
syngo.via VB30-VB60 Delta Job Aid - USA
This delta job aid is for users who skipped software versions and provides information about features & functionalities that came up between VB30-VB60 in syngo.via.
SIEMENS Healthineers syngo.via VB30-VB60 News & Improvements Powerful Reading. Actionable Results. Template Effective Date: 27 May 2019 | HOOD05162003010284 Job Aid Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 Please note This learning material is only providing you with information about the highlights of the syngo.via versions VB40, VB50, and VB60. In order to get the complete information, please consider the corresponding delta training material shown in the ‘Upgrade (Delta Training)’ section of the syngo.via Training Area. 2 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 syngo.via VB30-VB60 News and Improvements SIEMENS Healthineers Table of Contents General Improvements 4 MM Reading: Interactive Spectral Imaging 10 Clinical Tools in MM Reading 15 Findings Assistant in MM Reading 26 Interfacing with Third-Party Vendors 28 3 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Ready for Routine General Improvements 4 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 Ready for Routine SIEMENS Healthineers General Improvements New design of user interface What`s new syngo News Siemens Healthineers now provides a new Automatic information window syngo News is our new information clear and easy digital interface throughout displaying information on what is new in channel specifically tailored to your unique all the new Siemens Healthineers products this version. needs. and service portfolios. SIEMENS Hecithineers New in this version ? x Healthintern> 12 x Patient Browser Results 234 max. 123829 29.11.2017 1. CT Lung Assistant 35.11.20171- 22.10.2013 1. syngo News 20.40.2017 1. In MM Reading 17 43.2017 1 39.11.2015 1- Similar Patient Search provides CT Lung Assistant In MM Reading Similar Pacont Search provides any time access to any time access to . similiar reference cases Similar references cases . differential diagnosis tractbock information from Differential diagnosis Thieme eftef for imerstitial -- lung dise mes . Textbook information from Help Thieme eRef Remote Assistance for interstitial lung diseases What's New available with optional liserac syngo News O O O About CO syngo News Similiar Patient Search Provides Al based Close diagnostic support 5 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 Link to Online Training SIEMENS Healthineers • In this new version of syngo.via your SIEMENS Healthineers PEPconnect Explore Search Content and Groups learning experience has been improved. You English Log In / Register Medical Imaging and Therapy now have a direct link to our free online Advanced Visualization and Imaging IT (syngo) Angiography Computed Tomography Digital Marketplace Magnetic Resonance Imaging Mammography Mobile C-arms nexaris Therapy Suites Nuclear Medicine Technology - PET Nuclear Medicine Technology - SPECT Radiation Therapy education platform, called PEPconnect. Robotic-assisted Interventions Ultrasound X-ray Products Advanced Visualization and Imaging IT (syngo) syngo Dynamics - CVIS syngo Virtual Cockpit syngo.plaza - PACS The link is available in the access bar of EN EN EN • syngo.share syngo.via your syngo.via client. EN EN syngo.via Clinical Applications EN V syngo.via VB20 syngo.via View&GO Syngo WebViewer K EN EN • The link provided directs you to the specific TOP syngo.via training area, relevant for your SIEMENS. Healthineers PEPconnect system and version. Explore Search Content and Group English Log In / Register syngo.via Type Of: All Language: English Filter by Module/Version: None Selected Filter By Title: Enter text If you do not have an account with Events Upgrade (Delta Training) General Functions & Features Routine Reading & Reporting Computed Tomography Applications Magnetic Resonance Imaging Applications Mammography Applications Nuclear Medicine Applications • Radiation Oncology Applications Technical Administration PEPconnect, simply register as prompted ! Events with an email address and password. Help Ask-the-Experts - virtual Live Online Training Please note: This feature requires internet Remote Assistance 0 0 9 38 Details connection on the syngo.via client. What's New Upgrade (Delta Training) syngo News About 6 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 General Improvements SIEMENS Healthineers Printing • A new badge icon was implemented in order to indicate that images were sent to printing. Printing × Print Printer Adobe PDF Copies • As soon as you print or delete the images, the T Print Save Paper Size Letter Number of Print-o ... 0 Image badge icon disappears. Zoom Pan Rearrange Text Keep Images Every N -. Invert Background Printer Microsoft XPS Doc The Invert Background feature inverts the Paper Size • Letter background of the printed segment on the Copies film print sheet. It does not invert the image Print Save Image itself. Number of Print-outs: 0 Invert Background • When many print sheets are available, the 3/9 images on last page Number of images on last page is now displayed. DPrinting • the Number of images on last page is now displayed. syngo.via software version VB40/50/60 is not commercially available in all countries. 7 Due to regulatory reasons its future availability cannot be guaranteed. Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 syngo.via VB30-VB50 News and Improvements SIEMENS Healthineers General Improvements – syngo.via OpenApps1 Digital Marketplace • Siemens Healthineers introduces the Digital Marketplace as the new web X store providing medical post-processing apps created by us or our partners. • Our Digital Marketplace provides both cloud based applications, as well as locally installed applications. OpenApps • Locally installed applications, known as syngo.via Open Apps, are Catalog Order status downloaded from the digital marketplace and installed on your syngo.via Welcome to the server. Digital Marketplace Explore apps for cutting-edge care from Siemens Healthineers and solution partners • The Installed Apps section provides further details on the installation date Installed Apps and license state. Application family syngo.via Manufacturer Installation type All manufacturers All types • Each third party vendor application is downloaded with a demo dataset. Q Search for app name, keyword ... Sort by Date desc • Start the apps directly from this section for demonstration and training. • The downloaded syngo.via OpenApps are seamlessly integrated in MM CT Skull Unfolding for syngo.via CT Coronary Plaque Analysis for CT Cardiac Risk Assessment for CT Cardiac Functional Analysis for Reading, easily accessible via the corresponding icon in the tool gallery. VB50 syngo.via VB50 syngo.via VB50 syngo.via VB50 Research CT Trauma Head Research Cardiac CT Cardiovascular Research CT Cardiac CT Research Cardiac CT Cardiology Digital Marketplace Coronary Artery Disease (CAD) Frontier Cardiology Obesity Frontier Cardiovascular • You can now also download the syngo.via Frontier research applications calculate unfolded views of the skull calculate unfolded views of the skull Research prototype for the Research prototype designed to Research prototype designed to quantification and qualification of quantify abdominal and pericardial analyze functional parameters of the coronary and carotid plaques fat for cardiac risk assessment ... heart and its compartments directly from the Digital Marketplace in your syngo.via client. • The installed research applications are seamlessly integrated with syngo.via as a new workflow. 1 – Siemens Healthineers is neither the provider nor reseller nor legal manufacturer of any partner applications. Any claims made for 8 these products are under the sole responsibility of the legal manufacturer. Additionally, the partner applications mentioned here may Effective Date: 17 May 2022 | HOOD05162003262024 not be commercially available in all countries. Please contact the legal manufacturer for more information. Unrestricted © Siemens Healthineers, 2022 syngo.via OpenApps1 SIEMENS Healthineers General Improvements • Powered by the OpenApps Connector, you can now x install the desired application without internet connection in the syngo.via client, using any other windows computer in the same network with internet 5 OpenApps + X × connection. 1 Not secure | syngovia/OpenApps/ ... • PACS Ready technology enables the auto-processing Start OpenApps Connector Use this button to start the OpenApps Connector tool which connects your system for OpenApps Applications. It can be run with the Siemens Healthineers Digital Marketplace. independently from any workflow configuration when new studies of the current day are incoming from the modality. - Welcome • A badge icon notification will be displayed in the to the Store Digital Marketplace shopping card icon when, for example, there are completely new apps --- --- --- available/published in the marketplace or your --- -- commercial/purchased license will expire soon. OpenApps.Connec .... exe Show all X 1 – Siemens Healthineers is neither the provider nor reseller nor legal manufacturer of any partner applications. Any claims made for these products are under 9 the sole responsibility of the legal manufacturer. Additionally, the partner applications mentioned here may not be commercially available in all countries. Effective Date: 17 May 2022 | HOOD05162003262024 Please contact the legal manufacturer for more information. Unrestricted © Siemens Healthineers, 2022 syngo.via software version VB40/50/60 is not commercially available in all countries. Due to regulatory reasons its future availability cannot be guaranteed. SIEMENS Healthineers Ready for Routine Interactive Spectral Imaging in MM Reading 10 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 Interactive Spectral Imaging in MM Reading SIEMENS Healthineers A new Image Format for DE – SPP1 (Spectral Post-Processing) Spectral Post-Processing (SPP Dataformat) • The Interactive Spectral Imaging features uses a single post processing series in the file format Spectral Post-Processing (SPP) that contains all the necessary information. Thus separate high and low kV datasets are no longer needed. • Improve your clinical workflow by bundling the spectral low and high kV series into one Spectral Post-Processing (SPP) data series. • Interactive Spectral Imaging gives you the possibility to interactively change different Conventional CT monoenergetic energy levels and evaluate certain dual energy representations such as Virtual Non-Contrast (VNC) or Iodine in MM Reading. • The SPP series shows a conventional CT Image or a generated Monoenergetic Plus Image, readable in your PACS system. VNC 1 – Functionality is provided by syngo.CT Dual Energy and syngo.CT Extended Functionality 11 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 Dual Energy goes Routine with syngo.via VB40 SIEMENS Healthineers Interactive Spectral Imaging – as Easy as Windowing Interactive Spectral Imaging (ISI) is a new and simplified way of visualizing Dual Energy data. SIEMENS Healthineers Server. MS-CT.APPVIA03. wurmlech siemens.de adminUser Viewing CT general • Instead of calculating multiple series like VNC or Mono+, Viewing Stack 3x2 MPR VRT Stack 2/2 syngo.via now creates a single series called Spectral Post- Mono+ VNC Favorite Tools Processing (SPP) data that contains all the necessary post processing information. Series • Only these Spectral Post-Processing (SPP) data needs to be loaded to MM Reading in order to have access to the new Favorite Tools X Findings Reset Rotate Layout Synch features and functionalities. Iodine Mixed Assisted Distance ROI Cercle Perpend ... Line Snapshot Export Image Printing • On patient follow up, high and low kV data is no longer needed. 12 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 MM Reading SIEMENS Healthineers Interactive Spectral Imaging • Switch the most common Dual Energy application classes by one button click using the interactive image text: SIEMENS ... Healthineers Server MS.CT.APPVIA03, numloon siemers.de adminUser Mono+ Viewing Q o x • CT general Viewing Stack 3x2 MPR VRT Sta Virtual Non Contrast (VNC)1 • Mono+ VNC Favorite Tools • Mixed Iodine* • Series Fused VNC/ Iodine1 • Favorite Tools Findings Reset Rotate Layout Sych Iodine Mixed Assisted Distance ROI Circle Perpend Line • Easily change the keV level of your Monoenergetic Plus image by: Snapshot Export Image Printing • Mouse movement (left / right or up / down) Full Text Hide Lines > x Define Bone • Entering a value using the keyboard Vestels Remo • Using the slider in the Dual Energy Mono Plus properties box + Mono+ Dual Energy Mono+ Properties ? x kev|70 104 70keV OK Cancel 1 – VNC and Iodine representations are not available for Dual Spiral Dual Energy and TwinSpiral Dual Energy 13 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 MM Reading SIEMENS Healthineers Interactive Spectral Imaging • ROI or VOI measurements can be performed on any representation. • When performing a measurement with the ROI Circle tool, the measurement details text displays the mean Hounsfield Units (HU) for MIX, VNC, Iodine. [1] ROI Circle CT_2 lodine Min / Max: -36 HU/22 HU Mean/SD: -7 HU/10 HU Area: 2,37 cm2 • The Findings Assistant reflects as well on which representation MIX/VNC/IODINE Mean: 24 HU/32 HU/-7 HU the measurement has been performed. • Spectral Post-Processing (SPP) data can also be used with CT [1] ROI Circle CT_2 DE TB Chest. 50 % DE TB_Chest. Extended Functionality in MM Reading such as: lodine Min / Max: -36 HU/22 HU Mean/SD: -7 HU/10 HU • Define vessel Area: 2,37 cm2 • Table- and Bone Removal MIX/VNCAODINE Heart Isolation Mean: 24 HU/32 HU/-7 HU • • Coronary Tree View • CPR Ranges 14 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Ready for Routine Clinical Tools in MM Reading 15 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 MM Reading: Clinical Tools SIEMENS Healthineers MR General tools • MR General Tools previously only available in MR ... workflows are now also available in MM Reading CURRENT in the toolbox or lower right corner menu • Access the following Analysis tools: • Subtraction • Addition • Division ADC / calculated b- • Multiplication Substraction Composer • Arithmetic Mean and values • Calculated ADC and B-values Simplify routine All necessary MRI Accessible with one reading Generic tools click As well as to the Correction tools such as: • Motion Correction • Distortion correction and • Image Filter functions • Composing and combining is integrated as well 16 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 MM Reading: Clinical Tools – CT Lung Change Tool SIEMENS Healthineers In MM Reading, the CT Lung Change tool displays changes in density across ....... different time points. The CT Lung Change tool can be CT Lung invoked from the tool gallery. Change ....... • Current and prior series are automatically registered. CT Lung Change ? X • If the automatically selected series from the prior time point is not Compare following Series adequate, you can select another suitable series from the drop-down 10/6/2014 -Lung 1.0 17Of 3 LCAD [3] 8/19/2014 -Lung 1.0 17of 3 LCAD [3] menu. 8/19/2014 -Lung 1.0 17Of 3 LCAD [3] 6/10/2014 -Lung 1.0 17Of 3 LCAD [3] Evaluate MI Restrict to Lung • Changes in HU values are displayed as a colour overlay on MPR/ MPR Show Change Thick: Density® • Decreased HU values are indicated by blue colour. CT Lung Change ? X Decreased • Increased HU values are indicated by orange colour. Compare following Series 10/6/2014 -Lung 1.0 170f 3 LCAD [3] The evaluate change functionality activates a lens, displaying original X • Lung Change for 6/10/2014 -Lung 1.0 170f 3 ... series without colour overlay. The toggle functionality allows to change the time point visualized in the lens to evaluate a dedicated region. Show Evaluate M Restrict to Lung Hide Change • A progress bar is displayed to provide feedback on how long the comparison will take. 17 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 MM Reading: Clinical Tools – LungCAD1 SIEMENS Healthineers The syngo.CT Lung CAD (LCAD) is a Computer-Aided Detection (CAD) tool Current Prior 1 designed to assist radiologists in the detection of solid and subsolid pulmonary nodules. The algorithm is powered by a highly sophisticated deep learning algorithm and can now be used as a concurrent first reader. • A mini toolbar has been introduced to navigate through the LungCAD marks. C1 Ci, Change Since: 1/16/2019 Diameter: 0.78 mm iameter. 11.26 mm (+17%) Max Orth. Diam: 8.77 mm M. Orth. Diam: 10.32 mm (+1826) Mean Diameter: 9.25 mm Mex Diameter: 10.84 mm (+1798) Volume: 0.39 ml Volun e: 0.58 ml (+4988) Average HU: -9.22 HUI Averag HU: 14.19 HU (+254%) VDT.596 Days • The LCAD navigation tool available in MM Reading, automatically computes the lesion segmentation. • The LCAD tool also automatically matches and segments the corresponding C1, Change Since: 19.08.2014 lesion in the prior 1 case and displays parameters such as the % of change Diameter: 11,36 mm (+17%) and volume doubling time. Max. Orth. Diam: 10,32 mm (+18%) Mean Diameter: 10,84 mm (+17%) Volume: 0,58 ml (+49%) Average HU: 14,19 HU (+254%) The lens view provides a zoomed view of the CAD marks VDT: 82 Days • • It allows to scroll and zoom • Different windowing levels can be applied to enhance distinction between nodule components. The LungCAD tool can be invoked from the tool gallery. LungCAD 1 – LungCAD requires an additional license and might not be available in all countries, ... ......... 18 functionality might vary in different countries. Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 MM Reading: Clinical Tools SIEMENS Healthineers Lesion Quantification Tool • In addition to the automatic lesion quantification available [1] Nodule Measur. in the LungCAD tool, a new semi-automatic 3D L1, Change Since: 1/16/2019 Diameter: 11.36 mm (+17%) segmentation tool for the quantification of lung nodules in Max. Orth. Diam: 10.32 mm (+18%) Mean Diameter: 10.84 mm (+17%) CT datasets has been implemented in MM Reading. Volume: 0.58 ml (+49%) Average HU: 14.19 HU (+254%) VDT: 596 Days • The Lesion Quantification tool is located in the tool gallery. Favorite Tools • This tool uses the same algorithm as in MM Oncology CT O 1 E E Lung Segmentation tools. Scroll Reset OpenApps Parallel S/ine Spine/Rib LungCAD Lesion CT Lung Distance Angle on ROI Circle Hide Lines Full Text Trauma Layout Ranges langes Label Quantific. Assistant Line Stack • It can be used to measure solid and sub-solid lung nodules. A [] Nodule Measurooo L1, Change Since: 1/16/2019 • This tool supports a follow-up examination, displaying the Diameter: 11.36 mm (+17%) L1 [2] Nodule Measur ... Max. Orth. Diam: 10.32 mm (+18%) Diameter: 9.73 mm Mean Diameter: 10.84 mm (+17%) Max. Orth. Diam: 8.77 mr Volume: 0.58 ml (+49%) Mean Diameter: 9.25 mm Average HU: 14.19 HU (+254%) Volume: 0.39 ml percentage of change in the measurement details box. VDT. 596 Days Average HU: -9.22 HU R 19 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 MM Reading: Clinical Tools SIEMENS Healthineers CT Lung Assistant (Similar Patient Search1) • The CT Lung Assistant tool which calls-up the SPS CT Lung Assistant - NSIP (1/1/1900) Web Service is available in the MM Reading Favorite Tools SIEMENS × Healthineers Similar Patient Search Web Service workflow. Tags : |F acute chronic = bilateral focal smoking very rare Scrol Rotate Synch Open Apps Hide Idiopathic Pulmonary Fibrosis: Exacerbated Usual Interstitial Pneumonia (UIP) Graphics acute bilateral • The Similar Patient Search (SPS) Web Service is an · Reticular patte interactive tool that provides supplementary ? . Traction brond . No dominant f Quick Distance ROI Auto Full Text Auto information to a radiologist reading chest CT images. . Predominantly Guide Line Contour Views . Mostly symme ..... • It presents visually similar reference cases with Pulmonary Lupus Erythematosus (SLE) acute chronic bilateral very rare Spine CT Lung Lesion LungCAD CT Lung Ranges Change Quantific ... Assistant known diagnosis from a cloud database and in Pneumonia is Pleural involve addition, relevant textbook content from Thieme, 35% of cases. Lupus pneumo a renowned scientific publisher. injury or diffuse pulmonary haemorrnage. O Non-Specific Interstitial Pneumonia (NSIP) chronic bilateral • You need to have an internet connection on the Fine homogeneous reticulations (chronic fibrosing type) and/or frosted-glass opacities (cellular acute type). syngo.via client to be able to use this feature. Traction bronchiectasis and volume reduction. · No dominant honeycomb patterns. Predominantly basal. Peribronchiovascular predominance often with relative sparing of the subpleural space. • You can request a trial version of this product in the Digital Marketplace. Rheumatoid Interstitial Lung Disease chronic bilateral 1 – SPS is not available in all the countries due to regulatory reasons. Future availability cannot be guaranteed. 20 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 MM Reading: Clinical Tools SIEMENS Healthineers CT Pulmonary Density • The CT Pulmonary Density automatically segments Favorite Tools K both lungs and the lung lobes and identifies the Distance ROI Circle Parallel Hide Lines Define Region Pulmonary LungCAD Spine Scroll MIR Thin Rotate Save as Print Export Snapshot Punch Custom Reset Line Range: Vessels Growing Density Ranges Series Image Image Text Windowl areas of opacities, displaying the quantifications in a HPL result table and a 3D VRT image. RPH • High opacity areas and an opacity score are also A included in the results table. Lung Pictogram • The CT Pulmonary Density tool can assist you in the Not for diagnostic use " diagnosis of pulmonary diseases. Certain parts of Pulmonary Density Lung Pictogram Colors Lung Opacity Total Opacity Score Opacity: 11.17% Opacity within a given region the Pulmonary Density tool were used in the 1% Score Lungs UR MR LR LL LL 25% Score " 50% Score " 2 prototype Siemens Healthineers offered to fight Opacity Score 75% Score = 3 Total Volume [ml] 5447.4 2734.4 2713 915.8 766.3 1052.3 1406.9 1226.1 >= 75% Score = Opacity Volume [mi) 608.3 510.2 98.1 87 37.1 366.1 16.1 Opacity Percentage [%] 11.2 Colors are not an indication or recommendation for treatment. 18,7 36 9.5 48 6.7 To interpret the results, please refer to the user documentation. COVID-19, to analyze ground-glass opacities and High Opacity Volume [ml) 133.8 120.8 13 57 08 114.4 0.1 12.9 The total opacity score of both lungs can range between 0 - 20. High Opacity Percentage (%) 2.5 4.4 0.5 0.6 0.1 10.9 Abbreviations Mean HU Total [HU] -758.3 -724,7 -792 3 -780.6 .827.3 -601.3 -830.9 .745.4 (L) Left Lung consolidations. It has been shown, that high opacity Mean HU of Opacity [HU] -432.2 .500 8 -564.2 .635.9 382.9 625.1 476.3 (R) Right Lung (UR) Upper Right Lobe Standard Deviation Total [HU] 232.4 264,1 189 2 199.6 188 308.6 161.1 209.2 (MR) Middle Right Lobe (LR) Lower Right Lobe Standard Deviation of Opacity [HU] 266. 228 9 202.1 167.3 267.5 136.8 235.3 (UL) Upper Left Lobe (LL) Lower Left Lobe abnormalities correlate with pneumonia, for example in COVID-19 patients. syngo.via software version VB40/50/60 is not commercially available in all countries. 21 Due to regulatory reasons its future availability cannot be guaranteed. Effective Date: 17 May 2022 | HOOD05162003262024 This tool is provided by syngo.CT Extended Functionality Medical Device. Unrestricted © Siemens Healthineers, 2022 MM Reading: Clinical Tools SIEMENS Healthineers Spine ranges • Spine ranges allows you to define slices perpendicular to AFL the spinal cord. 1,2 C2 • If this is incorrect, you can now correct the center line O o C3 RF A C4 using the green circles that are displayed in the center of O C5 C6 C the vertebras. C7 T2 T1 C6/C7 • In this new version of syngo.via, this functionality has o AFL Parallel (O) Radial Curved Spine * vascular been extended to include spine datasets from the MR Preview modality. Image Thickness 2,0 mm Distance between Images 2,0 mm Number of Images 110 • You can run the spine ranges on any spine sequence from Field of View 158,6 = x 158,6 - mm RF- Presets Image Series a Siemens MR, however the algorithm requires a T1 Curved Curved acquisition of the cervical, thoracic or lumbar spine to be ParaCor ParaSag present within the dataset. Start Accept Close Please note: For a complete list of the image requirements, please refer to the user manual. H. 22 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 MM Reading: Clinical Tools SIEMENS Healthineers ROI Auto Contour A ROI Properties Distance Line ? X The ROI Auto Contour enables you to measure a lesion ROI Auto Contour • with the assistance of auto contouring and can be used Display the following evaluations: Pixel Lens Min/Max Arrow with any modality that supports a ROI measurement. VMean/SD Marker Area (cm2) Angle Sum • It is available in the top right corner menu at same Number of Pixels T R Text position as the ROI Polygonal was in the tool gallery or Enhancements: Spine/Rib Label Automatic Contour in Polygonal ROI alternatively can be added in the context menu or Favorite Tools window. OK Cance • Using the RMB, open the ROI properties and make sure the checkbox Automatic Contour in Polygonal ROI is Favorite Tools × selected. ? Scroll Rotate Synch 3D Ref. Open Apps Quick Point Guide • This functionality is available for 2D, MPR, MPR Thick, MIP Thin, MinIP Thin, and MPR/MPR images. Distance ROI Auto Parallel Snapshot Print Export Line Contour Ranges Image Image E 1 Full Text Hide Lines Spine/Rib Reset Assisted Auto Label Layout Perpendi ... Views Lesion LungCAD CT Lung LT Lung Define Quantific .. Assistant Change Vessels syngo.via software version VB40/50/60 is not commercially available in all countries. 23 23 Due to regulatory reasons its future availability cannot be guaranteed. Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 MM Reading: Clinical Tools SIEMENS Healthineers Angle on Stack • This is a new tool available in MM Reading and it supports you in performing orthopedic measurements. Distance Line ROI Auto Contour • You can find the tool in the upper right corner menu or in the tools gallery. Pixel Lens Arrow • This tool measures an angle between two lines across different image planes. Marker si- • This multimodality tool is available for 2D, MPR, MPR Thick, MIP Thin, MinIP Thin and MPR/MPR image types. Angle A Angle on Stack • No automatic finding is created when using this tool. Text • This feature does not require the purchase of an additional license. Spine/Rib Label *** 24 Effective Date: 17 May 2022 | HOOD05162003262024 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 Unrestricted © Siemens Healthineers, 2022 MM Reading: Clinical Tools SIEMENS Healthineers CT Trauma Layouts • A new plugin is available in MM Reading, called CT Trauma. Viewing Trauma Brain Skull Unf. Stac 2x2 Hemorrha. Hemato ... Skull Unf. Fractures Head Soft Head Soft Neck Soft Neck Soft This plugin provides a collection of layouts to facilitate the +Sharp +Sharp • Thorax Abdomen Pelvis Soft Soft+SharpSoft+Sharp +Sharp reading of polytrauma CT scans and is protected by a license. Favorite Tools Scroll Reset OpenApps Parallel • The layouts are preconfigured to display soft and hard kernels Layout Ranges pine Spine/Rib LungCAD Lesion Ringes Label side-by-side for the different body parts, thus allowing you to Quantific ... O CT ung Distance ROI Circle Assistant Line Stack do a faster structured reading of your polytrauma cases. Hide Likes Full Text Trauma Tools Viewing • In addition, the scanners with software versions SOMARIS/10 CT Trauma VA40 or above can generate inline results providing a skull unfolding for hematoma and fractures1 that can also be Trauma Brain Skull Unf. Skull Unf. Stack2x2 Hemorrh Hemato ... Fractures visualized with the CT Trauma plugin. Head Soft Head Soft Neck Soft Neck Soft +Sharp +Sharp • To obtain a correct image loading in the CT Trauma layouts, Thorax Abdomen Pelvis Soft you need to assign the corresponding data role in the Auto Soft+Sharp Soft+Sharp +Sharp Tasking tab in the scanner2 (software version SOMARIS/10 VA40 or higher). V 1 – The availability of this feature is not guaranteed for all SOMARIS/10 VA40 scanners. 25 2 – The data role assignment in the scanner requires an additional license to be installed on the scanner. Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Actionable Results Findings Assistant in MM Reading 26 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 MM Reading: Findings Assistant SIEMENS Healthineers Body Regions and Reporting Guidelines The Findings Assistant supports the creation and management of structured Findings X findings. It is available in MM Reading and all MR workflows, except MR Cardiac. Lung Details LungRADS Screening 2 Current LungRADS Screening 2 max nodule length 0,99 cm Type LungRADS Screening orth. nodule length 0,78 cm lower lobe of left lung, low Cluster findings now according to body regions or organs and add general Max Solid Compo ... Dista Location • Orth. Solid Comp. Dista Organ Segment 10 Posterior basal, 10 Pos information. Series/ImaNo Clinical Finding Nodule Solidness Descrip ... solid Endobronchial les ... no Fatty • New reporting guidelines enhance documentation and communication of no spiculated no results: In addition to PI-RADS and BI-RADS, further international guidelines for: Basic Cad-Stenosis calcification no Cad-Stenosis Finding Group Margin Smooth • Lung-RADS Screening LI-RADS growth E baseline Lung Cancer Primary Tumor Additional pathology no • Lung Cancer TNM Staging Lung cancer Group Mean Total (mm) 9,00 ¢ LI-RADS Lung cancer distant metastasis Mean Solid (mm) 0,00 • Lung cancer lymph nodes Lung-RADS as. Lung-RADS 4A Lung cancer pulmonary nodules • CAD-RADS LungRADS Screening Disclaimer ACR Lung-RADS™ Versic are now available. MR Breast MR Prostate Overall Rating Neuro3D Comment Neurology Pulmonary nodule • Measurements and other attributes can now directly be exported from PDF Previous Finding Next Finding Findings Assistant1. 1 – Export includes patient demographics, body part and finding information. Export to 27 email is only available if Microsoft Outlook account is configured on the syngo.via client. Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Actionable Results Interfacing with Third-Party Vendors 28 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022 Reporting – Interfacing with Third-Party Vendors SIEMENS Healthineers A new “real-time” interface for exchanging data with external reporting PowerScribe One Help Demo 1 Siemens V File Report View Format Review applications is now available: Sign Draft Prelim Close Wet Read Discard PACS mPower PointerShare (Draft) 5555 - Frank N. Study, - CT Head and CTA Head/Neck SMART ASSIST PRIOR REPORTS (6) TEMPLATES MACROS PROCEDURE DATA > FIELDS INDICATION: Suspect Stroke COMPARISONS: None. Current Template You can send clinical data and findings to PowerScribe One (by AMBIENT MODE SNA 2020 (Default) • TECHNIQUE/PROTOCOL: Noncontrast head CT followed by contrast enhanced head and neck CT arteriogram ALERTS ( 2 ) was performed. Create New Template Nuance) and SmartReports (by Smart Reporting) BRAIN FINDINGS: Enter the template name to search Q Acute intracranial hemorrhage: absent Brain Parenchyma: No acute hemorrhage, mass effect or midline shift. Search Filters Ventricles and Sulci: Normal for age. Extra-Axial Spaces: No extra-axial fluid collection. Owner Anatomy Basal Cisterns: Normal. Section Folder Other: Normal paranasal sinuses, orbits, and cranium. Q Apply Finers Clear All Filters X For example, if you measure a lung nodule the measurement value ASPECT score (left hemisphere): 7 • ASPECT score (right hemisphere): 10 EMPLATES (1) Relevant TEMPLATE NAME and location of the nodule is automatically transferred to the report Report for MULTI_5_STP (1/1/1900) ? Dx application from PowerScribe One or SmartReports1 . CT | Thorax Biu E E PROCEDURE (5 > CLINICAL INFORMATION In the Digital Marketplace, you can request the creation of COMPARISON Findings • Lung parenchyma: no pulmonary nodules. FINDINGS customized Finding Types from our partner Smart Reporting V Lung parenchyma Pulmonary nodules No pulmonary ... . No pulmonary nodules No selection nfiltrates No pulmonary nodules Pulmonary cavities Granuloma Pulmonary emphysema Lung nodule • After importing, the new finding type is available in your syngo.via Fibrosis Diffuse metastatic lung disease Pulmonary nodule Findings Assistant, for example in the workflow MM Reading or in Heart Thoracic vessels any MR workflow Pulmonary venous congestion Pleura Lymph nodes Bones IMPRESSION • This provides you additional flexibility to create structured reports. 11:05:21 Report updated. Report Language: English Siemens Healthineers is neither the provider nor reseller nor legal manufacturer of any partner applications. Any claims made for 29 these products are under the sole responsibility of the legal manufacturer. Additionally, the partner applications mentioned here Effective Date: 17 May 2022 | HOOD05162003262024 may not be commercially available in all countries. Please contact the legal manufacturer for more information. Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 30 Effective Date: 17 May 2022 | HOOD05162003262024 Unrestricted © Siemens Healthineers, 2022
- syngo.via
- SY
- delta job aid
- vb30-vb60
- VB30-VB60
- syngo