Styletting HM Wash Probes on the Dimension® Family of Integrated Chemistry Systems Video

This video demonstrates how to stylette the HM Wash Probes on the Dimension® Family of Integrated Chemistry Systems.

This video applies to the dimension EXL with LM integrated chemistry system, dimension Excel 200 integrated chemistry system, dimension RXL Max integrated chemistry system, and dimension expand and expand plus integrated chemistry systems. With the system in standby, display the HM Pump Prime screen from the operating menu by selecting F4 system RE. Select F7 pump prime. Select F6 HM. Raise the imp lid. Then insert a strong slender tool into the reagent lid latch, press firmly and raise the reagent lid. Locate the wash pro. Disconnect the green aspirate tubing from the wash probe. Using a screwdriver, remove the plastic guard from the wash station by loosening the two screws on the facing side until the guard can slide out from under the screws. Next, dislodge any obstructions or accumulations by passing an IMT stylet completely through the aspirate probe from top to bottom. Be sure to style it the aspirate side of the probe located toward the back of the HM Wash probe. The dispensed probes should not be styled as there is a contamination risk. Dispose of the used iimt stylet into a biohazard waste container. Reconnect the tubing to the probe. Ensure the blue and green labeled tubing is attached to the correct aspirate probes. To reconnect the tubing to the correct aspirate probes, refer to the HM Wash Station illustration located on the back panel of the analyzer adjacent to the Wash station. The HMM wash diagram is also available in the dimension system operators guide. Reinstall the bottom plastic guard onto the wash station. On the HM Pump Prime screen, enter the number 3 in the cycle count field. Then select F1 HMM wash pump to prime the HM Wash pump. Finally, close the instrument lids and perform a system check. Refer to the dimension systems operators guide for this procedure. If documenting using the paper logs from the dimension system operators guide, document the maintenance in the weekly, monthly maintenance log sheet or instrument log sheet. Or, if documenting using the electronic logs in the dimension system software, document the maintenance in the instrument log screen.

001-8 #2 #1 0.0 Styletting HM Wash Probes on the Dimension® Family of Integrated Chemistry Systems Video SIEMENS . Standby Sampler Idle IMT OK 09/14/22 21:23 Dimension Exit labmanager Enter en OPERATING MENU STAT Status PLEASE SELECT AN OPTION USING THE FUNCTION KEYS: Sample Alert Supplies At any time, press HELP to get help, or press EXIT to exit a program. QC Alert Calib Alert To Shut down or Change Operator, press Sign Out or Alt+EXIT. Run Home F1: ENTER DATA F2: SAMPLE STATUS F3: TEST RESULTS F4: SYSTEM CHECK F5: PROCESS CTRL F6: SYSTEM CONFIG F7: DIAGNOSTICS F8: SEGMENT STATUS 01/12/23 07:43 SYSTEM PREPARATION MENU F1: INVENTORY F2: REAGENT PREP F3: IMT F5: TEMP MONITOR F6: SYS COUNTERS F7: PUMP PRIME F8: DAILY MAINT. Diagnostics PUMP PRIME CYCLES: 10 IMT SAMPLER REAGENT 1 REAGENT 2 DIL PUMP REAGENT 3 F1: PRIME WATER F2: SAMPLER F3: REAGENT 1 F4: REAGENT 2 F5: IMT DIL PUMP F6: HM ... F7: REAGENT 3 F8: Dimension EXL 20 Dimensior Dimensi SIEMENS Healthineers Dimension EXL 200 3 4 1 2 COM CLAMP WASH PROB 2 COM WAS PRESSURE WASHPROBE SWITCH HOME SENSOR ASSEMBLY J45D J45B 2 NO WASH ASPIRATE CABLE PROBE J45A MOTOR TO VACUUM WASTE WASH BUFFER #2 CONDUIT J45C 2 COM T 01/12/23 07:58 HM PUMP PRIME CYCLES: HM REAGENT CLEANER F1: HM WASH PUMP F2: REAG CLEANER F3: SAMP CLEANER F4: F5: F6: F7: Priming pumps ... Dimen Dim System Prep 01/12/23 06:06 DAILY MAINTENANCE ROUTINES TEMPERATURE CHECK Cuvette: 37.0 C Reagent: 4.0 C HM: 38.0 C Hydration: 4.0 C Reagent (RMS): PUMP PRIME (10 Cycles) SYSTEM CHECK (Cuvettes: 11808 Failed QC: 0) EMPTY CUVETTE WASTE CHK Lot: Carton Values: POSITION INITIALS SAMPLE ID SAMPLE FLUID AUTO SAMPLER CHECK CHK F1: START F3 F5: OFFBOARD LOTS F6: INSTRUMENT LOG F7: MAINT LOGS F8: AUTO SETUP MAINTENANCE LOGS Year: 20XX Clean R3 Operator Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthcare GmbH 2023 He

  • Dimension
  • dimension
  • wash probes
  • wash probe
  • HM
  • stylette
  • styletting
  • HM wash probe
  • styletting hm wash probe
  • Styletting HM Wash Probes