
syngo Dynamics - What's New in VA41E
These delta training slides provide you with an overview of the feature enhancements with the software VA41E.
Target group: Clinical Users, Clinical Admins, IT Admins
Recommended to be viewed on the following devices: All (incl. tablet, smartphone)
SIEMENS Healthineers syngo Dynamics What’s new in VA41E? Template Effective Date: 10 Aug 2021 | HILS 2223 Job Aid Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 syngo Dynamics: What’s new in VA41E? SIEMENS Healthineers Table of contents VA41E feature enhancements: syngo Dynamics and syngo.via enhanced integration 5 Redefining the order in Study Banner 14 Redefining the order in prior studies 16 Image sorting 18 Display settings 21 Display of ePDF data 25 New Auto EF Variables 27 Continuous Worksheet scroll in Report Designer 29 Using dates in calculations in Report Designer 31 New MRI report and worksheet template 36 Language support 42 Support and compatibility update 44 2 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Introduction SIEMENS Healthineers These training slides will introduce you to the feature enhancements when updating your syngo Dynamics system to software version VA41E. Please note: These slides are optimized for clinical and administration users and some features may not be described. Please refer to your user documentation or your Siemens Healthineers Service Representative for further information. 3 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Find the right training for your software version SIEMENS Healthineers 1 To learn about the changes to your system, it is important 3 About syngo Dynamics version VA41E to know the previous software version installed. ? DN ULTRASOUND / SDXAPPS X Siemens Healthineers AG. 2024. All rights reserved. This Application and its Documen Additionally, you should be aware of your current (new) proprietary to Siemens Healthineers and contain works by Siemens Healthineers and its suppliers User Manual ff claimed. This Application may only be used in strict accordance with the terms of the license agreement(s) software version. The Application may contain embedded Third Party Software including Free and Open Source Sc Measurement and Calculation Manual right to use OSS delivered with the Applications is governed by the terms of the OSS license ac( such license are included as part of the Documentation and located on the OSS labeled medi media binder. The OSS is licensed to Customer royalty free; however, Siemens Healthin reimbursement of costs in connection with complying with the OSS license terms. In the even Release Notes You can check your current software version on your syngo terms of an OSS license and the Agreement, the relevant terms of the OSS license shall govy component to which they relate. If delivery of source code is required by the relevant OSS licen Stat copy of the source code for such OSS by accessing the OSS labeled media provided in the softwar 2 About Dynamics Workplace directly. time of Application purchase. Siemens Healthineers may from time to time change the nunFA Siemens Healthineers will in each case include the relevant license terms and conditions as par Updates, Releases or Versions. (01) 04056869984735 GTIN HEAD PEPconnect :C (240) 11707704 MODEL (422) 840 ORIGIN US • Click on the Help menu (?) in the top right of the user (8012) VA41E SW-VERSION interface (1). Manufacturer: Siemens Healthineers Headquarters: Product Identifier: Siemens Healthcare Gmbh Siemens Healthineers AG Product Name syngo Dynamics Henkestr. 127 Siemensstr. 3 Product Version VA41E 91301 Forchheim • Select About (2). 91052 Erlangen Germany Germany Phone: +49 9131 84-0 Build Number 40.0.0.8912 ciamanc.haalthingare rom • Your current syngo Dynamics software version is Microsoft SQL Server 2016 (c) Microsoft Corporation. All rights reserved. Microsoft SQL Server 2019 (c) Microsoft Corporation. All rights reserved. displayed in the About section (3). lonosoft Inc ., Visual Cath Report is covered by U.S. Patent No. 7,949,542 Electronic Instructions for Use ionosoft doclib.siemens-healthineers.com 2024 MD Please check with your System Administrator or your CE 0123 Siemens Healthineers Service Representative which software version was previously installed on your system. Please note: Certain features require a license and may not be available on your system. 4 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E syngo Dynamics and syngo.via enhanced integration 5 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo Dynamics and syngo.via enhanced integration SIEMENS Healthineers syngo Dynamics has supported integration with syngo.via SIEMEN olthincers 2 Viewing AFR for quite some time, allowing you to review CT and MRI Series MR_Cardiac_Analysis Ay Full Case MR Cardiac Analysis Av Full Case Agranito VB13 *1/1/1925. F.81Y ........... *1/1/1925; F. 81Y Avanto images from the syngo.via database. CURRENT CURRENT 7/28/2006 7/28/2006 Cine Segmented LA Localizer @ Isocenter Cine 4 chamber/latest latest 10:18:41 AM 10:13:53 AM 6 IMA 14 FRM 1/1 2 IMA 1 FRM 1/1 In previous versions, opening either the current or prior ........... RHP 20 3L 60 study in syngo.via allowed a maximum of one prior study in SL 80 32.0 SP R2.0 syngo Dynamics. TT 494 TT 740.0 Zoom 2.03 TR 39.8 TR 337.1 . 3019% TE 1.1 p2 M/RETRO/DIS2D TE 12 452 12 M/DIS20 Favorite Tools . 50/1995 CH42, CarducMR G4421234567 *1/1/1951. M. STY Aura In VA41E, you now have the possibility to open up to two CURRENT STUDY 2/04/2018 CUSENT Difeelingasis 12:03:23 PM studies from syngo Dynamics and up to four CT/MR studies 7 MA1 PRH from syngo.via simultaneously. SPC 10cm RIA SPL37.4 Zoom 255 A 6 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo Dynamics and syngo.via enhanced integration SIEMENS Healthineers In previous versions, you had to manually open the report and worksheet when opening a syngo.via study in syngo Dynamics. In VA41E, the setup has been enhanced to - -- = automatically open the report and worksheet when opening a CT/MR study using syngo.via. 7 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo.via as the primary study SIEMENS Healthineers You can open a syngo.via study as the primary study in syngo 1/10/2019 8:36:00 AM UNREAD Nearline US Dynamics by choosing the study on the Study List (1). 1/10/2019 2:12:57 PM UNREAD Nearline US 7/6/2022 11:41:00 AM UNREAD Nearline US 6/2/2022 10:21:01 AM UNREAD Nearline US 1 When syngo.via is the primary study, you can open up to three 9/24/2024 11:21:27 AM UNREAD External MR prior syngo.via studies. 9/9/2024 10:01:27 AM READ External MR 9/10/2024 10:13:44 AM READ Online US If necessary, one prior syngo Dynamics study can also be opened, giving you five studies to compare. 2 SIEMENS Avalthingers The syngo Dynamics studies are displayed on the primary MR Cartbac Msa SIEMENS SIEMENS Healthineers Departvert Healthineers R/W Syngo CURRENT CT Carlothoracic Report IKKOKARDIOGRAFE monitor and the syngo.via studies on the secondary monitor. R/W 25-09-3004 Javel 108 13 67 AM deno TAMi post primary Dynamics CI FINDENGG TTT40G 12 1.1 2 MGETHOC 320 The report and worksheet of the primary syngo.via study are syngo Via modalita type are displayed on the primary monitor (2). 8 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo Dynamics as the primary study SIEMENS Healthineers When the primary study is a syngo Dynamics study, you SIEMENS Acolthineces MR_Cardiec_Analysis can compare up to two syngo Dynamics studies with four CURRENT CURRENT T25/200€ 10:13:53 AM MA ! FEM In syngo.via studies. 20 11 2410 TR 337 1 TE 12 In total, you can compare up to six studies. The primary and prior syngo Dynamics studies are displayed on the primary monitor and the prior syngo.via studies on the secondary monitor. Please note: Enable the dual monitor with syngo.via in Display Configuration. 9 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo Dynamics and syngo.via multiple studies SIEMENS Healthineers Compare tool You can choose the additional studies with the 1 Quick Search Compare tool or via the Priors tab. Cc PD Study Date Study Status Study Location Modality 3/23/2022 10:12:00 AM UNREAD Nearline US The Compare tool: 1/10/2019 8:36:00 AM UNREAD Nearline US 1/10/2019 2:12:57 PM UNREAD Nearline US The first study that you select on the Study List is 7/6/2022 11:41:00 AM UNREAD Nearline US • 6/2/2022 10:21:01 AM UNREAD Nearline US the primary study. ? 9/24/2024 11:21:27 AM UNREAD External MR To add additional studies, press Ctrl on your 9/9/2024 10:01:27 AM READ External MR • keyboard + left-click on the studies (1). 9/10/2024 10:13:44 AM READ Online US SIEMENS .... 2 Healthineers syngo Dynamics Utilities • Now, in the Study tab, select the Compare tool (2). Patient Study Quick Search Mark Study As Read The studies are opened in comparison mode. Mark Study As Unread • Cc PD Stud Create Study ... Near If you exceed the number of syngo.via studies you Compare Near • Near are allowed to compare, the Compare menu is Save Study List To File ... Near disabled. Assign Study to Dept Near ? Import Studies To SV25025 Onlin 19 Export Studies To ... Onli Onlil 10 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo Dynamics and syngo.via multiple studies SIEMENS Healthineers Priors tab Priors tab 1 SIEMENS Healthineers .. syngo Dynamics H Priors 4:1 Scroll Lock Split Study • If you have already opened your primary study, Study List TTE 15 CT CT External CT \ SYNDYN3 you can choose additional studies via the Priors X5-1 TISO.3 MI 1.2 53Hz + IVSd 1.06 cm CT CTSR External CTI SYNDYN3 19cm #: LVIDd 5.03 cm 2D &LVPWd 1.00 cm tab (1). 63% EDV (2D-Teich) 120 ml 6/27/2019 12:30:40 PM Current Study C 50 P Low IVS/LVPW (2D) 1.06 HGen External CTI SYNDYN3 UNS CT CTSR External CT \ SYNDYN3 • This option gives you a chronological list of this 2 OR3 CT CT External CT \ SYNDYN3 CT CTSR External CT \ SYNDYN3 patient’s studies. 1.3 2.6 • Press Ctrl + click and on the desired studies. 580pm 12 580pm TTE TISO.4 MI 1.2 TIS0.4 MI 1.2 X5-1 • The studies are opened in comparison mode. 90Hz # Ao Sinus Diam 3.76 cm 90Hz 16cm % Ao STJ Diam 3.29 cm 15 cm 2D H Asc Ao Diam 3.7 cm 63X 83% C 50 C 50 P Low P LOW HGen 11 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo Dynamics and syngo.via enhanced integration SIEMENS Healthineers Number of prior studies If you attempt to open an additional prior study, a message is displayed to advise you that the maximum number of Maximum # of Priors Open X prior studies is open. i You have opened the maximum number of Prior studies allowed. Please close previously opened prior study before opening another study. OK 12 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo Dynamics and syngo.via enhanced integration SIEMENS Healthineers Close patient When you close the study from syngo.via or if you return to the Close Patient ? X Study List in syngo Dynamics, syngo.via displays a Close Patient How would you like to close the patient CT_NM_BONE_ABDOMEN_1297 dialog. V Sovr and Send Save and Pause Select how you would like to close the patient. X Discard Changes • Save and Send: The results are stored on syngo.via and Cancel sent to your archive. Cancel button available when closing study directly from syngo.via. • Save and Pause: Results are stored on syngo.via. Close Patient How would you like to close the patient COLLINS, BABY BOY? Discard Changes: Unsaved results will be lost. V Save and Send • (Results are stored on the system and sent to your archive |CTRL + ALT +AD 11 Save and Pause Save and Pause Auto logoff triggers Save and Pause. X Discard Changes (Unsaved results will be lost) Cancel button not available when closing study by navigating to Study List. 13 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E Redefining the order in the Study Banner 14 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Redefining the order in the Study Banner SIEMENS Healthineers Previously, the Study Banner order displayed the patient’s 1 surname, first name, and then the patient ID on the same line. SIEMENS Healthineers syngo Dynamics In some cases, with long patient names, the patient ID was not Larspetersdatter, Annemette-Sophie | 1 O visible (1). 3/2/1911 (F) Study List TTE | 8/21/2024 11:30 AM Larspetersdatter, Annemette- Sophie | 125489367458 In VA41E, the Study Banner order has changed to accommodate this. The current display order is (2): 2 SIEMENS Surname, first name Healthineers syngo Dynamics • O • Patient ID, site ID, date Of birth, (gender) Larspetersdatter, Annemette-Sophie 124589367458 (F) Study date/time, study description Study List 9/17/2024 2:33 AM | Adult Cardiac Priors • Please note: The Study Banner information may vary depending on the configuration setup. 15 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E Redefining the order of prior studies 16 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Redefining the order of prior studies SIEMENS Healthineers The Priors tab previously displayed the current study first with 1 the other prior studies arranged per department (1). 5 Priors 4:1 Scroll Lock Split Study 1 to 4 of 18 Enterprise Search AdultEcho \ SDXSERVER Current Study 10/5/2019 Echo, Patient demo023345 9/17/2024 Adult Cardiac US Online Echo, Patient demo023345 4/22/2020 Adult Cardiac US Online Echo, Patient demo023345 12/3/2019 Adult Cardiac US Online Echo, Patient demo023345 12/3/2019 Adult Cardiac US Online Echo, Patient demo023345 8/29/2018 Adult Cardiac US Online In VA41E, all studies are displayed in chronological order, to 2 provide a better overview and study time is displayed before Priors 4:1 Scroll Lock Split Study 1 to 4 of 20 the patient's name (2). 2/23/2024 10:45:16 AM Study, Adult Cardiac demo45654345 Adult Cardiac 10/5/2019 1:30:14 AM Study, Adult Cardiac demo45654345 Adult Cardiac 5/1/2018 5:33:35 PM Current Study 5/1/2018 5:33:35 PM Study, Adult Cardiac demo45654345 Adult Cardiac 7/22/2015 8:38:28 PM Study, Adult Cardiac demo45654345 Adult Cardiac 17 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E Image sorting 18 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Image sorting SIEMENS Healthineers Prior to VA41E, images were sorted by acquisition date/time, which sometimes resulted in images being displayed out of sequence. As an example, some modalities use the acquisition time 1 from the image where a secondary capture is taken. This caused the image number sequence in syngo Sull Dynamics to appear out of order. Images were displayed based on acquisition time with a 79 later image number e.g. #79, #102, #80. (1) 102 80 A JPEG Lossy 18:1 1 19 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Image sorting SIEMENS Healthineers In VA41E, you can now change the sort order of images to San use one of the following: • Acquisition date/time (default) • Image date/time • Image number Using our previous example, sorting by image number would display images in the correct number sequence. 79 A JPEG Lossy 21:1 80 JPEG Lossy 18:1 Changes to image sorting are done on the server and will affect all departments. Please note: Stress echo images will maintain the correct To make this change, please contact your local IT display of stages and views. However, duplicate stress echo administrator or Siemens Healthineers Service images will follow the configured sort order. Representative. 20 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E Display settings 21 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Ability to scale report component on high-resolution monitor SIEMENS Healthineers In VA41E, there are new display settings, allowing 1 SIEMENS Healthineers syngo Dynamics ? CH Cardiologist, Hospital AdultEcho / SDXSERVER Adult Echo, Patient | 1234 8/3/1963 (F) V Study List Adult Heart | 12/3/2019 9:45 AM Priors Scroll Lock Mark Stu ... Caks you to adjust the display of the report and 0 to 0 of 17 Thumbnat Report Worksheet Ve Physician Pt Calcs TEE LV RV LA IAS RA AOV MV TV PV CHD Ao/PA Pericrd Other Summary PATIENT AND STUDY INFORMATION Past Medical History/Events worksheet. Page 1 of 2 Message Center (these comments are not shown on report) SIEMENS CARDIOVASCULAR MEDICAL CENTER 1234 Arbor Drive Healthineers Ann Arbor, MI 48106 Discrepancy Checked 1 (888) 796-4639 Patient Demographics Information Prefix First TRANSTHORACIC ECHOCARDIOGRAM REPORT Last Suffix Pt. Name: Patient Adult Echo Pt Name: Patient Adult Echo Study Date: 12/3/2019 MRN: 1234 Birth Date: 8/3/1963 Patient MRN: 1234 This allows you to adapt the font size and space Accession #: demo 1234 Custom Field 1: Patient Age: 56 years Accession Number: demo1234 PL Gender: Admission ID: NN1234 Admission ID: NN1234 Custom Field 2: PL. Height 70.5 in (179.0 cm) BSA (Dubois): 1.88 m2 Pt Weight: 154.3 lb (70.0 kg) Blood Pressure: 104/71 mmHg Admission status: Ht: 179 cm 70 in Referring Physician: Referring Physician Date of Birth: 8/3/1963 Age: 056Y Wt: 70.00 kg / 154 lb allocation for the report and worksheet Interpretting Physician: Hospital Cardiologist Gender: F BSA (DuBois): 1.88 m2 SUMMARY 1. Normal echocardiogram. BP: 104 / 71 mmHg 2. No evidence of ischemic, valvular, hypertrophic, or pulmonary heart ADDITIONAL STUDY INFORMATION components on the primary monitor. This makes disease. Study Information 3. No evidence of any valvular vegetations. Study Date/Time: 12/3/2019 at 9:45:49 AM 4. No evidence of pericardial effusion. SIEMENS Healthineers syngo Dynamics Cardiologist. Hospl PHYSICIAN INTERPRETATION Adult Echo, Patient | 1234 working more comfortable, especially on high- Left Ventricle: 8/3/1963 (F) Study List Adult Heart | 12/3/2019 9:45 AM Priors Scroll Lock Mark Stu ... Cales worksheet Normal left ventricular size 0 to 0 of 17 Physician y Pt Calcs TEE LV RV LA IAS RA AOV MV TV PV CHD Ao/PA Pericrd |Other Summary resolution monitors (1). Right Ventricle: Right ventricular size and systolic function are within normal limits. PATIENT AND STUDY INFORMATION age 1 of 2 Page 1 of 2 Message Center (these comments are not The left atrium is normal in size and structure. Right Atrium: The right atrium is normal in size and structure. CARDIOVASCULAR MEDICAL CENTER Interatrial Septum: 1234 Arbor Drive The interatrial septum appears normal and intact, wit Ann Arbor, MI 48106 This change will not affect the syngo Dynamics 1 (888) 796-4639 Patient Demographics Information Aortic Valve: The aortic valve is trileaflet and structurally normal, w First evidence of aortic stenosis or regurgitation. CARDIOGRAM REPORT Prefix M Pt. Name: Patient Adult E workplace. Study list, menu icons, and so on will Patient Adult Echo 1234 Final Study Date: 12/3/2019 Patient MRN: 1234 MRN: 1234 Accession Number: demo 1234 Accession #: demo1234 Cust Admission ID: NN1234 not change. Report is locked and cannot be edite BSA (Dubois): 1.88 m2 Admission ID: NN1234 Cust Blood Pressure: 104/71 mmHg Admission status: Date of Birth: 8/3/1963 Age: 056Y Gender: F lypertrophic, or pulmonary heart BP: 104 / 71 mmHg ions. Study Information Study Date/Time: 12/3/2019 at 9:45:49 AM Study Type: Adult Heart Image quality: normal systolic and diastolic function. 12/3/2019 Report Title: Transthoracic Report is locked and cannot be edited Study is marked as read and worksheet cannot be edited 22 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Ability to scale report component on high-resolution monitor SIEMENS Healthineers Report and Worksheet Scaling Configuration To adjust the display of the Report and Worksheet, open Display Display Configuration X Configuration. Left click to select or deselect the monitors that will be used by the syngo Dynamics application. A [1504 x 1063] maximum of 2 monitors can be chosen. Right click on the secondary monitor to share or unshare with the syngo.via application. In Report and Worksheet Scaling Configuration (1), you will find Application must be restarted to reflect the saved configuration. the option to change: Image Display Size Variation • Horizontal space allocation (%) determines how much space Use this setting to reduce the size of images displayed 25 on the primary monitor relative to images displayed in Image Display Size Variation - Max Layout (%) the report and worksheet are allowed to take up on the another window or monitor. Size reduction is based on percent. Values between 0% and 75% may be specified. The default value is 25%. Change the image Image Display Size Variation - All Other Layouts (%) 25 display layout or close and reopen the study to apply primary monitor. the new setting. Default Worksheet Configuration Auto fit text size to space: If this is On, the system depicts the 1 • Activate continuous scrolling function for Worksheets Continuous scrolling for Worksheets O space allocation and font size that best fits the screen, based 1 Report and Worksheet Scaling Configuration Set your horizontal space for the primary monitor to manage the allocated space for Report and Worksheets. Horizontal space allocation (%) 54 X on the system monitor resolution. Auto fit text size ON eliminates the horizontal scroll bar. Auto fit text size to space O On Off Auto fit text size OFF allows to adjust the scaling factor independent of the system settings. Adjust scaling factor (%) 100 Current system scaling (%) 100 Reset the scaling factor to the system settings. Reset scaling factor Default Save Cancel 23 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Ability to scale report component on high-resolution monitor SIEMENS Healthineers Report and Worksheet Scaling Configuration Display Configuration • Adjust scaling factor (%): This lets you adjust the font size X related to the monitor resolution. It is only possible if auto-fit Left click to select or deselect the monitors that will be used by the syngo Dynamics application. A [1504 x 1063] maximum of 2 monitors can be chosen. is Off. Right click on the secondary monitor to share or unshare with the syngo.via application. Application must be restarted to reflect the saved configuration. This setting cannot be less than the current system scaling. Image Display Size Variation • Current system scaling (%): This shows the current scaling factor set for your monitor. Use this setting to reduce the size of images displayed on the primary monitor relative to images displayed in Image Display Size Variation - Max Layout (%) 25 another window or monitor. Size reduction is based on percent. Values between 0% and 75% may be specified. The default value is 25%. Change the image Image Display Size Variation - All Other Layouts (%) 25 This is read-only in syngo Dynamics. display layout or close and reopen the study to apply the new setting. Default If you want to change this, go to the monitor display Worksheet Configuration 1 settings on your computer and make the changes Activate continuous scrolling function for Worksheets Continuous scrolling for Worksheets O 1 there. Report and Worksheet Scaling Configuration Set your horizontal space for the primary monitor to manage the allocated space for Report and Worksheets. Horizontal space allocation (%) 54 X Auto fit text size ON eliminates the horizontal scroll bar. Auto fit text size to space O On Off • Default: Resets the system to the space allocation and font Auto fit text size OFF allows to adjust the scaling factor independent of the system settings. Adjust scaling factor (%) 100 size that fits the best, based on the monitor resolution Current system scaling (%) 100 (without vertical scroll bars). Reset the scaling factor to the system settings. Reset scaling factor Default Save Cancel 24 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E Display of ePDF Data 25 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Display of ePDF Data SIEMENS Healthineers SIEMENS In the previous version, we were not able to display Healthineers syngo Dynamics Patient, ECG Data 12345678 | 7/7/1980 (MALE) Staly Lat 425/2023 10:36 AM | Stress Echo DICOM encapsulated PDFs in image review in syngo SIEMENS . CARDIOVASCULAR MEDICAL CENTER 1234 Arbor Drive Name: Date of Birth Healthineers Damm: 1/14/2021 Ann Arbor. M 48106 1 (881) 796-4639 ID number. Gender: Chanmet 102 Page: 3/12 Stress Echocardiogram Report Heart rate Dynamics e.g. Sensis Hemo waveforms with VD15B in PL Nane ECG Data Paden Birth Date Preli 4/25/2023 Pagine Age 7/7/1980 42 years 12345478 1. 10 2048 Pt Gender Accesoon Numde BSA (Dubois) 0:00 ml Body Mass index Sealy Tros ECG Stadty Date 6/27/2021 addition ECG or Holter reports. BASELINE FINDINGS STRESS FINDINGS Stress ECG and Blood Pressure 103 % of The peak heat rate achimed was 155 bom. ECG Data: Max Systolic BP Max Diastolic BP In VA41E, ePDFs sent to syngo Dynamics are Peak 9tess HR 24 Heart rate, recording Sopraventricular arrhythaies Vostricular arrhythmiaa Max ST on Exercise Mas ST m Recovery -- Heart Rates: metada tatal taoplats tatali automatically converted to a secondary capture image. Resteg Haat Rats vi triplane tatell Max Age Predictet HR (MAPR) 177 bpm 155 bpm 204122 VE tanky ... % ./ MAPR Adines % of Target Achiend Bradycardie and Ofe (per minute) NT analysis (per minute) ======= Electronicaly signed by SIEMENS Healthincers Sgogo Dynamics cvi42. CanSacMx This allows you to review the content of the ePDF in Cvi421234567 | 1/1/1951 () 2/24/2018 11:59 AM | MR Patient Imaging Data Ca Score Coronanies Cardias Aorta Incidentiil Summary Patient SIEMENS Facility Name PATIENT AND STUDY SWFORMATION syngo Dynamics image review. Facility Address Message Center (commmes are not shown an report) Healthineers Department CT Cardiothoracic Report Siemens Healthcare Gmbh Patient Name: FO_525 Pr 3say bia! 6/27/2019 Cardiac Catheterization Report Menkestr. 127. 91052 Erlangen MRN: FO 525 Accession Pt. Nonve 10 525 Gensany Number: MAN: FO_525 Birth Date: 1/1/1909 Age: 110 years Gender. Height: Accession Number: 1 This configuration is done on the server and can be Custom Field demo TAVI post O Weight Date of Birth: 1/1/1999 Hoe: 110Y Custom 1: demo TAVI post. Gender: 0 Button 2: -- Adattion Site disabled if e.g. Hemo waveforms are sending as DICOM CT FINDINGS: Coronary Arteries: Study Date: 6/27/2019 Sandy Time: 12:30:40 PM Left Main: A normal sized artery. Arises normally from the left sinus, of Valsalva and Study Type: CT divides into the left anterior descending and circumflex coronary artistes. Calcified Report Title: CT Cardiothoracic Carry forward Image. atherosclerotic plaque. Mild stenosis (25-49%) Left Anterior Descending Artery: A normal sized artery which gives off two diagonal Procedures branches. Non-calcified atherosclerotic plaque. Minimal stenosis (<25%). indicatore Requesting Ptryucan: Send Report To: Send Report To: Interpreting Physician: Technologist: Fellow: SIEMENS Healthineers 26 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E New Auto EF Variables 27 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 New Auto EF Variables SIEMENS Healthineers In VA41E to distinguish between measurements generated by the Worksheet Data Palette Auto EF algorithm and manually drawn measurements, the Patient|Calcs Observations Phrases Layout system stores these values in separate report definition variables. SDx AI sDx AoV Mean Grad AI sDx AoV Pk Grad AI The measurement from the Auto EF algorithm have a new sDx AoV Vmax AI SDx AOV VTI AI suffixed with "AI" to indicate they are from the Auto EF algorithm. SDx IVS d, 2D AI SDx IVS s, 2D AI sDx LV area d, A2C AI Any customer using Auto EF and reporting will need to update sDx LV area d, A4C AI their templates to include the new Auto EF variables. The new sDx LV area s, A2C AI sDx LV area s, A4C AI variables can be found under the sDx AI category in the SDx LV d, 2D AI SDx LV EF, MOD A2C AI Measurement and Calc Library. SDx LV EF, MOD A4C A SDx LV EF, MOD BP AI 1 SDx LV major d, A2C AI In the Worksheet Data Palette the Auto EF measurement is found sDx LV major d, A4C AI under Calcs and sDx AI (1). sDx LV major s, A2C AI sDx LV major s, A4C AI SDx LV s, AI SDx LV vol d, MOD A2C AI SDx LV vol d, MOD A4C AI Find: Calc Type Cardiac v 28 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E Continuous Worksheet scroll in Report Designer 29 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Continuous Worksheet scroll in Report Designer SIEMENS Healthineers Since VA41C it has been possible to select the setting Continuous syngo Dynamics Report Designer - MFM 1st Trimester.kwt File Edit View Libraries Tools Help scrolling for Worksheets. Times New R v Design Physician Preview 1 Preview With Continuous Worksheet Scroll In VA41E this option has been added to VA41E Report Designer mens Medical Center Show Study Data Address preview. Show All Data Telephone Show Annotations bstetrics and Gynecology Maternal-Fetal Medicine Template Cross Reference Thereby giving you the ability to preview your worksheet design ADDENDUM TO PRIOR ECHOCARDIOGRAM REPORT Reason for Amendment: < ... ent Reason> in scroll mode (1). on 13-10-2024 at 17:23:41 OBSTETRIC ULTRASOUND REPORT Pt. Name: John Doe Study Date: 01-01-2023 Birth Date: 01-01-1938 Patient MRN: A33578.1023872768 Patient Age: 85 years Accession Number: < ... ion Number> Pt. Gender: ............... F Account Number: < ... mission ID> Pt. Height: 65,0 in (165,1 cm) Admission Status: Pt: Weight: 125,0 lb (56,7 kg) Patient's Previous Name: Ordering Provider: Referrring Physician: Marcus Bonnae Primary Sonographer: Jameson 30 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E Using dates in calculations in Report Designer 31 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Using dates in calculations in Report Designer SIEMENS Healthineers Dates Prior to VA41E you were not able to use a date in calculations in Pt Maternal Pregnancy Fetus Findings Summary CVS PATIENT INFORMATION set normal PAST MEDICAL HISTORY Report Designer. Study Date & Time: 01-01-2023 - 19:46:08 Pre First M Last Suffix Patient Name: 1st tr SINGLE Med Rec #: 070704 755 Maternal alias: In VA41E Report Designer, you can create date-based calculations. Accession #: Birth Date: 24-05-1992 Other Pt. ID: Age: 30,6 years Account #: Gender: O Admission status: The date-based calculations can result in: Custom 1: Height: 70,9 in / 180,0 cm Custom 2: Weight: 220,5 lb / 100,0 kg ORDER INFORMATION ADDITIONAL STUDY INFORMATION Study Type: OB • Dates e.g. next visit date based on today's study date + x days Reason (from order): Referral Indication: Advanced Maternal Age Primigravida-659.5 time frame (1). STUDY INFORMATION Type of Report: 1st Tri Singleton IAC Accreditation Study • Numbers e.g. age at time of procedure. Procedure Performed (CPT): Diagnosis (ICD): • Text strings e.g. time frame in weeks and days. Time Obtained (hh:mm) Critical Results First Image: Carry Forward Last Image: Addendum Reasons NEXT VISIT 1 Days until next visit 30 NextVisitDate 31-01-2023 CLINICAL STAFF ADDITIONAL REPORT RECIPIENTS/OTHER IMAGING PERSONNEL Referring Physician: Dr. Marcus Everett Send Report to: Diagnosing Physician: Dr. Frank Welby Primary Sonographer: MDB 32 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Using dates in calculations in Report Designer SIEMENS Healthineers Definition Library Editor To use dates in calculations, you need to create and define % Definition Library Editor - C:\Users\z004r2ak\OneDrive - Siemens Healthineers\03_Templates\05_VA41E Date template\DatesInCalculation\DatesInCalculation - O X File Edit the output in the Definition Library Editor. Definitions Date/Time Definition 2 This is needed since the measurement library does not Calc Type Cardiac Item Name Next TAVI follow up Calc Type Cardiac support date or text outcomes/result. Language English (United States Display Name Next TAVI follow up Data Palette Patient Contexts When this is done, create the calculation in the Measurement Allergies Usage Optional Category Contexts AllergiesID Name Stored in new_DateTimeDefinition_6_dt Next TAVI follow up Database Data Context Study Library Editor. CT Cardiac ]Carry Forward [ Include in Upload CT CardiacFunctional CT CaScore Attributes CT Vascular Custom Contexts Show 3 To create a calculation of the patient’s next visit date, for Department Info O Date Diagnosing Physician Info O Time example: DICOM Fields Fetal Info O Date and Time Misc Info O Duration MRI Patient • Open the Definition Library Editor. Patient Demographics Referring Physician Info • Select New Date/Time (1). Report Info Study Info Rename the Item Name to Next TAVI follow up, for Wall Scoring - Motion • Wall Scoring - Perfusion Wall Scoring - Thickening example (2). Wall Scoring - Viability • Select Date (3). Reference 1 Create ... Find: New Category New Checkbox New Context New Date/Time New Person Name New Text Box New Indirect Changes to a definition can affect all templates that use that definition. On the current template, the definition will have to be re-inserted. Hide 33 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Using dates in calculations in Report Designer SIEMENS Healthineers Measurement Library Editor Measurement Library Editor - C:\Users\z004r2ak\OneDrive - Siemens Healthineers\03_Templates\05_VA41E Date template\DatesinCalculation\DatesInCalcula ... O X • After that, create a new calculation in the Measurement File Edit View Library Editor (1). Measurements and Calcs Definition Calc Type Cardiac Item Name TAVI follow up Calc Available In Cardiac Language English (United States) Display Name TAVI follow up Calc 2 Category ACC v5 Select unitless in the Units field (2). The calculation must E ACC v5 Units unitless (ame Stored in Database TAVI_follow_up_Calc_c • age of device Usage Calculated have the unit of unitless, otherwise the output section days Data Context Study Fluoroscopy Time Disable Equation : TAVI follow up Calc [ Calculate out of range values Displayed Precision 2 will be disabled. Name the calculation, e.g. TAVI follow up Aorta Aortic Valve [ Carry Forward Include in Upload Calc. D. ASD CAPS Circle Add Input Remove Input Up Down 4 Coronary Arteries Inputs Alias Data Name Units Data Type |Min Max Doppler Select the Add Output tab in the Output section (3) and study Study Date unitless • @ Ductus days days days mean @ ECG select the definition you created in the Definition Library ₼ Epsilon A period "." must be used as a decimal separator in equations, e.g. 1.5 # Fetal Doppler Equation study + days Editor. Fetal Echo Fetal Info GE Great Veins # Hepatic Veins Create your calculation. In this example you need to add @ Left Atrium • # Left Ventricle Validate Equation OK Test Data Study Date and Days as input and define the equation, # Misc Info Available equation terms: -, ! =, (, ), *, /, +, <, <= ==, > > =, abs(), acos(), and, asin(), atan(), cos(), ₼ Mitral Valve ctxcount(), ctxmax(), ctxmean(), ctxmin(), ctxsum(), datediff(), else, elseif, exists(), heartrate() isnot, MOD Disks ImsZScore, In(), log(), max(), mean(), min(), nonzerocount(), onecount(), or, pi, pow(), prior() study + date (4). 3 d, sin(), @ MRI Output Next TAVI follow up Add Output Remove Output Patient Demographics Patient Exam Info Allowed minimum and maximum of calculation: Create a graph for # Pericardium Min: unitless Max: unitless this calculation Find: New Measurement 1 Reference New Calculation New Category Hide 34 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Using dates in calculations in Report Designer SIEMENS Healthineers • Then add the definition next TAVI Follow Up to the Physician Pt Calcs TEE LV RV LA IAS RA AOV MV TV PV Ao/PA Pericrd Other Summary CARDIOVASCULAR MEDICAL CENTER report (1). SIEMENS PATIENT AND STUDY INFORMATION Past Medical History/Events A 1234 Arbor Drive Message Center (these comments are not shown on report) Healthineers Ann Arbor, MI 48106 1 (888) 795-4639 2 Patient Demographics Information Discrepancy Checker Pt. Name: Jamie Elfman Study Date: 01-01-2023 Prefix First M Last Suffix This definition needs Study Date (2) and Days (3) added Birth Date: Patient MRN: 9998768 Pt. Name: Jamie Elfman • Patient Age Accession Number: Pt. Gender F MRN: 9998788 Admission ID to the report and/or worksheet to calculate the next visit Pt. Height 69,0 in (175.3 cm) BSA (Dubois): 1,80 m2 Accession Custom Field 1: Pt: Weight 145.0 lb (65,8 kg) Blood Pressure 120/80 mmHg Admission ID: Custom Field 2; date. Primary Sonographer. Jamesc 1 Admission status: Ht 175 cm 69 in TAVI Follow Up: 31-01-2023 Date of Birth: Age: Wt: 65,77 kg / 145 lb Gender: F SUMMARY BSA (DuBois): 1,80 m2 1. Estimated left ventricular ejection fraction is normal with an ejection fraction BP: 120 / 80 mmHg of 74 % by Simpson's biplane method of discs. Study Information ADDITIONAL STUDY INFORMATION • Now, you can display the patient's next visit. Study Date/Time: 01-01-2023 at 10:15:08 Carry Forward PHYSICIAN INTERPRETATION Study Type: Cardiac Image quality: AUC - TTE Left Ventricle: The estimated left ventricular ejection fraction is normal with an ejection fraction of 74 % by Simpson's Report Title: Accreditation Study:[ biplane method of discs. QUANTITATIVE DATA Procedure: Indications: Left Ventricle Measurements IVSd (2D) 0.9 cm LVPWd (20): Diagnosis: 1.0 cm LVIDd (20) 5.2 cm IVSs (20) 1.2 cm LVPWs (20) 1,4 cm LVIDs (20): 3,3 cm Comparison Teaching File Critical Results Addendum Reasons LV FS%: 37 % LV Vol d. MOD A2C 409.2 ml Staff/Report Recipients Additional Diagnosing Physician LV Vol d. MOD A4C 556.0 ml LV Vol d. MOD BP 487.5 ml Requesting Physician: LV Vol Index d, MOD A2C: 227,1 ml/m2 Interpreting Physician: LV Vol Index d. MOD A4C: 308.6 ml/m" LV Vol Index d. MOD BP: 270,5 ml/m2 Primary Sonographer: Jameson LV Vol's, MOD A2C 107,7 ml LV Vol s, MOD A4C 133,1 ml Follow Up 3 LV Vol s. MOD BP: 125.1 ml LV Vol Index s. MOD A2C: 59.8 ml/m2 LV Vol Index s. MOD A4C: 73,9 ml/m2 Next TAVI follow up 31-01-2023 - days 30 days LV Vol Index s. MOD BP: 69.5 ml/m2 LV EF MOD A2C: 74 % LV EF MOD A4C: 76 % 35 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E New MRI report and worksheet template 36 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 New MRI report and worksheet template SIEMENS Healthineers In collaboration with pediatric cardiologists from prominent Pt Exam Macros Situs/Veins/Atria Circle AV Valve Vent Semilunar & Art Peri & Extracar Message Center (these comments are not shown on the report) children’s hospitals, we have created an MRI template. It offers everything needed for the management of congenital heart disease Patient Information MRI reporting in both pediatric and adult patients. Pt. Name: Karen Youngchild Pt. ID: 554907.1091222471 Accession #: Ht: 137.16 cm 54.00 in Account #: The template incorporates IPCCC diagnostic codes (1) related to Wt: 40.82 kg 90.00 lb Custom 1: Custom 2: 2 BSA (Haycock): 1.25 m2 congenital heart disease, enabling easy data search when using the DOB Age: BSA (DuBois): 1.23 m2 Gender: F BSA (Mosteller) 1.25 m2 Data Mining tool. Study Information Study Quality & Information Study Location: Study Date/Time: 1/1/2015/ 4:21:11 PM We also added the Mosteller BSA (2). Study Type: Cardiac 1 Indications: Diagnosis (IPCCC): Carry Forward Critical Results Addendum Reasons Personnel Interpreting Physician: Referring Physician: cc: Report: cc: Report: Technologist: Jameson Fellow 1: Fellow 2: Post-Processor: Nurse: 37 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 New MRI report and worksheet template SIEMENS Healthineers Exams tab 1 In the Exams tab, you can fill out information about sedation, Pt Exam Macros Situs/Veins/Atria Circle AV Valve Vent Semilunar & Art Peri & Ext History History contrast, sequences, and more (1). Scanner Scanner Sedation Sedation Anxiolysis Anxiolytic Lorazepam M Dose Unit Route Medications The template is designed to support pediatric and adult 2 Contrast Dose Unit !Pt Exam Macros Situs/Veins/Atria |Circle AV Valve|Vent Semilunar & Art Peri & Ex Left Ventricle Set normal)(Comments Z-score Z-score congenital cardiologists with different reporting traditions, and Medication Dose Unit Route Value Index Buechel Olivieri Olivieri HR 75 bpm HR Meds EDV 186.81 ml 129.62 ml/m2 5.19 8.64 Buechel LV EF 47 % Other ESV 99.60 ml 69.11 ml/m2 5.63 11.92 AAo Fwd Flow GLS -16 % you can select either: SV 87.21 ml 60.51 ml/m2 1.98 2.65 5.80 ml GCS -2.40 % Sequences CO 6.55 l/min 4.54 l/min/m2 1.22 1.02 Survey Blac Black Blood Tissue Char Mass 86.50 g 60.02 g/m2 1.58 2.43 OSSFP 2D Spin Echo 2D PSIR Subpulmonic LV Black Blood 3D Spin Echo 2D PSIR 3D PSIR Size Max Max Wall O 2D bSSFP Angiography [3D PSIR Wall Thickness Septum Max LVPW Thickness 2D GRE 3D SSFP Function cm cm The Olivieri and the Buechel Z-scores (2). 3D bSSFP 0 3D GRE OSS LGE cm 3 • 3D GRE [ Time Resolved MRA [Native T1 Morph Single Ventricle Volumetry [Lymphangiography [] Post-gad Single Ventric []T2 Map !Pt Exam Macros Situs/Veins/Atria Circle AV Valve Vent Semilunar & Art Peri & [] Real-time Cine DCMRL [] Myocardi Bullseyes Situs Assessment set normal ) ( Comn. Phase Contrast The Van Praaghian and Andersonian systems (3). 2D [] Liver T2 LV Wall Situs Synopsis Left Isomerism MO Single Ventricle • [] Ferriscan Thickness y Wall Motion LGE 4D Cardiac Position First Pass []T1w Blac LVOT Cardiac Apex []T2w Blac Structure Atria Atria I M Looping Ventri ... M Arteries Arterie ... M Study Notes Obstruction Atrial Situs Atrioventricular Alignment/Connections Study Notes Right Ventricle Ventriculoarterial Alignment/Connections Z-score Z-score Value Index Buechel Olivieri Oolivi Ventricular Looping/Topology Post-Processing EDV 90.00 ml 62.45 ml/m2 -2.81 -4.18 D Bued Ventricular Position Spleen Software ESV 35.00 ml 24.29 ml/m2 -2.49 -3.36 -3.36 Conal Position Liver Circle SV 55.00 ml 38.16 ml/m2 -2.05 0.27 0.27 AV Position to PV Stomach NeoSOFT co 4.13 l/min 4.54 l/min/m2 39.83 -8.04 Abd Venous Bronchi -8.04 0000 Mass g a/m2 XXXX Systemic and Pulmonary Veins set normal Comments Size M Wall Mo Stent Vessel Normality Connection Obstruction Wall Thickness Function Delayed Er RVOT Systemic Veins Normal Structure Obstruction Innom/Brachiocephalic IVC Coronary Sinus Catheter/Lead Ventricular Septum Hepatic Veins Puim Veins Septal Position VSD Right and Left Atrium set normal ) ( Comments RA LA Value Index Appendages RA 4Ch Length cm cm/m2 ASD/PFO RA 4Ch Area cm2 cm2/m2 Shunt Direction RA 4Ch Volume mi/m2 Qp/Qs LA 4Ch Length cm cm/m2 LA 2Ch Length cm cm/m2 Qp/Qs LA 4Ch Area cmz cm2/m2 LA 2Ch Area cm2 cm2/m2 LA Vol AL ml/m2 LA Vol BP MOD ml/m2 38 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 New MRI report and worksheet template SIEMENS Healthineers Macro tab The Macro tab is designed to provide 90% of the 1 HLHS Pre-op (Native) Anatomy AoV Regurg % ml essential information needed to generate a report based ASD/PFO Shunt Direction on the diagnosis or condition. For example, with the Native Diam 1 (cm) Diam 2 AOV Anatomy MPA Prox AoV Leaflets condition of Single Ventricular, you are provided with: MPA Distal AoV Stenosis 2 RPA Proy Glenn [Com AoV Regurg RPI Glenn Ao Root LPA Right SVC Left SVC • Pre-op tab (1) Asc Ad LPA Right Glenn Left Glenn Trans Arch Neo and Native RPA Neo and Native LPA • Glenn/Fontan (2) sthmus Diam 1 Diam 2 Diam 1 | Diam 2 Prox Desc Ao cm cm cm Post-op (3) RSVC Prox LSVC Drav 3 Stage 1 Post-op • Pulmonary Arteries RSVC Mid RSVC Anast LS Anatomy Shone Complex MO Single Ventricle Volumetry Stent Vesse Normality Loca Stage 1 Procedures Morphology Neo RPA Neo Contour Method RPA Distal (lateral to Glenn) LAOV Anatomy Native Diam 1 Diam 2 Diam 3 These tabs contain all the necessary details, many of Central Confluence LE AOV Leaflets (cm) (cm) (cm) (bilateral BDG) Native Ao Root AoV Stenosis Neo Ao Root which are found elsewhere in the worksheet. They are Fontan AoV Regurg Native Asc Ao Ao Root Fontan Neo Asc Ao Fontan Conduit Asc Ao e Trans Arch gathered in one place for better report creation for Fenestration Trans Arch Isthmus Shunt and Duct Isthmus Prox Desc Ao complex anomalies. BTT Shunt PDA Prox Desc Ao Aortopulmonary Collaterals Diam Diam 2 DKS (cm) (cm) Origin Insertion Desc BTT Shunt RPA Prox RPA Distal Sano Conduit LPA Prox PDA LPA Distal Venovenous Collaterals Stent Vessel Normality Location Size Obstruction | Shunt Origin Insertion Desc neo aortic valve regurg % Native aov regurg % 39 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 New MRI report and worksheet template SIEMENS Healthineers LV tissue In this MRI template, you get multiple bullseyes for LGE set normal ) ( Comme 1 evaluating LV tissue: 2 Appearance Diffuse M Method Mycardial LGE % of % TO 2 Mass LV Wall Thickness LGE Mass myocardium Summary • 64.00 g/m2 1 66.00 g/m2 103.12 • LV Wall Motion 1 LGE Contrast filling (1) 1 • Comment 1 • T2w When you fill out the bullseye, a text is automatically put on OTo Report subendocard subepicardia the report side (2). 0 No Score 1 generic 2 ial 3 mid-wall 4 5 transmural 2 Summary 1. Left ventricle: Entire septum and entire anterior wall are abnormal. Left Ventricle The entire septum shows mid-wall late gadolinium enhancement. The entire anterior wall shows subendocardial late gadolinium enhancement. All remaining segments show no areas of late gadolinium enhancement. 40 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 New MRI report and worksheet template SIEMENS Healthineers As always in our templates, you can add or Pulm Flows Qp/Q Full Data Display remove measurements to make the report and 2D 4D worksheet fit your department’s needs. Rev Rev Net Rev Net Flow Flow Net Flow Rev Flow Net Flow ml/be I/min Flow I/min |Regu Flow I/min/ Flow I/min/ Regur at /m2 ml/beat /m2 rg % |ml/beat m2 ml/beat m2 0 % Ascending Ao Fwd Fwd Rev Net FWI Measurements from sources such as Circle will Prox Desc Ao Flow Fwd Flow Rev Rev Flow Net Net Flow Fwd Fwd Flos ml/b Flow l/min/ Flow Flow l/min Flow Flow I/min/ Regurg Pk Vel Flow Flow 1/mil MPA 2.00 0.13 3.00 0.19 40.00 HR eat I/min m2 ml/beat I/min /m2 ml/beat l/min m2 % m/s HR ml/beat I/min m2 automatically populate the worksheet. Sequence 20 2D 2D 2D 2D 2D 2D 2D 2D 2D 2D 4D 4D 4D 4D LPA Ascending Ao RPA Prox Desc Ao SVC (Right) bd Ao SVC (Left) SVC (Right) SVC (Left) IVC IVC MV MPA 80 5.00 0.40 0.32 2.00 0.16 0.13 3.00 0.24 0.19 40.00 TV RPA LPA PDA RUPV RUPV RMPV RLPV RLPV R Common PV R Common PV LUPV LUPV MPV LLPV LLPV L Common PV _ Common PV PDA Fontan Below ... Fontan Below F. Fontan Above. Fontan Above F. Fenestration Fenestration MV TV Fwd Fwd Flow Rev Rev Flow Net Net Flow Flow Flow I/min/ Flow Flow I/min/ Flow Flow I/min/ Label HR Regurg Pk Vel ml/beat l/min m2 ml/beat I/min m2 ml/beat l/min m2 % m/s 41 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E Language support 42 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Language support SIEMENS Healthineers syngo Dynamics has been translated into multiple languages to support our global user base. syngo Dynamics® • In VA41E, French is supported for the user interface and Login reporting language. Password Greek is now supported for reporting. Department AdultEcho / SDXSERVER • Login English English This application Deutsch wing/reading. Español Svenska Please note: Report Designer can be installed selecting the Dansk Greek language and reports and worksheets can be created in Français Greek, the units are supported in Greek as well. However, the UI will be in English. Please contact Siemens Healthineers Service for more information. 43 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers syngo Dynamics VA41E Support and compatibility update 44 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Support and compatibility update SIEMENS Healthineers In VA41E, the newly supported system and compatibility updates are as follows: System Version Microsoft Operating System Windows 11 PieCAAS 8.5.5 syngo.via VB80 CVI 42 6.0.x Sensis VD15C Please note: Previously supported versions are maintained. 45 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com 46 Effective Date: 22 Oct 2024 | QR700014635 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024
- va41e
- dynamics new
- caridac va41e