syngo XR VA20 Perform a chest examination simulation - USA
You will learn about the steps of a chest examination workflow in this simulation.
Continue Continue Continue Continue Continue Continue Welcome and Introduction You have entered the patient data for a patient. You will now get to know the steps of a chest examination workflow (5 min). Practice ? To start the simulation, select Practice. syngo XR VA20 Perform a chest examination Simulation Welcome ysio_xpree_va20_step5_01.wav] You have entered the patient data for a patient. You will now get to know the steps of a Chest examination workflow. To start the simulation, select Practice. Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthineers AG 2023 Siemens Healthineers Headquarters\Siemens Healthineers AG\Siemensstr. 3\ 91301 Forchheim\Germany\Phone: +49 9191 18-0\siemens-healthineers.com ? Exit Disclaimer Chest examination Select the Clinical Protocols tab to continue. Select clinical protocol tab ysio_xpree_va20_step5_02.wav] You have entered all relevant demographic patient data of a patient called Jane Doe. For our chest examination workflow, we will assign a suitable clinical protocol to this patient. Select the Clinical Protocols tab. Please select the Clinical Protocols tab to continue. Select the body region Chest to continue. Select body region ysio_xpree_va20_step5_03.wav] Let’s say we’d like to perform a Chest standing p.a. exam for our patient. You can either select the body region name Chest on the left, or select the chest in the illustration. Select the body region Chest in the illustration. Please select the body region Chest to continue. Scroll down the Available Clinical Protocols list to continue. Scroll in available protocols list ysio_xpree_va20_step5_04.wav] We want to select Chest standing p.a.. Scroll down the Available Clinical Protocols list to see this exam. Please scroll down the Available Clinical Protocols list to continue. Select the + icon of Chest standing p.a. to continue. Select clinical protocol ysio_xpree_va20_step5_05.wav] Select the plus icon next to Chest standing p.a. to assign this clinical protocol to this patient. Please select the + icon of Chest standing p.a. to continue. Select Exam to continue. Select exam ysio_xpree_va20_step3a_06.wav] The chosen clinical protocol appears in the list of assigned Clinical Protocols. You are now all set to switch to the Examination mode and start your examination. Select Exam to continue. Please select Exam to continue. Select the SmartMove button to continue. Press SmartMove button ysio_xpree_va20_step5_7.wav] The Examination mode opens. For our Chest examination workflow, the pre-selected Acquisition Type Wall Stand is correct and does not need to be changed. You are all set to start the examination. To prepare the tube, press the SmartMove button on the remote control. Please select the SmartMove button to continue. Position tube ysio_xpree_va20_step5_8.wav] Keep the button pressed until the X-ray tube assembly and the detector have moved to the start position for our selected examination. For our chest examination, the tube stops at a source image distance of 1.8 m to the wall stand. Position patient ysio_xpree_va20_step5_9.wav] Position the patient at the wall stand. Adjust collimation ysio_xpree_va20_step5_10.wav] The myExam 3D Camera shows you the patient on the workstation monitor. The Auto Thorax Collimation function is automatically active. Auto Thorax Collimation detects the thorax and suggests a collimation, including the top alignment, shown by the blue ROI. You can adapt the range of the auto collimation virtually or by manually moving the tube. To change it virtually, select the frame and pull it where you want it. To change the range manually, simply tilt the tube. If you want to change the collimation width, you can also pull the frame on the workstation monitor or use the knobs on the collimator. Press the acquisition button to continue. Exposure release ysio_xpree_va20_step5_11.wav] Once you have specified the collimation to your preferred settings, you are ready to release an exposure. You can press either of the acquisition buttons. In our simulation, we will use the acquisition button on the control box. Please select the acquisition button to continue. Please note: This image is a phantom image. Select the Distribution tab to continue. Post processing options ysio_xpree_va20_step5_12.wav] An exposure has been released. The acquired image appears immediately on your screen. We offer you various options to change the image. Some of them can be seen on the right, in the configurable Favorite Tools. For example the “adding or changing a laterality label” tool and the annotation tool. To learn more about these options, see further YSIO X.pree learning objects on PEPconnect. Right now, we want to directly export this image. Select the Distribution tab to see the export options. Please select the Distribution tab to continue. Select Export to continue. Distribution tools ysio_xpree_va20_step5_13.wav] The Distribution mode has opened. All acquired images for our patient Jane Doe are displayed. They can be selected or deselected for export by tapping the check boxes. On the right sight of the screen, the distribution tools have opened. If necessary, you can select a different target for the export. Select Export to export the images immediately. Please select Export to continue. Congratulations! You have successfully completed the simulation. Select Retry to try the simulation again. To return to the overview page, select Continue. Select Exit to read the Disclaimer and exit this simulation. Retry Continue Exit Congratulations ysio_xpree_va20_step5_14.wav] You have executed a Chest examination. Congratulations! You have successfully completed the simulation. Select Retry to try the simulation again. To return to the overview page, select Continue. Select Exit to read the Disclaimer and exit this simulation. Instructions Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click X in the top right corner to continue. Timeline Question Bank 1 syngo XR20 VA20 Chest examination workflow simulation
- xray
- lung