
SPECTsyngo VA30 New Features
This job aid reviews the new features in SPECTsyngo software version VA30.
SPECTsyngo VA30 New Features Symbia Pro.specta VA30 In this job aid, we will review the new features available in SPECTsyngo VA30. Please note that some of these features are optional. The following features will be discussed: ✓ myExam Satellite Remote Reconstruction ✓ High Speed 0.5s: Faster CT scans with Symbia Pro.specta Q3 and X3 ✓ Cardiac Quantification myExam Satellite Remote Reconstruction Reconstruction of SPECT and CT data is now possible at the myExam satellite workstation which is used in conjunction with a Symbia Pro.specta system. As a refresher, the myExam Satellite is an additional workstation that shares a database with the Symbia Pro.specta system providing real-time access to the data acquired at the system. With the addition of remote reconstruction from the myExam satellite workstation, the reconstructions of both NM and CT raw data can be planned and executed while data acquisition continues at the syngo Acquisition Workplace on the system. SIEMENS ... Healthineers ? * @ Patient Browser Local Data ch by Name, ID, Date, Description and Modality (Ctrl+F) More Filters Open Open with DicoM Serie Correct R Results (149 results, 10:18:23 AM) Series Patient Modality Study Date and Ti ... Study Descripti ... Exported Study Archived Series Number Series Description Modality # Instances in Series Series Archived Exported dynamic 2 Tomo Delay Tc-99m Tomo Projections NM *01/11/2002, Open M RawData NM Ctrl+o 2024.01.11-16:34:22-STD-1.3.12.2.1107.5.99.3 Raw data CT Open with › static test Il pogram 0.70 Tr20 cor CT View as Read-Only with tient Protocol CT *01/11/2004. 2024.01.11-16:19:39-STD-1.3.12.2.1107.5.99.3 Batch Open SR Assign Workflow amination Report SR › autolaunch test -AC 3.00 Qr40 53 CT 129 *01/11/2004, Cancel Workflow -AC 3.00 Qr40 53 CT 129 2024.01.11-15:56:40-STD-1.3.12.2.1107.5.99.3 Search Patient with DICOM Q/R Recon Tomo Delay Tc-99m NM › dynamic test Send to Archive Ctrl+Shift+ Recon Tomo Delay Tc-99m NM *01/11/2002, DAC Recon Tomo Delay Tc-99m NM Add to Demo List 2024.01.11-14:51:41-STD-1.3.12.2.1107.5.99.3 Recon Tomo Delay Tc-99m NM Remove from Demo List -AC 3.00 Qr40 53 CT 129 > CT only bottle Set Mark state Recon Tomo Delay Tc-99m TEST NM *01/11/1954, 2024.01.11-12:01:02-STD-1.3.12.2.1107.5.99.3 Set Delete Protection state Bottle2 Set Archive state *01/11/1944, Remove Correction state 2024.01.11-11:30:26-STD-1.3.12.2.1107.5.99.3 Correct Image Comments Image Type Number of Fra ... Slice Thickness + SPECT-CT [fact .. Cut :06:30 AM NM 01/11/2024 11:30: ... Original, Primary, TOMO, EMISSION 120 Bottle Paste *01/11/1944, Malata 2024.01.11-11:05:19-STD-1.3.12.2.1107.5.99.3 Recon Ctrl+Alt+R CT, NM, SR 01/11/2024 11:05: .... SPECT-CT [fact. › caudal test *01/10/2001, 2024.01.10-16:07:05-STD-1.3.12.2.1107.5.99.3 aaaaaaaaaaa *01/10/2002 Search successfully completed Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 SIEMENS Master Template Effective Date: 2 Jan 2025 | HILS 2224 Job Aid Effective Date: 13 May 2025 | QR7/HILS# Healthineers Job Aid | SPECTsyngo VA30 New Features Effective Date: 13 May 2025 | QR70022369 The system allows the ability to auto-launch a viewing application onto the myExam Satellite workplace. Follow the steps below to configure this within the protocol: 1. Navigate to the Protocol Parameters. 2. Select the Auto Tasking tab, find the Workplace column. 3. Set the parameter to Satellite Console and save the protocol. Scan/Recon Auto Tasking Scan/Recon Auto Recon Recon Ref Body Part Transfer Lines Requested Procedure Examined Workplace Topogram Topogram 0.70 Tr20 cor Auto Spine Acquisition Workplace CT AC CT AC 3.00 Qr40 A3 On Off Spine Acquisition Workplace WB Tomo Tomo Delay Tc-99m Tomo Projections On SPINE Acquisition Workplace AC Recon Tomo Delay Tc-99m On SPINE Acquisition Workplace AC Recon Tomo Delay Tc-99m On SPINE Acquisition Workplace NoAC Recon Tomo Delay Tc-99m On SPINE Acquisition Workplace Satellite Console 1 High Speed 0.5s: Faster CT scans with Symbia Pro.specta Q3 and X3 With VA30, an advanced system architecture enables the ability to perform CT scans with 0.5s ro- tation speed for the Symbia Pro.specta Q3 and X3. With the high speed 0.5s option, the same scan range can be acquired in shorter scan time. Scan/Recon Timing × Scan/Recon Pitch Rot. Exam Time Absolute Start Time [s] [s] Patient Instruction Delay: Actu ... Topogram 5.88 None 2.8 | 3 Topogram 0.70 Tr20 cor CT AC 0.80 0.80 35.39 None 3.0 1 3 CT AC 3.00 Qr40 A3 0.50 WB Tomo 0.80 0.0 | 0 Tomo Delay Tc-99m Tomo Projections 1.00 AC Recon Tomo Delay Tc-99m 1.50 AC Recon Tomo Delay Tc-99m NoAC Recon Tomo Delay Tc-99m SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Master Template Effective Date 2 Jan 2025 | HILS 2224 Healthineers Page 2 of 5 Job Aid | SPECTsyngo VA30 New Features Effective Date: 13 May 2025 | QR70022369 This faster rotation speed is supported for all organ attenuation correction (AC) protocols includ- ing whole-body. The CT with the fast rotation will only need to be linked in the recon to be used for the AC. To do this: 1. Navigate to the Protocol Parameters. 2. From the Recon Favorites tab, ensure the fast rotation CT is selected in the Attenuation Correction column. Wholebody CT-S ...= ) Protocol Selection Protocol Parameters Invalid parameters, saving is not possiblel Wholebody CT-SPECT [cus ... Protocol Description -Indications: -Scan modes: RoutineSpiralAdultAbdomenSn, Wholebody180Tomo Save Save as Scan Favorites General Scan Gantry Settings Dose Timing Config Physio Scan Topogram CT AC Recon Favorites General Recon Recon&GO Image Impression Recon Box Physio Recon Auto Tasking Inlin WB Tomo A Scan/Recon Recon Favorites Reconstruction Scan/Recon Basic Recon Recon Mode Method Attenuation Correction Scatter Intra-Recon Close Correction Motion C ... Topogram Topogram 0.70 Tr20 cor CT AC CT AC 3.00 Qr40 S3 WB Tomo AC Recon Tomo Delay Tc-99m Wholebody Flash 3D- (2-1) CT AC 3.00 Qr40 S3 Off NoAC Recon Tomo Delay Tc-99m Wholebody Flash 3D4 NOTTE on Off Off For CT standalone protocols, this faster speed is supported only supported for the thorax proto- cols where the scan mode is set to one of the following: • RoutineSpiralAdultThorax • RoutineSpiralAdultThoraxSn • RoutineSpiralChildThorax • RoutineSpiralChildThoraxSn Please note: Calcium scoring protocols do not support 0.5s rotation speed. SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Master Template Effective Date 2 Jan 2025 | HILS 2224 Healthineers Page 3 of 5 Job Aid | SPECTsyngo VA30 New Features Effective Date: 13 May 2025 | QR70022369 Cardiac Quantification xSPECT Quant Tc99m and Broad Quantification now offer the ability to create cardiac SPECT gated and non-gated quantitative reconstructions with LEHR or LEUHR collimators with 90 or 180 configurations. Data is saved as PET DICOM output with the option to evaluate Bq/ml or SUV measurements in viewing applications. Cardiac SPECT-CT [factory] Protocol Description -Indications: -Scan modes: Cardiac90Tomo, RoutineSpiralAdultAbdomenSn Instru Scan Favorites General Scan Gantry Settings Dose Timing Config Physio Scan Contrast CH Recon Favori ... General Recon O Recon&GO Image Impre ... / Recon Box Physio Recon Auto Tasking Inline Options Scan/Recon Image Impression Scan/Recon Energy Quant Window Set Roman Recon Mask Recon Paramet ... Filter Photopeak [keV] Image Type Window@120kV Tomo Tomo Stress Tc-99m Tomo Projections Tc99m_Siemens Tomo AC PET Stress Tc-99m MC Tc99m Siemens On Mu Map Standard Gaussian 140.51 PET AC PET Gated Stress Tc-99m MC Tc99m_Siemens On Mu Map Standard Gaussian 140.51 PET Gated NoAC PET Stress Tc-99m MC Tc99m_Siemens On Detector Orbit Standard Gaussian PET NoAC PET Gated Stress Tc-99m MC Tc99m Siemens On Detector Orbit Standard Gaussian PET Gated Topogram Topogram 0.70 Tr20 cor Topogram Body CT-AC CT-AC 3.00 Qr40 A3 Cardio Please note: SMARTzoom collimators are not supported for quantification. SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Master Template Effective Date 2 Jan 2025 | HILS 2224 Healthineers Page 4 of 5 Job Aid | SPECTsyngo VA30 New Features Effective Date: 13 May 2025 | QR70022369 Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or In- structions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Opera- tor Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety infor- mation like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functional- ity”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fic- tional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Master Template Effective Date 2 Jan 2025 | HILS 2224 Healthineers Page 5 of 5
- va30
- spectsyngo
- pro.specta