
syngo CT VB10 Scan&GO Improvements Job Aid
You will learn about the Scan&GO improvements in this PDF as available with the syngo CT VB10 software update.
Product relevance: SOMATOM go.Now, SOMATOM go.Up, SOMATOM go.All, SOMATOM go.Top, SOMATOM X.cite, SOMATOM X.ceed, NAEOTOM Alpha.
Target group: Basic user, all users.
Recommended to be viewed on the following devices: All (incl. tablet, smartphone).
SIEMENS Healthineers syngo CT VB10 Scan&GO Improvements Job Aid Template Effective Date: 10 Aug 2021 | HILS 2223 Job Aid Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 Table of contents SIEMENS Healthineers Home screen 3 Access bar 4 New Privacy tab 5 New Refresh button 6 Support for different patient positions 7 Gantry tilt on tablet 8 New button Window Preset 9 Set ROI in bolus tracking procedure on tablet 10 Test bolus on the tablet 11 Blinking Press MOVE button 12 Apple clock 13 2 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 Home screen SIEMENS Healthineers 1 SIEMENS CT Scan&GO Healthineers. ..... SIEMENS . 1 New Live indicator: rs Healthineers . 2 This indicates whether the tablet is connected to the gantry or not. 2 New Home button: Tap the Home icon to go back to the home screen during the examination. CH Scheduler Examination VA40 VB10 3 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 Access bar SIEMENS Healthineers 1 New Scheduler button: VA40 Tap the Scheduler icon to switch patients by closing SIEMENS Healthineers Test, VA40 08/03/1968 the current one. Start a new examination through the Patient Selection screen. VB10 2 SIEMENS × The number showing how many tablets are connected Healthineers EQ Test, VB10 08/03/1968 has been moved to Settings. 1 SIEMENS × Healthineers EQ Test, VB10 08/03/1968 Settings Connected Tablets: 1 X 2 Genera Privacy Radiotherapy Intervention About Moodlight On/Off 4 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 New Privacy tab SIEMENS Healthineers New Privacy tab in Settings: CT Scan&GO X SIEMENS . EQ Test, VB10 X Healthineers 08/03/1968 The Privacy tab allows you to hide or show the patient Settings Connected Tablets: [1] × image or patient information during the scan. General Privacy Radiotherapy Intervention About Hide Patient Name in Tab Hide Patient Image Hide Patient Information after Last Scan 000 -750.0 o SettinBack activate dowsGO 5 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 New Refresh button SIEMENS Healthineers New Refresh button in Scheduler: @ CT Scan&GO X SIEMENS. Test, VB10 × Healthineers 08/03/1968 Click the Refresh button. You update the patient list based on your sorting criteria. Q Search by Name, ID, DoB, Description, Procedure Date, Acc No. and Modality Today, Scheduled (1) C Test, VB10 *8/3/68, 12345 15:34 8/3/23 Emergency Patient Register Patient Patient Details -750.0 GO 6 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 Support for different patient positions SIEMENS Healthineers The tablet now supports different patient positions within one exam study. SIEMENS Test, VB10 X Healthineers' 08/03/1968 Thorax [factory] (Adult) / Feet First - Supine First topo with head first Second topo with feet first Patient Orientation Feet First Supine C+ Table Movement Out L 3.3s 3.9s 3.1s 4s Topogram Length [mm] 5.3 5.3 5.3 5.3 512 10 10 O O O Audio Control Instruction Language English Audio Visual = - 872.0 MM Cancel GO 7 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 Gantry tilt on tablet SIEMENS Healthineers It is now possible to set the range tilt on a topogram on the CT Scan&GO X SIEMENS. Test, VB10 X tablet. Healthineers 08/03/1968 Brain [factory] (Adult) / Head First - Supine Eff. MAS 310 KV 120 Exposure Time [s] CTDIvol [mGy] SSDE [mGy] Use the one-finger gesture to tap and drag the Range Tilt 7.29 (16cm)56.5 (9.9cm)69.4 DLP [mGy*cm] 789 Test, VB10 H icon. 12345 SOMATOM X.ceed ^08/03/1968, 55Y syngo CT VB10A 08/04/2023 HFS 12:22:40.96 PM TOP 101 1 IMA 1 TP-750.0 10cm kV Sn140 MA 55 TI 2.04 550.72 010 Simulator ilter Sn 2 s 2 s 7.7 5 Topogram Non-Contrast Brain - - 1006.0 Back GO 8 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 New button Window Presets SIEMENS Healthineers By clicking this Window Presets icon, you can switch between CT Scan&GO X SIEMENS . Acevedo, Lucio X the three window presets below: Healthineers 11/19/1943 Thorax [factory] (Adult) / Head First - Supine Eff. MAS 68 kV 120 Exposure Time [s] CTDivol [mGy] SSDE [mGy] DLP [mGy*cm] • Soft tissue 1.82 (32cm)10.1 (11.9cm) 15.4 262 Acevedo, Lucio • Bone 31f6c62a-ffe8-4fe4-a09d-534b1cb53693 SOMATOM X.ceed *11/19/1943, M, 79Y syngo CT VB10A 09/21/2023 HFS • Lung 12:01:44.29 PM RTD 201 102 IMA 34 TP -1,132.7 R kV 120 Elt. mAs 78 Quality ref. mAS 72 TI 0.25 F GT 0.0 SL 4.0/64x0.6/p1.2 500.0 0/0 1200 Simulator -600 3.3 s 5.3 s 3.9 s Topogram Thorax - - 1394.0 Close Recon 9 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 Set ROI in bolus tracking procedure on tablet SIEMENS Healthineers After a pre-monitoring scan, manually place the ROI on the CT Scan&GO SIEMENS X tablet if automatic detection is not activated. Healthineers Test, VB10 08/03/1968 Thorax [factory] (Adult) / Head First - Supine Eff. mÁs KV 100 Exposure Time [s] CTDIvol [mGy] SSDE [mGy] DLP [mGy*cm] 1. On the pre-monitoring image, tap inside a vessel. The 26 0.25 (32cm)1.39 (12.8cm)2.15 1.39 ROI is placed. The color of the ROI corresponds to the Test, VB10 A 12345 SOMATOM X.ceed *08/03/1968, 55Y syngo CT VB 10A HFS 08/04/2023 color of the diagnostic range. 3:41:18.03 PM MON 201 2 IMA 1 TP -1,111.0 2. Optional: To enlarge or reduce the ROI, tap and drag the edge of the ROI. kV 100 Eff. mAs 28 Quality ref. MAS 30 TI 0.25 F GT 0.0 SL 10.0/1x10.0 300.0 0/0 400 Simulator 4.6 s 2 s 0.3 s 10 s 0.8 5 3.9 5 Topogram Premonitoring Monitoring Thorax = - 1111.0 Back GO 10 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 Test bolus on the tablet SIEMENS Healthineers In VB10, you can now complete the entire examination workflow containing the test bolus on the tablet. 1 Perform the Test Bolus scan. 2 Display the Test Bolus online images, set the ROI on the Test Bolus image. 3 The enhancement curve is displayed, the time-to-peak is automatically added to the delay time of the diagnostic scan range. CT Scan&GO x CT Scan&GO CT Scan&GO SIEMENS Test, VB10 SIEMENS Test, VB10 X SIEMENS . Test, VB10 X Healthineers 08/03/1968 1 Healthineers 08/03/1968 2 Healthineers A LQ 08/03/1968 3 Thorax TestBolus (Adult) Head First - Supine Thorax TestBolus (Adult) / Head First - Supine Thorax TestBolus (Adult) / Head First - Supine Eff. MAS KV Exposure Time [s] 22 100 CIDIvol [mGy] SSDE [mGy] Exposure Time [s] SSDE [mGy] SSDE [mGy] 15.00 (32cm)11.2 DLP [mGy*cm) Eff. mAs KV CTDIvol [mGy] DLP [mGy*cm] Eff. mAs Exposure Time [s] CTDIvol [mGy] (12.5cm)26.2 11.2 DLP [mGy*cm] 22 100 KV 12.00 (32cm) 15.5 (12.5cm)23.3 15.5 22 100 12.00 (32cm)15.5 (12.5cm)23.3 15.5 Test, VB10 SOMATOM X. cood Test, VB10 12345 Test Bolus Scan 12345 SOMATOM X.ceed Test, VB10 12345 SOMATOM X.ceed *08/03/1968, 55Y syngo CT VB 10A HFS *08/03/1968, 55Y syngo CT VB10A HFS *08/03/1968, 55Y syngo CT VB10A 08/04/2023 08/04/2023 08/04/2023 HFS 10:38:14.52 PM 10:39:34.36 PM 10:39:34.36 PM TOP 101 SEQ 212 SEQ 212 1 IMA 1 2 IMA 12 2 IMA 12 TP-750.0 TP -1,093.5 TP -1,093.5 5 s kV 100 kV 100 Eff. mAs 25 Eff. mAs 25 Quality ref. mAs 27 Quality ref. mAs 27 MA 55 TI 332 A TI 1.0 GT 0.0 GT 0.0 SL 10.0/1x10.0 SL 10.0/1x10.0 550.72 0/0 Delay time 358 300.0-8/0 300.0 -8/0 Simulator Simulator Simulator nx 50 150- 120 95 90 60 30 15 20 25 20 25 15 20 25 3.3 s 5 s 22 s 3.9 5 3.3 s 8 5 17.5 s 5.3 s 3.9 s 3.3 s 8 s 17.5 16 s 3.9 s Topogram Test Bolus Thorax Topogram Test Bolus Set ROI in Test Bolus image. Topogram est Bolus Thorax - - 1093.5 MM Cancel GO = - 1093.5 MM Back GO - - 1093.5 MM Back GO 11 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 Blinking Press MOVE button SIEMENS Healthineers When the system requests a table movement action, the Press MOVE button on the tablet blinks. -1093.5 ww Press MOVE Cancel GO -1093.5 ww Press MOVE Cancel GO 12 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 Apple Clock SIEMENS Healthineers • Close Scan&GO to access the Apple Clock app. • You can use it, for example, to time the manual injection of contrast medium. 11 12 10 2 9 3 8 4 7 5 Clock 13 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthineers AG 2023 Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim, Germany Telephone: +49 9191 18-0 siemens-healthineers.com 14 Effective Date: 01 Dec 2023 | QR700001716 Unrestricted © Siemens Healthineers AG, 2023
- ct
- somaris
- 10
- vb10
- scan
- go
- improve
- enhance
- delta
- somatom
- go
- now
- up
- all
- top
- exceed
- excite
- x.ceed
- x.cite
- naeotom
- neotom
- neatom
- alpha