
Symbia Pro.specta VA10 Creating additional recons
Symbia Pro.specta VA10 Creating additional recons Job Aid
Creating Additional Reconstructions Symbia Pro.specta™ All Symbia Pro.specta™ Systems VA10 This job aid is designed to assist the end user in creating additional reconstructions for either SPECT or CT images on the Symbia Pro.specta™ syngo Acquisition Workstation console. Additional reconstructions may be created before or after the acquisition of a Tomo or CT range. Creating additional reconstructions prior to acquisition 1. In the syngo Acquisition Workspace: • Select the protocol and then click GO to confirm • Select the Reconstruction panel GO SPECT-CT [factory] ( ... Fica Patient position HF supine HF prone HF right HF left FF supine FF prone FF right FF left Tomo Topogram .CT-AC Reconstruction Close Reconstruction SIEMENS Healthineers Creating additional Recons 2. In the Recon Ranges section, right-click on an available CT or Tomo reconstruction and select Repeat. Recon Ranges Tomo 2D AC NAC tomo auto f+ auto auto Topogram CT-AC auto Show Parameters Delete Repeat Copy All Recon Parameters Copy Recon Volume Parameters Paste All Recon Parameters Paste Recon Volume Parameters Create Image with Reference Lines Send to CT View&GO Edit Result in CT View&GO 3. A new recon range will be created. Double-click or right-click and select Show Parameters to view or change any reconstruction parameters. T-AC auto auto Show Parameters Delete Repeat Copy All Recon Parameters Copy Recon Volume Parameters Paste All Recon Parameters Paste Recon Volume Parameters Create Image with Reference Lines Send to CT View&GO Edit Result in CT View&GO Recon Favorites General Recon Recon&GO | Image Impression Recon Box Physio Recon Auto Tasking Scan/Recon Slice Thickness Increment No. of [mm] [mm] Images Image Order Comment 1 Comment 2 CT-AC 3.00 Qr40 S3 3.00 3.00 129 Feet to Head SIEMENS Page 2 of 8 Healthineers Creating additional Recons 4. If any value is changed, including adding additional text to the Scan/Recon name, the segment will turn Green, indicating a successful change in value. Recon Favori ... General Recon Recon&GO Image Impression | Recon Box | Physio Recon Auto 1 Scan/Recon Slice Thickness Incremen No. of [mm] [mm] Images Image Order Comment 1 Comment 2 CT-AC 3.00 Or40 S3 3.00 3.00 Feet to Head The new reconstruction will now be available when performing the acquisition. SIEMENS Page 3 of 8 Healthineers Creating additional Recons Creating additional reconstructions after completing acquisitions 1. In the Patient Browser, right-click on the examination, and select Recon. Results (1 results, 5:30:16 PM) Ser Patient Modality Study Date and T .. Study Descript. Exported Study Archived DEMO 02/28/1979, 111111 CT, NM, SR 02/28/2023 5:06:16. SPECT-CT [f .. Tomo Open Ctrl+O @ Open with View as Read-Only with Batch Open Assign Workflow Cancel Workflow Search Patient with DICOM Q/R Add to Demo List Remove from Demo List Set Mark state Set Delete Protection state St Set Archive state Remove Correction state New Examination Resume Examination Correct x Cu Paste Delete Del Manage Raw Data Recon Ctrl+Alt+R 2. The viewer will open to the syngo Acquisition Workspace. Select the Reconstruction panel. SPECT-CT [factory] ( -.. Recon Ranges Patient position Tomo Tomo Topogram CT.AC Topogram Reconstruction Close CT-AC SIEMENS Page 4 of 8 Healthineers Creating additional Recons 3. In the Recon Ranges section, right-click on a completed CT or Tomo reconstruction and select Repeat. Recon Ranges Tomo Topogram CT-AC Show Parameters Delete Repeat Copy All Recon Parameters Copy Recon Volume Parameters Paste All Recon Parameters Paste Recon Volume Parameters Create Image with Reference Lines Send to CT View&GO Edit Result in CT View&GO SIEMENS Page 5 of 8 Healthineers Creating additional Recons 4. Double-click or right-click on the new range and select Show Parameters to view or change any reconstruction names or values. Recon Ranges Tomo Topogram CT-AC Show Parameters Delete Repeat Copy All Recon Parameters Copy Recon Volume Parameters Paste All Recon Parameters Paste Recon Volume Parameters Tools Create Image with Reference Lines Send to CT View&GO Edit Result in CT View&GO 5. If any value is changed, including adding additional text to the Scan/Recon name, the segment will turn Green, indicating a successful change in value. Recon Favori ... General Scan/Recon Slice Thicknes: [mm] CT-AC 3.00 Qr40 S3 NEW RECON 3.00 SIEMENS Page 6 of 8 Healthineers Creating additional Recons 6. Click the Recon button once all parameters are confirmed to create the reconstruction. CT-AC auto Tools Ld MPR MIP Thin Set FoV Set Ref Segment Segment Planning Base Topogram CT-AC RT Recor Cancel 7. Clicking on the Close panel will show progress of all available reconstructions. Any in- progress reconstructions will finish even if the examination is closed. SPECT-CT [factory] ( ... fama) Job Status Patient position Range Name Series Description Requested Procedure Recon Progress Drde Tomo Tomo Tomo Delay Tc-99m Tomo Projections AC Recon Tomo Delay Tc-99m Topogram NoAC Recon Tomo Delay Tc-99m .CT-AC . CT-AC CT-AC 3.00 Qr40 S3 Reconstruction CT-AC 3.00 Qr40 S3 NEW RECON Close Cancel Open Recon Tab SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 30 Mar 2023 | HOOD05162003339395 Page 7 of 8 Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (here- inafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2023 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 8 of 8