
syngo Dynamics - What's New in VA43A
These training slides will introduce you to the feature enhancements when updating your syngo Dynamics system to VA43A.
Target group: Clinical Users, Clinical Admins, IT Admins
SIEMENS Healthineers syngo Dynamics What’s New in VA43A Template Effective Date: 26 Mar 2025 | QR700020784 1 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 syngo Dynamics: What’s New in VA43A SIEMENS Healthineers Table of contents VA43A feature enhancements: Ellipse Tool Enhancement 5 ICH S =- Continuous HL7 patient update 13 . - Workplace Client Multi-Session Virtual Deployment 17 Seqouia Mapping tab in SysAdmin 23 Support and compatibility update 25 Template Effective Date: 26 Mar 2025 | QR700020784 2 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Introduction SIEMENS Healthineers These training slides will introduce you to the feature enhancements when updating your syngo Dynamics system to VA43A. Please note: These slides are optimized for clinical and administration users and some features may not be described. Please refer to your user documentation or your Siemens Healthineers Service Representative for further information. Template Effective Date: 26 Mar 2025 | QR700020784 3 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Find the right training for your software version SIEMENS Healthineers 3 To learn about the changes to your system, it is important to About 1 x syngo Dynamics version VA43A know which software version was previously installed on your ? DN ULTRASOUND / SDXAPPS Siemens Healthineers AG. 2025. All rights reserved. This App system, and your current (new) software version. proprietary to Siemens Healthineers and contain works by Siemens He claimed. User Manual This Application may only be used in strict accordance with the terms The Application may contain embedded Third Party Software includin Measurement and Calculation Manual You can check your current software version directly on your right to use OSS delivered with the Applications is governed by the te such license are included as part of the Documentation and located media binder. The OSS is licensed to Customer royalty free; ho Release Notes syngo Dynamics Workplace. reimbursement of costs in connection with complying with the OSS terms of an OSS license and the Agreement, the relevant terms of ly Status component to which they relate. If delivery of source code is required 2 2 About copy of the source code for such OSS by accessing the OSS labeled meLAD time of Application purchase. Siemens Healthineers may from tim Siemens Healthineers will in each case include the relevant license teEAD PEPconnect Click on the Help menu (?) in the top right of the user Updates, Releases or Versions. • (01) 4056869984735 GTIN interface. (1) (240) 11707704 MODEL (422) 840 ORIGIN US (8012) VA43A SW-VERSION • Select About. (2) Manufacturer: Siemens Healthineers Headquarters: Product Identifier: Siemens Healthcare GmbH Siemens Healthineers AG Product Name syngo Dynamics • Your current syngo Dynamics Software version is Henkestr. 127 Siemensstr. 3 Product Version VA43A 91052 Erlangen 91301 Forchheim Germany Germany displayed in the About section. (3) Phone: +49 9191 18-0 Build Number 40.0.0.9588 ciomanc_haalthingarc rom Microsoft SQL Server 2016 (c) Microsoft Corporation. All rights reserved. Microsoft SQL Server 2019 (c) Microsoft Corporation. All rights reserved. Microsoft SQL Server 2022 (c) Microsoft Corporation. All rights reserved. Please check with your System Administrator or Siemens lonosoft Inc ., Visual Cath Report is covered by U.S. Patent No. 7,949,542 Electronic Instructions for Use ionosoft 2025-08 Healthineers Service Representative to find out which software MD version was previously installed on your system. Template Effective Date: 26 Mar 2025 | QR700020784 4 Please note: Certain features require a license and may not be available on your system. Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Ellipse Tool Enhancement Template Effective Date: 26 Mar 2025 | QR700020784 5 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Ellipse Tool Enhancement (I) SIEMENS Healthineers In syngo Dynamics, the Ellipse Tool has long been valuable SIEMENS Healthineers. syngo Dynamics Echo Measurements, Patient for assessing cross-sectional areas of anatomical structures demo98765432 | 5/12/1971 (M) Study List 12/3/2019 9:45 AM | Adult Cardiac Priors 9:3 Scroll Lock Split Study 13 to 13 of 17 Calcs with rounded geometry, such as the left ventricular in the 01 - 5.74 cm D2 - 5.04 cm Circumference = 16,95 cm parasternal short-axis (PSAX) view. Area - 22.72 cm2 However, unlike the Distance Tool, the Ellipse Tool functioned as a general-purpose measurement without a standardized anatomical label. As a result, measurements obtained using the Ellipse Tool: 15cm • Required manual entry into the Worksheet. • Could not create ellipse-based calculations in the report designer. Did not support the Jump to measurement functionality. 49bpm • Template Effective Date: 26 Mar 2025 | QR700020784 6 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Ellipse Tool Enhancement (II) SIEMENS Healthineers In VA43A you can now associate Ellipse Tool measurements ACUSON SC2000 DEMO 0dB / MI: 1.07 / TIS: 0.85 01 - 5,14 cm D2 - 5,21 cm :36:42 AM . RETRO / U NE ECHO* / 4V1c Circumference - 16,26 cm Search ... Area = 21.04 cm2 with specific anatomical structures and create corresponding > 20 Left Ventricle measurements and calculations. LV Epi area d. PSAX pap Ellipse 66 fps / 160 mm LV Epi area s, PSAX pap Ellipse 47 bpm / NTHI General LV Epi Circumt d Ellipse -2D- H4.0MHz / 6 dB LV Epi Circumt s Ellipse TEQ: 1 / Offset: 3 dB This enhancement allows users to leverage all the benefits LV Epi major d Ellipse DR: 57 dB LV Epi major s Ellipse LV Epi minor d Ellipse known from tools like the Distance Tool, such as: LV Epl minor s Ellipse • Auto-populating diameters, circumference, and area values into worksheets. • Enables Jump to measurement navigation. • Optimizing routine workflows. Acquisition Date:26/04/2017 Acquisition Time: 11:36:44 A JPEG Lossy 20 1 11 of 41 YT Template Effective Date: 26 Mar 2025 | QR700020784 7 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Ellipse Tool Enhancement (III) SIEMENS Healthineers To create a measurement in Report Designer, follow Measurements and Calcs Definition Calc Type Cardiac Item Name New Measurement 1 Available In Cardiac these steps: Language English (United States) Display Name New Measurement 1 Category 00_Demo Ellipse 00_Demo Ellipse Units cm Name Stored in Database new_measurement_1_calc LV Epi Area s PSAX Ellipse LV Epi Circumf s Ellipse Usage Optional Data Context Study LV Epi major s Ellipse LV Epi minor s Ellipse Has an associated heart rate Displayed Precision 2 Open Report Designer. New Measurement 1 Has an associated Doppler Correction Angle • 2D O Carry Forward Include in Upload ACC v5 Alerting/Discrepancy Checking Go to the Libraries tab and select the [ Measurement has only one value Aorta Derivation Mean • Aortic Valve Tool Default Value ASD Measurement and calculations Library. ASE Quant Add New Row Remove Row Up Down AV Opt Blood Pressure DDB Label Tool Output Units Assign to Data Hide • Create a new measurement (1). Boston Z Scores CAPS CHOP Circle Container Functions Coronaries Coronary Arteries Doppler Ductus Duke Treadmill Score ECG EchoVacs Epsilon Evidence-based Logic O Allowed minimum and maximum of measurement: Fetal Min: cm Max: cm Note: Min/Max range must be positive when measurement is Find: defined with an absolute derivation. New Measurement 1 nce New Calculation New Category Hide Template Effective Date: 26 Mar 2025 | QR700020784 8 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Ellipse Tool Enhancement (VI) SIEMENS Healthineers To map and use an Ellipse Tool measurement in calculations, Definition Item Name LV Epi Area s PSAX Ellipse Available In Cardiac you must define all relevant component measurements. Display Name LV Epi Area s PSAX Ellipse Category 00_Demo Ellipse Units cm2 Name Stored in Database LV_Epi_Area_s_PSAX_Ellipse_calc These include (1): Usage Optional Data Context Study Has an associated heart rate Displayed Precision 2 Has an associated Doppler Correction Angle • Distance 1: Distance in the x-axis. O Carry Forward Include in Upload O • Distance 2: Distance in the y-axis. [ Measurement has only one value Derivation Mean Tool Ellipse Default Value • Circumference: The circumference of the ellipse. Add New Row Remove Row Up Down • Area: The area described by the ellipse. DDB Labe Tool Output Units Assign to Data Hide LV Epi Area s PSAX Ellipse area cm2 LV Epi Area s PSAX Ellipse 1 The Ellipse tool is used to measure areas on a 2d image. It has four outputs: - area: The area described by the ellipse. - circumference: The circumference of the ellipse. - distance1: Distance in the x axis. - distance2: Distance in the y axis. Allowed minimum and maximum of measurement: Min: cm2 Max: cm2 Note: Min/Max range must be positive when measurement is defined with an absolute derivation. Reference Hide Template Effective Date: 26 Mar 2025 | QR700020784 9 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Ellipse Tool Enhancement (V) SIEMENS Healthineers To create for example the PSAX ellipse area during systole, Definition Item Name LV Epi Circumf s Ellipse Available In Cardiac start with the necessary distance measurements involved in Display Name LV Epi Circumf s Ellipse Category 00_Demo Ellipse Units cm lame Stored in Database LV_Epi_Circumf_s_Ellipse_calc the ellipse area computation: Usage Optional Data Context Study Has an associated heart rate Displayed Precision 2 Has an associated Doppler Correction Angle • LV Epi major s Ellipse (cm). Carry Forward Include in Upload • LV Epi minor s Ellipse (cm). [ Measurement has only one value Derivation Mean 1 Ellipse Default Value 2D Caliper Pair Method of Disks love Row Up Down 2D Trace 2 Ellipse el Tool Output Units Assign to Data Hide Create these measurements as regular distance M-mode Distance pi Circumf s Elli circumference cm LV Epi Circumf s Ellipse M-mode Caliper Pair measurements using the 2D Caliper Pair Tool (1). 3 circumference Doppler Trace distance 1 Doppler Trace + 1 Caliper distance 2 Doppler Trace + 2 Caliper se tool is used to measure areas on a 2d image. It has four outputs: area: The area described by the ellipse. - circumference: The circumference of the ellipse. • LV Epi Circumf s Ellipse (cm). - distance1: Distance in the x axis. - distance2: Distance in the y axis. Create this measurement using the Ellipse Tool (2), and in ] Allowed minimum and maximum of measurement: Min: cm Max: cm Tool Output (3), select circumference. Note: Min/Max range must be positive when measurement is defined with an absolute derivation. Reference Hide Template Effective Date: 26 Mar 2025 | QR700020784 10 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Ellipse Tool Enhancement (VI) SIEMENS Healthineers Once the component values are defined, you can create the Definition Item Name LV Epi Area s PSAX Ellipse Available In Cardiac specific PSAX systolic ellipse area measurement: Display Name LV Epi Area s PSAX Ellipse Category 00_Demo Ellipse Units cm2 Name Stored in Database LV_Epi_Area_s_PSAX_Ellipse_calc Usage Optional Data Context Study LV Epi Area s PSAX Ellipse (cm2 ). Has an associated heart rate Displayed Precision 2 • Has an associated Doppler Correction Angle Carry Forward Include in Upload Use the Ellipse Tool (1) to define this measurement and add [ Measurement has only one value Derivation Mean Tool Ellipse 1 Default Value the previously created measurements within DDB (2). 2 Add New Row Remove Row Up Down DB Label Tool Output Units Assign to Data Hide LV Epi Area s PSAX Ellipse area cm2 LV Epi Area s PSAX Ellipse LV Epi major s Ellipse cm LV Epi major s Ellipse This created measurement can then be added to the LV Epi minor s Ellipse cm LV Epi minor s Ellipse LV Epi Circumf s Ellipse cm LV Epi Circumf s Ellipse worksheet, enabling the auto-population of values and the The Ellipse tool is used to measure areas on a 2d image. It has four outputs: Jump to measurement feature. - area: The area described by the ellipse. - circumference: The circumference of the ellipse. - distance1: Distance in the x axis. distance2: Distance in the y axis. Allowed minimum and maximum of measurement: Min: cm2 Max: cm2 Note: Min/Max range must be positive when measurement is defined with an absolute derivation. Reference Hide Template Effective Date: 26 Mar 2025 | QR700020784 11 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Ellipse Tool Enhancement (VII) SIEMENS Healthineers 1 In the workplace, you can apply Ellipse-based measurements ACUSON SC2000 DEMO 01- 5,14 cm D2 - 5,21 cm 1:36:42 AM by selecting them from the list when using the generic Ellipse Circumference . 16,25 cm Search ... X Area = 21,04 cm > 2D tool in the corner menu (1), or by choosing them directly ¥ Left Ventricle from the Calc Palette (2). LV Epl area d, PSAX pap Ellipse LV Epi area s. PSAX pap Ellipse LV Epi Circumt d Ellipse Airport Worksheet LV Epi Circumt s Ellipse 1.07 / TIS: 0.85 LV Epi major d Ellipse ECHO* / 4V1c Ellipse LV Epi major s Ellipse 2 2D LV Epi minor d Ellipse O Ellipse Circumferance LV Epi minor s Ellipse 56 fps / 160 mm Ellipse Distance 1 / NTHI General O Ellipse Distance 2 -2D- Ellipse Test1 V Left Ventricle H4.0MHz / 6 dB LV Epi area d, PSAX pap Ellipse 21, 1 / Offset: 3 dB O LV Epi area s, PSAX pap Ellipse 15,0 DR: 57 dB O LV Epi Circumf d Ellipse 16,26 cm O LV Epi Circumf & Ellipse 13,85 cm O LV Epi major d Ellipse 5,1 cm O LV Epi major s Ellipse 4,87 cm O LV Epi minor d Ellipse 5,21 cm O LV Epi minor s Ellipse 3,92 cm LV Epi PSAX EF Area Ellipse 28,68 Template Effective Date: 26 Mar 2025 | QR700020784 12 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Continuous HL7 patient update Template Effective Date: 26 Mar 2025 | QR700020784 13 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Continuous HL7 patient update (I) SIEMENS Healthineers The Enhanced HL7 features use HL7 messages, such as ADT and ORM to receive patient and order data from the hospital information system. These messages enable the system to automatically match patient demographics and order details with incoming studies. This supports accurate records and proper documentation and billing. Starting with VA43A, the feature now performs continuous patient/study reconciliation of study data at any time after the initial reconciliation. This ensures the system stays in sync with the connected EMR. Template Effective Date: 26 Mar 2025 | QR700020784 14 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Continuous HL7 patient update (II) SIEMENS Healthineers 1 The Enhanced HL7 feature allows syngo Dynamics to Configuration Tool: This application configures syngo Dynamics and the computer it runs on to execute properly continuously receive and process HL7 messages in real time. Once active, the system uses matching rules configured in the Network Settings | Site License | Computer Name | Thumbnails | Stress Review | Third Party Data| Web Services Description: Enterprise |Status Update |Active Directory |System Users |Server Notifications |Study List Query |EHS Department Mapping | Cache Settings |Philips Listener |SR/PR Creation|Critical Results |EMR Integration Matching Rule: Enable Patient ID option only if Configuration Tool (1) and SysAdmin (2) to automatically syngo.via HL7 Interface |FHIR Interface |Rules Engine |Database Backup |DB Alerts Site IDs are not used in any HL7 Ports Patient Demographics Update HL7 Mapping| Order Matching Rules department and when HL7 message does not contain Site ID Patient Demographic Updates (Assigning Authority). reconcile studies with the correct patient and order data. This Activate Patient ID and Site ID Enable Patient Demographic Updates when Site IDs are utilized in the system and included in the HL7 includes: Matching Rule message Note: Changing the Patient C Patient ID demographics matching rules mid- way may result in inconsistent ADT messages for demographic updates. Patient ID and Site ID patient updates and must be performed only after careful • consideration of the data already stored in the system. 2 in Department Settings X ORM messages for linking scheduled procedures or exams. : Help • Department: ULTRASOUND New Dept Delete Dept Reload Save Dept. |License |Site Ids Other Servers | Users Privileges | Study Types | Templates | Reports | Fax |Measurements | Export | Custom Exp Siemens Healthineers AG 2025. All rights reserved. Site IDs (All Departments) This eliminates the need for manual reconciliation when studies Selected Site ID Info {none) Site ID (none) Site Name None Demographic Matching Rules Study meet the matching criteria, saving time, reducing errors, and New Site ID, Patient ID, First Name, Last Name, Date of Birth Associate by Multiple Patient Numbers Master Patient Index Site ID, Patient ID, First Initial, Last Name Update Demographics Site ID Site ID, Patient ID, Date of Birth Associate Orders ensuring accurate report linkage. Site ID, Patient ID Patient ID, First Name, Last Name, Date of Birth Accession Number (Filler Order Number) Edit C Modality Accession Number First Initial, Last Name, Date of Birth HL7 Filler Order Number First Initial, Last Name C Generate If a study doesn’t match due to data issues, the system alerts W Master Patient Index must exist in successful match Order Matching Rules Filler Order Number vs. Study Accession Number the user for manual correction using the HL7 Reconciliation Observation Date vs. Study Date And Universal Service ID vs. Study Description Observation Date vs. Study Date Universal Service ID vs. Study Description Tool, just as before. Unique Match on Demographics Only AE Titles (All Departments) Select default Site ID for the AE Title Default Site ID {none} Reset Default Site ID Template Effective Date: 26 Mar 2025 | QR700020784 15 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Continuous HL7 patient update (II) SIEMENS Healthineers With the Enhanced HL7 license in syngo Dynamics VA43A, SIEMENS Healthineers syngo Dynamics patient demographic data is continuously updated in real time. R 1 Patient demographics have been updated .0) Study List 6/15/2012 9:15 AM Priors 4:1 Scro When a study is open and updated patient information 15-06-2012 PHILIPS 9:16:54 becomes available in the background (1) a new icon may appear in the Workplace. Patient demographics have been updated This icon alerts users that the study may not reflect the most current data. When the icon appears: Please note: Refresh or reload the study to apply updates. • The Enhanced HL7 feature requires a valid Review the changes for accuracy before proceeding. license and proper configuration. For ... syngo® Dynami • Operator Manual - Syste VA43 setup, refer to the HL7 Interface ---- H. specification and the SysAdmin manual or ..... syngo® Dynamics contact your Siemens Healthineers Online Help - HL7 Reconciliation Tool Manual (Standalone) VA42 representative. Healthine Template Effective Date: 26 Mar 2025 | QR700020784 16 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Workplace Client Multi-Session Virtual Deployment Template Effective Date: 26 Mar 2025 | QR700020784 17 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Workplace Client Multi-Session Virtual Deployment (I) SIEMENS Healthineers With the VA43A release, syngo Dynamics Workplace now supports multi-session deployment on Azure Virtual Desktops (AVD). This allows multiple users to access syngo Dynamics concurrently from a single Windows client OS hosted in the Azure cloud. This deployment model is intended to provide a scalable and efficient alternative to traditional virtual desktop infrastructure (VDI) setups. Template Effective Date: 26 Mar 2025 | QR700020784 18 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Workplace Client Multi-Session Virtual Deployment (II) SIEMENS Healthineers syngo Dynamics Workplace has supported virtualization via Citrix, where the application is hosted on a Windows Server-based Citrix environment. This remains a supported configuration. However, Citrix environments require dedicated server OS licensing, careful resource planning, and significant infrastructure considerations. Additionally, Citrix does not support Windows 10/11 multi-session VMs such as those used in Azure Virtual Desktop. Template Effective Date: 26 Mar 2025 | QR700020784 19 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Workplace Client Multi-Session Virtual Deployment (III) SIEMENS Healthineers Benefits of Azure Virtual Desktop Deployment • Concurrent Access: Multiple users can log into the same virtual machine and run syngo Dynamics simultaneously. • Simplified Maintenance: Only one OS instance needs to be patched and maintained, reducing administrative overhead. • User Transparency: From the end-user perspective, the experience remains consistent. Each user has their own desktop session and can run syngo Dynamics and third-party applications independently. Template Effective Date: 26 Mar 2025 | QR700020784 20 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Workplace Client Multi-Session Virtual Deployment (IV) SIEMENS Healthineers Limitations and Considerations for Multi-Session Environments • Azure-Only Availability • Multi-session is supported exclusively on Windows client operating systems hosted in the Azure cloud. It is not available for physical machines or standalone installations, and traditional Windows OS (e.g., Windows 10/11) only allows one user session at a time outside Azure. • Licensing Requirements • Each user session requires an individual license for third-party applications. Multi-session usage does not reduce overall license consumption. Template Effective Date: 26 Mar 2025 | QR700020784 21 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Workplace Client Multi-Session Virtual Deployment (V) SIEMENS Healthineers • Third-Party Application Compatibility • Compatibility with third-party applications may be limited. The following applications are currently not supported in a Multi-Session Environment, based on direct collaboration with vendors: Circle CVI42, Epsilon, GE EchoPAC, Philips QLab Pie Medical CAAS, and TomTec Arena. It is recommended to validate application support before deployment. • Functional Limitations Certain operations are not supported in a multi- session setup, including: • Exporting studies to CD/DVD/USB. • Simultaneous importing from a shared folder by multiple users. Template Effective Date: 26 Mar 2025 | QR700020784 22 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Sequoia Mapping tab in SysAdmin Template Effective Date: 26 Mar 2025 | QR700020784 23 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Sequoia Mapping tab in SysAdmin (I) SIEMENS Healthineers syngo Dynamics is continuously advancing to meet Ww SysAdmin Department Settings X File Edit Help customer expectations and emerging IT capabilities. Denartment: Test New Dept Delete Dept Reload Save 1 ervers | Users | Privileges | Study Types | Templates | Reports | Fax | Measurements | Export | Custom Export |Integration Diagram:4 ) As part of this progression, certain legacy elements are Sequoia Mapping Generic Launcher | Rules Engine | being phased out to make way for more current and Sensis Server Configuration Sensis Machine Name Sensis System Integration efficient solutions. Sensis Database Name Date Sensis Installed Sensis Login Name June 12, 2025 - The With the release of VA43A, the Sequoia Mapping tab (1) Sensis Login Password Validate Sensis Configuration has been removed by default from the SysAdmin interface. This change applies universally, regardless of whether the customer was using the Sequoia Mapping tab previously Please note: or not. Clear instructions on how to re-enable the H. Sequoia Mapping tab can be found in the ..... syngo® Dynamics For customers who will still require access to the Sequoia Operator Manual - System Administration Manual VA43 Mapping tab, it can be easily re-enabled by the System Administration Manual. Healthineers Implementations Team. Template Effective Date: 26 Mar 2025 | QR700020784 24 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Support and compatibility update Template Effective Date: 26 Mar 2025 | QR700020784 25 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 Support and compatibility update (I) SIEMENS Healthineers In VA43A, the newly supported system and compatibility updates are as follows: System Version Please note: cvi42 6.2.2 The syngo Dynamics client should be updated first, followed by the cvi42, to prevent any complications. H. syngo.via VB80F Template Effective Date: 26 Mar 2025 | QR700020784 26 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025 SIEMENS Healthineers Please note that this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product-related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration-dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim, Germany Phone: +49 9191 180 siemens-healthineers.com Template Effective Date: 26 Mar 2025 | QR700020784 27 Job Aid Effective Date: 08 Aug 2025 | QR700026871 Published by Siemens Healthineers AG I © Siemens Healthineers, 2025
- va43a
- dynamics new
- caridac va43a
- QR700026871