exam button. Or you have opened a patient from the worklist by selecting the Exam button or registered an emergency patient. All off these steps lead you automatically to the Examination mode. You will now learn how to adjust the acquisition parameters in the Examination mode before you start the actual examination (4 min). Practice ? To start the simulation, select Practice. Adjust Acquisition Parameters ysio_xpree_va20_step3_b_AcqPar_01.wav] You have chosen a Clinical Protocol for your registered patient and selected the Exam button. Or you have opened a patient from the Worklist by selecting the Exam button or registered an emergency patient. All off these steps lead you automatically to the Examination mode. You will now learn how to adjust the acquisition parameters in the Examination mode before you start the actual examination. To start the simulation, select Practice. Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthineers AG 2023 Siemens Healthineers Headquarters\Siemens Healthineers AG\Siemensstr. 3\ 91301 Forchheim\Germany\Phone: +49 9191 18-0\siemens-healthineers.com ? Disclaimer Select Clinical Protocol Select the Clinical Protocols tab to continue. Select Clinical Protocol Tab ysio_xpree_va20_step3a_01.wav] You have entered all relevant demographic patient data of a new patient called Jane Doe. Now, you would like to assign a clinical protocol to this patient. Select the Clinical Protocols tab. Please select the Clinical Protocols tab to continue. Select Chest to continue. Select Body Region ysio_xpree_va20_step3a_02.wav] The screen is split into four areas: The left column with the patient data. The middle left column with body region names and an illustration of the body regions. The middle right column with Available Clinical Protocols. And the right column with the Assigned Clinical Protocols. Let’s say we’d like to perform a Chest standing p.a. exam for our patient. You can either select the body region name Chest on the left or select the chest in the illustration. Select the body region name Chest. Please select Chest to continue. Scroll down the Available Clinical Protocols list to continue. Scroll in Available Protocols List ysio_xpree_va20_step3a_03.wav] The selected body region is highlighted in the illustration. Available Clinical Protocols for this body region are listed. On a touch screen, you can scroll through this list by swiping up and down with your finger. We want to select Chest standing p.a.. Scroll down the Available Clinical Protocols list to see this exam. Please scroll down the Available Clinical Protocols list to continue. Select the + icon of Chest standing p.a. to continue. Select Clinical Protocol ysio_xpree_va20_step3a_04.wav] Select the plus icon next to Chest standing p.a. to assign this clinical protocol to this patient. Please select the + icon of Chest standing p.a. to continue. Select the tab Exam Information to continue. Select Exam Information Tab ysio_xpree_va20_step3a_05.wav] The chosen clinical protocol appears in the list of assigned Clinical Protocols. You can delete an assigned clinical protocol, by selecting the cross to the right of its entry. If you would like to perform a second exam, for example a sitting chest exam, you can add it to the list of assigned Clinical Protocols by selecting the plus icon next to it. You are now ready to continue with the next tab Exam Information. Please select the tab Exam Information to continue. Select the field Accession Number to continue. Select Accession Number ysio_xpree_va20_step3a_06.wav] The Exam Information tab opens. Here you can enter, modify, or delete required exam information. To delete an entry, select the corresponding field. Please select the field Accession Number to continue. Select the tab Institution to continue. Select the Institution Tab ysio_xpree_va20_step3a_07.wav] The selected field is highlighted. By selecting the cross in the selected field, you can delete its entry. If you scroll down, you see more available entry fields. In our example, we keep these fields as they are and continue with the last tab Institution. Please select the tab Institution to continue. Select Exam to continue. Modify Institution Information ysio_xpree_va20_step3a_08.wav] The Institution tab opens. Available fields are admitting diagnosis, current patient location, name and address of your institution, and performing or referring physician. If you scroll down, you can enter the Requesting Physician and Operator. By selecting the single fields, you can enter, modify, or delete required data about your institution. In our example, we keep these fields as they are. You are now all set to adjust acquisition parameters for your patient in the Examination mode. Select Exam to continue. Please select Exam to continue. Congratulations! You have successfully completed the simulation. Click Retry to try the simulation again. To view additional simulations, click Continue. Select Exit to read the Disclaimer and exit this simulation. Retry Continue Exit Imaging Software Set for Parameter Adjustement ysio_xpree_va20_step3a_18.wav] You have registered a patient, put in all relevant data, chosen a Clinical Protocol, and selected Exam. The Examination mode has opened and you are ready to adjust the acquisition parameters. You have successfully completed the simulation. Click Retry to try the simulation again. To view additional simulations, click Continue. Select Exit to read the Disclaimer and exit this simulation. Examination mode Adjust Acquisition Parameters in the Examination Mode ysio_xpree_va20_step3b_1.wav] You have selected Exam, and the Examination mode has opened. From this point on, it does not matter if you are working with an emergency patient or a registered patient. The workflow for both kinds of registration is exactly the same. In our case, we want to set the acquisition parameters for our registered patient Jane Doe. In this mode, your clinical workflow is displayed in the workflow area in the top left corner. The selected Clinical Protocol is displayed on top of the workflow area on the left. On top of the parameters and tools area on the right, you can see the selected Clinical Protocol Step. You can still change your selected Clinical Protocol Steps, or add further Clinical Protocols, by selecting the + icon next to Edit Clinical Protocol Steps. On the bottom left, the green checkmark indicates that the system is ready for exposure. The pre-set parameters are shown in the status bar below the Clinical Protocol on the right. You can change the parameters in the workflow area on the right. Select Patient Size to continue. Check or Correct Patient Size ysio_xpree_va20_step3b_2.wav] For an examination, you mainly check or correct the Patient Size and the Acquisition Type. You can also adjust the exposure parameters, such as kV, mAs, and others. We start by opening the Patient Size drop-down list. Please select Patient Size to continue. Select Patient Size M to continue. Select Patient Size ysio_xpree_va20_step3b_3.wav] The drop-down list appears. Let’s select Patient Size M. Please select Patient Size M to continue. Select the Acquisition Type field to continue. Check or Correct Acquisition Type ysio_xpree_va20_step3b_4.wav] You may have to change the Acquisition Type, which indicates the detector or workstation used for the acquisition. Select the Acquisition Type field to unfold its drop-down list. Please select the Acquisition Type field to continue. Select Wall Stand to continue. Select Acquisition Type ysio_xpree_va20_step3b_5.wav] The drop-down list appears. The available detectors depend on the detectors assigned to the system. In our example, the Table and Wall Stand mode are selectable. Two free exposure modes for acquisitions with two different mobile detectors can also be chosen. The icons symbolize the mode and the selected mobile detector, here the Max Wi-D and the Max mini detector. Please note: Depending on the Acquisition Type, the selectable exposure parameters vary. Select Wall Stand for our Chest standing p.a. workflow. Please select Wall Stand to continue. Select the – icon to continue. Increase Tube Voltage Value ysio_xpree_va20_step3b_6.wav] Using the plus or minus icon, you can increase or decrease the tube voltage value to your needs. If you select the value directly, you can also select the desired value from a scrollable list. For training purposes, let’s decrease this value using the minus icon. Please select the – icon to continue. Select Show More to continue. Select Show More ysio_xpree_va20_step3b_7.wav] You have decreased the tube voltage value to 121 kV. The Dose and Measuring Field values are also adjustable. Adjusting the measuring field to the region of interest improves the image quality. Depending on the selected clinical protocol step, you must select one or more suitable measuring fields so that the automatic exposure control can match the dose to the organ of interest. For our examination, we leave the Dose and Measuring fields as they are. We want to change more exposure parameters. Select Show More to see them. Please select Show More to continue. Scroll down the to continue. Change Exposure Mode ysio_xpree_va20_step3b_8.wav] You now have the option to select a different Exposure Mode for the acquisition. The available exposure modes depend on the system and the selected workplace. We will leave the Exposure Mode as it is. Scroll down to see more of the exposure parameters. Please scroll down to continue. Select the EC value to continue. Set Exposure Control Value ysio_xpree_va20_step3b_9.wav] The additional functions Exposure Correction (EC), mmCU, and Focus become visible. mmCu lets you add an additional copper filter into the beam to harden the radiation, for example, for pediatric examinations. For the focus, you have the option to select the small or the large focus. We want to change only the Exposure correction. If you want to adjust this value, the Dose Exposure Mode must be selected. The Exposure correction can be used to compensate the influence of metal implants. 1 exposure point changes the exposure about 25%. In general, 1 exposure point compensates an object thickness of approximately 1 cm. The Exposure Correction can be set between -2 and +2 and modified in increments of 0.5 exposure points (EP). We want to increase the dose by one exposure point. You can use the plus and minus icons, or select the desired value from a scrollable list. To open this list, select the value directly. Please select the EC value to continue. Select the value 1 to continue. Adjust values from value list ysio_xpree_va20_step3b_10.wav] A scrollable list of available values appears. On the real system, you can scroll through this list by swiping your finger up or down. To scroll through the list value by value, select the up and down arrows. Select the value 1 to confirm and close the list. Please select the value 1 to continue. Congratulations! You have successfully completed the simulation. Click Retry to try the simulation again. To view additional simulations, click Continue. Select Exit to read the Disclaimer and exit this simulation. Retry Continue Exit Imaging Software Set for Examination ysio_xpree_va20_step3b_11.wav] If you have changed exposure parameters, you can reset them to the settings of the clinical protocol step. To do that, tap the Reset Parameters button. From an imaging software perspective, you are now all set to perform the examination of your patient. Congratulations! You have successfully completed the simulation. Click Retry to try the simulation again. To view additional simulations, click Continue. Select Exit to read the Disclaimer and exit this simulation. Instructions Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Tmeline Select the buttons to learn more about a topic. Be sure to review all topics before navigating to the next slide. Click X in the top right corner to continue. Tab Arrow Slide Question Bank 1 syngo XR VA20 Select clinical protcol & adjust acquisition parameters 1.1 Welcome and introduction 1.2 Select clinical protocol 2.1 Select the Clinical Protocols tab 2.2 Select body region 2.3 Select from Available Clinical Protocols 2.4 Select clinical protocol 2.5 Select Exam Information tab 2.7 Select Institution tab 2.8 Modify institution information 2.9 Imaging software set for parameter adjustement 1.3 Adjust acquisition parameters 3.1 Adjust acquisition parameters in the Examination mode 3.2 Check or correct patient size 3.3 Select patient size 3.4 Check or correct acquisition type 3.5 Select acquisition type 3.6 Increase tube voltage value 3.8 Change exposure mode 3.9 Set exposure control value 3.11 Imaging software set for examination
- registration
- sim
- protocols
- xray