
syngo CT VB10 myNeedle Companion Improvements Job Aid
You will learn about the myNeedle Companion improvements in this PDF as available with the syngo CT VB10 software update.
Product relevance: SOMATOM go.Now, SOMATOM go.Up, SOMATOM go.All, SOMATOM go.Top, SOMATOM X.cite, SOMATOM X.ceed, NAEOTOM Alpha.
Target group: Basic user, all users.
Recommended to be viewed on the following devices: All (incl. tablet, smartphone).
SIEMENS Healthineers syngo CT VB10 myNeedle Companion Improvements Job Aid Template Effective Date: 10 Aug 2021| HILS 2223 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG I © Siemens Healthineers, 2024 Table of contents SIEMENS Healthineers New protocols 3 SIEMENS Healthineers Topogram in intervention application 4 HandCARE for i-Sequence* 7 Autoload of next scan when switching between modes 8 Automatic loading of non-i-ranges into myNeedle Guide 9 Append different protocols with different patient positions 12 Cancel MOVE button on the tablet 13 In-plane view on the tablet 14 myNeedle Detection* 15 Miscellaneous 24 2 Effective Date: 16 May 2024 | QR700007713 * Optional feature. Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 New protocols SIEMENS Healthineers One new protocol added in VB10 for Protocol: Extremity Intervention 3D [factory] adults. Protocol Description -Indications: biopsy, abscess in the extremity, w/ Topogram wo CM i-Spiral Extremity Examination Information • Extremity Intervention 3D -Scan Modes: InterventionSpiralAdultExtremitiesSn, [factory] InterventionSequenceAdultExtremitiesSn, InterventionFluoroAdultExtremitiesSn2d 3 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Topogram in intervention application (1) SIEMENS Healthineers Test Intervention-1 SOMATOM X ceed 3333 syngo CT VB 10A Topogram 0.60 Tr20 cor *03/30/1990 CT 03/30/2023 The topogram will be automatically loaded into automatically 11:35:16 AM TP -1375.0 1 the Reference 1 segment. This applies to all layouts with at least one Ref segment. R Reference 1 10 cm If you don’t need the topogram functionality, you can use the Reference 1 segment as a regular A reference segment as in VA40. Just load any other GTO 350 dataset into the segment and it will replace the Test Intervention-1 H SOMATOM X.ceed 3333 Topogram 0,60 Tr20 cor syngo CT VB10A HFS topogram. Afterwards the topogram can be Open *03/30/1990 CT 03/30/2023 View as Read-Only 11:35:16 AM TP -1375.0 loaded again, as shown below. Planning TI Open with manually View as Read-Only with Load into myNeedle Guide Set Delete Protection state Reference 2 Set Archive state R If needed, you can also load the topogram Correct 10 cm manually in the Reference 2 segment. x Cut Copy @ Paste A Delete Del Manage Raw Data vention 1 H SOMATO n 0.60 Tr20 cor 990 A Interventions MPR Thin 23 AM The line and the box will NOT be visible when clicking into the MPR segments. 5 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Topogram in intervention application (3) SIEMENS Healthineers In the exam UI (left screen), there is an identical functionality. However, they are not synchronized. The topogram in myNeedle Guide (right screen) only visualizes the position of the currently loaded series. It does not display scan or recon range for the next control scan. Abdomen Intervent ... 3391 BOMHATCH % rezd smgo CHLE 10A Recon Ranges myNeedle laser 03 13012:23 02/30/2023 11:35: 083% " 11:43:36.437H Topoyieri ingrese Noele N3 Topogram TEF 0 EEQ 303 TP -13:60 LEN 158 11 1418 GONATON LOW SONATOM X ESPS TR-1,454.5 3)1100 CT YB124 1-Spiral Abdoras 5 CO Br40 FFFF HPS FREE i-Spiral Abdomen GT Ct CT i-Sequence Abdomen 1- Spiml Abdomen 11.93 50 AM TP 14:11 TP 14F09 11.35.78 AM Precondition I-Spiral Abdomen ..................................... .................................................................. Sequence Abdomen iSeaLerice i-Spiral Abdomen C6 M F SICH 35 x 5.0 + 30 Espnsure time 5.57 % STDIval (32 cm) 2.01 may Girder Fixit SSDE (23 cm) 3.73 mGy 511190 CY VB114 3339 TactirisverEct DUP 1-Spiral Abdort EFFE Reconstruction CT. 1.52:58 AM 11.59.55 AN 11.35.35 AM 6T00 EL 5012E DE59 0 4 TE05- 13. 0:030CH: CU STA F bs En 350.0 DID Er40dun13. 014:4 0-b E/ohn Activate I-Spiral Abdomen scan Cur.Erm GO Carizel TO Activate Windows 2.85 4.2. 4.25 Go to Settings to activate Windows 5.3 O O Left monitor: Prospective planning of the next scan/recon. Right monitor: Visualization of the (most recent) control scan. 6 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 HandCARE for i-Sequence* SIEMENS Healthineers In addition to i-Fluoro, HandCARE is now also available Precondition for i-Sequence. i-Sequence Abdomen (1) (2) (3) i-Spiral i-Sequence i-Fluoro Eff. mAs 43 10 O'clock 12 O'Clock 2 O'clock None kV 120 Off Slice 7 × 5.0 + 3D The scan mode icon is updated accordingly: mm 10 O'Clock 12 O'Clock 2 O'clock None HandCARE off O O Exposure Time off S Last/Next 10 o'clock There are no start delays for the i-Sequence scanning CTDIvol 12 o'clock 2 o'clock mGy when using HandCARE. DLP 11.0 mGy*cm 7 Effective Date: 16 May 2024 | QR700007713 * It is optional for upgrade systems. Please order this license via the O&U price book. Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Autoload of next scan when switching between modes SIEMENS Healthineers In VA40, it was necessary to press GO when switching to i-Spiral / i-Sequence / i-Fluoro. i-Spiral Abdomen Confirm GO Cancel ¡-Spiral i-Sequence i-Fluoro In VB10, this step is no longer necessary. Whenever you switch between i-ranges scan modes, the Start button is immediately available. Eff. MAS 608 Also, when all scans of an i-range were performed (for example, 1 i-Spiral kV 70 scan, or 50 3D i-Sequence scans, or 100 2D i-Sequence scans) the range is repeated and loaded automatically. Slice 35 x 5.0 + 3D mm Exposure Time 3.52 s Now you can also change scan parameters and the mode stays loaded. CTDIvol (32 cm) 7.89 mGy Exception: If you change the scan range via the graphic range planning box SSDE (22 cm) 16.0 mGy in the topogram, the range is unloaded, and you must click GO again. DLP 163 mGy*cm Press START 8 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Automatic loading (recon) of non-i-ranges into myNeedle Guide SIEMENS Healthineers For myNeedle Guide 2D, the new VB10 factory protocols will be preconfigured. The diagnostic planning spiral is then loaded automatically into the myNeedle Guide application. Open View as Read-Only Planning TI Even with myNeedle Guide 3D license, some users want to use diagnostic Open with View as Read-Only with ranges (also with contrast media) for needle path planning. In VA40, you need Load into myNeedle Guide to load these series manually. Now, non-i-ranges, e.g., regular diagnostic Set Delete Protection state spirals can be loaded into myNeedle Guide automatically. Set Archive state Correct This can be configured in the Recon / Auto Tasking tab card. (Next slide) x Cut E Copy However, if your system with myNeedle Guide 2D has been upgraded to VB10, Paste Delete Del you need to set the parameters in your protocols accordingly to enable Manage Raw Data automatic loading. The same applies for myNeedle Guide 3D users: If you have a custom-built intervention protocol, which includes a diagnostic scan for planning, you need to reconstruct these recons before. 9 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Automatic loading of non-i-ranges into myNeedle Guide – SIEMENS Healthineers Recon tab card (1) For all diagnostic scans inside a CT Interventions protocol axial Ref 1 (= contains an i-range) there is a new entry for myNeedle Guide: MPR Ref 2 • Auto Tasking / Advanced Visualization: Select myNeedle Guide. X Recon Favorites General Recon Recon&GO Image Impression | Recon Box Physio Recon Auto Tasking Inline Options - - Scan/Recon Examined Transfer Nodes Auto CT View&GO CT View&GO Dataroles Auto Printing Advanced Visualization Advanced Visualization Dataroles Local Application Workflow • Arterial Phase Abdomen 5.00 Br40 A3 cor omen Off None Off myNeedle Guide Axial Arterial Phase Abdomen 5.00 Br40 A3 ax Off None Off None Axial None MPR Ref1 Ref2 • Auto Tasking / Advanced Visualization Dataroles: Select in which segment type the scan will be displayed. X Recon Favorites General Recon Recon&GO | Image Impression | Recon Box Physio Recon Auto Tasking Inline Options - - Scan/Recon Examined Transfer Nodes Auto CT View&GO CT View&GO Dataroles Auto Printing Advanced Visualization Advanced Visualization Dataroles Local Application Workflow Arterial Phase Abdomen 5.00 Br40 A3 cor Off None Off myNeedle Guide Axial Arterial Phase Abdomen 5.00 Br40 A3 sag omen Off None Off myNeedle Guide MPR None Arterial Phase Abdomen 5.00 Br40 A3 ax Off None Off myNeedle Guide Ref1 10 This is also possible for multi orientation recons. Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Automatic loading of non-i-ranges into myNeedle Guide – SIEMENS Healthineers Recon tab card (2) Hint: The columns Advanced Visualization and Advanced Visualization Dataroles only appear if as part of an intervention protocol (= contains one i-range) an intervention scan mode is appended. • Advanced Visualization / Advanced Visualization Dataroles: Only visible if in Intervention protocol (contains i- range: X Recon Favorites General Recon Recon&GO | Image Impression | Recon Box Physio Recon Auto Tasking Inline Options - - - Scan/Recon Examined Transfer Nodes Auto CT View&GO CT View&GO Dataroles Auto Printing Advanced Visualization Advanced Visualization Dataroles Local Application Workflow Arterial Phase Abdomen 5.00 Br40 A3 cor Off None Off myNeedle Guide Axia Arterial Phase Abdomen 5.00 Br40 A3 ax omen Off None Off None Axial None MPR • Ref1 Ref2 • Non-Intervention protocols (do not contain i-ranges): Advanced Visualization / Advanced Visualization Dataroles are not available. x Recon Favorites General Recon Recon&GO | Image Impression | Recon Box Physio Recon Auto Tasking Inline Options - Scan/Recon uto Recon Ref. Lines Requested Body Part Examined Transfer Nodes Auto CT View&GO CT View&GO Auto Local Application con Procedure Dataroles Printing Workflow Abdomen 5.00 Br40 A3 cor None Abdomen 5.00 Br40 A3 ax On Off Abdomen Off Off Off Off None Off None 11 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Append different protocols with different patient positions SIEMENS Healthineers With VB10, the tablet workflow now supports changing the patient SIEMENS Healthineers Maldonado, Vern 07/31/1938 position during the study. Also, when a protocol with a different default patient position is appended. Abdomen Multi Phase [factory] (Adult) Head First - Supine Patient Orientation Head First Supine This is also important when appending protocols with different default C Table Movement 5 patient positions. It makes the tablet workflow more robust in this Topogram Length [mm] 512 regard. Audio Control Instruction Language Abdomen [factory] ... English myNeedle Laser Audio Visuals myExam Compass Please still read the Topogram disclaimer carefully! Abdomen Patient position Patient Position × Keep in mind that HF supine HF prone HF right HF left ? Selected patient position is identical to the patient you need to press position in the previous scans. Do you want to use Identical Patient Position Selected the previous planning image? If yes, press Cancel in the Execution control. Cancel in the most The selected patient position is identical to the patient If no, press Confirm in the Execution control. position in the previous scans. FF supine FF prone FF right FF left common case, if the To use the previous planning image, press "Cancel" i-Spiral Abdomen To use a new planning image, press "GO" OK patient position is Reconstruction = - 750.0 Cancel GO Close kept. 12 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Cancel MOVE button on the tablet SIEMENS Healthineers SIEMENS Healthineers ... EO Intervention 6 X 03/30/1979 If you need to cancel a movement for the next intervention scan, the CTDIvol [mGy] SSDE [mGy] DLP Cancel MOVE button is now also available on the tablet. (32 cm) 7.89 (22 cm) [mGy*cm] 16.0 163 Accum. [mGy] 0.00 @ 0.0 mm Accum. [mGy*cm] 0.00 i-Spiral This is relevant if the user wants to freely position the patient table for the one scan of an i-Sequence or i-Fluoro range. Console: Tablet: Table Position x Position -1,391.0 mm Height 89.5 mm Tilt Confirm or skip Step O Cancel MOVE Define Path Progress Needle Confirm OK Cancel Needle n/a -1846.0 Press MOVE Cancel MOVE GO 13 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 In-plane view on the tablet SIEMENS Healthineers ..... SIEMENS EO X test 03/30/2000 The Progress Needle step on the tablet now contains a new icon. Healthineers CTDIvol mGy] SSDE [mGy] DLP [mGy*cm] (32 cm) 2.25 (- cm) 42.3 You can activate different views via this icon: • In-Plane • Ortho • Needle Detection (if myNeedle Detection is switched on) lip = Needle Detection Progress Ne Ortho Needle Detection In-Plane < 3 Define Path Progress Ne Ortho Needle N1 In-Plane -- - 1371.5 Press MOVE Cancel MOVE GO 14 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 myNeedle Detection* (1) – Introduction SIEMENS Healthineers After a control scan, you typically need to scroll to the needle tip (axial thick slice segments) and align the MPR planes with the physical needle in the images of the recent scan. This is quite tedious, and you must repeat / adjust this potentially after every new control scan. In VB10, this is now automated. It should take fewer interactions with the system, potentially saving time, and allow a better focus on patient and needle. The needle is detected automatically. The system automatically navigates in both the axial thick slice segments and in the MPR segments to show the needle in the best possible way. N1 The direction of the needle and the remaining path is visualized by a new, petrol-colored graphics object. The corresponding planned path is also shown in the image and the deviation of the current needle direction from the planned path is visible. 15 Effective Date: 16 May 2024 | QR700007713 * Optional feature. Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 myNeedle Detection* (2) SIEMENS Healthineers By activating the button, the system will search in the image auto 2 for a suitable needle, which matches the currently selected Progress Needle Position the needle using myNeedle Laser. Progress needle. Acquire N1 myNeedle Guide image data to check the needle position. 3 "active" needle path. Intervention 6 SOMATOM X ceed syngo CT VB10A Intervention 6 SOMATOM X ceed SOMATOM X ceed 12345 12345 syngo CT VB10A Intervention 6 SOMATOM X.ceed Intervention 6 12345 syngo CT VB10A 12345 syngo CT VB10A i-Spiral Abdomen 5.00 Br40 *03/30/1979 i-Spiral Abdomen 5.00 Br40 i-Spiral Abdomen 5.00 Br40 HFS *03/30/1979 Topogram 0.60 Tr20 cor The algorithm basically searches CT CT *03/30/1979 *03/30/1979 CT CT 03/30/2023 12:59:23 PM 03/30/2023 03/30/2023 12:59:23 PM 12:59:23 PM 03/30/2023 TP -1602.2 TP -1611.8 12:45:37 PM 18 TP -1607.0 19 20 TP -1475.5 in the vicinity of the selected planned needle path in the scan. R The selected needle is active. E E Interventions Head Intervention> GT O Center GT-O LA PL 35 mm the drop-down. NT 35 mm N1 5 cm 5 cm 5 cm IF MPR Thin Smerventions IsIntervention> MPR Thin MPR Thin 1500 16 Effective Date: 16 May 2024 | QR700007713 * Optional feature. Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 myNeedle Detection* (3) – Different display settings SIEMENS Healthineers There are two different visualizations of the detected needle: The regular 1 2 AFR AFR display (petrol arrow), which is identical to the planned path object (1), and the scale visualization, which can be configured (2). Important: The scale visualization is only displayed in the plane of the detected needle. In other planes the projection is displayed as a dotted line. myNeedle Guide myNeedle Guide Needle Detection Needle Detection Automatic needle detection active by default Automatic needle detection active by default Automatically apply Needle Detection view after automatic needle detection Automatically apply Needle Detection view after automatic needle detection Show scale for detected needle Show scale for detected needle 17 Effective Date: 16 May 2024 | QR700007713 * Optional feature. Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 myNeedle Detection* (4) – Scale for the detected needle SIEMENS Healthineers If enabled in the configurations and if the auto needle detect button is activated, a scale will auto 2 be displayed in front of the detected needle tip. Configuration: Show scale for detected needle The user can directly tell at what distance certain structures lie in front of the needle tip. For example: In around 2.5 cm the needle will enter the liver, no need to use the Distance Line tool. > 3D orientation line Detected 0.5 1.0 1.5 2.0 2.5 cm… needle tip Expected target point (can be at N1 different positions depending on the calculated distance). 18 Effective Date: 16 May 2024 | QR700007713 * Optional feature. Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 myNeedle Detection* (5) – Needle detection view SIEMENS Healthineers If myNeedle Detection is enabled, you can switch to the needle detection view. auto 2 Intervention 6 SOMATOM X ceed Intervention 6 SOMATOM X.ceed Intervention 6 12345 Axial thick slice i-Spiral Abdomen 5.00 Br40 syngo CT VB10A SOMATOM X ceed 12345 syngo CT VB10A 12345 syngo CT VB10A HFS HFS HFS *03/30/1979 i-Spiral Abdomen 5.00 Br40 i-Spiral Abdomen 5.00 Br40 *03/30/1979 *03/30/1979 auto CT CT CT 03/30/2023 03/30/2023 03/30/2023 12:59:23 PM TP -1602.2 12:59:23 PM 12:59:23 PM TP -1607.0 TP -1611.8 COM Switch to needle detection view 18 19 20 syn • If applied to axial thick slice segments: ➔ Scrolling to slice containing the R R detected needle tip. 10 cm MPR F F • If applied to MPR segments: GT-O 1508 Head GTO. Center GT-0 1509 400 Feet ➔ Aligning MPR planes with direction of Intervention 6 HAR SOMATOM X.ceed Intervention 6 AFL SOMATOM X.ceed Intervention 6 SOMATOM X.ceed 12345 syngo CT VB10A 12345 HFS i-Spiral Abdomen D 60 Br40 syngo CT VB10A 12345 detected needle. i-Spiral Abdomen 0.60 Br40 HFS i-Spiral Abdomen 0.60 Br40 syngo CT VB10A HFS *03/30/1979 *03/30/1979 "03/30/1979 CT CT CT 03/30/2023 03/30/2023 03/30/2023 12:59:21 PM 12:59:21 PM 12:59:21 PM • Switching back to the patient-oriented view can be done with the button: Switch LA RF PL N1 35 mm to Ortho view / Patient-oriented view. N MPRs N1 5 cm 5 cm 5 cm auto 19 Effective Date: 16 May 2024 | QR700007713 * Optional feature. Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 myNeedle Detection* (6) – Angle display SIEMENS Healthineers If the auto needle detection mode is enabled, the system compares the planned auto 2 path with the detected needle. It provides a distance and angles in x and z direction. Intervention 6 AFL SOMATOM X.ceed 12345 i-Spiral Abdomen 0 60 Br40 syngo CT VB10A HFS 03/30/1979 Remaining needle path (measured from CT • 03/30/2023 12:59:21 PM detected needle tip to target) N1 35 mm 4X-9 Angular deviation from planned path in 4 2-16ª • x-plane (scan plane) MPR • Angular deviation from planned path in RF z-plane -N1 35 mm 4 X-9 4 2-163 N1 5 cm MPR 20 Effective Date: 16 May 2024 | QR700007713 * Optional feature. Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 myNeedle Detection* (7) – Needle too far in SIEMENS Healthineers If the auto needle detection mode is enabled and the needle was pushed in auto 2 beyond the planned target, the system Test Intervenidon ] SOMATOM X_ceed syngo CT VB TOA indicates this by the following warning: 1-Sequence Abdomen 060 HFS 03/30/2023 • Red label =N3 -10 mm • Negative remaining path length 4 × 65" 4 Z 670 Angles for correction MPR • RF AN3 -10 mm 5 cm F Intervention> 300.7 1129 MPR Thin 36 MPR 21 Effective Date: 16 May 2024 | QR700007713 * Optional feature. Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 myNeedle Detection* (8) – Tablet SIEMENS Healthineers SIEMENS . EO Test Intervention 1 X Healthineers 03/30/1990 You can also switch on the new feature Auto Needle Detect via the tablet. CTDIvol [mGy] SSDE [mGy] DLP [mGy*cm] (32 cm) 3.01 (23 cm) 5.73 57.6 Accum. [mGy] 3.02 @ -1469.0 mm Accum. [mGy*cm] 59.5 i-Spiral Define Path Progress Needle Needle BP N3 O auto > 31.59:55 AM TP BD 3D + VRT 2D + Ref GONATONILos SOMITOM X CARE 1-Spiral Ackcenas 5 08 0142 CT TP 2D + Topo 2D 2D Single + ... F F Head Center Feet Fixil 416 3D Fusion 24 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Miscellaneous – Larger font size SIEMENS Healthineers The text for “Head, Center, and Feet” is displayed in a larger font on the screens. W 1500 1508 Head 400 GT Q Center 480 GT Q Feet 25 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Miscellaneous – Tips & tricks SIEMENS Healthineers Abdomen Interventio ... i'm Abdomen Interventio ... il myNeedle Laser myNeedle Laser In the first step, you must confirm Patient Weight and RTP Patient Weight 200 lbs Topogram Overlay (a). RTP Overlay None Topogram HF supine HF prone HF right HF left The Confirm button on the next step is related to the patient i-Spiral Abdomen Reconstruction position (b). FF supine FF prone FF right FF left Close Length 512 mm CTDIvol SPR (32 cm) 0.02 mGy But you can always go back to confirm the Patient Weight DLP 0.89 mGy*cm MA and RTP Overlay. 55 kv Sn 100 Exposure Time 3.32 s Check metal detection V i-Spiral Abdomen Reconstruction Close Confirm or skip Step Confirm patient position a) a Confirm OK Cancel b) b) Confirm OK Cancel 26 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com 27 Effective Date: 16 May 2024 | QR700007713 Unrestricted I Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024
- ct
- somaris
- 10
- vb10
- myneedle
- needle
- companion
- improve
- enhance
- delta
- somatom
- go
- now
- up
- all
- top
- exceed
- excite
- x.ceed
- x.cite
- naeotom
- neotom
- neatom
- alpha
- intervention